• Title/Summary/Keyword: lower drop

Search Result 650, Processing Time 0.029 seconds

Biofilter Treatment of Waste Air Containing Malodor and VOC: 1. Pressure Drop and Microbe-population Distribution of Biofilter with Improved Design (악취 및 VOC를 함유한 폐가스의 바이오필터 처리: 1. 개선된 바이오필터설계에 의한 압력강하와 미생물 population 분포)

  • Lee, Eun Ju;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.51 no.1
    • /
    • pp.127-135
    • /
    • 2013
  • In this study, both pressure drop and microbe-population-distribution were observed while running a novel biofilter system with improved design in which the biofilter system is composed of two, upper and lower biofilters with both equal feed-rates of up-flow and down-flow, respectively. Then they were compared with the pressure drop and microbe-population-distribution observed in a conventional biofilter of the same effective volume with unidirectional flow. The pressure drop-value of biofilter system with improved design turned out to be less at the incipient stage of run or steady-state long term operation by more than 40~80% of that of the conventional biofilter. The microbe-population-distribution was observed to be lower and higher at higher and lower column of biofilter, respectively, for both the conventional biofilter and the biofilter system with improved design. The microbe-media of waste-tire crumb showed much greater CFU counts than GAC. In the biofilter system with improved design, the $bottom{\rightarrow}up$ feeding of waste air showed greater microbe-population growth than the $top{\rightarrow}down$ feeding for both the microbe-media of waste-tire crumb and GAC. However, it was more prominent for the former than the latter. Comparing the microbe-population-distributions of both of the conventional biofilter and the biofilter system with improved design, the microbe-population of latter was distributed ca. 15 and 2.5 times more evenly for GAC and the media of waste-tire crumb, respectively, than that of former.

Biomechanical Effects of Wearing Mouthguards during Drop Landing (드롭 착지동작 시 마우스가드 착용이 운동역학적 변인에 미치는 영향)

  • Chae, Woen-Sik;Lee, Kyu-Bok;Jung, Jae-Kwang;Lee, Haeng-Seob;Kim, Dong-Soo;Jung, Jae-Hu
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.4
    • /
    • pp.347-355
    • /
    • 2013
  • The purpose of this study was to determine the biomechanical effect of wearing the mouthguard on the lower limb during drop landing. Nine male university students who have no musculoskeletal disorder were recruited as the subjects. Linear velocity, angular velocity, vertical GRF, loading rate, joint moment, and lower extremity muscle activity were determined for each subject. For each dependent variable, paired t-test was performed to test if significant difference existed between with mouthguard (WM) and without mouthguard (WOM) conditions (p<.05). The results showed that linear velocity, angular velocity, vertical GRF and loading rate were no significant difference between the two groups. The inversion moment of the ankle joint was increased in WM compared to WOM. Average IEMG values from BF, TA, and LG in WM were significantly greater than corresponding values in WOM during IP phase. This indicates that wearing mouthguard played a vital role in muscle tuning for maintaining joint stability of the lower limb and preventing injury.

Pressure Drop Predictions Using Multiple Regression Model in Pulse Jet Type Bag Filter Without Venturi (다중회귀모형을 이용한 벤츄리가 없는 충격기류식 여과집진장치 압력손실 예측)

  • Suh, Jeong-Min;Park, Jeong-Ho;Cho, Jae-Hwan;Jin, Kyung-Ho;Jung, Moon-Sub;Yi, Pyong-In;Hong, Sung-Chul;Sivakumar, S.;Choi, Kum-Chan
    • Journal of Environmental Science International
    • /
    • v.23 no.12
    • /
    • pp.2045-2056
    • /
    • 2014
  • In this study, pressure drop was measured in the pulse jet bag filter without venturi on which 16 numbers of filter bags (Ø$140{\times}850{\ell}$) are installed according to operation condition(filtration velocity, inlet dust concentration, pulse pressure, and pulse interval) using coke dust from steel mill. The obtained 180 pressure drop test data were used to predict pressure drop with multiple regression model so that pressure drop data can be used for effective operation condition and as basic data for economical design. The prediction results showed that when filtration velocity was increased by 1%, pressure drop was increased by 2.2% which indicated that filtration velocity among operation condition was attributed on the pressure drop the most. Pressure was dropped by 1.53% when pulse pressure was increased by 1% which also confirmed that pulse pressure was the major factor affecting on the pressure drop next to filtration velocity. Meanwhile, pressure drops were found increased by 0.3% and 0.37%, respectively when inlet dust concentration and pulse interval were increased by 1% implying that the effects of inlet dust concentration and pulse interval were less as compared with those changes of filtration velocity and pulse pressure. Therefore, the larger effect on the pressure drop the pulse jet bag filter was found in the order of filtration velocity($V_f$), pulse pressure($P_p$), inlet dust concentration($C_i$), pulse interval($P_i$). Also, the prediction result of filtration velocity, inlet dust concentration, pulse pressure, and pulse interval which showed the largest effect on the pressure drop indicated that stable operation can be executed with filtration velocity less than 1.5 m/min and inlet dust concentration less than $4g/m^3$. However, it was regarded that pulse pressure and pulse interval need to be adjusted when inlet dust concentration is higher than $4g/m^3$. When filtration velocity and pulse pressure were examined, operation was possible regardless of changes in pulse pressure if filtration velocity was at 1.5 m/min. If filtration velocity was increased to 2 m/min. operation would be possible only when pulse pressure was set at higher than $5.8kgf/cm^2$. Also, the prediction result of pressure drop with filtration velocity and pulse interval showed that operation with pulse interval less than 50 sec. should be carried out under filtration velocity at 1.5 m/min. While, pulse interval should be set at lower than 11 sec. if filtration velocity was set at 2 m/min. Under the conditions of filtration velocity lower than 1 m/min and high pulse pressure higher than $7kgf/cm^2$, though pressure drop would be less, in this case, economic feasibility would be low due to increased in installation and operation cost since scale of dust collection equipment becomes larger and life of filtration bag becomes shortened due to high pulse pressure.

Drop formation of Carbopol dispersions displaying yield stress, shear thinning and elastic properties in a flow-focusing microfluidic channel

  • Hong, Joung-Sook;Cooper-White, Justin
    • Korea-Australia Rheology Journal
    • /
    • v.21 no.4
    • /
    • pp.269-280
    • /
    • 2009
  • The drop formation dynamics of a shear thinning, elastic, yield stress ($\tau_o$) fluid (Carbopol 980 (poly(acrylic acid)) dispersions) in silicone oil has been investigated in a flow-focusing microfluidic channel. The rheological character of each solution investigated varied from Netwonian-like through to highly non-Newtonian and was varied by changing the degree of neutralization along the poly (acrylic acid) backbone. We have observed that the drop size of these non-Newtonian fluids (regardless of the degree of neutralisation) showed bimodal behaviour. At first we observed increases in drop size with increasing viscosity ratio (viscosity ratio=viscosity of dispersed phase (DP)/viscosity of continuous phase (CP)) at low flowrates of the continuous phases, and thereafter, decreasing drop sizes as the flow rate of the CP increases past a critical value. Only at the onset of pinching and during the high extensional deformation during pinch-off of a drop are any differences in the non-Newtonian characteristics of these fluids, that is extents of shear thinning, elasticity and yield stress ($\tau_o$), apparent. Changes in these break-off dynamics resulted in the observed differences in the number and size distribution of secondary drops during pinch-off for both fluid classes, Newtonian-like and non-Newtonian fluids. In the case of the Newtonian-like drops, a secondary drop was generated by the onset of necking and breakup at both ends of the filament, akin to end-pinching behavior. This pinch-off behavior was observed to be unaffected by changes in viscosity ratio, over the range explored. Meanwhile, in the case of the non-Newtonian solutions, discrete differences in behaviour were observed, believed to be attributable to each of the non-Newtonian properties of shear thinning, elasticity and yield stress. The presence of a yield stress ($\tau_o$), when coupled with slow flow rates or low viscosities of the CP, reduced the drop size compared to the Newtonian-like Carbopol dispersions of much lower viscosity. The presence of shear thinning resulted in a rapid necking event post onset, a decrease in primary droplet size and, in some cases, an increase in the rate of drop production. The presence of elasticity during the extensional flow imposed by the necking event allowed for the extended maintenance of the filament, as observed previously for dilute solutions of linear polymers during drop break-up.

The Effects of Trunk Exercises on the Balancing Ability of Elderly Hansen's Disease Patients with Lower Extremity Dysfunction (체간운동이 하지기능장애 한센노인의 균형능력에 미치는 영향)

  • Jung, Soon-Mi
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.7 no.1
    • /
    • pp.77-85
    • /
    • 2012
  • Purpose : The purpose of this study was to investigate the effects of trunk exercises on the balancing ability of elderly Hansen's disease patients with lower extremity dysfunction. Method : A total of 24 elderly Hansen's disease patients were divided into two groups: 10 without lower extremity dysfunction and 14 with lower extremity dysfunction. The groups exercised for 60 minutes, two days a week, for a total 12 weeks; balancing ability was measured with the one leg standing test, tandem walking test, and timed up-and-go test. The patients were tested and their results were compared both before and after the completion of their exercise programs. Lower extremity dysfunction was assessed according to the following criteria: unilateral foot-drop, toe-loss, and below-knee amputation. Results : After the exercises, participants in both groups showed a positive, statistically significant difference in balance, compared with before the exercises (the one leg standing test, tandem walking test, and timed up-and-go test; p<.05). For comparison purposes, the group with dysfunction and the group without dysfunction were tested before and after the completion of their exercises. Before the exercises, there was a statistically significant difference in the one leg standing test, tandem walking test, and timed up-and-go test (p<.05). However, after the exercises, there was no significant difference in the one leg standing test, tandem walking test, and timed up-and-go test (p>.05). Conclusion : Ultimately, balancing ability was improved in both of the groups after trunk exercises were performed. Although balancing ability was improved, elements of lower extremity dysfunction remained, such as unilateral foot-drop, toe-loss, and below-knee amputation.

A Study of 3D Virtual Fitting Model of Men's Lower Bodies in Forties by Morphing Technique. (모핑 기법을 활용한 40대 남성 하반신 가상모델 생성에 관한 연구)

  • Park, Sun-Mi;Nam, Yun-Ja;Choi, Kueng-Mi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.3 s.162
    • /
    • pp.463-474
    • /
    • 2007
  • With rapid expansion in e-retailing of apparel business, personalized fitting model service shows the possibility as the differentiated marketing strategy in cyber shopping. According as necessity of personalized fitting model construction rises, it is tried personalized fitting model creation in several fields such as computer engineering, mechanical engineering, information engineering. But, because existent study was concentrated only on human body modeling, it does not reflect average morphological characteristics of human body properly. In this study, we wish to examine if morphing is fit for expressing characteristic of average human body shape and suggest desirable morphing. We used 3-D scan data of 254 Korean middle aged men collected by Size Korea 2004. The result of this study are as follows: Lower body types were categorized by height hip girth and lower drop(hip girth-navel girth) which were main factors of lower body shape. Then each factor was divided into 3 groups respectively, 30% in the middle, over 30%, under 30%. In 27 groups, the group which belonged to 30% in the middle of height, 30% in the middle of hip girth, 30% in the middle of lower drop was selected as a representative group. We tested geometrical figure by differ volume, tilt, position of point. And we created a representative type of men's lower bodies by morphing the representative group and analyzed it's horizontal, vertical sections. A representative type which was created by morphing reflected a real body and changed realistically at the part of hip, crotch, calf muscle and so on. A cross sections of a representative type were similar to average cross sections of the representative group in size and shape. So it was proved that morphing was successful.

Comparisons of Vastus Medialis and Vastus Lateralis Muscle Activities according to Different Heights during Drop Landing in Flatfooted Adults

  • Chang, Jong Sung
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.5
    • /
    • pp.302-306
    • /
    • 2020
  • Purpose: The purpose of this study was to investigate comparisons of vastus medialis (VMO) and vastus lateralis (VL) muscle activities according to different heights during drop landing in flatfooted adults. Methods: Fifteen subjects with a flat foot arch and 15 subjects with a normal feet arch were participated. Subjects performed a double limb drop landing task from 20, 40, and 60 cm heights. Surface electromyography was used to measure the muscle activities of the VMO and VL during drop landing. Results: There were significant differences of muscle activities in the VMO, VL, and the VMO and VL ratio between groups. The electromyography values of VMO, VL, and the VMO and VL ratio in the normal group were significantly greater than in the flat foot group, and muscle activities and the VMO and VL ratio significantly increased with landing heights in the both groups. Conclusion: Our results indicated that muscle activity patterns of VOM and VL in the flat foot group were lower at heights than in the normal group, so calf tightness was negative effects on balance and gait ability, so assessment of muscle activation patterns in the knee extensors should be considered during exercise and treatment of flat feet.

Comparison of Subjects with and without Pes Planus during Short Foot Exercises by Measuring Muscular Activities of Ankle and Navicular Drop Height

  • Park, Du-Jin;Park, Se-Yeon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.13 no.3
    • /
    • pp.133-139
    • /
    • 2018
  • PURPOSE: Despite the abundant literature available regarding the activity of intrinsic muscles, few studies have investigated the muscle activity of extrinsic muscles. Therefore, the present study compared the muscle activity of the peroneus longus, tibialis anterior, and abductor hallucis during short foot exercise in subjects with and without flat feet. METHODS: Twelve subjects with and without pes planus participated in this study. During the short foot exercises, muscular activity of the tibialis anterior, fibularis longus, and abductor hallucis longus were measured in both groups. To identify the effects of short foot exercises, navicular drop height was also investigated in pre and post short foot exercises. RESULTS: In a symptomatic group, the navicular drop height was significantly reduced at post measurement compared with pre-measurement. During the short foot exercise, the pes planus group showed significantly lower activities of the fibularis longus than the control group (p<.05). CONCLUSION: Similar to previous studies and clinical literature, short foot exercise was effective for alleviating navicular drop for a population with pes planus. In addition, subjects with pes planus showed decreased muscular activities of the fibularis longus, which suggests that considering extrinsic muscles such as fibularis longus is also important for rehabilitation of pes planus patients.

Influence of Kinesio Taping of Patient with Foot Drop following CVA (편마비 환자의 족하수에 운동성 테이핑 적용이 보행능력에 미치는 영향)

  • Jung, Sam-Hee;Kong, Se-Jin;Yoon, Jung-Gyu
    • Journal of Korean Physical Therapy Science
    • /
    • v.7 no.2
    • /
    • pp.607-613
    • /
    • 2000
  • Objective: This study is designed to examine how an application of a kinesio taping to the foot drop of a hemiplegic patient affects the functional recovery of a gait. Method: The patient was a man with left hemiplegia of about 11 months' duration. a single subject design (ABAB design) was used to investigate the timing difference at a stance phase between an unaffected side and an affected side in the gait ability of the hemiplegic patient by using the kinesio taping. The study was divided into four phase: an initial base-line, an experimental, a second base-line, and second experimental phase. Result: The timing difference at a stance phase between an unaffected side and an affected side in the gait was decreased in the case of the affected side by following the result of applying the kinesio taping to a lower extremity. Conclusion: The kinesio taping applied to the foot drop of a hemiplegic patient affects the improvement of the gait ability.

  • PDF

Knee Joint Moment during Golf Swing, Drop-landing, and Cutting Maneuver (골프스윙, 드롭랜딩, 컷팅 동작 시 슬관절 모멘트 분석)

  • Kim, Ki-Hyun;Lim, Young-Tae;Park, Jun-Sung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.296-302
    • /
    • 2020
  • The purpose of this study was to assess knee joint loading in the target knee during a golf swing compared to loading rates of high impact activities such as cutting and drop landings. Nine healthy competitive golfers completed golf swings with the target foot both straight and externally rotated 30 degrees, as well as drop landings and cutting maneuvers. Motion capture data was collected at 240 Hz and ground reaction force data was collected at 2400 Hz. The frontal and transverse knee moments were examined using repeated measures ANOVA through SPSS. The abduction moments were higher in golf swings as compared to the other high impact activities (p=.010), while the external rotation moments were lower (p=.003). There were no significant differences between externally rotated and neutral golf swings. These results suggest moments applied to the knee during a golf swing are similar to those applied during a high impact activity.