• Title/Summary/Keyword: m-factor

Search Result 8,697, Processing Time 0.034 seconds

Optimal Inductance of Three-phase High-Power Factor Converter (3상 고역률 AC/DC 컨버터의 부하에 따른 최적 인덕터값)

  • Chun, J.H.;Kim, C.S.;Bark, J.M.;Lee, S.H.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.246-249
    • /
    • 1995
  • This paper proposed a partial resonant swtiching three-phase high power factor converter using a lossless snubber. The proposed converter has a merit of simple controlled circuit because tile input current control discontinuously. And it is improve to input power factor that the snubber capacitor's energy regenerate to the AC source side. This topology is reduced a current/voltage stresses of resonant devices in addition to a partial resonant strategy. The result of simulations with the proposed topology included in this paper.

  • PDF

Evaluation of wind power potential for selecting suitable wind turbine

  • Sukkiramathi, K.;Rajkumar, R.;Seshaiah, C.V.
    • Wind and Structures
    • /
    • v.31 no.4
    • /
    • pp.311-319
    • /
    • 2020
  • India is a developing nation and heavily spends on the development of wind power plants to meet the national energy demand. The objective of this paper is to investigate wind power potential of Ennore site using wind data collected over a period of two years by three parameter Weibull distribution. The Weibull parameters are estimated using maximum likelihood, least square method and moment method and the accuracy is determined using R2 and root mean square error values. The site specific capacity factor is calculated by the mathematical model developed by three parameter Weibull distribution at different hub heights above the ground level. At last, the wind energy economic analysis is carried out using capacity factor at 30 m, 40 m and 50 m height for different wind turbine models. The analysis showed that the site has potential to install utility wind turbines to generate energy at the lowest cost per kilowatt-hour at height of 50 m. This research provides information of wind characteristics of potential sites and helps in selecting suitable wind turbine.

Light Factor Performance of a Room with Light Guide and Blind Systems by Mockup Experiments (혼합형 채광조절장치가 실내공간의 주광조도분포에 미치는 영향에 관한 Mockup 실험평가)

  • Shin, Hwa Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.23-31
    • /
    • 2007
  • This study aims to evaluate the illuminance performance of sloped light guide with automated venetian blind systems. For the purpose, a mock-up model was constructed as a prototype of Korean office building with $12.0m{\times}7.3m{\times}3.7m$ ($w{\times}d{\times}h$) and south facing side-window mounted between the clerestory window($2.0m^2$) and the view window($5.6m^2$). The light guide of 1.28m deepth and $29^{\circ}$ tilted angle, is covered with 0.6mm galvanized steel sheet and 97% reflective film. To protect the room from low solar angle, a blind systems, 0.15m deepth and $30^{\circ}$ automated slat angle was installed. To assess illuminance performance, the totally 37 measuring points for illuminance were monitored. For the detailed analysis, photometric sensors were installed at work-plane (8 points), wall (7 points), ceiling (3points), and exterior horizontal illuminance (1 point) respectively. The performance was measured under clear sky and is monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons of light factor and uniformity are discussed.

Microwave Dielectric Properties of $(Pb_{1-x}Ca_x)ZrO_3$ and $(Pb_{0.63},Ca_{0.37-x}M_x)ZrO_3$ (M = Mg, Sr) Ceramics ($(Pb_{1-x}Ca_x)ZrO_3$$(Pb_{0.63},Ca_{0.37-x}M_x)ZrO_3$ 세라믹스의 고주파 유전 특성)

  • 윤중락;이헌용
    • Electrical & Electronic Materials
    • /
    • v.10 no.6
    • /
    • pp.533-540
    • /
    • 1997
  • The microwave dielectric properties of ((P $b_{1-x}$ C $a_{x}$)Zr $O_3$ and (P $b_{0.63}$,C $a_{0.37-x}$ $M_{x}$)Zr $O_3$(M=Mg,Sr) ceramics were investigated. In (P $b_{1-x}$ C $a_{x}$)Zr $O_3$ (X=0.33~0.40) ceramics, high quality factor and small temperature coefficient of resonant frequency were obtain in (P $b_{0.63}$C $a_{0.37}$)Zr $O_3$with perovskite structure. In the case of (P $b_{0.63}$C $a_{0.37-x}$M $g_{x}$)Zr $O_3$ dielectric constant temperature coefficient of resonant frequency increased and quality factor decreased due to increase of polarization of A-O bonding. When replacing Ca ion with Sr ion with large ion radius, polarization decreased with increased of bonding length and thus dielectric constant and temperature coefficient of resonant frequency decreased.decreased.creased.

  • PDF

Experimental Study on the Relationships between Earthwork Volumes and Soil Conversion Factor with Depth (심도별 토량환산계수와 토공량 변화에 관한 실험적 연구)

  • Gichun Kang;Kyoungchul Shin;Seong-kyu Yun
    • Land and Housing Review
    • /
    • v.14 no.3
    • /
    • pp.137-144
    • /
    • 2023
  • The amount of soil cutting, transported, and filing up the soil in the project area is considered to change the volume depending on the condition of the soil; the volume change rate of the soil is calculated by collecting undisturbed samples below 1 m to 2.0 m above the surface through test pits. In this study, large-scale field tests are carried out. There are areas with an excavation depth of 10m or more, but some errors have occurred in calculating the soil volume by uniformly applying the soil conversion factor for a depth of 1 to 2 m. According to the field tests, the earthwork volumes applied with the soil conversion factor for each depth increase by 3.9 to 9.4% compared to the soil volume applied uniformly with that of 2 m depth.

Application of internet of things for structural assessment of concrete structures: Approach via experimental study

  • D. Jegatheeswaran;P. Ashokkumar
    • Smart Structures and Systems
    • /
    • v.31 no.1
    • /
    • pp.1-11
    • /
    • 2023
  • Assessment of the compressive strength of concrete plays a major role during formwork removal and in the prestressing process. In concrete, temperature changes occur due to hydration which is an influencing factor that decides the compressive strength of concrete. Many methods are available to find the compressive strength of concrete, but the maturity method has the advantage of prognosticating strength without destruction. The temperature-time factor is found using a LM35 temperature sensor through the IoT technique. An experimental investigation was carried out with 56 concrete cubes, where 35 cubes were for obtaining the compressive strength of concrete using a universal testing machine while 21 concrete cubes monitored concrete's temperature by embedding a temperature sensor in each grade of M25, M30, M35, and M40 concrete. The mathematical prediction model equation was developed based on the temperature-time factor during the early age compressive strength on the 1st, 2nd, 3rd and 7th days in the M25, M30, M35, and M40 grades of concrete with their temperature. The 14th, 21st and 28th day's compressive strength was predicted with the mathematical predicted equation and compared with conventional results which fall within a 2% difference. The compressive strength of concrete at any desired age (day) before reaching 28 days results in the discovery of the prediction coefficient. Comparative analysis of the results found by the predicted mathematical model show that, it was very close to the results of the conventional method.

An Experimental Study on Droplet Size according to Discharge Coefficient of Sprinkler Head (스프링클러 헤드의 방수상수에 따른 물방울 크기에 관한 실험적 연구)

  • Hur, Min Noung;Shin, Changsub
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.4
    • /
    • pp.16-21
    • /
    • 2017
  • The sprinkler system is a basic fire extinguishing system that uses water as an extinguishing agent. In order to evaluate the fire extinguishing performance of the sprinkler system, information such as the discharge angle, discharge speed, discharge pressure, flow rate, and water droplet size of the installed head are required. However, there is a lack of research on droplets size compared to other requirements. In this study, to evaluate the extinguishing characteristics of sprinkler system, the droplet size distribution was measured for various types of sprinkler heads actually used. The size of the droplet was measured using laser diffraction method. The 50% cumulative volume distribution ($D_{v50}$) according to discharge coefficient(K factor) was $540{\mu}m{\sim}695{\mu}m$ for K50, $542{\mu}m{\sim}1,192{\mu}m$ for K80, $980{\mu}m{\sim}1,223{\mu}m$ for K115 and $1,188{\mu}m{\sim}1,234{\mu}m$ for K202. Based on the measured results, the vaeiance of the droplet particle distribution and the distribution ($D_{v50}$) according to discharge coefficient(K factor) was $540{\mu}m{\sim}695{\mu}m$ for K50, $542{\mu}m{\sim}1,192{\mu}m$ for K80, $980{\mu}m{\sim}1,223{\mu}m$ for K115 and $1,188{\mu}m{\sim}1,234{\mu}m$ for K202. Based on the measured results, the vaeiance of the droplet particle distribution and the Rosin-Rammler index value are presented. As a result of the fire simulation with FDS, it was confirmed that the performance difference occurs according to the water droplet size distribution even when the same amount of water is used. Therefore, the extinguishing performance of the sprinkler system should be evaluated considering the droplet size distribution according to the sprinkler head type.

A Study on the Road Traffic Noise Restriction Factors that Affect the Price of Apartment Complexes (아파트 가격에 영향을 미치는 도로교통소음 제한인자에 관한 연구)

  • Park, Sang-Ill;Choi, Hyung-Il;Cheong, Kyung-Hoon;Jung, Sang-Chul
    • Journal of Environmental Science International
    • /
    • v.18 no.4
    • /
    • pp.389-400
    • /
    • 2009
  • In this research, we measured the number of lanes, distance, disposition of apartment that are affecting the road traffic noise to evaluate the current condition of G city's road traffic noise. We decide on a basis regarding an apartment price formation factor, and the apartment current price and the results that compared. To have a point scale, we set the maximum road traffic noise at a 8 lane road for 5 points, give 4 points for a 6 lane road, which has a $2.1{\sim}2.5\;dB(A)$ difference compared to a 8 lane road, give 3 points for a 4 lane road, which has a $5.2{\sim}5.5\;dB(A)$ difference compared to a 8 lane road, and set 2 points for a 2 lane road and lower. If we set the standard floor plan as horizontal and a living room facing the roadside, the horizontal and living room facing the opposite side of the road is 1 point because it differs by 14.1 dB(A), and the vertical is 3 points since the difference is 5.3 dB(A). If we make grades by the distance, making standard the fifth floor with little soundproof effect from apartment to road, we observe a measurement below 2.9 dB(A) at a distance of less than 10 m and 5 dB(A), decreased at a distance of 20 m. Therefore, 4 points were given for less than 10m, 3 points for $10{\sim}20\;m$, 2 points for more than 20 m as we can apply the effect of a decay distance of line sound source and the decrease in noise effects of more than 6 dB(A), 1 point for more than 40m, and 0 points for more that 80 m since it is negligible. 28 apartments got 0 points because there is no effect of road traffic noise from other apartments, and 50 apartments where only the road at one side effect them got $5{\sim}10$ points. 4 apartments (17-2, 6-3, 10-4, 3-3) received over 20 points. 15 cases showed a difference between developer price and resale price, and 11 cases (73%) among them showed the same trend (price increases with a low road traffic noise restriction factor point) with the point of road traffic noise restriction factor. 4 cases demonstrated the opposite trend, showing price increases with a high restriction factor point. Among the 4 cases, case numbers 2,6 and 9 appear to be more affected by the location factor (business district) than the road traffic noise restriction factor, and case number 1 appears to be affected by the building factor (openness and direction).

Effect of Germinated Brown Rice on LPS-Induced Inflammation in Adipocytes (발아현미가 LPS로 유도된 지방세포의 염증반응에 미치는 영향)

  • Park, Mi-Young
    • Journal of the Korean Society of Food Culture
    • /
    • v.33 no.4
    • /
    • pp.337-344
    • /
    • 2018
  • Germinated brown rice (GBR, Orysa sartiva L.) has been reported to have anti-obesity and anti-inflammatory effects. However, the mechanisms underlying these effects in adipocytes are not fully understood. Therefore, this study was conducted to explore the anti-inflammatory mechanisms of GBR on lipopolysaccharide (LPS)-stimulated 3T3-L1 adipocytes. 3T3-L1 adipocytes were pretreated with GBR extracts (0-20 mg/mL) 1 h before LPS stimulation. The mRNA expression of adipokines and Toll-like receptor 4 (TLR4) were measured by RT-PCR. The protein expressions of TLR4-related molecules were detected by western blotting and nuclear factor-${\kappa}B$ ($NF-{\kappa}B$) activation was measured. Our results showed that GBR extract dose-dependently inhibited mRNA expression of LPS-induced tumor necrosis factor-${\alpha}$ ($TNF-{\alpha}$), interleukin-6 (IL-6), and monocyte chemoattractant protein-1 (MCP-1). GBR extract was found to inhibit LPS-induced mRNA expression of TLR4 and protein expression of both myeloid differentiation factor 88 (MyD88) and TNF receptor-associated factor 6 (TRAF6). Furthermore, GBR extract significantly inhibited extracellular receptor-activated kinase (ERK) phosphorylation and $NF-{\kappa}B$ activation. These results suggest that GBR extract has the anti-inflammatory effects on LPS-induced inflammation via inhibition of TLR4 signaling, includingthe ERK and $NF-{\kappa}B$ signaling pathways, in adipocytes.

Dielectric and Piezoelectric Properties of Low Temperature Sintering PSN-PZT Ceramics with CeO2 Addition (CeO2첨가에 따른 저온소결 PSN-PZT세라믹스의 유전 및 압전 특성)

  • 류주현;정광현;정영호
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.5
    • /
    • pp.481-485
    • /
    • 2004
  • 0.91 (PSN-PZT) -0.05BF -0.04PNW+0.3wt%MnO$_2$+0.6wt%CuO+xwt%CeO$_2$ ceramics were fabricated with the variations of CeO$_2$addition at the sintering temperature of 95$0^{\circ}C$ and their microstructure, dielectric and piezoelectric characteristics were investigated. As the amount of CeO$_2$ addition increased, the grain size, density and electromechanical coupling factor(k$_{p}$) were increased and the mechanical quality factor(Q$_{m}$ ) was decreased. At the 0.3 wt% CeO$_2$, the density, grain size, electromechanical coupling factor(k$_{p}$), and pizoelectric constants(d$_{33}$, g$_{33}$) showed the maximum value of 7.87 g/㎤, 3.22 $\mu\textrm{m}$, 0.5, 289 pC/N, and 22.2 ㎷ㆍm/N, respectively. However, mechanical quality factor(Q$_{m}$ ) showed the minimum value of 807 at the 0.5 wt% CeO$_2$.$.EX>.EX>.