• Title/Summary/Keyword: luminaire

Search Result 121, Processing Time 0.024 seconds

A Study on the Combination of Household Interior Space Application Using Carved Ceramic Candlestick with the Motive of Yeonga (연가를 모티브로 한 도자 투각 촛대와 이를 이용한 주거 실내공간 인테리어 활용 융합방안에 관한 연구)

  • Kim, Seung Man
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.5
    • /
    • pp.472-481
    • /
    • 2018
  • The main point of this paper is to examine the composition of interior space of the residence centered on carved ceramic candlestick with the motive of Yeonga. And with the Yeonga candlestick developed using that, the application of space convergence in the interior design is researched. As the industry develops, pleasant and comfortable living environment draws attention in choosing residence with the psychology to engage nature into the house working. It is anticipated that the Yeonga candlestick interior accessories will be used to smoothly connect floor, wall and ceiling. As the shape of Yeonga includes the aura of the luminaire, the design element of Yeonga is researched through it. These sources are applied to the carved candlestick to investigate their application as indoor lighting. It is also a major viewpoint to develop this as a ceramic product and actively utilize it as a necessary interior item in daily life.

A Study on the Heat Radiation of LED Luminaires and the Indoor Temperature Increase (LED 등기구의 발열과 실내온도 상승에 관한 연구)

  • Kim, Dong-Geon;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.9
    • /
    • pp.738-742
    • /
    • 2012
  • This paper conducted a study on how the heat radiation of light emitting diode(LED) luminaires affects the indoor temperature increase. The effect was compared with that of a 20 W compact fluorescent lamp(CFL) and a 50 W MR16 halogen lamp which are most widely used inside of cruises, a LED downlight and a 4W MR16 LED replacing each of them. We installed a luminarie inside a thermally shielded chamber, measuring the temperature changes under the same volume every 5 minutes and compared the result with theoretically calculated heat radiation. The temperature changes in the chamber was measured four times, on seven hours' period in order to keep sufficient time once the temperature reaches the thermal equilibrium state. The results showed that the temperature of the 20 W E26 CFL and the 10 W LED downlight increased by $21.1^{\circ}C$ and $10.4^{\circ}C$ respectively, while that of the 50 W halogen MR16 and the 4 W LED MR16 increased by $33.9^{\circ}C$ and $4.8^{\circ}C$ respectively. The experimental heat radiation were calculated from the results and the experimental heat radiation of the CFL and the LED downlight were 171.5 cal and 86.5 cal, and those of the halogen MR16 and the LED MR16 were 275.3 cal and 36.5 cal. Therefore, the heat radiation was reduced by 49.5% and 86.7%, respectively, by replacing conventional light source with LED. In conclusion, we can expect a reduction of power consumption in air condition system and the effect on indoor temperature increase by application of LED luminaires.

Dimming Control of the LED Luminaire Emergency Exit Sign Operation using a Hybrid Super Capacitor of DC-DC Convertor (하이브리드 슈퍼커패시터 DC-DC 컨버터를 이용한 LED 비상 유도등 동작 디밍 제어)

  • Hwang, Lark-Hoon;Kim, Jin-Sun;Na, Yong-Ju
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.3
    • /
    • pp.220-229
    • /
    • 2017
  • In this paper, To take advantage a variety of DC power as the boost DC-DC converter design specifications through the inductor L and capacitor C through PSPICE to calculate the best estimate of the value. Boost DC-DC converter with a switch device using IRF840 and reverse recovery time Schottky diodes with excellent with constant current controller using D10SC6M and resistance can be configured to considering the Power LED Module was driven by the production. Converter's switching frequency is 50 kHz, the first Duty Rate was made to increase gradually depending on the value of the detection were, 10 % in the output voltage. As a result, the simulated Boost Power LED driver characteristics is in comparison with the design specifications, 5% or less as the error was approximated. Finally, when input 15 V were offered, a stable output 24 V were obtained. and Dimming Control through the adjustment of brightness and current consumption were possible.

Characteristic of VSI Driven by Source Synchronous Type for the Utility Interactive using a Photovoltaic Generation for the LED Luminaire Emergency Exit Sign Operation (LED 비상 유도등 동작을 위한 태양광발전 계통연계 전원동기 방식의 전압형 인버터 구동 특성)

  • Hwang, Lark-Hoon;Na, Yong-Ju
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.5
    • /
    • pp.420-428
    • /
    • 2018
  • In this paper, represented uninterruptible power supply (UPS) equipment maintaining constant output voltage, the proposes a photovoltaic system constructed with a step up boosting chopper and single phase pulse width modulation (PWM) voltage source inverter. as power source disconnection, voltage variation and output current variation with load variation. This system is driven by being synchronized voltage fed inverter and AC source, and in the steady state of power source charge battery connected to DC side with solar cell using a Photovoltaic that it was so called constant voltage charge. It can be results of saving electric power, and through a normal operation of energy storage system (ESS), the system operated the LED a calling on signal changes at the airport in an efficient manner. In addition, better output waveform was generated because of PWM method, and it was proved to test by experiment maintained constant output voltage regardless of AC source disconnection, load variation, and voltage variation of AC power source.

Study on the Development of LED streetlight control system using GPS satellite communication and Arduino (GPS 위성통신과 아두이노를 이용한 에너지 절약형 LED 가로등 제어 시스템 개발에 관한 연구)

  • Lee, Wan-Bum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.632-637
    • /
    • 2016
  • A streetlight control system was developed using information technology and LED lights for efficient management and energy savings. The proposed system can control the power usage of an LED streetlight luminaire using GPS satellite communication and an Arduino with a built-in microprocessor. A control circuit was designed to control the current using GPS, a control unit, transistor, resistor, and constant-current supply circuit. The circuit was validated through experiments with normal operation. Using GPS, the control system extracts accurate time and location information according to the season, and it controls the current supplied to the LED streetlight according to the extracted time. Power consumption was reduced by more than 11%. The control system could reduce accidents caused by conventional lighting systems used to save energy, and it could improve the inefficient management of energy by preserving constant brightness of a streetlight at times and in areas that have less traffic.

Conceptual Design for Lifetime Test System for LED Headlamps on Rolling Stock (철도차량용 LED전조등의 수명시험 장치 구축을 위한 개념설계)

  • Ohn, Jung-Ghun;Jeong, Ki-Seok;Chung, Jong-Duk
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.2
    • /
    • pp.111-116
    • /
    • 2015
  • LED luminaires as a lighting system have attracted much research attention due to their high efficiency and long lifetimes. However, disappointing outcomes have been noted in terms of performance levels and lifetimes as compared to desired system requirements in practice due to certain electrical and thermal characteristics of LEDs. LM-80 and TM-21 established by IESNA are the best known standards for lifetime test procedures and estimation techniques. However, they only handle LED light sources without guaranteeing the LED luminaire in a reliability test. They also operate for more than 6,000 hours and undergo various stresses, such as the operating current and temperature. Therefore, a lifetime standard for LED luminaires has not yet been established. This paper proposes a conceptual design of a lifetime test system for LED headlamps depending on the operating environment. Eventually, this method can assist with evaluations of the validity of lifetime standard tests of LED headlamps.

Predicted Performance of the Integrated Artificial Lighting System in Relation to Daylight Levels (채광시스템과 인공조명설비의 통합기술 및 성능평가연구)

  • Kim, G.;Kim, J.T.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.3
    • /
    • pp.47-56
    • /
    • 2002
  • The office is an excellent candidate for implementing daylighting techniques because of the relatively high electric lighting power densities and long daytime use pattern. The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an office interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed for both a totally open-plan office interior and a partitioned office. A lighting design and analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting fixture to meet the designed lighting level and calculates unit power density, which translates the demanded amount of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky are evaluated by a computer software, ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year. A 25 % of electric energy for cooling may be saved by dimming and turning off the luminaires in the perimeter zones.

Analysis of the Electrodeless Fluorescent Lamps' Radio Interference Characteristics by Operating Frequencies and Structures (무전극 형광등 시스템의 구동 주파수 및 방식에 따른 특성 분석)

  • Mok, Jin-Dam;Jeon, Sang-Bong;Park, Seung-Keun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.45-48
    • /
    • 2011
  • The electrodeless fluorescent lamp is relatively new luminaire and has been known as the high energy saving lamp which has long life and environment-friendly. But these kind of lamps have some risks to cause harmful radio interference unavoidably due to its own inductive characteristics. In this paper we measured the radio disturbance characteristics of the induction lamp with the operating frequency at 250 kHz, and compared the values with the limits of relevant standards. Finally we have estimated the interference protection distance between the induction lamps and some services around their operating frequencies, and considered the desirable future scopes and limits of the applications for these kind of lamps.

  • PDF

Building Energy Savings due to Incorporated Daylight-Glazing Systems (통합 채광시스템의 건물 냉난방 에너지 성능평가)

  • Kim, Jeong-Tai;Ahn, Hyun-Tae;Kim, Gon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.1-8
    • /
    • 2005
  • The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an once interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed and the lighting analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting future to meet the designed lighting level and calculates unit power density, which translates the demanded met of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky m evaluated by computer software ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year A 25[%] of electric energy for cooling and almost all off heating energy may be saved by dimming and turning off the luminaires in the perimeter zones.

A Study on the Development of LED Spot Luminaire for Image Lighting (영상조명용 144[W] LED 스폿 등기구 개발에 관한연구)

  • Lee, Jang-Weon;Im, Jee-Weon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.5
    • /
    • pp.271-276
    • /
    • 2010
  • This study manufactured spot lighting fixtures for the broadcasting stage and LED lighting fixtures, measured the illumination, dimming, and color temperature, and installed LED lighting and spot Fresnel lighting to the camera by turns with the same subject to confirm and look into the possibility of replacement of LED lighting fixtures by shooting the figures and comparing them. The analysis of the photographed subject found that the lighting apparatus of LED 144[W] was superior to the tungsten halogen illuminator of 1 [kW] in terms of brightness and color of an image. The measuring of the energy used in 144 [W] LED lighting equipment and tungsten halogen 1[kW] lighting equipment suggested that LED saved more than 80 [%] of energy in the same intensity of illumination. The comparison of the light distribution and light intensity distribution of halogen tungsten illuminator of 1[kW] and LED 144[W] lighting apparatus found that when a subject received concentrated lighting, effective lighting is possible because the illumination intensity on the surface of the lighted subject was high. In performance halls or studios of about 6 [m] height, there is no problem of illumination intensity in LED 144 [W] illuminator. Therefore, it is possible to replace the existing tungsten halogen 1 [KW] illuminator one to one.