• 제목/요약/키워드: lower infrastructure

검색결과 317건 처리시간 0.024초

국가 기상기술력 수준 평가 - 한국, 미국, 일본을 대상으로 한 비교 연구 - (Capability Assessment on Meteorological Technology - Comparative Study of Technological Prowess on Korea, U.S., and Japan -)

  • 김세원;박길운;조창범;이영곤;임덕빈
    • 대기
    • /
    • 제21권3호
    • /
    • pp.319-336
    • /
    • 2011
  • The objective of this study was to assess the meteorological capability of Korea by comparing with that of the U.S. and Japan as of 2010. The research was conducted based on various indices and surveys, and quantified the results using the Gordon's scoring model. The index assessment used 11 items derived from 9 segments - surface observation, advanced observation and observations quality in the observation field; data assimilation, numerical model and infrastructure in the data processing field; forecast accuracy in the forecast field; climate prediction and climate change in the climate field - in this research, we classified the meteorological technology into four fields. In the survey assessment, another 10 items in addition to the above 11 ones (total 21 items) were used. In the field of climate, Korea was found to lag far behind the U.S. (96.5p) and Japan (90.5p) with 77.6 points out of 100, which is 18.9 and 12.9 points lower than them respectively. On the other hand, Korea showed the narrowest gap with Japan (95.3p) and the U.S. (94.2) in the forecasting field, recording 90.3 points. Particularly, in surface observation, infrastructure and forecast accuracy segment, Korea was on a par with the U.S. and Japan, boasting 100.5 percent compared to their counterparts. However, in advanced observation, data quality and climate change segment, Korea was only at the level of 81.5 percent compared to that of the U.S. and Japan. All in all, the technological prowess of Korea, scoring 84.6 points, stood at 89.7 percent of that of the U.S. (94.3p) and 91.9 percent of Japan (92.1p).

토목공사의 BIM 현황 및 활성화에 관한 연구 (The Current Status and Facilitation Strategy of BIM for Civil Infrastructure Projects)

  • 박태순;박희성
    • 대한토목학회논문집
    • /
    • 제38권1호
    • /
    • pp.133-140
    • /
    • 2018
  • 본 논문은 건설업에서 전 생애주기 동안 생성되는 정보와 업무 등을 통합 및 관리할 수 있는 BIM (Building Information Modeling)에 관해 국내 토목분야에서 BIM기술의 현황과 활성화를 위한 방안의 기초자료 제공을 목적으로 수행하였다. 이를 위해 토목분야와 건축분야의 실무자를 대상으로 국내 건설업의 BIM 적용 현황, 실무자 인식조사, 활성화 방안을 위한 계층 분석을 실시하였다. 설문조사 결과 BIM 활성화 저해요인, 단계별 업무에 따른 BIM의 필요성, BIM 적용 시 효과 등과 향후 BIM의 발전 가능성에 대한 질문들은 비슷한 경향을 나타냈다. 토목분야는 건축분야에 비해 BIM의 활용 현황, 기술 교육 정도 등이 낮은 것으로 나타났다. BIM의 활성화 방안을 위한 AHP (Analytic Hierarchy Process) 분석 시에는 재무적, 운영적, 투자적, 기술적, 제도적인 부문별로 중요도에 따른 순위 결과 기술적인 부문이 중요하게 나타났다. 본 연구결과는 BIM의 현황 및 활성화를 위한 분석 결과를 기반으로 효율적인 방안을 제시함으로써 향후 토목분야에 BIM 적용 시 기본방향을 위한 연구에 활용될 수 있다.

금강유역 대형댐 하류 하도지형 경년변화 및 하상재료 종적변이 연구 (Temporal Adjustment of Channel Geometry and Spatial Changes in Riverbed Materials along the Downstream Channels of Large Dams in the Geum River basin)

  • 옥기영;최미경;박형근
    • Ecology and Resilient Infrastructure
    • /
    • 제6권4호
    • /
    • pp.287-294
    • /
    • 2019
  • 대형댐 하류의 수용생태계에서는 상류로부터 공급되는 유기물과 토사 이동의 양적 단절과 질적 변환에 따라 서식처의 물리화학적 교란이 발생하게 된다. 본 연구는 금강 중상류역을 대상으로 대형댐에 의한 하상재료와 토양의 종적변화, 그리고 대형댐 건설 이후 하류 하천의 하도지형 변화를 정량적으로 파악하였다. 댐 상·하류 하상재료 입도분석 결과, 용담댐 구간은 상·하류 모두 호박돌, 굵은자갈로 조립화되어 있었으며, 대청댐 구간은 댐하류에서 중간입경이 가는자갈로 급격히 감소하고 모래비율이 급격히 증가하였다. 토양유기물은 두 개의 댐 모두 하류에서 뚜렷하게 증가하였다. 고지도와 항공사진을 이용하여 대청댐 하류의 하도지형을 분석한 결과, 사주면적의 감소와 사주 내 식생비율의 급격한 증가, 사행도와 저수로폭의 감소 경향을 정량적으로 파악할 수 있었다. 이러한 결과들은 댐 건설에 따른 서식처 변화의 인과관계를 파악하여 댐 하류 조절하천의 자연성을 회복하기 위한 복원관리 방안을 도출하는데 적용될 수 있을 것이다.

팔당호의 수리 및 수온 조사를 통한 물순환특성 분석 (Analysis of Water Circulation Characteristics for Hydraulic and Water Temperature Investigation in Paldang Reservoir)

  • 최황정;조용철;유순주;송용식;류인구
    • Ecology and Resilient Infrastructure
    • /
    • 제6권1호
    • /
    • pp.12-22
    • /
    • 2019
  • 본 연구에서는 팔당호 내 주요지점에서 수심별 연속 수리 및 수온 조사를 수행하여 팔당호의 시공간적 물순환 특성을 파악하고자 하였다. 이포보와 청평댐에서의 수온 및 방류 패턴의 차이로 인하여 팔당호 내 북한강 및 남한강 구간에서의 흐름 및 수온 변동특성이 상이하게 나타났다. 수직혼합기에는 북한강과 남한강 구간의 전 층에서 하류방향 흐름이 우세하게 나타났다. 성층형성기에 이포보 방류수의 수온이 청평댐 방류수의 수온보다 높았으며, 이로 인해 북한강 하류 구간에서 표층은 상대적으로 고온수가 위치하여 상류방향 흐름으로 배수 현상이 나타나고 수렴대가 형성되었다. 남한강 하류 구간은 중층과 저층에서 저온수가 분포하여 상류방향 흐름이 나타나고 표층과 혼합되기 어려운 이층류 구조를 나타내었다.

국내 연속류 자전거도로의 차두시간 분포 모형 개발 (Development of a Time Headway Distribution Model for Uninterrupted Traffic Flow Bikeway in Korea)

  • 전우훈;이영인;양인철
    • 한국ITS학회 논문지
    • /
    • 제18권5호
    • /
    • pp.79-90
    • /
    • 2019
  • 본 연구에서는 국내의 연속류 자전거도로에 대한 차두시간 분포 모형을 개발하고자 하였다. 현장조사를 통해 수집된 데이터를 교통량으로 구분하여 분석하였으며, 교통량의 기준은 전체 교통량을 분포를 고려하여 1분당 8대 미만은 낮은 수준의 교통량으로 하고 8대 이상은 높은 수준의 교통량으로 구분하였다. 차두시간의 집계간격은 기존의 자동차교통류에서 일반적으로 적용해오던 0.5초를 적용하였다. 적용된 분포는 기본적인 정규분포와 함께 음지수분포, 전이된 음지수분포, 피어슨 III분포이며, 카이스퀘어 검정 분석결과 음지수분포와 전이된 음지수분포에서 방향과 교통량 구분 모두에서 이론치와 관측치간에 적합한 것으로 나타났다. 제시된 자전거 차두시간 분포모형의 적정성을 판단하기 위한 분석결과, 역시 동일하게 음지수분포와 전이된 음지수분포가 적합한 것으로 나타났다.

Centrifuge modelling of rock-socketed drilled shafts under uplift load

  • Park, Sunji;Kim, Jae-Hyun;Kim, Seok-Jung;Park, Jae-Hyun;Kwak, Ki-Seok;Kim, Dong-Soo
    • Geomechanics and Engineering
    • /
    • 제24권5호
    • /
    • pp.431-441
    • /
    • 2021
  • Rock-socketed drilled shafts are widely used to transfer the heavy loads from the superstructure especially in mountainous area. Extensive research has been done on the behavior of rock-socketed drilled shafts under compressive load. However, little attention has been paid to uplift behavior of drilled shaft in rock, which govern the overall behavior of the foundation system. In this paper, a series of centrifuge tests have been performed to investigate the uplift response of rock-socketed drilled shafts. The pull-out tests of drilled shafts installed in layered rocks having various strengths were conducted. The load-displacement response, axial load distributions in the shaft and the unit skin friction distribution under pull-out loads were investigated. The effects of the strength of rock socket on the initial stiffness, ultimate capacity and mobilization of friction of the foundation, were also examined. The results indicated that characteristics of rock-socket has a significant influence on the uplift behavior of drilled shaft. Most of the applied uplift load were carried by socketed rock when the drilled shaft was installed in the sand over rock layer, whereas substantial load was carried by both upper and lower rock layers when the drilled shaft was completely socketed into layered rock. The pattern of mobilized shaft friction and point where the maximum unit shaft friction occurred were also found to be affected by the socket condition surrounding the drilled shaft.

고랭지밭 밀집지역 초생대의 비점오염 저감 효율 평가 - 비점오염원 관리지역을 중심으로 (만대지구, 가아지구, 자운지구) - (Efficiency Evaluation of Vegetative Filter Strip for Non-point Source Pollutant at Dense Upland Areas - Focused on Non-point Source Management Area Mandae, Gaa, and Jaun Basins -)

  • 정연지;이동준;강현우;장원석;홍지영;임경재
    • 한국농공학회논문집
    • /
    • 제64권4호
    • /
    • pp.1-10
    • /
    • 2022
  • A vegetative filter strip (VFS) is one of the best management practices (BMPs) to reduce pollutant loads. This study aims to assess the effectiveness of VFS in dense upland field areas. The study areas are agricultural fields in the Maedae (MD), Gaa (GA), and Jaun (JU) watersheds, where severe sediment yields have occurred and the Korean government has designated them as non-point management regions. The agricultural fields were divided into three or four clusters for each watershed based on their slope, slope length, and area (e.g., MD1, MD2). To assess the sediment trapping (STE) and pesticide reduction efficiency (PRE) of VFS, the Vegetative Filter Strip Modeling System (VFSMOD) was applied with three different scenarios (SC) (SC1: VFS with rye vegetation; SC2: VFS with rye vegetation and a gentle slope in VFS range; and SC3: VFS with grass mixture). For SC1, there were relatively short slope lengths and small areas in the MD1 and GA3 clusters, and they showed higher pollutant reduction (STE>50%, PRE>25%). For SC2 and SC3, all clusters in GA and some clusters (MD1 and MD3) in MD show higher pollutant reduction (>25%), while the uplands in JU still show a lower pollutant (<25%). With correlation analysis between geographic characteristics and VFS effectiveness slope and slope length showed relative higher correlations with the pollutant efficiency than a area. The results of this study implied that slope and slope length should be considered to find suitable upland conditions for VFS installations.

재발성 칸디다성 외음질염의 한약치료 효과에 관한 무작위 대조 연구 문헌고찰 (Review of Randomized Controlled Trials of Oriental Medicine for Recurrent Vulvovaginal Candidiasis)

  • 채민수;박승혁;황덕상;이진무;이창훈;장준복
    • 대한한방부인과학회지
    • /
    • 제33권2호
    • /
    • pp.29-43
    • /
    • 2020
  • Objectives: The purpose of this study is to review and evaluate the effectiveness of oriental medicine per oral for recurrent vulvovaginal candidiasis (RVVC). Methods: We searched articles from Korean journal databases including Journal of Korean Obstetrics and Gynecology, Korean studies Information Service Studies, and Chinese National Knowledge Infrastructure, Cochrane Library, PubMed. Searched keywords were "재발성 칸디다성 외음질염", "recurrent vulvovaginal candidiasis", "㚆发性外阴阴道假丝酵母菌病", "中藥". Results: 10 randomized controlled trials with 700 patients were identified and reviewed. 8 studies compared combination of oriental medicine and anti-fungal agent with anti-fungal agent, and 6 of them reported that treatment group (TG) showed statistically higher total effective rate or cure rate and lower recurrence rate. One study compared oriental medicine and anti-fungal agent and TG showed statistically higher total effective rate and lower recurrence rate after 1 month. One study compared combination of oriental medicine and lacto bacillus capsule with lacto bacillus capsule, and TG showed statistically higher total effective rate and lower positive fungul test rate after 6 months. No severe adverse response was reported. Conclusions: Our review found that oriental medicine per oral is effective for alleviating symptoms, lowering recurrence rate and positive fungal test in RVVC patients. We recommend standardized randomized controlled trial guideline should be made to obtain stronger evidence and well designed trials with larger sample sizes are needed.

U-플랜지 트러스 보의 구조 내력에 관한 실험 연구 (Experimental Study on the Structural Capacity of the U-Flanged Truss Steel Beam)

  • 오명호;김영호;강재윤;김명한
    • 한국공간구조학회논문집
    • /
    • 제18권4호
    • /
    • pp.113-121
    • /
    • 2018
  • U-flanged truss beam is composed of u-shaped upper steel flange, lower steel plate of 8mm or more thickness, and connecting lattice bars. Upper flange and lower plate are connected by the diagonal lattice bars welded on the upper and lower sides. In this study the structural experiments on the U-flanged truss beams with various shapes of upper flange were performed, and the flexural and shear capacities of U-flanged truss beam in the construction stage were evaluated. The principal test parameters were the shape of upper flange and the alignment space of diagonal lattice bars. In all the test specimens, the peak loads were determined by the buckling of lattice bar regardless of the upper flange shape. The test results have shown that the buckling of lattice bar is very important design factor and there is no need to reinforce the basic u-shaped upper flange. However, the early lattice buckling occurred in the truss beam with upper steel bars because of the insufficient strength and stiffness of upper chord, and the reinforcement in the upper chord is necessary. The formulae of Eurocode 3 (2005) have presented more exact evaluations of lattice buckling load than those of KBC 2016.

전기 소형화물차 구매보조금의 적정 수준에 대한 연구 환경편익과 TCO-parity를 중심으로 (A Study on the Appropriate Level of Electric Light Duty Vehicle Purchase Subsidies)

  • 이동규;전호철
    • 자원ㆍ환경경제연구
    • /
    • 제33권1호
    • /
    • pp.33-57
    • /
    • 2024
  • 본 연구는 전기 소형화물차에 대한 구매보조금이 환경편익의 측면과 총보유비용 동등성 측면에서 볼 때 적정한 수준인지에 대하여 분석하였다. 환경편익에 대해서는 발전믹스에 따라 발생하는 환경오염물질 배출량을 고려하였으며, 기온분포에 따른 전기차의 효율변화도 반영하였다. 소형화물차의 경우, 경유차 대신 전기차를 운행함에 따른 환경편익은 차량의 총운행기간에 걸쳐 217~530만 원 수준으로 추정되었다. 또한, 현행 구매보조금 제도하에서 경유차 대비 전기차의 총보유비용은 사업용은 약 360만 원, 비사업용은 약 660만 원 낮은 것으로 추산되었다. 즉, 환경편익의 관점에서든 총보유비용의 관점에서든 보다 효율적으로 재정을 활용하고자 한다면 같은 예산이라도 전기 소형화물차에 대한 구매보조금 단가를 낮추는 것이 합리적이다. 그 대신 남은 예산은 화물차 전용 충전기의 확보와 같이 충전인프라를 고도화하는 데에 좀 더 집중한다면 잠재적인 구매자들의 금전적인 부담뿐만 아니라 충전 관련 불편함까지 줄여 전기 소형화물차 보급에 더 비용효과적일 것으로 판단된다.