• 제목/요약/키워드: low-temperature recovery

검색결과 360건 처리시간 0.024초

물유동층 열교환기의 열회수성능 연구 (A Study on the Heat Recovery Performance of Water Fludized-Bed Heat Exchanger)

  • 김한덕;박상일;이세균
    • 설비공학논문집
    • /
    • 제15권8호
    • /
    • pp.690-696
    • /
    • 2003
  • This paper presents the heat recovery performance of water fluidized-bed heat exchanger. Temperature and humidity ratio of waste gas are considered as important parameters in this study. Therefore, the heat recovery rate through water fluidized-bed heat exchanger for exhaust gases with various temperatures and humidity ratios can be estimated from the results of this study. Mass flow ratio (the ratio of mass flow rate of water to that of gas) and temperature of inlet water are also considered as important operating variables. Increase of heat recovery rate can be obtained through either high mass flow ratio or low temperature of inlet water with resultant low recovered temperature. The heat recovery performance with the mass flow ratio of about up to 10 has been investigated. The effect of number of stages of water fluidized-bed on the heat recovery performance has been also examined in this study.

비글견에서 Propofol 완전정맥마취와 Isoflurane 휘발성 유도/유지 마취 시 심폐기능과 회복의 비교 (Comparison of Cardiopulmonary Effects and Recovery between Total Intravenous Anesthesia with Propofol and Volatile Induction/maintenance Anesthesia with Isoflurane in Beagle Dogs)

  • 이수한
    • 한국임상수의학회지
    • /
    • 제22권3호
    • /
    • pp.259-263
    • /
    • 2005
  • To compare cardiopulmonary effects and recovery between total intravenous anesthesia (TIVA) with propofol (PRO group, n=5) and volatile induction/maintenance anesthesia (VIMA) with isoflurane (ISO group, n=5), we investigated changes of heart rate, $SpO_2$, arterial pressure, rectal temperature and respiratory rate during 60 minute anesthesia and 40 minute recovery period in beagle dogs, and investigated recovery (extubation, head lift, sternal position and righting) after 60 minute anesthesia. Rectal temperature was significantly low in ISO group (p<0.05) from 10 to 100 minute. Heart rate was significantly low in ISO group (p<0.05) at 40, 50, 60 minute. Respiratory rate was significantly low in PRO group (p<0.05) at induction and 70 minute. $SpO_2$ tendency was similar. Systolic arterial pressure (SAP) was significantly low in ISO group (p<0.05) at induction and during anesthesia. Recovery was similar in two groups. We concluded that TIVA with propofol is useful in stabilizing rectal temperature and arterial pressure during anesthesia and provide fast and stable recovery.

Effects of Process Variables on The Electrochemical Recovery of Palladium in A HCl Solution

  • Kim, Min-Seuk;Lee, Jae-Chun;Kim, Won-Baek
    • 자원리싸이클링
    • /
    • 제14권1호
    • /
    • pp.55-63
    • /
    • 2005
  • This study investigated the electrochemical recovery of palladium in a HCl solution that is used for palladium leaching. The high acidity of HCl solution and the low concentration of Pd ions increased the cathodic overpotential and reduced the limiting current density. Lowering the current density produced dense deposits; however, they were under high tensile stress. Raising the temperature affected both the densification and the stress, which enabled the attainment of dense Pd deposits under low stress. Lowering the current density and raising the temperature up to 70$^{\circ}C$ was recommended for the recovery of palladium as sound bulk Pd deposits. Current efficiency was over 85% at the initial stage of recovery may decrease the current efficiency, since a low Pd ion concentration results in a low limiting current density.

Study on Performance Evaluation of Oscillating Heat Pipe Heat Exchanger for Low Temperature Waste Heat Recovery

  • Bui, Ngoc-Hung;Kim, Ju-Won;Jang, In-Seung;Kang, Jeong-Kil;Kim, Jong-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권2호
    • /
    • pp.73-81
    • /
    • 2003
  • The performance of heat exchanger using oscillating heat pipe (OHP) for low temperature waste heat recovery was evaluated. OHP used in this study was made from low finned copper tubes connected by many turns to become the closed loop of serpentine structure. The OHP heat exchanger was formed into shell and tube type. R-22 and R-141b were used as the working fluids of OHP with a fill ratio of 40 vol.%. Water was used as the working fluid of shell side. As the experimental parameters, the inlet temperature difference between heating and cooling water and the mass velocity of water were changed. The mass velocity of water was changed from 30 kg/$m^2$s to 92 kg/$m^2$s. The experimental results showed that the heat recovery rate linearly increased as the mass velocity and the inlet temperature difference of water increased. Finally, the performance of OHP heat exchanger was evaluated by $\varepsilon$-NTU method. It was found that the effectiveness would be 80% if NTU were about 1.5.

Influence of Working Fluids to Heat Transfer Characteristics of Heat Exchanger using Oscillating Capillary Tube Heat Pipe for Low Temperature Waste Heat Recovery

  • Lee, Wook-Hyun;Im, Yong-Bin;Kim, Ju-Won;Kim, Jeung-Hoon;Kim, Jong-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권3호
    • /
    • pp.27-35
    • /
    • 2001
  • Heat transfer characteristics of a heat exchanged for low temperature waste heat recovery using oscillating capillary tube heat pipe (OCHP) were evaluated against the charging ratio variation of working fluid and various working fluids. R-l42b, R-22 and R-290 were used as working a 2.6mm in outside diameter, 1.44mm in inside diameter with 101m length and 140 turns. Charging ratio of working fluid was 40% and 50%. water was used as secondary fluid. Inlet temperature and mass velocity for each secondary fluid were 297 K, 280 K and 9~27 $4kg/m^2s$, respectively. From experimental results, it was found that heat transfer performance of R-22 was higher than those of R-142b and R-290 and it was proportional to Figure of Merit for thermosyphon. As a result, it was thought that R-22 was the most reasonable working fluid of waste heat recovery for low temperature waste heat recovery.

  • PDF

저온 폐열회수용 진동세관형 히트파이프 열교환기의 작동 유체에 따른 열전달 특성 (Influence of Working Fluids to Heat Transfer Characteristics of the Heat Exchanger using Oscillating Capillary Tube Heat Pipe for Low Temperature Waste Heat Recovery)

  • 이욱현;임용빈;김정훈;김종수
    • 설비공학논문집
    • /
    • 제12권7호
    • /
    • pp.659-666
    • /
    • 2000
  • Heat transfer characteristics of a heat exchanger for low temperature waste heat recovery using oscillating capillary tube heat pipe were evaluated against the charge ratio variation of working fluid and various working fluids. R-l42b, R-22 and R-290 were used as working fluids. The heat exchanger was composed of heat pipe with capillary tube bundles, having a 2.6mm in outer diameter, 1.4mm in inner diameter with 101m long, and 40 turns. Charge ratio of working fluid was 40% and 50%. Water was used as secondary fluid. Inlet temperature and mass velocity for each secondary fluid were 297 K, 280 K and9~27 kg /$m^2s$,, respectively. From experimental results, it was found that heat transfer performance of R-22 was higher than those of R-l42b and R-290 and it was proportional to Figure of merit for thermosyphons. As a result, it was thought that R-22 was the most suitable working fluid of waste heat recovery for low temperature waste heat recovery.

  • PDF

저온 폐열 회수용 진동형 히트 파이프 열교환기의 성능 평가에 관한 연구 (Study on Performance Evaluation of Oscillating Heat Pipe Heat Exchanger for Low Temperature Waste Heat Recovery)

  • 안영태;이욱현;김정훈;김종수
    • 설비공학논문집
    • /
    • 제13권5호
    • /
    • pp.368-376
    • /
    • 2001
  • Performance of heat exchanger was evaluated to heat exchanger using oscillating heat pipe for waste heat recovery of low temperature. Oscillating heat pipe used in this study was formed to the closed loop of serpentine shapes using copper tubes. Heat exchanger was formed to shell and tube type and composed of low finned tube. R-22 and R-141b were used to the working fluids of tube side and their charging ratio was 40%. And, water was used to the working fluid of shell side. As the experimental parameters, the inlet temperature difference of heating and cooling part of secondary fluid and the mass velocity of secondary fluid were used. The mass velocity of secondary fluid was changed from 90 kg/$m^2s\; to\;190 kg/m^2$s from the experimental results, heat recovery rate was linearly increased to the increment of the mass velocity of secondary fluid and the inlet temperature difference of secondary fluid. Finally, the performance of heat exchanger was evaluated by using $\varepsilon$-NTU method. It was found that NTU was about 1.5 when effectiveness was decided to 80%.

  • PDF

폐전선으로부터 유가자원 회수를 위한 저온열분해(II) (Low Temperature Pyrolysis for the Recovery of Value-added Resources from Waste Wire (II))

  • 한성국;김재용
    • 공업화학
    • /
    • 제20권5호
    • /
    • pp.553-556
    • /
    • 2009
  • 본 연구의 목표는 열분해 기술의 문제점을 보완하여 유가자원의 회수와 폐기물 처리의 효율을 높이는데 있다. 우선 경제성을 높이기 위해 기존 열분해온도(보통 $500{\sim}1000^{\circ}C$)보다 낮은 $450^{\circ}C$에서의 저온열분해 반응을 시도하였다. 촉매를 사용하여 반응온도와 반응시간을 단축할 수 있었고, 무 산소 상태를 유지시키는데 유리하도록 간접열을 사용하였다. 결과적으로 유가자원인 구리와 합성연료유의 회수율을 증가시킬 수 있었고, 발생하는 부산물과 배가스의 처리효과가 뛰어남을 알 수 있었다. 배가스는 2단의 중화조를 통과시켜 다이옥신은 거의 발생되지 않았으며, 나머지 대기환경기준의 측정항목 또한 기준치 이하를 보였다. 이번 연구에서는 앞에서 말한 저온 열분해장치(GTPK-001)를 제작하였고, 경제적으로나 친환경적으로 상용화 개발이 가능함을 알 수 있었다.

저온 디젤 연소에서 T90 온도가 배기가스에 미치는 영향 (The Effect of T90 Temperature on Exhaust Emissions in Low-temperature Diesel Combustion)

  • 한만배
    • 한국자동차공학회논문집
    • /
    • 제19권4호
    • /
    • pp.72-77
    • /
    • 2011
  • This study is to investigate the effect of the distillation temperature in ultra low sulfur diesel fuel on exhaust emissions in the low-temperature diesel combustion with 1.9L common rail direct injection diesel engine. Low temperature diesel combustion was achieved by adopting an external high EGR rate with a strategic injection control. The engine was operated at 1500 rpm 2.6 bar BMEP. The 90% distillation recovery temperature (T90) was $270^{\circ}C$ and $340^{\circ}C$ for the respective cetane number (CN) 30 and 55. It was found that there exists no distinctive discrepancy on exhaust emissions with regards to the different T90s. The high CN (CN55) fuels follow the similar trend of exhaust emissions as observed in CN30 fuels' except that high T90 fuel (CN55-T340) produced higher PM compared to low T90 fuel (CN55-T270). This may come from that high T90 plays an active role in aggravating the degree of fuel-air mixture preparedness before ignition.

Growth Responses and Regrowth to Low Temperature of Nine Native Moss Species

  • Gong, Gyeong Yeop;Jeong, Kyeong Jin;Lee, Sang Woo;Yun, Jae Gill
    • 인간식물환경학회지
    • /
    • 제22권6호
    • /
    • pp.575-582
    • /
    • 2019
  • Moss is used as an important material in indoor landscaping as well as outdoor landscaping. Moss is vivid green during growth and excellent in ornamental value. But when temperature drops, moss stops growth, turns brown or loses its ornamental value. In the present experiment, for the purpose of classifying native mosses according to the growth response to low temperature, the temperature of the plant growth chamber was set to 15℃/5℃ (16h/8h, day/night) and 5℃ (24h) for 8 weeks using nine native moss species. Thereafter, the temperature of the plant growth chamber was set to 20℃, and then the changes of moss block area and moss color were measured. The changes of moss block area and moss color were measured using a Photoshop program, after each moss block was photographed. As a result, Atrichum undulatum (Hedw.). Beauv., Etodon luridus (Griff.) A. Jaeger, Bachythecium plumosum (Hedw.) Schimp, Plagiomnium cuspidatum (Hedw.) T.J. Kop, and Hypnum plumaeforme Wilson showed a small decrease in moss block area at low temperature, and their recovery were the fastest at 20℃. These three species had higher green values at low temperature compared to other species, and the greenness increased rapidly at 20℃. On the other hand, Atrichum undulatum (Hedw.). Beauv., Marchantia polymorpha L., and Thuidium cymbifolium (Mitt.) A. Jaeger showed the smallest block area at low temperature and the lowest recovery even at 20℃. Their green values also decreased significantly at low temperature, and maintained low green value even at 20℃. These results showed that these three moss species are sensitive to low temperature. The remaining Myuroclada maximowiczii, Plagiomnium cuspidatum, and H. erectiusculum showed moderate responses to low temperature compared to other six species of mosses.