• Title/Summary/Keyword: luminance contrast

Search Result 164, Processing Time 0.031 seconds

A Study of Negative Waveform in ac PDP during Reset and Address Periods (ac PDP에서의 Reset과 Address 구간에서 Negative Waveform특성에 관한 연구)

  • Eom, Cheol-Hwan;Kang, Jung-Won
    • Journal of the Semiconductor & Display Technology
    • /
    • v.8 no.1
    • /
    • pp.27-31
    • /
    • 2009
  • A characteristic of new waveform, called a negative waveform, was studied during reset and address periods. IR distribution, black luminance and time delay were measured to compare the negative waveform with the conventional positive waveform. Based on the analysis of IR measurement, the negative waveform could accumulate more wall charges than the positive waveform. Also the black luminance of negative waveform was lower than that of positive waveform under the same bias and ramp-slope conditions. During address period, the discharge time lag was measured. The negative waveform was showed 0.25 us faster formative time lag and 0.1 us faster average time lag than those of positive waveform.

  • PDF

Prediction of Contrast and Lighting Energy Saivings in a Small Office Space according to Daylight Conditions (소규모 사무실공간에서 주광조건에 따른 대비효과 및 조명에너지 절약예측)

  • Kim, Soo-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.4
    • /
    • pp.35-43
    • /
    • 2004
  • Illuminance and luminous levels in a small office space due to daylight were calculated to analyze the impact of daylight on contrast and lighting energy savings. Computer simulations were performed for four blind conditions under a clear sky condition. The blind conditions significantly impacted the illuminance an4 luminance level. Visual performance scores were calculated according to the transfer function that uses absolute contrast between target and background surface. The blind condition that had 45 tilted angle toward ground provided good contrast and performance scores. Using a control algorithm of an automated daylight dimming control system lighting energy sayings were predicted. For all blind conditions minimum lighting energy was consumed.

New Address Waveform for Improvement of the Priming Effect and the Contrast Ratio (AC-PDP에서 프라이밍 효과를 이용한 대조비 향상에 관한 연구)

  • Kwon, Shi-Ok;Kim, Ji-Sun;Joung, Bong-Kyu;Hwang, Ho-Jung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.10
    • /
    • pp.1120-1124
    • /
    • 2004
  • Recently, Plasma Display Panel(PDP) has been in the spotlight as one of the next generation flat-panel-display device. However, it has several drawbacks like the low contrast ratio and the low luminance. In this study, a new address waveform is suggested to improve the priming effect and contrast ratio at the address period in the Address Display period Separated(ADS) method. We modified waveform, instead of a conventional waveform, to an address period, for operating on the Plasma Display Panels, which used the conventional gas [He-Ne-Xe〕. When the ramp pulse is added to the address period at the sustain electrode, it is improved on the priming effect and contrast ratio.

Subjective Evaluation of Glare for Blinking and Colors of Vertical LED Lighting (수직형 LED 조명의 색상 및 점멸에 따른 눈부심 주관평가)

  • Jung, Hyun-Ji;Kim, In-Tae;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.22-30
    • /
    • 2015
  • Currently, in South Korea, 'Light Pollution Prevention Act by Artificial Lighting' has been enforced. For advertising lighting, it is limited based on only the light-emitting luminance. Luminance is a concept related to the glare. Not only the luminance of the light source, but also glare is affected depending on some situations like blinking, luminance contrast, background illuminance. This study conducted glare subjective evaluation with brightness, color, and blinking by looking at the LED lighting box. The results showed that the glare indexes were higher about 2 times in a decrease of background illuminance from 100lx to 0lx. The glare index of R, G, B light was higher than that of white light. The average glare index of the blue light was higher about 8 times compared to 2,700K. And the blink rate had little effect on the glare, but it affected the irritation. Therefore, the glare effect of light color and blinking needs to be considered for the standard of luminous environment.

Preliminary Field Test on Daylighting Performance of Perpendicular Light Pipe System (수직형 라이트파이프의 채광성능에 관한 예비평가)

  • Shin, Hae Mi;Park, Hoon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.8 no.1
    • /
    • pp.53-60
    • /
    • 2008
  • The daylighting affects on the human biological cycles and physiological alterations. Daylighting is also an important element in visual comfort and it sometimes influences the quality of vision. Therefore the absence of natural light during the day brings contradictory result. To solve the problems of natural light lack and provide sufficient daylight in interior spaces, it might be necessary to apply some daylighting systems. One of these systems, light pipe system, which is simple, cheep and easily constructed, is very useful to apply for small buildings. The light pipe is simple means of directing daylighting (diffuse and direct lighting)into interior space. In order to application of light pipe system in Korea, it is necessary to optical data of light pipe system. This study aims to evaluate preliminary experiment of the daylighting environment of light pipe system. Light pipe system, that aspect ratio is 1:2(diameter and length), was installed in a windowless mock-up with $27m^2$. The mock-up model was constructed as a prototype of Korean office surface. Illuminance was measured with a Topcon IM-5 Luxmeter to evaluate the distribution of the illuminance on a floor. The indoor and outdoor illuminance and the internal/external illuminance ratio are compared to discuss with in the graphs. Luminance was measured with Radiant imaging Promertric 1400 that is digital photometer to evaluate the distribution of luminance on interior surface. The contrast of luminance is discussed with table and graphs.

The acceptable limit of the contrast ratio of LCD TV based on human visual system

  • Shin, Kwang-Hoon;Moon, Jong-Won;Park, Sun-Ah;Ahn, Ji-Young;Kang, Dong-Woo;Shin, Hyun-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1497-1499
    • /
    • 2007
  • Visual perception experiments were conducted to determine the acceptable limit of the contrast ratio of LCD TV under the watching condition. The results showed that the corresponding contrast ratio should be below 10,000:1 at the 3H(height of screen) distance in the living room environment.

  • PDF

New Driving Method for High Contrast Ratio and Reduction of Reset Period of AC-PDPs

  • Bae, Jeong-Guk;Kim, Joon-Yub
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1187-1190
    • /
    • 2005
  • The ramp reset driving method proposed in [1] has been widely adopted because of its stability and high contrast ratio. However, when the conventional ramp reset method is used in PDPs of higher resolution, the long required time for reset often becomes a problem. In this paper, a new driving method that requires much less reset time and that significantly improves the contrast ratio is introduced. Using this new driving method, the required time for reset could be reduced to 150us from 350us of the conventional ramp reset method, and the contrast ratio is almost infinite because the luminance of the off-cell is almost zero.

  • PDF

Automatic control method of the TFT LCD's Contrast Ratio according to ambient light (주변 조도 변화에 따라서 TFT LCD의 Contrast Ratio를 자동 조절하는 방법)

  • Kim, S.H.;Son, J.S.;Han, K.Y.;Lee, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.125-129
    • /
    • 2005
  • Mobile display는 사용자가 이동하면서 화면을 보기 때문에 주변 luminance의 변화에 따라서 contrast ratio 변화가 심하다. 특히 햇빛 아래에서는 Mobile display의 화면을 알아보기 어렵다. 본 연구에서는 주변 조도가 증가할수록 TFT LCD의 black 휘도의 변화율이 white 휘도 변화율보다 크게 작용하여 전체 contrast ratio(이하 CR)가 크게 감소함올 확인하였다. 또한, 반투과형 LCD는 반사창을 통해서 외부 빛올 반사시키기 때문에 주변 조도가 높아도 일정 수준의 CR은 유지할 수 있다. 그러나 투과형 LCD보다 CR이 낮았다. 본 논문에서는 투과형 TFT LCD에 back light 광원으로 LED를 사용하고, photo diode와 LED drive IC를 이용하여 주변 조도의 광량에 따라서 LCD의 back light LED의 휘도를 3단계 조절할 수 있는 회로를 구성하였다. 이렇게 함으로써 주변 조도에 따라 자동으로 back light 휘도 조절이 가능한 결과을 얻었다.

  • PDF

Enhancement of the Bright Room Contrast Ratio in a Plasma Display Panel (플라스마 디스플레이 패널에서 명실 콘트라스트 개선)

  • Moon, C.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.1
    • /
    • pp.28-35
    • /
    • 2010
  • A new electrode structure in a plasma display panel was designed in a way to increase the bright room contrast ratio (BRCR). The area of the black matrix pattern to get a low reflection from the panel surface was enlarged using the new electrode design concept. The electrical characteristics such as firing voltage, voltage margin and power consumption were measured. The luminance of the panel was measured and the luminous efficiency was calculated. It was found that the new electrode structure was very effective to enhance the BRCR.

A adaptively robust method of DCT-based watermarking (DCT 기반 워터마킹의 적응적 강인화 방법)

  • Jun, Young-Min;Kim, Gye-Young;Choi, Hyung-Il
    • The KIPS Transactions:PartB
    • /
    • v.10B no.6
    • /
    • pp.629-638
    • /
    • 2003
  • In this paper, we propose an improved method of watermarking to increase the invisibility of a watermark and robustness against attacks for the purpose of removing the embedded watermark. The proposed method adaptively selects DCT blocks and determines position and intensity for watermarking based on the characteristics of human visual system. The used features are texture, luminance and contrast. We show the experimental results against image processing attacks such as cropping, image enhancement, low pass filtering, and JPEG compression, and then discuss the performance of the proposed method.