• 제목/요약/키워드: low-damage design

검색결과 321건 처리시간 0.029초

Structural health monitoring of seismically vulnerable RC frames under lateral cyclic loading

  • Chalioris, Constantin E.;Voutetaki, Maristella E.;Liolios, Angelos A.
    • Earthquakes and Structures
    • /
    • 제19권1호
    • /
    • pp.29-44
    • /
    • 2020
  • The effectiveness and the sensitivity of a Wireless impedance/Admittance Monitoring System (WiAMS) for the prompt damage diagnosis of two single-storey single-span Reinforced Concrete (RC) frames under cyclic loading is experimentally investigated. The geometrical and the reinforcement characteristics of the RC structural members of the frames represent typical old RC frame structure without consideration of seismic design criteria. The columns of the frames are vulnerable to shear failure under lateral load due to their low height-to-depth ratio and insufficient transverse reinforcement. The proposed Structural Health Monitoring (SHM) system comprises of specially manufactured autonomous portable devices that acquire the in-situ voltage frequency responses of a network of twenty piezoelectric transducers mounted to the RC frames. Measurements of external and internal small-sized piezoelectric patches are utilized for damage localization and assessment at various and increased damage levels as the magnitude of the imposed lateral cycle deformations increases. A bare RC frame and a strengthened one using a pair of steel crossed tension-ties (X-bracing) have been tested in order to check the sensitivity of the developed WiAMS in different structural conditions since crack propagation, damage locations and failure mode of the examined frames vary. Indeed, the imposed loading caused brittle shear failure to the column of the bare frame and the formation of plastic hinges at the beam ends of the X-braced frame. Test results highlighted the ability of the proposed SHM to identify incipient damages due to concrete cracking and steel yielding since promising early indication of the forthcoming critical failures before any visible sign has been obtained.

유한요소기반 다중스케일 연성파손모사 기법을 이용한 원주방향 균열이 존재하는 탄소강 실배관의 파손예측 및 검증 (Finite Element Based Multi-Scale Ductile Failure Simulation of Full-Scale Pipes with a Circumferential Crack in a Low Carbon Steel)

  • 한재준;배경동;김윤재;김종현;김낙현
    • 대한기계학회논문집A
    • /
    • 제38권7호
    • /
    • pp.727-734
    • /
    • 2014
  • 본 논문은 유한요소 기반 다중스케일 연성파손모사 기법을 이용하여 결함이 존재하는 실배관의 파괴거동을 예측한다. 수정응력 파괴변형률 모델을 손상기준으로 선정하고 유한요소 손상해석을 통해 균열진전을 모사한다. 기준식의 결정에는 인장시험과 파괴인성시험 결과만이 요구되며 온도 $288^{\circ}C$ SA333 Gr. 6 탄소강에 적용하여 결과를 제시하였다. 요소크기-의존성 임계손상모델을 도입하여 손상해석의 수치해석적인 불안정성을 개선하였다. 본 연구에서 제안하는 가상시험법의 검증을 위해 미국 바텔 연구소에서 수행한 실배관 실험결과와 예측결과를 비교한다.

HAZUS틀을 사용한 서울시 강남구의 건축물 지진피해에 따른 직접적 경제손실 예측 (Earthquake Direct Economic Loss Estimation of Building Structures in Gangnam-Gu District in Seoul Using HAZUS Framework)

  • 정기현;이한선;권오성;황경란
    • 한국지진공학회논문집
    • /
    • 제20권6호
    • /
    • pp.391-400
    • /
    • 2016
  • For earthquake loss estimation of building structures in Gangnam-Gu district in Seoul, three scenario earthquakes were selected by comparison of the response spectra of these scenario earthquakes with the design spectrum in Korean Building Code (KBC 2009), and then direct losses of the building structures in the Gangnam-Gu district under each scenario earthquake are estimated. The following conclusions are drawn from the results of damage and loss in the second scenario earthquake, which has a magnitude = 6.5 and epicentral distance =15 km: (1) The ratio of building stocks undergoing the extensive and complete damage level is 40.0% of the total. (2) The amount of direct economic losses appears approximately 19 trillion won, which is 1.2% of the national GDP of Korea. (3) About 25% of high-rise (over 10-story) RC building wall structures, were inflicted with the damage exceeding moderate level, when compared to 60% of low-rise building structures. (4) From the economical view point, the main loss, approximately 50%, was caused by the damage in the high-rise RC wall building structures.

초고층 건축물 매트 기초용 고성능 콘크리트 내구성 평가 (Durability Evaluation of High-Performance, Low-Heat Self-Compacting Concrete for Foundation of Tall Buildings)

  • 김영봉;박동천
    • 한국건축시공학회지
    • /
    • 제22권5호
    • /
    • pp.425-430
    • /
    • 2022
  • 초고층 건축물용 매트기초에 사용되는 콘크리트는 시공성 및 품질확보를 위하여 일체타설로 진행되는 경우가 많다. 하지만 일체타설의 경우 수화반응 과정에서 온도균열이 발행할 우려가 높으며 혼화재 치환을 통해 고성능 고내구성 콘크리트 최적배합을 도출할 필요가 있다. 본 연구에서는 저자의 기존연구에서 도출한 최적 고성능 저발열 콘크리트 배합으로 제작된 시험체를 대상으로 염해 및 탄산화, 내황산염에 대한 실험을 실시하고 염소이온 확산계수와 탄산화계수, 황산염에 대한 시멘트 매트릭스의 저항을 정량적으로 평가하였다. 혼화재의 혼입에 의한 잠재수경성 및 포졸란 반응에 의한 높은 저항성을 확인할 수 있었다.

Seismic deformation demands on rectangular structural walls in frame-wall systems

  • Kazaz, Ilker
    • Earthquakes and Structures
    • /
    • 제10권2호
    • /
    • pp.329-350
    • /
    • 2016
  • A parametric study was conducted to investigate the seismic deformation demands in terms of drift ratio, plastic base rotation and compression strain on rectangular wall members in frame-wall systems. The wall index defined as ratio of total wall area to the floor plan area was kept as variable in frame-wall models and its relation with the seismic demand at the base of the wall was investigated. The wall indexes of analyzed models are in the range of 0.2-2%. 4, 8 and 12-story frame-wall models were created. The seismic behavior of frame-wall models were calculated using nonlinear time-history analysis and design spectrum matched ground motion set. Analyses results revealed that the increased wall index led to significant reduction in the top and inter-story displacement demands especially for 4-story models. The calculated average inter-story drift decreased from 1.5% to 0.5% for 4-story models. The average drift ratio in 8- and 12-story models has changed from approximately 1.5% to 0.75%. As the wall index increases, the dispersion in the calculated drifts due to ground motion variability decreased considerably. This is mainly due to increase in the lateral stiffness of models that leads their fundamental period of vibration to fall into zone of the response spectra that has smaller dispersion for scaled ground motion data set. When walls were assessed according to plastic rotation limits defined in ASCE/SEI 41, it was seen that the walls in frame-wall systems with low wall index in the range of 0.2-0.6% could seldom survive the design earthquake without major damage. Concrete compressive strains calculated in all frame-wall structures were much higher than the limit allowed for design, ${\varepsilon}_c$=0.0035, so confinement is required at the boundaries. For rectangular walls above the wall index value of 1.0% nearly all walls assure at least life safety (LS) performance criteria. It is proposed that in the design of dual systems where frames and walls are connected by link and transverse beams, the minimum value of wall index should be greater than 0.6%, in order to prevent excessive damage to wall members.

인버터 저항용접기의 전력효율 향상을 위한 AC/DC 컨버터 설계에 관한 연구 (A Study on AC/DC Converter Design of High Efficiency for Inverter Resistance Welder)

  • 곽동걸;정원석;강우철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.40-41
    • /
    • 2016
  • The inverter resistance welder requires AC/DC converter of high efficiency because the converter changes a commercial ac power source to low voltage dc power source. Harmonic components that occur in the conversion process of converter decrease system power factor and deal great damage in electric power system. To improve such problems, this paper proposes a high efficiency AC/DC converter for inverter resistance welder. The switching devices in the proposed converter are operated by soft switching technique using a new quasi-resonant circuit. As a result, the proposed AC/DC converter obtains low switching power loss and high efficiency.

  • PDF

섬유업체 근로여성의 작업복 실태 및 선호연구 (Female Workers' Uniform Preference of the Fiber Firms)

  • 이옥희
    • 대한가정학회지
    • /
    • 제35권4호
    • /
    • pp.185-198
    • /
    • 1997
  • This study was initiated to research on the uniform preference uniform satisfaction and wearing of female workers' uniform of the fiber firms. Data was obtained from 361 female workers of the fiber firms in Chon Buk. And it was analyzed by frequency percent mean duncan's multiple test. The results of this study were as follows; 1) Pocket sleeve and front hem were parts of the damage. The weaving workers were mostly wore upper and under garments but most of there workers were only wore an upper garment on the basic type of uniform The older and married were small in the fitness of uniform the armhole sleeve girth sleeve length and breast girth were unfitted 2) Workers was dissatisfied to the noise and the dust in working environment. Uniform satisfaction of workers were mostly low design color and fabric were the lowest factors of uniform satisfaction. The satisfaction of material were also low the lowest factors were absorptiveness elasticity breathability. Workers wanted the fashion and light colored uniform but they prefered function activity to work and manageability on wearing rather than externals among the uniform preference.

  • PDF

저온하에서 CFRP 적층재의 충격 손상과 잔류 강도 -저/고온하에서 CFRP 적층재의 충격 손상을 중심으로 - (A Study on the Impact Damage and Residual Strength of CFRP Composite Laminates under Low Temperature)

  • 양인영;정종안;차천석
    • 비파괴검사학회지
    • /
    • 제17권1호
    • /
    • pp.1-10
    • /
    • 1997
  • 본 연구에서는 첨단 재료인 CFRP 적층재가 저온 및 고온 분위기하에서 FOD를 받을 때 적층 부재의 충격 손상 즉, 온도 변화가 층간 박리 손상 및 모재 크랙 발생에 미치는 영향에 관해 관찰하였다. 연구 결과 주변온도가 CFRP 적층재의 충격 손상에 큰 영향을 미쳤으며 적층수가 많을수록 손상 박리 면적은 주변 온도의 변화에 따라 급격히 변화함을 알 수 있었다. 특히, CF/PEEK 적층재는 주변 온도가 낮아질수록 박리 면적은 급격히 증가하나 모재 크랙은 작아졌고 CF/epoxy 적층재는 온도가 낮아질수록 박리 면적, 모재 크랙 모두 커졌다. 즉, 시험편 표면 온도가 낮아지면 단위 충격 에너지당 박리 면적($m^2/J$)이 크게 되어 온도가 저하할수록 임계 박리 에너지가 작게되며, 박리를 생기게 하는 초기 손상 에너지가 작게 되어 박리 발생이 쉽게 됨을 알 수 있었다.

  • PDF

극저준위 콘크리트, 금속 해체방폐물의 방사선적 특성을 고려한 매립형 처분시설 방사선작업자 예비 피폭선량 평가 (Preliminary Radiation Exposure Dose Evaluation for Workers of the Landfill Disposal Facility Considering the Radiological Characteristics of Very Low Level Concrete and Metal Decommissioning Wastes)

  • 도호석;조예슬;강현구;하재철
    • 방사선산업학회지
    • /
    • 제17권4호
    • /
    • pp.509-518
    • /
    • 2023
  • The Kori Unit 1 nuclear power plant, which is planned to be dismantled after permanent shutdown, is expected to generate a large amount of various types of radioactive waste during the dismantling process. For the disposal of Very-low-level waste, which is expected to account for the largest amount of generation, the Korea Radioactive waste Agency (KORAD) is in the process of detailed design to build a 3-phase landfill disposal facility in Gyeongju. In addition, a large container is being developed to efficiently dispose of metal and concrete waste, which are mainly generated as Very low-level waste of decommissioning. In this study, based on the design characteristics of the 3-phase landfill disposal facility and the large container under development, radiation exposure dose evaluation was performed considering the normal and accident scenarios of radiation workers during operation. The direct exposure dose evaluation of workers during normal operation was performed using the MCNP computer program, and the internal and external exposure dose evaluation due to damage to the decommissioning waste package during a drop accident was performed based on the evaluation method of ICRP. For the assumed scenario, the exposure dose of worker was calculated to determine whether the exposure dose standards in the domestic nuclear safety act were satisfied. As a result of the evaluation, it was confirmed that the result was quite low, and the result that satisfied the standard limit was confirmed, and the radiational disposal suitability for the 3-phase landfill disposal facility of the large container for dismantled radioactive waste, which is currently under development, was confirmed.

저속 2행정 디젤엔진의 과도 비틀림 진동에 의한 축계 피로 강도에 관한 연구 (A Study on Shaft Fatigue Strength due to Torsional Vibrations in Two Stroke Low Speed Diesel Engines)

  • 이돈출;김상환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.786-791
    • /
    • 2006
  • Two stroke low speed diesel engines are mainly used for marine propulsion or power plant prime mover. These have many merits such as higher thermal efficiency, mobility and durability. However various annoying vibrations sometimes occur in ships or at the plant itself. Of these vibrations, torsional vibration is very important and it should be carefully investigated during the initial design stage for engine's safe operation. In this paper authors suggest a new estimation method of for shaft's can be calculated equivalently from accumulated fatigue cycles number due to torsional vibration. The 6S70MC-C($25,320ps{\times}91rpm$) engine for ship propulsion was selected as a case study, and the accumulated fatigue cycles numbers for shafting life time converted from the measured angular velocity and torsional vibration stress was calculated. This new method can be realized and confirmed in test model ship with two stroke low speed diesel engine.

  • PDF