• 제목/요약/키워드: lower and upper flash points

검색결과 35건 처리시간 0.03초

노말헥사데칸의 화재 및 폭발 특성치의 측정 (The Measurement of Fire and Explosion Properties of n-Hexadecane)

  • 하동명
    • 한국안전학회지
    • /
    • 제29권3호
    • /
    • pp.39-45
    • /
    • 2014
  • For the safe handling of n-hexadecane, the lower flash points and the upper flash point, fire point, AITs(auto-ignition temperatures) by ignition delay time were experimented. Also lower and upper explosion limits by using measured the lower and upper flash points for n-hexadecane were calculated. The lower flash points of n-hexadecane by using the Setaflash and the Pensky-Martens closed testers were measured $128^{\circ}C$ and $126^{\circ}C$, respectively. The lower flash points of the Tag and the Cleveland open cup testers were measured $136^{\circ}C$ and $132^{\circ}C$, respectively. The fire points of the Tag and the Cleveland open cup testers were measured $144^{\circ}C$. respectively. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 apparatus for n-hexadecane. The experimental AIT of n-hexadecane was $200^{\circ}C$. The calculated lower and upper explosion limit by using measured lower $128^{\circ}C$ and upper flash point $180^{\circ}C$ for n-hexadecane were 0.42 Vol.% and 4.70 Vol.%.

노말펜타데칸의 화재 및 폭발 특성치의 측정 (The Measurement of Fire and Explosion Properties of n-Pentadecane)

  • 하동명
    • 한국안전학회지
    • /
    • 제28권4호
    • /
    • pp.53-57
    • /
    • 2013
  • For the safe handling of n-pentadecane, the lower flash points and the upper flash point, fire point, AITs(auto-ignition temperatures) by ignition delay time were experimented. Also lower and upper explosion limits by using measured the lower and upper flash points for n-pentadecane were calculated. The lower flash points of n-pentadecane by using closed-cup tester were measured $118^{\circ}C$ and $122^{\circ}C$. The lower flash points and fire point of n-pentadecane by using open cup tester were measured $126^{\circ}C$ and $127^{\circ}C$, respectively. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 apparatus for n-pentadecane. The experimental AIT of n-pentadecane was $195^{\circ}C$. The calculated lower and upper explosion limit by using measured lower $118^{\circ}C$ and upper flash point $174^{\circ}C$ for n-pentadecane were 0.54 Vol.% and 6.40 Vol.%.

노말테트라데칸의 연소특성치 측정에 의한 위험성 평가 (The Evaluation of Hazard by Measurement of Combustible Characteristics of n-Tetradecane)

  • 하동명
    • 한국안전학회지
    • /
    • 제27권5호
    • /
    • pp.70-76
    • /
    • 2012
  • For the safe handling of n-tetradecane, the lower flash points and the upper flash point, fire point, AITs (auto-ignition temperatures) by ignition delay time were experimented. Also lower and upper explosion limits by using measured the lower and upper flash points for n-tetradecane were calculated. The lower flash points of n-tetradecane by using closed-cup tester were measured $104^{\circ}C$ and $112^{\circ}C$. The lower flash points and fire point of n-tetradecane by using open cup tester were measured $113^{\circ}C$ and $115^{\circ}C$, respectively. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 apparatus for n-tetradecane. The experimental AIT of n-tridecane was $207^{\circ}C$. The calculated lower and upper explosion limit by using measured lower $104^{\circ}C$ and upper flash point $140^{\circ}C$ for n-tetradecane were 0.63 Vol.% and 3.18 Vol%.

노말언데칸의 연소특성치의 측정 (The Measurement of Combustible Characteristics of n-Undecane)

  • 하동명
    • 한국화재소방학회논문지
    • /
    • 제27권2호
    • /
    • pp.11-17
    • /
    • 2013
  • 노말언데칸의 안전한 취급을 위해서 하부인화점, 상부인화점, 연소점 그리고 발화지연시간에 의한 발화온도를 측정하였다. 또한 노말언데칸의 하부와 상부인화점의 측정값을 이용하여 폭발하한계와 상한계를 예측하였다. 밀폐식 장치에 의한 노말언데칸의 하부인화점은 $59^{\circ}C$$67^{\circ}C$로 측정되었고, 개방식 장치에 의한 하부인화점은 $67^{\circ}C$$72^{\circ}C$로 측정되었다. 클리브랜브 장치에 의한 노말언데칸의 연소점은 $74^{\circ}C$로 측정되었다. ASTM E659-78 장치를 사용하여 자연발화 온도와 발화지연시간을 측정하였고, 여기서 측정된 최소자연발화온도는 $198^{\circ}C$였다. 측정된 하부인화점 $59^{\circ}C$와 상부인화점 $83^{\circ}C$를 이용하여 예측된 폭발하한계는 0.65 Vol.%, 폭발상한계는 2.12 Vol.%였다.

3성분계 유기용제의 인화특성에 관한 연구 (A Study on the Characteristics of Flammability for Organic Solvents of Three Component Systems)

  • 임우섭;목연수;최재욱;최일곤;하동명;조태제
    • 한국안전학회지
    • /
    • 제14권3호
    • /
    • pp.120-126
    • /
    • 1999
  • This study was accomplished by measuring the lower and upper flash point with air blowing method and grasping the characteristics of flammability for the three component systems, which are made up of the Benzene-Toluene-o-Xylene and Methylethylketone-Toluene-o-Xylene. These three component systems are widely used in the various industrial fields together with the development of industry. The results are as follows ; 1 ) Isothermal line is plotted on the triangular diagram for flash points determined in each solutions. From this line, the mixed compositions which indicated the same lower and upper flash points in each different composition could be read on this diagram, if the composition of mixtures are known. 2) Lower and upper explosion limits obtained from the flash points determined for the three component solution are compared with the value calculated from Le Chatelier's law. Especially the lower explosion limits are in a good agreement with the calculated values.

  • PDF

초산부틸의 화재 및 폭발 특성치 측정 및 예측 (Measurement and Prediction of Fire and Explosion Characteristics of n-Butylacetate)

  • 하동명
    • 한국안전학회지
    • /
    • 제32권5호
    • /
    • pp.25-31
    • /
    • 2017
  • The flash point, explosion limits, autoignition temperature(AIT) are important combustible properties which need special concern in the chemical safety process that handle hazardous substances. For the evaluation of the flammable properties of n-butylacetate, this study was investigated the explosion limits of n-butylacetate in the reference data. The flash points, fire points and AIT by the ignition delay time of n-butylacetate were experimented. The lower flash points of n-butylacetate by using the Setaflash and Pensky-Martens closed-cup testers were $24^{\circ}C$ and $26^{\circ}C$, respectively. The flash points of n-butylacetate using the Tag and Cleveland open cup testers are measured $31^{\circ}C$ and $40^{\circ}C$, respectively. And the fire points of n-butylacetate by the Tag and Cleveland open cup testers were measured $32^{\circ}C$ and $41^{\circ}C$. The AIT of n-butylacetate measured by the ASTM 659E tester was measured as $411^{\circ}C$. The lower explosion limit of lower flash point $24^{\circ}C$, which was measured by the Setaflash tester, was calculated to be 1.40 vol%. Also, the upper explosion limit of upper flash point $67^{\circ}C$ the Setaflash tester was calculated to be 12.5 vol%.

2-프로판올과 톨루엔 혼합물질의 인화점 측정에 관한 연구 (Study on the Flash Point Determination of 2-Propanol-Toluene Mixtures)

  • 목연수;최재욱;김영일;최일곤;하동명
    • 한국안전학회지
    • /
    • 제12권3호
    • /
    • pp.114-119
    • /
    • 1997
  • The lower flash points and upper flash points of 2-propanol and toluene mixtures were determined by air-blowing method instead of Tag-closed flash point tester. The relations between the flash points and the composition of the mixtures are as follows, $T_{F.L}=4.3182+6.0909X_1$ $T_{F.U}=39.3636-2.9091X_1$ As results, the experimental data and the estimated values from the relations are considerably agreed, and we could plotted the relative diagram between flash points and the explosive range.

  • PDF

MSDS 적정성을 위한 아세틱안하이드리드의 연소특성치 측정 (The Measurement of Combustible Properties of Acetic Anhydride for the Compatibility of MSDS)

  • 하동명
    • 한국안전학회지
    • /
    • 제29권4호
    • /
    • pp.85-90
    • /
    • 2014
  • For the safe handling of acetic anhydride, this study was investigated the explosion limits of acetic anhydride in the reference data. And the lower flash points, upper flash points, and AITs(auto-ignition temperatures) by ignition delay time were experimented. The lower and upper explosion limits of acetic anhydride by the investigation of the literatures recommended 2.9 Vol% and 10.3 Vol.%, respectively. The lower flash point of acetic anhydride by using Setaflash closed-cup tester was experimented $49^{\circ}C$. The lower flash point acetic anhydride by using Tag and Cleveland open cup tester were experimented $55^{\circ}C$and $62^{\circ}C$, respectively. Also, this study measured relationship between the AITs and the ignition delay times by using ASTM E659 tester for acetic anhydride. The experimental AIT of acetic anhydride was $350^{\circ}C$.

The Flash Points of the Butylacetate+2-Propanol System Measured By Air Blowing Tester

  • Ha, Dong Myeong;Lee, Sung Jin;Mok, Yun Soo;Choi, Jae Wook
    • International Journal of Safety
    • /
    • 제2권1호
    • /
    • pp.34-38
    • /
    • 2003
  • The lower and upper flash points of the flammable binary system, butylacetate+2-propanol were measured by air blowing tester. The shape of the concentration-temperature region of flash depended on the components of the mixture in solution. The experimental data were compared with the values calculated by the reduced model under an ideal solution assumption and the flash point-prediction models based on Van Laar equation. Good qualitative agreement was obtained with these models. The prediction results of these models can thus be applied to incorporate inherently safer design for chemical process, such as the determination of the safe storage conditions for flammable solutions.

사이클로헥산올의 연소특성치의 측정 (The Measurement of Combustible Properties of Cyclohexanol)

  • 하동명
    • 한국화재소방학회논문지
    • /
    • 제28권2호
    • /
    • pp.64-68
    • /
    • 2014
  • 사이클로헥산올의 안전한 취급을 위해, 폭발한계는 문헌을 통해 고찰하였고, 인화점과 발화지연시간에 의한 발화온도를 측정하였다. 그 결과, 밀폐식 장치에 의한 사이클로헥산올의 하부인화점은$60^{\circ}C{\sim}64^{\circ}C$로 측정되었으며, 개방식에서는 $66^{\circ}C{\sim}68^{\circ}C$로 측정되었다. ASTM E659 장치를 사용하여 자연발화온도와 발화지연시간을 측정하였고, 사이클로헥산올의 최소자연발화온도는 $297^{\circ}C$로 측정되었다. 측정된 하부인화점과 상부인화점에 의한 폭발하한계는 0.95 Vol%, 상한계는 10.7 Vol%로 계산되었다.