• Title/Summary/Keyword: luminescence identification

Search Result 28, Processing Time 0.046 seconds

Properties of Pulsed Photostimulated Luminescence and Thermoluminescence for Detection of Gamma-Irradiated Teas during Storage

  • Kausar, Tusneem;Kim, Byeong-Keun;Yang, Jae-Seung;Byun, Myung-Woo;Kwon, Joong-Ho
    • Preventive Nutrition and Food Science
    • /
    • v.9 no.3
    • /
    • pp.227-231
    • /
    • 2004
  • Green, black and oolong teas were irradiated by $^{60}$ Co-gamma rays (0~10 kGy) and were investigated for detection of irradiation treatment using pulsed photostimulated luminescence (PPSL) and thermoluminescence (TL) during storage. Teas irradiated at 2.5 kGy or more showed a photon count of greater than 5000 counts/60 sec while the non-irradiated yielded only 650~1000 count/60 sec. Correlation coefficients between irradiation dose and photon counts/60 sec were 0.8951, 0.7934 and 0.9007 for green, black and oolong teas, respectively. The TL glow curves for minerals isolated from the non-irradiated teas were situated at about 30$0^{\circ}C$ with a low intensity, but for irradiated samples were approximately 15$0^{\circ}C$ with a high intensity. The TL ratios (TL$_1$/TL$_2$), calculated from values after initial radiation and then after re-irradiation of the teas, were below 0.1 for the non-irradiated samples and higher than 1.44 for all irradiated samples, enhanced the reliability of the identification results for TL. The signal intensity of PPSL and TL for irradiated teas decreased with the lapse of post-irradiation storage time at room temperature but was still distinguishable from that of the non-irradiated samples even after one year.

Physical Detection Properties of Irradiated Wheat and Corn Treated with Different Radiation Sources (방사선 조사선원에 따른 밀과 옥수수의 물리적 검지 특성)

  • Kim, Gui-Ran;Lee, Ju-Woon;Kim, Jeong-Sook;Kwon, Joong-Ho
    • Food Science and Preservation
    • /
    • v.16 no.2
    • /
    • pp.211-216
    • /
    • 2009
  • This study determined the photostimulated luminescence(PSL), thermoluminescence(TL), and electron spin resonance(ESR) properties of wheat and corn irradiated with 0-10 kGy of gamma-ray or electron-beam. PSL values of both irradiated grains, regardless of radiation source, were 241-429 photons/sec in nonirradiated samples(negative values, defined as ${\leq}700$ photons/60 sec) and 5,528-40,870 photons/60 sec in irradiated ones(positive values, defined as ${\geq}5,000$ photons/sec), thereby distinguishing irradiated from nonirradiated samples. The TL glow curves($TL_1$) peaked at around $300^{\circ}C$ in nonirradiated samples, but at about $180^{\circ}C$ in irradiated samples, at high intensities, regardless of radiation source. The TL ratios($TL_1/TL_2$) calculated to strengthen $TL_1$ data reliability were less than 0.03 for nonirradiated samples and over 0.20 for irradiated materials, in good agreement with threshold values for nonirradiated(${\leq}0.1$) and irradiated(${\geq}0.1$) samples. ESR analysis was not applicable in identification of irradiated wheat and corn. Electron-beam irradiation resulted in higher PSL and TL signals than did gamma-rays, at the same applied doses.

Physicochemical Quality and Detection Properties of Irradiated Powdered-Soups (감마선 조사된 분말수프의 이화학적 품질과 조사여부 판별특성)

  • Kwak, Ji-Young;An, Yeoung-Eun;Jung, Bo-Yun;Kwon, Joong-Ho
    • Current Research on Agriculture and Life Sciences
    • /
    • v.30 no.2
    • /
    • pp.82-89
    • /
    • 2012
  • Commercial powdered soups, such as potato soup(PS), corn soup(CS), and chicken-herb soup(CHS), were gamma-irradiated at 0, 1, 5 and 10 kGy and subjected to physicochemical evaluation and identification trials by analyzing photostimulated luminescence(PSL), electron spin resonance(ESR), and thermoluminescence(TL). The changes in moisture content and pH of soup samples were negligible upon irradiation. The Hunter's color determinations showed that lightness (L value) decreased and yellowness (b value) increased as the irradiation dose increased in PS sample. The viscosity of irradiated samples was reduced in the order of PS, CS and CHS. The analyses of PSL, ESR and TL were applicable to the identification of irradiated powdered-soups at more than 1 kGy by detecting PSL photon counts/60 sec(over 5000), radiation-induced multicomponents-ESR signal, and typical TL glow curve at $150-250^{\circ}C$.

  • PDF

Identification of Irradiated Seafood Cooking Drips Using Various Detection Methods (수산 자숙액의 방사선 조사 여부 판별 특성 연구)

  • Choi, Jong-Il;Kim, Yeon-Joo;Kim, Jae-Hun;Lee, Ju-Woon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.11
    • /
    • pp.1569-1574
    • /
    • 2011
  • In this study, the identification of the irradiated seafood cooking drips from Hizikia fusiformis, Enteroctopus dofleini and Thunnus thynnus was conducted. The physical detection methods used included photo-stimulated luminescence (PSL) and thermoluminescence (TL), and the chemical detection methods were hydrocarbons analysis. In the PSL study, all seafood cooking drip samples showed 260~510 photon counts; thus, the PSL method could not be used for the detection of irradiated seafood cooking drips. The TL method could be used for the detection of irradiated H. fusiformis and E. dofleini cooking drips. In both cooking drips, the shapes of the glow curves indicated a specific peak at 150$^{\circ}C$~250$^{\circ}C$, which made it possible to identify the irradiated samples. The hydrocarbons derived by gamma irradiation of T. thynnus cooking drip were not detected due to low concentration and inconsistent content of fatty acids in the untreated T. thynnus cooking drip.

Identification of Pre-pasteurization or Pre-irradiation Treatment in Frozen Crushed Garlic Commercially Available in Korean Market (시판 유통 중인 냉동 다진 마늘의 사전 살균 및 조사처리 여부 판별 모니터링)

  • Kim, Hyo-Young;Ahn, Jae-Jun;Kim, Gui-Ran;Jeong, Jin-Hwa;Park, Ki-Hwan;Kwon, Joong-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.10
    • /
    • pp.1673-1681
    • /
    • 2013
  • Five different chopped frozen garlic products samples, three from Chinese and two from Korean origins being commercially available products in Korean market, were used to confirm their pre-pasteurization or pre-irradiation status by screening (direct epifluorescent filter technique/aerobic plate counts, DEFT/APC; electronic nose, E-nose; photostimulated luminescence, PSL) and identification (thermoluminescence, TL; electron spin resonance, ESR) techniques. Some parts of samples were gamma-irradiated at 1 kGy to be used as control samples in irradiation history identification. DEFT/APC and e-nose successfully showed distinct results between the domestic and imported samples. The PSL photon counts of all the unknown samples were less than 700 (negative), while most of 1 kGy-irradiated samples gave PSL photon counts more than 5,000 (positive). The domestic unknown samples produced the TL glow peaks after $300^{\circ}C$ or more, whereas the imported samples showed TL peaks at the range of $240{\sim}250^{\circ}C$. A clear TL glow peak was obtained from all irradiated samples at $150{\sim}250^{\circ}C$. The unknown samples of Chinese origin gave radiation-specific cellulose ESR signal that was not shown by domestic samples. A multiple step of applying the physical analytical methods is recommended for the effective identification of irradiation status on chopped frozen garlic products.

Detection of Different Ratios of Gamma-irradiated Turmeric by Photostimulated Luminescence and Thermoluminescence (방사선 조사된 터머릭의 혼합비율에 따른 Photostimulated Luminescence 및 Thermoluminescence 분석 특성)

  • Lee, Ji-Ae;Chung, Hyung-Wook;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.6
    • /
    • pp.648-652
    • /
    • 2010
  • This study was performed to investigate PSL and TL characteristics for the detection of different ratios of gamma-irradiated turmeric. It was possible to determine PSL and TL of 1- and 10-kGy irradiated turmeric. The TL ratios ($TL_1/TL_2$) of non-irradiated samples were lower than 0.001, while those of irradiated samples were higher than 0.355. In the PSL results, blended samples containing irradiated ingredients showed intermediate values for a 1% blending rate. Furthermore, TL analysis of blended samples seems to offer a promising method for irradiation identification by TL glow curve form and temperature range. The 1- and 10-kGy irradiated samples were able to be detected above a 4% blending rate. However, the TL ratio appeared as a threshold value below 0.1 for irradiated samples. Overall, TL analysis identified 4% blended samples containing gamma-irradiated turmeric.

Quality Evaluation and Physical Identification of Irradiated Dried Fruits (감마선 조사 건조과일의 품질평가 및 물리적 판별)

  • Jung, Jae-Hoon;Jung, Yoonmi;Jo, Deokjo;Kwon, Joong-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.11
    • /
    • pp.1559-1564
    • /
    • 2012
  • Raisins (Thailand), dried mangos (Philippines), and dried figs (Iran) were gamma-irradiated (0~5 kGy), and their quality and detection characteristics were investigated. Microbiological characteristics were at safe levels when samples were irradiated at higher than 3 kGy. In color change after irradiation, dried mangoes were the most sensitive. Photostimulated luminescence (PSL) measurement was not applicable to dried fruits, showing negative or intermediate values for the irradiated samples. Thermoluminescence (TL) measurement was good for dried figs, exhibiting a glow curve in range of $150{\sim}200^{\circ}C$, where the signal intensity was dependent on the irradiation dose. Electron spin resonance (ESR) measurement was suitable for raisins and dried mangos, resulting in dose-dependent radiation-induced sugar radical signals.

A study on the identification of type IIa natural diamonds treated by the HPHT method (HPHT(고온고압)에 의해 처리된 type IIa 천연 다이아몬드의 감별에 관한 연구)

  • 김영출;최현민
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.14 no.1
    • /
    • pp.21-26
    • /
    • 2004
  • Results from PL and Raman spectroscopic analyses of HPHT (high-pressure high-temperature) treated type IIa diamonds are presented, and these spectral characteristics are compared with those of untreated diamonds of similar color and type. We identify a number of significant changes by 325 nm He/Cd laser excitation. Several peaks are removed completely, including H4, H3 system in HPHT treated diamond. The N3 system, however, increased in emission. Also we can find the behaviour of the nitrogen-vacancy related center N-V centers at 575 and 637.1 nm, as observed with 514 nm Ar ion laser excitation. When these centers are present, the FWHM (full width at half maximum) of 637.1 nm luminescence intensities offers a potential means of separating HPHT-treated from untreated type IIa diamonds. The width of 637.1 nm $(N-V)^-$line measured at the position oi half the peak's height are determine to range from 19.8 to $32.1cm^{-1}$ for HPHT treated diamonds.

Identification of Gamma Irradiation of Imported Spice

  • Choi, In-Duck;Kim, Byeong-Keun;Song, Hyun-Pa;Byun, Myung-Woo;Han, Sang-Bae;Suh, Chung-Sik;Kim, Dong-Ho
    • Preventive Nutrition and Food Science
    • /
    • v.9 no.4
    • /
    • pp.317-323
    • /
    • 2004
  • Photostimulated Luminescence (PSL), Electron Spin Resonance (ESR) and Thermoluminescence (TL) analysis were conducted to detect irradiation treatment of imported whole and ground spices. The screening by PSL detected no irradiation treatment, except un the ground thyme and bay leaves which exhibited photon counts in the intermediate level. Irradiation of the two spices was detected after irradiating them at 1.0, 3.0, 5.0 and 10.0 kGy, and then subjecting them to PSL analysis, which resulted in the significantly low photons of non-irradiated spices compared to that at 1.0 kGy, indicating that the photon counts varied depending on the amount of inorganic mineral debris in the spices. To confirm a successful detection by using PSL, ESR and TL methods, some spices were selected, irradiated at 5.0 and 10.0 kGy, and subjected to the detection methods. PSL identified the irradiated spices except the cassia, which showed very weak PSL sensitivity, but was identified by ESR analysis. Also, the ESR and TL exhibited the typical signals induced by irradiation treatment and were able to successfully detect all of the irradiated spices. In addition, we found a positive correlation between the intensity of ESR and TL signals and irradiation doses.

Identification of irradiated soybean with different processing and origin (대두의 가공특성 및 원산지별 조사처리 판별 연구)

  • Jung, Yoo-Kyung;Lee, Hye-Jin;Lee, Ji-Yeon;Choi, Jang-Duck;Kwon, Ki-Sung
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.3
    • /
    • pp.252-257
    • /
    • 2017
  • In this study, the physicochemical properties of irradiated (gamma-ray and electron-beam) soybeans with different processing (dry and powder) and origins (Korea, China, and USA) were investigated and compared. The results of photostimulated luminescence (PSL) screening indicated that all non-irradiated soybeans showed photon counts (PCs) ${\leq}700$, while all irradiated soybeans showed positive values-gamma-ray 5,815-39,591 count/min; electron beam 5,791-60,055 count/min. The results of thermoluminescence (TL) analysis of all irradiated soybeans indicated that the $TL_1$ glow curves exhibited maximum peaks at 150-250. TL ratio of irradiated samples was ${\geq}0.1$; therefore, the clear identification of irradiated samples was guaranteed by analysis of the $TL_1$ curve shape and TL ratios. The results of electron spin resonance (ESR) signal of 3 irradiated and dried soybeans showed two side peaks mutually spaced at 6.0 mT (cellulose radical). Non-specific signal was detected for all irradiated soybean powders; hence, ESR analysis could not be performed.