• Title/Summary/Keyword: luting

Search Result 135, Processing Time 0.025 seconds

CURING REACTION OF THE LIGHT CURED FLOWABLE COMPOSITE RESINS THROUGH THE ENDODONTIC TRANSLUCENT FIBER POST (투명 fiber 포스트를 통한 광중합형 접착레진의 중합 반응)

  • Ahn Seok;Park Sang-Won;Yang Hong-So;Vang Mong-Sook;Park Ha-Ok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.1-9
    • /
    • 2006
  • Purpose: The purpose of this study was to evaluate the efficacy and substitute possibility of a newly developed flowable composite resins as a luting cement for translucent fiber post. Material & Method: Two kinds of 12 mm translucent fiber Post (D.T. Light-Post (Bisco, USA) and FRC Postec (Ivoclar vivadent, Liechtenstein) was inserted into the teflon mold (7 mm diameter, 9 mm long) and Filtek-Flow (3M ESPE. USA), a light activated flowable composite resin, was polymerized for 60 seconds through the post. Also, the post was cut from the tip to 9 mm, 6 mm, 3 mm, and Filtek-Flow was light cured according to each length. For comparison, 60 seconds light-cured and 24 hours self-cured two dual cured resin cement (Duo-cement (Bisco, USA) and 2 Panavia-F (Kuraray, Japan)) samples were prepared as control group. Also cavities (1 mm in width, 1 mm in depth and 12 mm in length) were prepared using acrylic plate and aluminum bar, and flowable composite resin was flied and light cured by the diffused light from the fiber post's side wall. The degree of polymerization was measured according to the distance from curing light using Vickers' hardness test. Result: Within the limitation of this study, the following conclusions were drawn: 1. Vickers' hardness of light cured dual cured resin cement and flowable composite resin decreased from Panavia-F, Filtek-Flow and Duo-cement accordingly (p<0.05). In the dual curing resin cement, light curing performed group showed higher surface hardness value than self cured only group (p<0.05). 2. Surface hardness ratio (light cured through fiber post /directly light cured) of D.T. Light-Post using Filtek-Flow showed about 70% in the 6 mm deep and about 50% in the 12 mm deep FRC Postec showed only 40% of surface hardness ratio. 3. Surface hardness ratio by diffused light from the post's side wall showed about 50% at 6 mm and 9 mm deep, and about 40% at 12 mm deep in D.T. Light-Post. However, FRC Postec showed about 40% at 6 mm deep, and almost no polymerization in 9 mm and 12 mm deep.

Influences of luting cement shade on the color of various translucent monolithic zirconia and lithium disilicate ceramics for veneer restorations

  • Ghada Alrabeah;Nawaf Alamro;Atif Alghamdi;Ahmed Almslam;Meshari Azaaqi
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.5
    • /
    • pp.238-247
    • /
    • 2023
  • PURPOSE. The purpose of this study was to assess the effect of resin cement shade on the color of different novel ultratranslucent monolithic zirconia and lithium disilicate veneer materials. MATERIALS AND METHODS. For a total of 40 specimens, flat cylindrical discs with a 9-mm diameter and 0.5-mm thickness were created using CAD/CAM technology. The specimens were divided into five groups according to their material (n = 8) (e.max, Prettau, Aidite, Shofu and Dima) using A1 shade. Resin discs with the same diameter and shade as the specimens served as tooth-colored substructures. Three shades (neutral, light and warm) of resin cement try-in pastes (Variolink Esthetic LC) were used as the luting cement material. The color of each material group was measured before and after cementation using the three cement shades, and the CIE L*a*b* coordinates were obtained with a spectrophotometer. Values for the translucency parameter (TP) and color change delta E (E) before (baseline) and after cementation of each specimen were determined. To compare differences among the material groups within each shade of cement and among various shades of cement within each material, the data were analyzed using one-way ANOVA and post hoc testing. RESULTS. Color coordinates L*, a* and b* significantly changed after the application of try-in pastes relative to baseline values, with a noticeable decrease in lightness (L*) (P < .05). A significant color change (ΔE) was observed in all tested materials after cementation, with ΔE values exceeding 3.3 (P < .05). Although TP changed after cementation for most materials tested, these changes were not statistically significant (P > .05). Shofu and Dima ceramics showed the lowest TP values, while Aidite and Prettau showed the highest TP values. For e.max, translucency decreased after cementation with neutral and warm shades, and it significantly increased after cementation with a light shade. CONCLUSION. The shade of cement significantly altered the final color of the ceramic veneer material to a level above the threshold at which the clinical perception of color change occurred (> 3.3). The TP was not influenced by the cement shade. The translucency levels of the novel ultratranslucent multilayer monolithic zirconia ceramics Aidite and Prettau were higher than that of the lithium disilicate e.max material.

Kidney Transplantation in End-Stage of Renal Failure with Secondary Hyperparathyroidism (속발성 부갑상선 기능항진증을 동반한 말기 신부전의 치료를 위한 신장이식)

  • Kwak, Ho-Hyun;Nam, Hyun-Suk;Kim, Yun-Tai;Park, In-Chul;Han, Jeong-Hee;Woo, Heung-Myong
    • Journal of Veterinary Clinics
    • /
    • v.24 no.4
    • /
    • pp.522-528
    • /
    • 2007
  • A 3-year-old male Maltese dog(weighing 2.5 kg) was referred with an excessive movement of mandible and depression. Comprehensive diagnostic investigation revealed an end-stage of renal disease with secondary hyperparathyroidism. The renal allograft was performed after the condition of dog was stabilized by hemodialysis and medical treatment. After transplantation, the renal function of this dog was returned to normal. thereafter, the dog died suddenly without apparent clinical signs. The subsequent pathological studies revealed the actual etiology of death was not clearly identified However acute pancreatitis caused by abrupt introduction of food after prolonged luting might be involved in the etiology. This case study showed the necessity of pancreatic function test in postoperative management after renal transplantation.

RADIOPACITY OF DENTAL RESTORATIVE MATERIALS AND CEMENTS (수종의 치과용 수복재료 및 시멘트의 radiopacity)

  • Yang Hong-So;Chung Hyun-Ju;Kang Byung-Cheol;Oh Won-Mann
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.1
    • /
    • pp.59-66
    • /
    • 1994
  • The radiopacity of six composite resins, three resin luting cements and ten filling materials were studied. The purpose was to obtain an indication of radiopacity value of different brands within each of these groups of materials and to show differences in radiopacities of filling materials and natural tooth structures. On radiographs, the optimal densities of standardized samples were determined by computer imaging system and radiopacity values of the materials were expressed in millimeter equivalent aluminum. Within the groups of materials studied, there was considerable variation in radiopacity. The composite resins of P-50, Z100 and Prisma AP.H displayed much higher radiopacities than aluminum. Panavia resin cement was shown to be similarly radiopaque to aluminum. Generally, the radiopacity of base and filling materials appeared to be higher than that of the enamel and dentin. If materials with substantial difference in radiopacity are used in combined applications for restorative treatment of teeth, lower radiopacity can interfere with the diagnosis and detection of gaps near the restoration.

  • PDF

THE EFFECT OF VARIOUS DESENSITIZING AGENTS ON RETENTION AND FITNESS OF CEMENTED CROWNS WITH ZINC PHOSPHATE CEMENT (수 종의 지각 과민 완화제가 인산 아연 시멘트 사용시 주조관의 유지력 및 적합도에 미치는 영향)

  • Oh Se-Wook;Lee Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.2
    • /
    • pp.181-194
    • /
    • 1994
  • The purpose of this study was to compare the retention and fitness of crown treated with various desensitizing agents on natural teeth. Varnish, dentin primer, bonding agent and potassium oxalate treated groups and control group with no treatment were used. The retention test was executed with the Instron test machine(Instron Co.,U.S.A.) on 24 hours after cementation with zinc phosphate cement. After retention test, the teeth and crowns were washed and recemented. The cemented crowns were embedded in clear resin and sectioned with a diamond saw. The occlusal and marginal fitnesses, were measured indirectly with a stereomicroscopic photographs. The result of this study were obtained as follows : 1. The retention of control group was higher than any other desensitizing agent treated group. 2. The differences of retention among varnish, dentin primer, bonding agent and potassium oxalate treated groups were not statistically significant. 3. There were no statistically significant difference in fitness at occlusal surface and margin among control, varnish, dentin primer, bonding agent and potassium oxalate treated groups. According to these results, desensitizing agents used to protect the pulp from irritation of luting agents may adversely affect the retention of castings. Therefore, desensitizing agents should be used in limited areas carefully.

  • PDF

Stress distribution of oval and circular fiber posts in amandibular premolar: a three-dimensional finite element analysis

  • Er, Ozgur;Kilic, Kerem;Esim, Emir;Aslan, Tugrul;Kilinc, Halil Ibrahim;Yildirim, Sahin
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.434-439
    • /
    • 2013
  • PURPOSE. The aim of the present study was to evaluate the effects of posts with different morphologies on stress distribution in an endodontically treated mandibular premolar by using finite element models (FEMs). MATERIALS AND METHODS. A mandibular premolar was modeled using the ANSYS software program. Two models were created to represent circular and oval fiber posts in this tooth model. An oblique force of 300 N was applied at an angle of $45^{\circ}$ to the occlusal plane and oriented toward the buccal side. von Mises stress was measured in three regions each for oval and circular fiber posts. RESULTS. FEM analysis showed that the von Mises stress of the circular fiber post (426.81 MPa) was greater than that of the oval fiber post (346.34 MPa). The maximum distribution of von Mises stress was in the luting agent in both groups. Additionally, von Mises stresses accumulated in the coronal third of root dentin, close to the post space in both groups. CONCLUSION. Oval fiber posts are preferable to circular fiber posts in oval-shaped canals given the stress distribution at the postdentin interface.

A STUDY ON THE TENSILE BOND STRENGTH OF ETCHED-METAL RESIN-BONDED RETAINERS (식각된 비귀금속합금과 법랑질을 복합레진계 시멘트로 접착시킨 경우의 접착인장강도에 관한 연구)

  • Park, Heon-Seok;Lee, Sun-Hyung;Yang, Jae-Ho;Chang, Wan-Shik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.24 no.1
    • /
    • pp.85-90
    • /
    • 1986
  • The purpose of this study was to compare the tensile bond strength of Comspan and Panavia as a luting materials between electrochemically etched Ni-Cr-Be alloy castings and acid etchea human tooth enamel. Tensile bond strength was evaluated using an Instron testing machine at a crosshead speed of 2mm/min. The following conclusions can be drawn frfm this study ; 1. The tensile bond strength of etched-metal resin-bonded specimen was $179.0{\pm}42.5kg/cm^2$ in case of Comspan and $169.6{\pm}41.4kg/cm^2$ in case of Panavia. 2. The tensile bond strength was not significantly different between Comspan, using with bonding agent, and Panavia, using without bonding agent.

  • PDF

Prevalence and Associated Factors of Falls in the Elderly Community (지역사회 재가 노인의 낙상에 영향을 미치는 요인)

  • Paek, Kyung-Won;Song, Hyun-Jong;Jung, Yoon-Seok;Moon, Hae-Won;Cho, Joon-Pil
    • Journal of Preventive Medicine and Public Health
    • /
    • v.34 no.1
    • /
    • pp.47-54
    • /
    • 2001
  • Objectives : To analyze factors associated with elderly falls in a community dwelling, a comparatively important, but somewhat neglected, health mailer. Methods : Data came from personal interview surveys using a questionnaire of 552 people aged 65 or older living in a community. Socioeconomic, and health related characteristics were investigated as independent variables and experiences of falling in the previous year as the dependent variable. Results : 118(21.4%) of the elderly subjects experienced a fall in the previous year. 24 subjects experienced more than two falls, accounting for 20.3% of the elderly fall victims studied. Factors affecting the falls were families living together, level of daily activity, heart disease, and aconuresis;, therefore an elderly person who lives alone, lives independently, has heart disease, or suffers urinary incontinence had a demonstrated increased chance of failing. Conclusion : Groups at risk for luting included elderly persons living alone, living independently, suffering heart disease, or experiencing urinary incontinence. When an elderly fall prevention program is developed and implemented, these results should be considered.

  • PDF

THE FILM THICKNESS AND RETENTION OF CAST CROWN USING ADHESIVE RESIN CEMENTS (접착성 레진 시멘트를 이용한 주조관의 피막후경과 유지력에 관한 연구)

  • Jung Young-Wan;Cho Hye-Won;Jin Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.3
    • /
    • pp.437-443
    • /
    • 1992
  • This study was performed to investigate the availability of adhesive resin cement for luting agent of cast crown. The resin cements used in this study were Panavia-Ex(Kuraray Co., Japan) and C & B-Metabond (Parkell Bio-Materials U.S.A.). Zinc phosphate cement was Flecks zinc cement(Mizzy Inc., U.S.A.) The film thickness of cast crown at gingival margin, lateral wall and occlusal surface was observed with measuring microscope(Modek MXT 70 Matsuzawa Seiki Co., Japan) and the retention of cast crown was measured with Instron Universal Test Machine (Instron Engineering Co., U.S.A.) The results were as follows : 1. The value of retention of cast crown was the highest in the use of Panavia-EX, followed by C & B-Metabond and 2inc phosphate cement, respectively. 2. There was no difference in film thickness among the three cements, but the film thickness in all cements was highest at occlusal surface.

  • PDF

Interface Phenomena between Prosthodontic Crown and Abutment Sprayed with Die Spacer (Die Spacer가 도포된 보철용 크라운과 어버트먼트의 계면현상)

  • Park, K.H.;Choe, H.C.
    • Journal of the Korean institute of surface engineering
    • /
    • v.40 no.4
    • /
    • pp.197-202
    • /
    • 2007
  • Fit of the restoration and its cementation procedure is crucial to both its short and long term prognosis. Marginal fit is affected by many variables during the fabrication process. These variables, being intrinsic properties of the materials or the clinical technique used, can cause changes in the size and shape of the definitive restoration. Even if all variables are controlled carefully, the seating of a restoration can still be affected due to insufficient space for the luting agent. The use of die spacer can reduce the elevation of a cast restoration of a prepared tooth, decreased seating time, improve the outflow of excess cement, and lower the seating forces. The purpose of this study was to evaluate the marginal fidelity according to die spacer application times and measurement site. Casting alloys were prepared and fabricated using non-precious metal at $950^{\circ}C$. Specimens are divided into four groups: I(die spacer painted casting for wax pattern), II(die spacer non painted casting for wax pattern). The specimens were cut and polished for marginal gap observation. The marginal gap was observed using scanning electron microscopy (SEM).