• Title/Summary/Keyword: low-slump concrete

Search Result 93, Processing Time 0.025 seconds

Quality Improvement of Concrete Depending on the Mixing of Fine Aggregates Different Compositions and Grain Sizes (성분 및 입도분포가 다른 잔골재의 혼합에 의한 콘크리트의 품질향상)

  • Kim, Young-Hee;Park, Min-Yong;Kim, Jung-Bin;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.77-79
    • /
    • 2012
  • This study is to assess the differences between concrete having only one of fine aggregates such as crushed fine aggregates, sea sand and blast furnace slag in it and concrete having mixture of two kinds of those fine aggregates in it in order to find out how to deal with the lack of some aggregates. The findings are as follows. In terms of slump, the concrete containing sea sand and blast furnace slag has very low slump values while the concrete having the mixture of crushed fine aggregate and the other fine aggregates showed better workability. In terms of compressive strength, the concrete containing the mixture of two kinds of aggregates showed higher compressive strength. Accordingly, it is likely that the concrete containing the mixture of crushed fine aggregate, sea sand and blast furnace slag is better than the concrete with only one kind of fine aggregates in terms of the usability.

  • PDF

A Fundamental Study on the Consistency of Base Concrete Influencing on the Worability and Engineering Properties of Folwing Concrete (유동화콘크리트의 시공성 및 공학적 특성에 미치는 베이스콘크리트의 시공연도에 관한 기초적 연구)

  • 김무한;송하영
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.04a
    • /
    • pp.1-6
    • /
    • 1992
  • The objective of this report is to investigate and analyze the influnce of the different base concrete in consistency for the good production of superplasticized concrete (SPC) on the basis of the experimental results. The principal conclusions are summarized as follows. 1. SPC exhibited only slight bleeding in both cases of low and medium consistency of the base concrete, compared to the conventional concrete, compared to the coventional concrete. 2. SPC lost slump and flow value at a much faster rate than the conventional concrete with an equivalent water/cement ratio and initial consistency. 3. The compressive strength of SPC was fount to be higher than that of base and conventional concrete, and the case of base concrete with medium consistency showed a little more incretment than low consistency

  • PDF

An Experimental Study on the Characteristic of Porous Concrete using different Aggregates (골재의 종류에 따른 포러스콘크리트의 특성에 관한 실험적 연구)

  • Jung, Si-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.1
    • /
    • pp.89-96
    • /
    • 2004
  • Porous concrete is used of various parts by advantage of porous. Example of growing of plant is possible, and dwelling of creature, and filter functions of various contaminant, and decrease of noise, and so on. This research is for porous concretes that were used by four aggregate rubble, refreshing aggregate, expanded clay, orchid stone. This research estimate that physical and mechanical characteristics of fresh concrete and hardened concrete. The purpose of this research is to make environment-friendly porous concrete. This research's conclusion is as following : 1. Porous Concrete's slump was measured 12~14cm with rubble, 12~16cm with refreshing aggregate, 11~13cm with expanded clay, 11~13cm with orchid stone. Weight of aggregate was bigger, slump price appeared by bigger thing. Because placed Porous Concrete is low viscosity and small resistance between aggregate, it estimated that have high workability. 2. Porous Concrete's unit weight was measured 1.71~1.75t/$\textrm{m}^3$ with rubble, 1.58~1.62t/$\textrm{m}^3$ with refreshing aggregate, 1.19~1.20t/$\textrm{m}^3$ with expanded clay, 0.98~1.06t/$\textrm{m}^3$ with orchid stone. Showed aspect such as weight of aggregate. 3. Porous Concrete's compressive strength was measured 76~102kgf/$\textrm{cm}^2$ with rubble, 51~60kgf/$\textrm{cm}^2$ with refreshing aggregate, 30~40kgf/$\textrm{cm}^2$ with expanded clay, 13~16kgf/$\textrm{cm}^2$ with orchid stone. 4. Tendency of tensile strength and bending strength showed generally similarly with compressive strength, but showed low value fewer than 15kgf/$\textrm{cm}^2$ Therefore, wire mesh, reinforcing rod, such as establishment of frame is considered to need in reinforcement about tensility or flexures in case receive tensility or produce product of thin absence form. It concludes by speculating on the consequences of extrapolating the results of study to remodelling the office building being already existence.

The Study on the Physical and Strength Properties of Lightweight Concrete by Replacement Ratio of Artificial Lightweight Aggregate (인공경량골재 혼합비율에 따른 경량 콘크리트의 물성 및 강도특성에 관한 연구)

  • Choi, Se-Jin;Kim, Do-Bin;Lee, Kyung-Su;Kim, Young-Uk
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.4
    • /
    • pp.313-322
    • /
    • 2019
  • This study is to compare and analyze the physical and strength properties of lightweight concrete using domestic lightweight aggregate by replacement ratio of artificial lightweight fine and coarse aggregate after considering low cement mixture and pre-wetting time. The slump, unit weight, compressive strength and split tensile strength of lightweight concrete with domestic lightweight aggregate were measured. As test results, the slump of lightweight concrete by replacement ratio of lightweight fine aggregate increased as the replacement ratio of lightweight fine aggregate increased. The unit weight of lightweight concrete using 100% of lightweight fine aggregate was about 10.4% lower than that of the lightweight concrete with natural sand. In addition, the unit weight of lightweight concrete by replacement ratio of lightweight coarse aggregate increased with the increase of the ratio of LWG10(5~10mm). The compressive strength of lightweight concrete with lightweight fine and coarse aggregate increased as the replacement ratio of lightweight fine aggregate increased. The compressive strength of lightweight concrete with natural sand and LWG10 was 30 to 31MPa regardless of the replacement ratio of the lightweight coarse aggregate after 7 days.

An Application of the Mass Concrete Using Ternary Blended Cement (3성분계 시멘트를 사용한 매스콘크리트의 시공사례)

  • 권영호;하재담;전성근;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.1229-1234
    • /
    • 2001
  • The bottom slab of Inchon LNG in-ground #213 tank is designed as a massive structure witch has a large depth and section. The purpose of this study is to determine the optimum mix design having good workability and low hydration heat for bottom slab concrete and to control the actual concrete quality in site. For this purpose, we select the optimum mix design used ternary blended cement(furnace slag cement+fly ash) and design factors. As test results of actual application, we have finish placing the bottom slab concrete of 23,180㎥ during 68hours with good success and obtain the good quality of fresh and hardened concrete including slump, air contents, no-segregation, compressive strength and low hydration heat in actual data. All test results are satisfied with our specifications for bottom slab concrete and we cut costs as the use of ternary blended cement and the reduction of placing hours.

  • PDF

Chemical Resistance of Low Heat Cement Concrete Used in Wastewater Treatment Structures Built on Reclaimed Land (해안매립지 하수처리시설물에 적용한 저발열시멘트 콘크리트의 내화학성 평가)

  • Chung, Yongtaek;Lee, Byungjae;Kim, Yunyong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.113-119
    • /
    • 2019
  • Concrete structures built on reclaimed land are combined with chemical erosion such as chlorine and sulfate ions from seawater. Chloride attack deteriorates the performance of the structure by corroding reinforcing bars. In addition, the waste water treatment structure has a problem that the concrete is deteriorated by the sulfate generated inside. Therefore, in this study, the characteristics and chemical resistance of low heat cement concrete used in wastewater treatment structures constructed on reclaimed land were evaluated. As a result of the experiment, the target slump and air content were satisfied under all the mixing conditions. The slump of low heat cement (LHC) concrete was higher than that of ordinary portland cement (OPC) concrete, while the air content of LHC concrete was smaller than that of OPC concrete with the same mix proportion. As a result of compressive strength test, OPC concrete showed higher strength at younger age compared to 28 days. In contrast, LHC concrete exhibited higher strength than OPC concrete at the age of 56 days. As a result of chlorine ion penetration tests, LHC-B concrete showed chlorine ion penetration resistance performance of the "very low" level at the age of 56 days. As a result of chemical resistance evaluation, when the LHC concrete is applied without epoxy treatment, chemical resistance is improved by about 18% compared to OPC concrete. In testing chemical resistance, the epoxy coated concrete exhibited less than 5% strength reduction when compared to sound concrete.

Performance characteristics of dredged silt and high-performance lightweight aggregate concrete

  • Wang, H.Y.;Sheen, Y.N.;Hung, M.F.
    • Computers and Concrete
    • /
    • v.7 no.1
    • /
    • pp.53-62
    • /
    • 2010
  • Dredged silt from reservoirs in southern Taiwan was sintered to make lightweight aggregates (LWA), which were then used to produce high-performance lightweight aggregate concrete (HPLWC). The HPLWC was manufactured using different amounts of mixing water (140, 150, and 160 $kg/m^3$) and LWA of different particle densities (700, 1100, and 1500 $kg/m^3$) at different W/b ratios (0.28, 0.32, and 0.4). Results show that the lightweight aggregates of dredged silt taken in southern Taiwan perform better than the general lightweight aggregates. In addition, the HPLWC possessed high workability with a slump of 230-270 mm, and a slump flow of 450-610 mm, high compressive strength of over 40 MPa after 28 days of curing, good strength efficiency of cement exceeding $0.1MPa/kg/m^3$, low thermal conductivity of 0.4-0.8 $kcal/mh^{\circ}C$, shrinkage of less than $4.8{\times}10^{-4}$, and high electrical resistivity of above 40 $k{\Omega}-cm$. The above findings prove that HPLWC made from dredged silt can help enhance durability of concrete and provide and an ecological alternative use of dredged silt.

An Economic Mix Design Methodology for the Development of Concrete Strength at Low Temperature (저온에서의 콘크리트 강도 확보를 위한 경제적 배합 방안)

  • Kim, Sang-Chel;Kim, Yong-Jic;Kim, Young-Jin
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.4
    • /
    • pp.95-103
    • /
    • 2012
  • Precast concrete method is known to have advantages of minimizing works in the construction, controlling concrete quality easily and saving construction period due to only fabrication work in the construction field, but it needs to apply steam curing to accelerate early concrete strength. In the meanwhile, the oil cost for steam curing has been continuously increased because of political instability in the middle East and international economic shaky. Thus, this study addresses the development of precast/ prestressed concrete which has over 14MPa at 1 day age and specified concrete strength of 40MPa at low temperature, not applying steam curing. Tests were carried out in terms of material characteristics in fresh concrete and compressive strength using 3 types of cement such as Type I, Type III and rapid hardening compound cement. As results of tests, it is found that cements for rapid hardening had disadvantages with respect to slump, slump loss, and air content, but showed higher compressive strength than specified one, especially the highest value when using rapid hardening compound.

  • PDF

Evaluation of Crack Control Performance of the Concrete with Fiber Combination (섬유혼입 조건에 따른 콘크리트의 균열제어 성능 평가)

  • Park, Jae-Yong;Lee, Myoung-Ho;Kang, Byung-Hoi;Kim, Kyoung-Hoon;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.21-22
    • /
    • 2013
  • Nowadays, the fiber which mixed with concrete matrix always has low adhesion with cement paste. It's difficult to use fiber to reinforce the structure. For more adding fiber in concrete would cause some problems as the low flowability and surface polishing. Further study is needed in fiber using. In this research, further study in fiber reinforced concrete has been invested. Various fibers with different properties have been used to prevent cracking. Fiber reinforced concrete's fundamental properties as slump, air content, compressive strength and tensile strength have been tested. Optimum type of the fiber and optimum addition ratio of fiber has been invested to increase the utility of the fiber which used in concrete.

  • PDF

Influence on the Plastic Shrinkage of Concrete for a Varieties of Consistency (콘크리트의 Consistency 변화가 소성수축에 미치는 영향)

  • 오무영
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.20 no.1
    • /
    • pp.4626-4630
    • /
    • 1978
  • The objective of this study is to investigate how the varieties of consistency of fresh concrete influence on the plastic shrinkage in dry condition. The test was conducted under the controlled chamber in which the temperature was kept at 25 ${\pm}$2$^{\circ}C$, the humidity 35 ${\pm}$3%, and the wind velocity 4.0 ${\pm}$0.5m/sec. The results obtained from the test are as follow. 1) The rate of evaporation was highest at 2-3 hour after casting, and decreased gradually. 2) The plastic shrinkage was increased as to the slump values. The shrinkage rate was very highest at 2-4 hour and hardly showed any changes after 6 hour. 3) The recommendation for good cloncrete is that slump value should be as low as possible in construction.

  • PDF