• 제목/요약/키워드: low-rise structures

검색결과 342건 처리시간 0.025초

The effect of three-variable viscoelastic foundation on the wave propagation in functionally graded sandwich plates via a simple quasi-3D HSDT

  • Tahir, Saeed I.;Tounsi, Abdelouahed;Chikh, Abdelbaki;Al-Osta, Mohammed A.;Al-Dulaijan, Salah U.;Al-Zahrani, Mesfer M.
    • Steel and Composite Structures
    • /
    • 제42권4호
    • /
    • pp.501-511
    • /
    • 2022
  • Earthquake Resistant Design Philosophy seeks (a) no damage, (b) no significant structural damage, and (c) significant structural damage but no collapse of normal buildings, under minor, moderate and severe levels of earthquake shaking, respectively. A procedure is proposed for seismic design of low-rise reinforced concrete special moment frame buildings, which is consistent with this philosophy; buildings are designed to be ductile through appropriate sizing and reinforcement detailing, such that they resist severe level of earthquake shaking without collapse. Nonlinear analyses of study buildings are used to determine quantitatively (a) ranges of design parameters required to assure the required deformability in normal buildings to resist the severe level of earthquake shaking, (b) four specific limit states that represent the start of different structural damage states, and (c) levels of minor and moderate earthquake shakings stated in the philosophy along with an extreme level of earthquake shaking associated with the structural damage state of no collapse. The four limits of structural damage states and the three levels of earthquake shaking identified are shown to be consistent with the performance-based design guidelines available in literature. Finally, nonlinear analyses results are used to confirm the efficacy of the proposed procedure.

Shear strength prediction of concrete-encased steel beams based on compatible truss-arch model

  • Xue, Yicong;Shang, Chongxin;Yang, Yong;Yu, Yunlong;Wang, Zhanjie
    • Steel and Composite Structures
    • /
    • 제43권6호
    • /
    • pp.785-796
    • /
    • 2022
  • Concrete-encased steel (CES) beam, in which structural steel is encased in a reinforced concrete (RC) section, is widely applied in high-rise buildings as transfer beams due to its high load-carrying capacity, great stiffness, and good durability. However, these CES beams are prone to shear failure because of the low shear span-to-depth ratio and the heavy load. Due to the high load-carrying capacity and the brittle failure process of the shear failure, the accurate strength prediction of CES beams significantly influences the assessment of structural safety. In current design codes, design formulas for predicting the shear strength of CES beams are based on the so-called "superposition method". This method indicates that the shear strength of CES beams can be obtained by superposing the shear strengths of the RC part and the steel shape. Nevertheless, in some cases, this method yields errors on the unsafe side because the shear strengths of these two parts cannot be achieved simultaneously. This paper clarifies the conditions at which the superposition method does not hold true, and the shear strength of CES beams is investigated using a compatible truss-arch model. Considering the deformation compatibility between the steel shape and the RC part, the method to obtain the shear strength of CES beams is proposed. Finally, the proposed model is compared with other calculation methods from codes AISC 360 (USA, North America), Eurocode 4 (Europe), YB 9082 (China, Asia), JGJ 138 (China, Asia), and AS/NZS 2327 (Australia/New Zealand, Oceania) using the available test data consisting of 45 CES beams. The results indicate that the proposed model can predict the shear strength of CES beams with sufficient accuracy and safety. Without considering the deformation compatibility, the calculation methods from the codes AISC 360, Eurocode 4, YB 9082, JGJ 138, and AS/NZS 2327 lead to excessively conservative or unsafe predictions.

하계 해수면 상승이 폭풍해일고 분석에 미치는 영향 (Effect of Summer Sea Level Rise on Storm Surge Analysis)

  • 김아정;이명희;서승원
    • 한국해안·해양공학회논문집
    • /
    • 제33권6호
    • /
    • pp.298-307
    • /
    • 2021
  • 태풍은 7~10월에 집중적으로 발생하며, 이 시기에 해수면도 가장 높게 나타난다. 특히 우리나라 하계 해수면은 연평균과 비교했을 때 서해안 약 14.5 cm, 남해안 약 9.0~14.5 cm, 동해안 약 9.0 cm 내외로 더 높게 나타난다. 하계에 상승하는 해수면과 대형 태풍이 겹치면 연안 저지대에 침수, 범람 등의 피해를 야기할 수 있다. 따라서 연안저지대의 피해를 저감하기 위해 해안 구조물 설계 및 안정성 검토 시 정확한 해일고 산정이 필수적이다. 본 연구에서는 태풍이 영향을 미친 하계 해수면 상승이 고려된 해당 월의 평균 해수면으로부터 산정된 해일고(SH_m)를 산정하고 이를 연평균 해수면이 고려된 기존 해일고(SH_a)와 비교하여 특이현상 분석의 타당성을 재검토하였다. 연구 결과, 연평균 해수면 대비 해수면 상승 폭이 가장 큰 8~9월에 발생한 BOLAVEN(SANBA)의 직접 영향을 받은 남서(남동)해안에서 SH_a, SH_m의 해일고(cm) 차이는 7.8~24.5(23.6~34.5), 간접 영향권에 속한 남동(남서)해안에서 -1.0~0.0(8.3~12.2)로 나타난다. 그러나, 연평균 및 월평균 해수면이 비슷한 높이를 가지는 10월에 남동해안에 직접적 영향을 미친 CHABA(KONG-REY)의 경우 5.2~14.2(19.8~21.6), 간접 영향을 미친 서해안에서 3.2~6.3(-3.2~3.7)으로 직·간접 영향권 모두 SH_a와 SH_m의 차이가 작아진다. 연평균 해수면을 기준으로 산정한 기존 해일고는 상승된 하계 해수면이 고려되지 못하여, 실제 태풍 시 발생하는 해일고에 비해 과대 산정된 것으로 평가된다. 따라서 정확한 해일고 개념 정립과 함께 기존의 연평균 해수면을 고려한 해일고 기준으로 설계된 연안 시설물 마루높이 등의 타당성 검토가 재논의되어야 할 것으로 판단된다.

비탄성 정적해석을 이용한 격자강판 전단벽 보강 RC구조물의 내진성능평가 (Seismic Performance Evaluation of RC Structure Strengthened by Steel Grid Shear Wall using Nonlinear Static Analysis)

  • 박정우;이재욱;박진영;이영학;김희철
    • 한국전산구조공학회논문집
    • /
    • 제26권6호
    • /
    • pp.455-462
    • /
    • 2013
  • 최근에 지어진 건축물의 경우 지진에 대한 안전성을 확보하고 있지만, 내진설계 도입 이전의 건축물은 지진에 대해 매우 취약하다. 본 연구에서는 내진성능이 부족한 기존 저층 RC구조물의 지진 발생 시 안전성 확보를 위한 내진보강 방안으로 격자강판 전단벽을 제안하고 내진성능평가를 수행하였다. 횡력저항요소로 사용된 격자강판 전단벽의 탄소성 이력특성값은 실험결과를 토대로 횡력저항 기여도등을 평가하여 작성된 이선형곡선을 적용하였다. 비탄성 정적해석을 통해 대상구조물의 성능점을 찾아내어 적용 지진하중에 대한 응답과 성능수준을 평가하였다. 격자강판 전단벽을 적용한 경우, 보강 전에 비하여 응답변위가 약 42% 저감되는 것을 확인할 수 있었으며, 성능점에서 거의 탄성거동을 보여주고 있어 목표성능인 인명안전수준을 만족시켰다. 또한 반응수정계수를 산정하여 내진보강 효과를 검증하였으며, 보강 전과 후에 각각 2.17에서 3.25로 증가하여 설계기준을 초과하였다. 따라서 격자강판 전단벽에 의해 대상 구조물의 강도 및 강성보강이 적절히 수행된 것으로 판단된다.

발전용 역청탄과 저열량탄 혼소시 Tar/Soot의 배출 특성 연구 (Investigation of Tar/soot Yield of Bituminous and Low Rank Coal Blends)

  • 이병화;김진호;김규보;김승모;전충환
    • 에너지공학
    • /
    • 제23권2호
    • /
    • pp.42-48
    • /
    • 2014
  • 미분탄의 연소 또는 열분해 과정으로부터 발생하는 tar-soot는 복사 열전달 및 질소산화물의 추가적인 발생 원인이라는 관점에서 의미 있게 다루어지고 있다. 최근 저열량탄이 증가함에 따라 시멘트의 원료로 재활용되던 석탄회에서 다량의 미연분과 tar-soot가 포함되어 오히려 다시 반입되는 사례가 빈번해지고 있다. 따라서 본 연구에서는 저열량탄 사용 확대에 따른 혼탄연소 조건에서 tar-soot의 배출특성을 살펴보기 위해 반응기로써 LFR(Laminar Flow Reactor)을 적용하였으며, 연료로는 현재 국내발전소에서 사용 중인 역청탄 2종(MOUNTAIN, MACARHTUR)과 아역청탄(KPU)을 이용하여 단탄별 tar-soot 배출특성과 혼소비에 따른 배출특성을 화염의 구조 변화와 함께 측정하였다. 휘발분이 많은 아역청탄의 soot cloud 길이는 역청탄에 비해 길었지만 전체적인 화염 길이는 짧아졌다. 단탄별 실험결과에서는 역청탄의 tar-soot 발생량이 아역청탄의 발생률보다 높았으며 역청탄 중 휘발분 함량이 많은 MOUNTAIN탄이 상대적으로 휘발분 함량이 적은 MACARHTUR탄의 tar-soot 발생률보다 높았다. 혼소시에는 단탄의 연소특성과는 다른 새로운 특성을 나타내었으며 저열량탄과 혼소되는 역 청탄의 종에 따라 tar-soot 발생량이 지배되는 것을 확인하였으나 혼소비에 따른 평균적 특성이 아닌 완전히 차별되는 배출특성을 나타냄에 따라 석탄의 등급에 따라 최적의 혼소비를 찾아서 연소시키는 것이 tar-soot 발생량을 줄일 수 있는 방법임을 의미한다.

에폭시 수지 모르터의 특성에 관한 실험적 연구 (Experimental Studies on the Properties of Epoxy Resin Mortars)

  • 연규석;강신업
    • 한국농공학회지
    • /
    • 제26권1호
    • /
    • pp.52-72
    • /
    • 1984
  • This study was performed to obtain the basic data which can be applied to the use of epoxy resin mortars. The data was based on the properties of epoxy resin mortars depending upon various mixing ratios to compare those of cement mortar. The resin which was used at this experiment was Epi-Bis type epoxy resin which is extensively being used as concrete structures. In the case of epoxy resin mortar, mixing ratios of resin to fine aggregate were 1: 2, 1: 4, 1: 6, 1: 8, 1:10, 1 :12 and 1:14, but the ratio of cement to fine aggregate in cement mortar was 1 : 2.5. The results obtained are summarized as follows; 1.When the mixing ratio was 1: 6, the highest density was 2.01 g/cm$^3$, being lower than 2.13 g/cm$^3$ of that of cement mortar. 2.According to the water absorption and water permeability test, the watertightness was shown very high at the mixing ratios of 1: 2, 1: 4 and 1: 6. But then the mixing ratio was less than 1 : 6, the watertightness considerably decreased. By this result, it was regarded that optimum mixing ratio of epoxy resin mortar for watertight structures should be richer mixing ratio than 1: 6. 3.The hardening shrinkage was large as the mixing ratio became leaner, but the values were remarkably small as compared with cement mortar. And the influence of dryness and moisture was exerted little at richer mixing ratio than 1: 6, but its effect was obvious at the lean mixing ratio, 1: 8, 1:10,1:12 and 1:14. It was confirmed that the optimum mixing ratio for concrete structures which would be influenced by the repeated dryness and moisture should be rich mixing ratio higher than 1: 6. 4.The compressive, bending and splitting tensile strenghs were observed very high, even the value at the mixing ratio of 1:14 was higher than that of cement mortar. It showed that epoxy resin mortar especially was to have high strength in bending and splitting tensile strength. Also, the initial strength within 24 hours gave rise to high value. Thus it was clear that epoxy resin was rapid hardening material. The multiple regression equations of strength were computed depending on a function of mixing ratios and curing times. 5.The elastic moduli derived from the compressive stress-strain curve were slightly smaller than the value of cement mortar, and the toughness of epoxy resin mortar was larger than that of cement mortar. 6.The impact resistance was strong compared with cement mortar at all mixing ratios. Especially, bending impact strength by the square pillar specimens was higher than the impact resistance of flat specimens or cylinderic specimens. 7.The Brinell hardness was relatively larger than that of cement mortar, but it gradually decreased with the decline of mixing ratio, and Brinell hardness at mixing ratio of 1 :14 was much the same as cement mortar. 8.The abrasion rate of epoxy resin mortar at all mixing ratio, when Losangeles abation testing machine revolved 500 times, was very low. Even mixing ratio of 1 :14 was no more than 31.41%, which was less than critical abrasion rate 40% of coarse aggregate for cement concrete. Consequently, the abrasion rate of epoxy resin mortar was superior to cement mortar, and the relation between abrasion rate and Brinell hardness was highly significant as exponential curve. 9.The highest bond strength of epoxy resin mortar was 12.9 kg/cm$^2$ at the mixing ratio of 1:2. The failure of bonded flat steel specimens occurred on the part of epoxy resin mortar at the mixing ratio of 1: 2 and 1: 4, and that of bonded cement concrete specimens was fond on the part of combained concrete at the mixing ratio of 1 : 2 ,1: 4 and 1: 6. It was confirmed that the optimum mixing ratio for bonding of steel plate, and of cement concrete should be rich mixing ratio above 1 : 4 and 1 : 6 respectively. 10.The variations of color tone by heating began to take place at about 60˚C, and the ultimate change occurred at 120˚C. The compressive, bending and splitting tensile strengths increased with rising temperature up to 80˚ C, but these rapidly decreased when temperature was above 800 C. Accordingly, it was evident that the resistance temperature of epoxy resin mortar was about 80˚C which was generally considered lower than that of the other concrete materials. But it is likely that there is no problem in epoxy resin mortar when used for unnecessary materials of high temperature resistance. The multiple regression equations of strength were computed depending on a function of mixing ratios and heating temperatures. 11.The susceptibility to chemical attack of cement mortar was easily affected by inorganic and organic acid. and that of epoxy resin mortar with mixing ratio of 1: 4 was of great resistance. On the other hand, when mixing ratio was lower than 1 : 8 epoxy resin mortar had very poor resistance, especially being poor resistant to organicacid. Therefore, for the structures requiring chemical resistance optimum mixing of epoxy resin mortar should be rich mixing ratio higher than 1: 4.

  • PDF

시공단계 구조해석을 통한 적층형 모듈러주택의 시공조건 검토 (A Study on Construction Condition of Modular System by Structural Analysis of Construction Stage)

  • 조민주;김종성;유성용;최기봉
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권2호
    • /
    • pp.143-150
    • /
    • 2015
  • 현재 국내 모듈러 구조물은 저층의 단독주택 및 군 병영생활관에 한정되어 있는 실정이며, 적층식 모듈러 구조물에 대한 표준화된 구조설계 방법이 없으므로 구조물의 시공과정에서 모듈의 양중이나 운송 시 발생되는 관성력, 양중 시 구조물에 대한 풍하중의 영향, 모듈의 적층 설치 시 충격력 등에 대한 검토가 일반적으로 이루어지고 있지 않다. 따라서 본 연구에서는 대상 모듈러 시스템에 대한 단계별 시공방법을 살펴보고, 각 시공단계에 대한 구조해석 시 경계조건 및 하중 작용위치를 결정하였다. 또한 모듈의 양중 및 차량운반 시 각각의 속도에 따른 관성력을 산정하였으며 모듈의 적층설치 작업 시 양중속도에 따른 충격하중과 양중에 의한 설치작업 시 순간풍속에 의한 풍하중을 산정하였다. 제안된 방법을 토대로 대상 모듈러 시스템에서 양중 시와 운송 시, 설치 시 등 시공단계별 하중크기 결정조건을 변화시켜 구조검토를 수행하였으며 구조적으로 안전성이 확보되는 시공조건을 도출하였다.

수치모의를 통한 원자력 발전소 심층 취·배수 구조물 유·출입구 주변에서의 수리학적 흐름특성 고찰 (Investigation of Hydraulic Flow Properties around the Mouths of Deep Intake and Discharge Structures at Nuclear Power Plant by Numerical Model)

  • 이상화;이성면;박병준;이한승
    • 대한토목학회논문집
    • /
    • 제32권2A호
    • /
    • pp.123-130
    • /
    • 2012
  • 증기를 발생시켜 터빈(turbine)을 회전시키는 화력 및 원자력 발전 계통에서 냉각시설은 필수적인 구조물이며, 냉각수 순환 계통은 일반적으로 해수를 취수하여 발전소 내의 복수기까지 유입시켜 증기와 열 교환 후 다시 외해로 배출시키는 형태를 취하고 있다. 최근 냉각수 취 배수 방식을 표층 취 배수 방식이 아닌 심층 취 배수 방식으로 변경하고 있는데, 기존 원전의 재순환 온도에 대한 영향을 최소화 하고, 온배수 방류시 밀도차로 인한 부력으로 온배수 혼합효과를 높여 온배수에 의한 환경피해 범위를 최소화하기 위해서이다. 특히, 하절기에 저층의 저온 냉각수를 취수할 수 있다는 이점 때문에 향후 계획되는 발전소들도 심층 취 배수 방식을 도입할 것으로 예상된다. 본 연구에서는 원자력 발전소의 냉각시설 중 심층 취 배수 구조물의 입구 주변을 3차원 전산유체역학 코드인 $FLOW-3D^{(R)}$로 모사하여 그 흐름특성을 분석하였다. 취수구(intake)의 경우 연직취수 조건에서 유속 덮개(Velocity cap), 배수구(diffuser)의 경우 방류수의 분사방향에 변화를 주어 모의하였으며, 그 결과 취수구의 경우 유속덮개에 의한 연직 유속성분의 현저한 감소로 인한 어류 유입영향을 최소화할 수 있을 것으로 판단되며, 배수구 희석효과는 Jirka 및 Harleman이 제시한 2차원 온배수 프룸(frume)과 잘 일치 하는 것으로 나타났다.

국내 조적조 건물의 내진성능평가 및 지진피해율 상정 (Evaluation of Seismic Capacity and Estimation of Earthquake Damage for Existing Unreinforced Masonry Building in Korea)

  • 강대언;이원호
    • 콘크리트학회논문집
    • /
    • 제18권4호
    • /
    • pp.535-542
    • /
    • 2006
  • 본 연구에서는 향후 국내의 실정에 맞는 조적조 건물의 내진성능 평가방법의 개발에 기초적인 자료제공을 목적으로 지진에 무방비 상태로 노출된 조적조 건축물 특히 서울시내 50개동의 조적조 건물들을 대상으로 기존 건축물의 구조내진 성능 평가에 관한 기술지침(안)의 방법에 따라 건물의 내진성능을 평가하고 구조내진지표의 분포특성 및 지진피해율을 통계 확률론에 입각하여 검토한 결과, 다음과 같은 결론을 얻었다. 그, 결과, 국내의 현존 조적조 건물의 경년지표(T)를 1에서 0.7사이로 가정하고, 평균전단 응력도를 0.2MPa로 가정 시 표준정규분포로 근사가 가능하다는 것을 알았으며, 조사 대상건물은 경년지표의 변화에 따라 국내 상정 입력지진가속도 레벨에서도 $8{\sim}48%$정도의 내진보강이 필요한 것으로 나타났다. 또한, 국내 상정 입력지진가속도 레벨인 0.12g에 대해서 $11.5{\sim}37.4%$정도의 지진피해율이 상정되었으며 일본의 대표적인 피해지진레벨(0.23g) 뿐만 아니라 중규모의 지진에서도 큰 피해를 받을 것으로 사료된다. 따라서 국내실정에 적합한 내진진단법, 이를 근거로 한 보강건물의 합리적인 선정방법 및 효과적인 내진보강공법이 개발이 시급하다고 판단된다.

Sn-3.0Ag-0.5Cu, Sn-0.7Cu 및 Sn-0.3Ag-0.5Cu 합금의 제조 및 특성평가 (Fabrication and characterization of Sn-3.0Ag-0.5Cu, Sn-0.7Cu and Sn-0.3Ag-0.5Cu alloys)

  • 이정일;팽종민;조현수;양수민;류정호
    • 한국결정성장학회지
    • /
    • 제28권3호
    • /
    • pp.130-134
    • /
    • 2018
  • 솔더(solder) 재료는 수 천년 이상 인류 문명과 함께해온 대표적인 금속 합금으로서 현재까지도 전자 패키징(electronic packaging) 및 표면 실장(SMT, surface mount technology) 분야의 핵심 소재로 사용되고 있다 그러나 최근 Ag 가격의 급격한 상승과 전자산업의 저가격화 전략으로 인해 솔더 재료에서의 Ag 함량의 감소가 지속적으로 요구되고 있다. 본 연구에서는 Sn-3.0Ag-0.5Cu, Sn-0.7Cu 및 Sn-0.3Ag-0.5Cu(weight%) 조성의 무연납 솔더바 샘플을 주조법으로 합금화 하였다. 제조한 Sn-3.0Ag-0.5Cu, Sn-0.7Cu 및 Sn-0.3Ag-0.5Cu 샘플에 대한 결정구조, 화학조성 및 미세구조를 XRD, XRF, 광학현미경, FE-SEM 및 EDS 분석을 이용하여 조사하였다. 분석결과, 제조된 샘플은 ${\beta}-Sn$, ${\varepsilon}-Ag_3Sn$${\eta}-Cu_6Sn_5$ 결정으로 구성되어 있었을 확인할 수 있었다.