• 제목/요약/키워드: lysis

검색결과 457건 처리시간 0.02초

Development of a Simple Cell Lysis Method for Recombinant DNA Using Bacteriophage Lambda Lysis Genes

  • Jang, Bo-Yun;Jung, Yun-A;Lim, Dong-Bin
    • Journal of Microbiology
    • /
    • 제45권6호
    • /
    • pp.593-596
    • /
    • 2007
  • In this study, we describe the development of a simple and efficient method for cell lysis via the insertion of a bacteriophage lambda lysis gene cluster into the pET22b expression vector in the following order; the T7 promoter, a gene for a target protein intended for production, Sam7 and R. This insertion of R and Sam7 into pET22b exerted no detrimental effects on cellular growth or the production of a target protein. The induction of the T7 promoter did not in itself result in the autolysis of cells in culture but the harvested cells were readily broken by freezing and thawing. We compared the efficiency of the cell lysis technique by freezing and thawing to that observed with sonication, and determined that both methods completely disintegrated the cells and released proteins into the solution. With our modification of pET22b, the lysis of cells became quite simple, efficient, and reliable. This strategy may prove useful for a broad variety of applications, particularly in experiments requiring extensive cell breakage, including library screening and culture condition exploration, in addition to protein purification.

Statistical Optimization of the Lysis Agents for Gram-negative Bacterial Cells in a Microfluidic Device

  • Kim, Young-Bum;Park, Ji-Ho;Chang, Woo-Jin;Koo, Yoon-Mo;Kim, Eun-Ki;Kim, Jin-Hwan
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제11권4호
    • /
    • pp.288-292
    • /
    • 2006
  • Through statistically designed experiments, lysis agents were optimized to effectively disrupt bacterial cells in a microfluidic device. Most surfactants caused the efficient lysis of Gram-positive microbes, but not of Gram-negative bacteria. A Plackett-Burman design was used to select the components that increase the efficiency of the lysis of the Gram-negative bacteria Escherichia coli. Using this experimental design, both lysozyme and benzalkonium chloride were shown to significantly increase the cell lysis efficiency, and ATP was extracted in proportion to the lysis efficiency. Benzalkonium chloride affected the cell membrane physically, while lysozyme destroyed the cell wall, and the amount of ATP extracted increased through the synergistic interaction of these two components. The two-factor response-surface design method was used to determine the optimum concentrations of lysozyme and benzalkonium chloride, which were found to be 202 and 99 ppm, respectively. The lysis effect was further verified by microscopic observations in the microchannels. These results indicate that Gram-negative cells can be lysed efficiently in a microfluidic device, thereby allowing the rapid detection of bacterial cells using a bioluminescence-based assay of the released ATP.

한 쌍의 전극으로 전기 삼투 유동과 세포 분쇄 기능을 동시에 구현한 연속적인 세포 분쇄기 (A Continuous Electrical Cell Lysis Chip using a DC Bias Voltage for Cell Disruption and Electroosmotic Flow)

  • 이동우;조영호
    • 대한기계학회논문집A
    • /
    • 제32권10호
    • /
    • pp.831-835
    • /
    • 2008
  • We present a continuous electrical cell lysis chip, using a DC bias voltage to generate the focused high electric field for cell lysis as well as the electroosmotic flow for cell transport. The previous cell lysis chips apply an AC voltage between micro-gap electrodes for cell lysis and use pumps or valves for cell transport. The present DC chip generates high electrical field by reducing the width of the channel between a DC electrode pair, while the previous AC chips reducing the gap between an AC electrode pair. The present chip performs continuous cell pumping without using additional flow source, while the previous chips need additional pumps or valves for the discontinuous cell loading and unloading in the lysis chambers. The experimental study features an orifice whose width and length is 20 times narrower and 175 times shorter than the width and length of a microchannel. With an operational voltage of 50 V, the present chip generates high electric field strength of 1.2 kV/cm at the orifice to disrupt cells with 100% lysis rate of Red Blood Cells and low electric field strength of 60 V/cm at the microchannel to generate an electroosmotic flow of $30{\mu}m/s{\pm}9{\mu}m/s$. In conclusion, the present chip is capable of continuous self-pumping cell lysis at a low voltage; thus, it is suitable for a sample pretreatment component of a micro total analysis system or lab-on-a-chip.

Comparison of Cell Lysis Techniques via Q-TOF LC/MS

  • Kaplan, Ozan;Oncul, Selin;Ercan, Ayse;Celebier, Mustafa
    • Mass Spectrometry Letters
    • /
    • 제11권2호
    • /
    • pp.36-40
    • /
    • 2020
  • Untargeted metabolomics is a useful tool for drug development focusing on novel chemotherapeutic and chemopreventative agents against cancer cells. In recent years, quadrupole time of flight liquid chromatography-mass spectrometry (Q-TOF LC/MS)-based untargeted metabolomic approaches have gained importance to evaluate the effect of these agents at the molecular level. The researchers working on cell culture studies still do not apply standardized methodologies on sample preparation for untargeted metabolomics approaches. In this study, the rough and wet lysis techniques performed on MCF-7 breast cancer cells were compared with each other via the Q-TOF LC/MS-based metabolomic approach. The C18 and hydrophilic interaction liquid chromatography (HILIC) columns were used for the separation of the metabolites in MCF-7 cell lysates. 505 peaks were detected through the HILIC column and 551 peaks were found through the C18 column for the wet lysis technique. This situation supported by the base peak chromatograms showed that the wet lysis technique allowed us to extract higher number of non-polar metabolites. Almost equal number of metabolites was found for the C18 and HILIC columns (697 peaks for the HILIC column and 695 peaks for the C18 column) when the rough lysis technique was used. However, the intensities of polar metabolites were higher for the rough lysis technique on base peak chromatograms for both the HILIC and C18 columns. Although cell lysis technique, which is the first step in the sample preparation for cell culture studies, does not cause dramatic differences in the number of the detected metabolite peaks, it affects the polar and non-polar metabolite ratio significantly. Therefore, it must be considered carefully especially for in vitro drug development studies.

용액 전도도 및 삼투압 조절된 PBS에서의 위암 세포 전기 분해 (Stomach Cancer Cell Lysis in PBS with Conductivity and Osmotic-Pressure Control)

  • 김민수;이국녕;조수형;김병기;김용권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.2137-2139
    • /
    • 2004
  • Cancer cell lysis at pulsed DC is realized using micromachined electrodes. In this research, quantitative analyses are performed on cell lysis results. The cell volume increasing at the pulses applied are analyzed in different medium conditions on osmotic pressure and conductivity, and the cell lysis procedures are studied in detail experimentally. Phosphate buffered saline (PBS) is used as the medium. To change the conductivity of PBS, NaCl concentration of PBS is adjusted, and inositol is used with PBS to control the effects of the osmotic pressure to cell lysis performance.

  • PDF

Spontaneous Tumor Lysis Syndrome Presenting Acute Kidney Injury with Extreme Hyperuricemia and Urinary Stone: A Rare Case of Spontaneous Tumor Lysis Syndrome

  • Kim, Seong Heon;Yang, Eu Jeen;Lim, Young Tak;Kim, Su Young
    • Childhood Kidney Diseases
    • /
    • 제21권1호
    • /
    • pp.31-34
    • /
    • 2017
  • Tumor lysis syndrome is a serious complication of malignancy, resulting from the massive and rapid release of cellular components into the blood. Generally, it occurs after initiation of chemotherapy. The onset of spontaneous tumor lysis syndrome (STLS) before anti-cancer treatment is rare and occurs mostly in Burkitt lymphoma and non-Hodgkin's lymphoma. There are only a few case reports in children. Here, we report a case of STLS secondary to T-cell acute lymphoblastic leukemia (ALL), which presented with urinary stone and subsequent acute kidney injury with severe hyperuricemia. Occult malignancy should be considered in case of unexplained acute kidney injury with extreme hyperuricemia.

Liposome의 광산화반응에 미치는 인삼추출물의 영향 제2보 유동성 및 Lysis에 미치는 영향 (The Effect of Ginseng Extracts on the Photooxidation of Liposome II. The effecton the changes of fluidity and lysis)

  • 백태홍;이준홍
    • Journal of Ginseng Research
    • /
    • 제14권3호
    • /
    • pp.385-390
    • /
    • 1990
  • To investigate the effect of ginseng extracts on the changes of flllidity and lysis of liposome reverse phase evaporation vesicle (REV) was employed as model membrane and methylene blue was used as photosensitizer. Fluoresence polarization (P vaule) that represented fluidity of liposome was increased by photooxidation. All of the ginseng saponin inhibited the increasing rate of P value; the order of effect was ginseng water extract>biol saponin>triol saponin>crude saponin. In trapped G-6-P% measurement for lysis of liposome, ginseng water extract and crude saponin promoted the lysis of liposome. Therefore, we thought that ginseng extracts acted as both antioxidant and detergent.

  • PDF

상피세포 시료 전처리용 마이크로바이오칩에 관한 연구 (Study on Microbiochip for Buccal Cell Lysis and DNA Purification)

  • 하승모;조웅;안유민;황승용
    • 대한기계학회논문집A
    • /
    • 제34권12호
    • /
    • pp.1785-1791
    • /
    • 2010
  • 중합효소 연쇄반응(PCR)을 수행하려면 세포 용해(cell lysis)와 DNA추출(DNA purification)과정이 포함된 시료 전처리 과정을 거쳐야 한다. 종래의 시료 전처리 과정은 계면활성제와 같은 세포용해 버퍼를 이용하거나 열 또는 전기적 방법으로 세포막 파열을 유도하여 세포벽을 깬 후에 잔여물 처리과정을 거쳐 DNA를 추출하게 된다. 본 연구에서는 마이크로 비드와 PDMS 기둥을 이용한 필터가 있는 시료 전처리용 바이오칩을 설계 및 제작하였다. 또한 제작된 바이오칩을 사용하여 $80^{\circ}C$에서 2분간 세포용해를 수행하고 DNA를 추출하였다. 칩에서 전처리과정을 거친 시료내의 DNA농도와 순도를 측정하고 DNA PCR과 겔 전기영동을 통해 시료 전처리용 바이오칩의 성능을 평가하였다.

Photosensitized Lysis of Egg Lecithin Liposomes by L-Tryptophan and N-Acetylphenylalanyl-L-Tryptophan

  • Cho, Dae-Won;Yoon, Min-Joong
    • Bulletin of the Korean Chemical Society
    • /
    • 제7권1호
    • /
    • pp.78-81
    • /
    • 1986
  • The photosensitized lysis of egg lecithin lipid membranes (liposomes) have been performed to UV-B light (270-320 nm) by L-tryptophan(L-Trp) and its peptide such as N-acetylphenylalanyl-L-tryptophan(NAPT) incorporated in the liposomes(ca. 0.1% by weight) or in the external buffer (0.1-0.3 mM). Requirement of oxygenation suggests that the lysis of liposomes is caused by the photosensitized oxidation of lipids. There was significant protection against lysis photosensitized by Trp in the external buffer by low concentration of ferricyanide (0.8 mM), but there was no effect on the lytic efficiency by $N_3^-$ which is singlet oxygen($^1O_2$) quencher, indicative of an electron transfer mechanism involved in the photosensitization. The small change of the lytic efficiency with increasing pH from 4 to 9 was interpreted by large target theory and subsequently indicates that superoxide($O_2^-$) may be an active intermediate for the oxidation. The efficiency of photosensitization of Trp was higher than that of NAPT under the same experimental condition. The weak lytic efficiency of liposomes photosensitized by NAPT was enhanced by incorporating NAPT in liposomes, but it was again quenched by ${\beta}$-carotene incorporated in the bilayer of liposomes. These results indicate that a portion of liposome lysis may be due to $^1O_2$ formation from the excited NAPT.

Bacillus subtilis var. niger에 대한 Lauric Acid의 용균작용 (Lysis Action of Lauric Acid on Bacillus subtilis var. niger)

  • 조석금;조효현
    • 한국식품영양학회지
    • /
    • 제3권1호
    • /
    • pp.23-28
    • /
    • 1990
  • Effect of lauric acid and whir derivatives on the growth of Bacillus subtilis var niger was studied. Lauric acid showed the strongest inhibition among the fatty acids tested, Lysis rate of lauric acid proved to be greatly sensitibility against logarithmic phase cells but was not so influenced by cell concentration. On the other hand, lauric acid was inhibited lysis activity when the pH shift from 7.0 to 5.5

  • PDF