• 제목/요약/키워드: low radiation

검색결과 2,581건 처리시간 0.033초

치과에서의 방사선안전관리 (Radiation protection in dental clinic)

  • 이삼선
    • Imaging Science in Dentistry
    • /
    • 제37권3호
    • /
    • pp.117-126
    • /
    • 2007
  • Although the diagnostic information provided by radiographs may be of definite benefit to the patients, the radiographic examination does carry the potential for harm from exposure to ionizing radiation. Therefore we should try to expose radiation as low as reasonably achievable and to give diagnostic information to patients as much as possible. All of dentists should have competence in radiation protection. I wish to deal with what we should do for the optimization of radiation protection in dental clinic.

  • PDF

PRELIMINARY STUDY OF WATER CONTENTS AND SIGNAL BEHAVIOR IN FINGERNAIL/EPR DOSIMETRY

  • Choi, Hoon;Choi, Sul A;Lee, Byungil
    • Journal of Radiation Protection and Research
    • /
    • 제38권4호
    • /
    • pp.185-188
    • /
    • 2013
  • Heating method using electric heater was used to reduce water content in fingernail clippings. Authors found that low water content is helpful to measure EPR signal of fingernail sample with enhanced variability. Generally, natural dehydration happens in normal room condition at least one month and needs much time for using in experiment. So, artificial heating method is applied in this study for time savings. Fingernail samples were tested to find effect of water content to the EPR signal on microwave power levels for dosimetry. Low water content in fingernail reduced variability of EPR signal and makes it possible to measure accurate EPR signal. It also made it possible to measure constant movement of EPR signals on several microwave power levels. Although this method was difficult to apply directly in fingernail/EPR dosimetry, we, authors, believe that this heating method would be useful to differentiate MIS2 and RIS which are generally located at the same g-factor and almost impossible to be identified with each other.

Radioprotective effects of delphinidin on normal human lung cells against proton beam exposure

  • Kim, Hyun Mi;Kim, Suk Hee;Kang, Bo Sun
    • Nutrition Research and Practice
    • /
    • 제12권1호
    • /
    • pp.41-46
    • /
    • 2018
  • BACKGROUND/OBJECTIVES: Exposure of the normal lung tissue around the cancerous tumor during radiotherapy causes serious side effects such as pneumonitis and pulmonary fibrosis. Radioprotectors used during cancer radiotherapy could protect the patient from side effects induced by radiation injury of the normal tissue. Delphinidin has strong antioxidant properties, and it works as the driving force of a radioprotective effect by scavenging radiation-induced reactive oxygen species (ROS). However, no studies have been conducted on the radioprotective effect of delphinidin against high linear energy transfer radiation. Therefore, this study was undertaken to evaluate the radioprotective effects of delphinidin on human lung cells against a proton beam. MATERIALS/METHODS: Normal human lung cells (HEL 299 cells) were used for in vitro experiments. The 3-[4,5-dimethylthiazol-2-yl]-2,5 diphenyl tetrazolium bromide (MTT) assay assessed the cytotoxicity of delphinidin and cell viability. The expression of radiation induced cellular ROS was measured by the 2'-7'-dicholordihydrofluorescein diacetate assay. Superoxide dismutase activity assay and catalase activity assay were used for evaluating the activity of corresponding enzymes. In addition, radioprotective effects on DNA damage-induced cellular apoptosis were evaluated by Western blot assay. RESULTS: Experimental analysis, including cell survival assay, MTT assay, and Western blot assay, revealed the radioprotective effects of delphinidin. These include restoring the activities of antioxidant enzymes of damaged cells, increase in the levels of pro-survival protein, and decrease of pro-apoptosis proteins. The results from different experiments were compatible with each to provide a substantial conclusion. CONCLUSION: Low concentration ($2.5{\mu}M/mL$) of delphinidin administration prior to radiation exposure was radioprotective against a low dose of proton beam exposure. Hence, delphinidin is a promising shielding agent against radiation, protecting the normal tissues around a cancerous tumor, which are unintentionally exposed to low doses of radiation during proton therapy.

Development of an efficient method of radiation characteristic analysis using a portable simultaneous measurement system for neutron and gamma-ray

  • Jin, Dong-Sik;Hong, Yong-Ho;Kim, Hui-Gyeong;Kwak, Sang-Soo;Lee, Jae-Geun;Jung, Young-Suk
    • 분석과학
    • /
    • 제35권2호
    • /
    • pp.69-81
    • /
    • 2022
  • The method of measuring and classifying the energy category of neutrons directly using raw data acquired through a CZT detector is not satisfactory, in terms of accuracy and efficiency, because of its poor energy resolution and low measurement efficiency. Moreover, this method of measuring and analyzing the characteristics of low-energy or low-activity gamma-ray sources might be not accurate and efficient in the case of neutrons because of various factors, such as the noise of the CZT detector itself and the influence of environmental radiation. We have therefore developed an efficient method of analyzing radiation characteristics using a neutron and gamma-ray analysis algorithm for the rapid and clear identification of the type, energy, and radioactivity of gamma-ray sources as well as the detection and classification of the energy category (fast or thermal neutrons) of neutron sources, employing raw data acquired through a CZT detector. The neutron analysis algorithm is based on the fact that in the energy-spectrum channel of 558.6 keV emitted in the nuclear reaction 113Cd + 1n → 114Cd + in the CZT detector, there is a notable difference in detection information between a CZT detector without a PE modulator and a CZT detector with a PE modulator, but there is no significant difference between the two detectors in other energy-spectrum channels. In addition, the gamma-ray analysis algorithm uses the difference in the detection information of the CZT detector between the unique characteristic energy-spectrum channel of a gamma-ray source and other channels. This efficient method of analyzing radiation characteristics is expected to be useful for the rapid radiation detection and accurate information collection on radiation sources, which are required to minimize radiation damage and manage accidents in national disaster situations, such as large-scale radioactivity leak accidents at nuclear power plants or nuclear material handling facilities.

A LONG-TERM FIELD TEST OF A LARGE VOLUME IONIZATION CHAMBER BASED AREA RADIATION MONITORING SYSTEM DEVELOPED AT KAERI

  • Kim, Han-Soo;Ha, Jang-Ho;Park, Se-Hwan;Kim, Jung-Bok;Kim, Young-Kyun;Jin, Hyung-Ho
    • Journal of Radiation Protection and Research
    • /
    • 제34권2호
    • /
    • pp.77-81
    • /
    • 2009
  • An Area Radiation Monitoring System (ARMS) ionization chamber, which had an 11.8 L active volume, was fabricated and performance-tested at KAERI. Low leakage currents, linearities at low and high dose rates were achieved from performance tests. The correlation coefficients between the ionization currents and the dose rates are 1 at high dose rate and 0.99 at low dose rate. In this study, an integration-type ARMS ionization chamber was tested over a year for an evaluation of its long-term stability at a radioisotope (RI) repository of the Young-gwang nuclear power plant. The standard deviation of dose rate of 1 day data and over a 100-days mean value were 6.2 $\mu$R/h and 2.9 $\mu$R/h, respectively. The fabricated ARMS ionization chamber showed stable performance from the results of the long-term tests. Design and performance characteristics of the fabricated ionization chamber for the ARMS from performance-tests are also addressed.

저선량 $\gamma$선 조사가 토마토의 초기생육과 후속고선량 $\gamma$선 저항성에 미치는 영향 (Effects of low dose $\gamma$-ray on the early growth of tomato and the resistance to subsequent high doses of radiation)

  • 김재성;김진규;백명화;김동희
    • Journal of Radiation Protection and Research
    • /
    • 제24권3호
    • /
    • pp.123-129
    • /
    • 1999
  • 저선량 $\gamma$선 조사한 토마토 2품종, 서광과 하우스모모타로 종자의 발아와 초기생육 및 후속 고선량에 대한 생육효과를 조사하였다. 저선량에 의한 발아와 생육촉진효과는 품종에 따라 달랐다. 발아율의 경우 서광은 모든 저선량 조사구에서 증가되었으나, 하우스모모타로는 오히려 감소되었다. 유묘초장은 저선량 조사에 의해 증가되었으며 두 품종 모두 4 Gy와 8 Gy 조사구에서 가장 효과적이었다. 생육 2개월 후 서광의 초장은 억제되었으나 생체중은 4 Gy와 2 Gy에서 증가되었고, 하우스모모타로의 초장은 12 Gy와 20 Gy에서, 생체중은 20 Gy와 4 Gy에서 가장 높은 증가효과를 보였다. 토마토 식물체의 고선량 피폭에 의한 생육장해는 사전 저선량 조사에 의해 감소되었는데 서광의 경우 2 Gy와 8 Gy 조사구에서 저항성이 높았으며 하우스모모타로의 경우 모든 저선량 조사구에서 저항성 효과가 나타났으며 특히 2 Gy와 12 Gy 조사구에서 높았다.

  • PDF

Assessment of Dose Distributions According to Low Magnetic Field Effect for Prostate SABR

  • Son, Jaeman;An, Hyun Joon;Choi, Chang Heon;Chie, Eui Kyu;Kim, Jin Ho;Park, Jong Min;Kim, Jung-in
    • Journal of Radiation Protection and Research
    • /
    • 제44권1호
    • /
    • pp.26-31
    • /
    • 2019
  • Background: Stereotactic ablative radiotherapy (SABR) plans in prostate cancer are compared and analyzed to investigate the low magnetic effect (0.35 T) on the dose distribution, with various dosimetric parameters according to low magnetic field. Materials and Methods: Twenty patients who received a 36.25 Gy in five fractions using the MR-IGRT system (ViewRay) were studied. For planning target volume (PTV), the point mean dose ($D_{mean}$), maximum dose ($D_{max}$), minimum dose ($D_{min}$) and volumes receiving 100% ($V_{100%}$), 95% ($V_{95%}$), and 90% ($V_{90%}$) of the total dose. For organs-at-risk (OARs), the differences compared using $D_{max}$, $V_{50%}$, $V_{80%}$, $V_{90%}$, and $V_{100%}$ of the rectum; $D_{max}$, $V_{50%}$, $V_{30Gy}$, $V_{100%}$ of the bladder; and $V_{30Gy}$ of both left and right femoral heads. For both the outer and inner shells near the skin, $D_{mean}$, $D_{min}$, and $D_{max}$ were compared. Results and Discussion: In PTV analysis, the maximum difference in volumes ($V_{100%}$, $V_{95%}$, and $V_{90%}$) according to low magnetic field was $0.54{\pm}0.63%$ in $V_{100%}$. For OAR, there was no significant difference of dose distribution on account of the low magnetic field. In results of the shells, although there were no noticeable differences in dose distribution, the average difference of dose distribution for the outer shell was $1.28{\pm}1.08Gy$ for $D_{max}$. Conclusion: In the PTV and OARs for prostate cancer, there are no statistically-significant differences between the plan calculated with and without a magnetic field. However, we confirm that the dose distribution significantly increases near the body shell when a magnetic field is applied.