• Title/Summary/Keyword: low radiation

Search Result 2,615, Processing Time 0.035 seconds

Effects of Non-drainage Hydroponic Culture on Growth, Yield, Quality and Root Environments of Muskmelon (Cucumis melo L.) (멜론 수경재배 시 배액제로화가 근권환경 및 수량에 미치는 영향)

  • Chang, Young Ho;Hwang, Yeon Hyeon;An, Chul Geon;Yoon, Hae Suk;An, Jae Uk;Lim, Chae Shin;Shon, Gil Man
    • Journal of Bio-Environment Control
    • /
    • v.21 no.4
    • /
    • pp.348-353
    • /
    • 2012
  • This study was conducted to figure out the possibility of non-drainage in muskmelon (Cucumis melo L.) hydroponics culture. Plants were grown under 3 different levels of drainage, standard (20~40%, SD), minimum (5~10%, MD), and non-drainage (ND). Throughout cultivation periods, constant water content and electrolyte conductivity changes in root zone were observed in SD in the range of 60~70% and $1.5{\sim}2.5dS{\cdot}m^{-1}$, respectively. ND treatment caused the fluctuation in water content and electrolyte conductivity of root zone and its change ranges were 30~50% in water content and $2{\sim}6dS{\cdot}m^{-1}$ in electrolyte conductivity, but ND treatment did not decrease fruit quality. Even if fruit fresh weight was slightly lower in ND with 1,863 g, than in SD with 1,990 g, the fruit weight in ND meets standard market size, 1,800~2,000 g. Higher soluble solids content was observed in fruit in ND than in SD and MD. Total amount of drainage per plant was 27,718, 15,769 and 2,346 mL in SD, MD and ND, respectively. SD showed $83.2m^3$ drainage, 34.5% drainage of irrigation amount whereas required total irrigation amount in ND was very low with $7m^3$.

Photocatalytic Degradation of Fungicide Chlorothalonil by Mesoporous Titanium Oxo-Phosphate (Mesoporous Titanium Oxo-Phosphate에 의한 살균제 Chlorothalonil의 광분해)

  • Choi, Choong-Lyeal;Kim, Byung-Ha;Lee, Byung-Mook;Choi, Jyung;Rhee, In-Koo;Kim, Jang-Eok
    • Korean Journal of Environmental Agriculture
    • /
    • v.22 no.4
    • /
    • pp.284-289
    • /
    • 2003
  • Titanium mesoporous materials have received increasing attention as a new photocatalyst in the field for photocatalytic degradation of organic compounds. The photocatalytic degradation of chlorothalonil by mesoporous titanium oxo-phoswhate (Ti-MCM) was investigated in aqueous suspension for comparison with $TiO_2$, (Degussa, P25) using as an effective photocatalyst of organic pollutants. Mesoporous form of titanium Phosphate has been prepared by reaction of sulfuric acid and titanium isopropoxide in the presence or n-hexadecyltrimethylammonium bromide. The XRD patterns of Ti-MCM are hexagonal phases with d-spacings of 4.1 nm. Its adsorption isotherm for chlorothalonil reached at reaction equilibrium within 60 min under dark condition with 28% degradation efficiency. The degradation ratio of chlorothalonil after 9 hours under the UV radiation condition (254 nm) exhibited 100% by Ti-MCM and 88% by $TiO_2$. However, these degradation kinetics in static state showed a slow tendency compared to that of stirred state because of a low contact between titanium matrices and chlorothalonil. Also, degradation efficiency of chlorothalonil was increased with decreasing initial concentration and with increasing pH of solution. As results of this study, it was clear that mesoporous titanium oxo-phosphate with high surface area and crystallinity could be used to photo- catalytic degradation of various organic pollutants.

Impact Assessment of Turbidity Water caused Clays on Algae Growth (조류성장에 미치는 점토탁수의 영향평가)

  • Park, Chan-Gab;Kang, Mee-A
    • The Journal of Engineering Geology
    • /
    • v.16 no.4 s.50
    • /
    • pp.403-409
    • /
    • 2006
  • This study was performed to assess the clay impact on alga growth which was a primary producer, in view of food chain in ecosystem. As clay minerals caused turbidity, a low sedimentation, high adsorption capacity with organic matter, adsorption - desorption effect with ionic chemicals, clay minerals were supposed to have a significant effect on the aquatic system. In study we tried to turn out NOAEL (No-observed-adverse-effect-level) of clay materials on the algae growth inhibition using such as kaolinite, sericite and montmorillonite. This study was indicated. (1) In both of kaolinite and sericite, the $72hr-EC_{50}$ of them shows 2,752 mg/L and 2,775 mg/L, respectively. (2) On the other hand, in the case of montmorillonite, the $72hr-EC_{50}$ is not shown a significant difference to that of control samples. (3) It can be explained that is also a very important parameter in an alga growth. Because an alga growth was increased when the permeability of W visible radiation was increased in all clay cases. (4) It is demonstrated alga growth was affected by the characteristics of clay materials. Hence we can assess the $\ulcorner$water environmental risk assessment caused clay materials$\lrcorner$ using the alga growth inhibition level indirectly.

A Study on Radiographical Conditions and Exposure Doses During Chest Radiography at Medical Facilities in Pusan (부산지역 의료기관의 흉부촬영 조건과 피폭선량에 관한 조사연구)

  • Jeon, Sung-Oh;Cho, Young-Ha
    • Journal of radiological science and technology
    • /
    • v.20 no.2
    • /
    • pp.49-55
    • /
    • 1997
  • This study was carried out to investigate radiographical and operating conditions of X-ray units and exposure doses to patients during chest radiography, so that the results could provide basic data used for reducing the exposure dose and for providing the diagnostic information with better quality. The conditions and exposure doses of 100 X-ray units mainly used for chest radiography were examined and also 100 radiological technologists mainly handling those apparatus at 76 medical facilities in Pusan were surveyed using a questionnaire from October 1 to December 31 in 1995. The following results were obtained from the study : 1. It was found that most units were capable of taking a high tube voltage radiography by showing 67% of the units equipped with the maximum tube voltage of 150 kV, 94% with more than 500 mA for the rating capacity and 85% with the full wave type of a signal phase. 2. For actual chest radiographical conditions, however, 80% of the units were operated at $60{\sim}100\;kVp$ and only 14% at 100 kVp and over for the high tube voltage. 3. The average exposure time was less than 0.1 second, and eighty four percent of the units adapted the X-ray tube currents ranging from 200 to 300 mA, 80% the focus-film distances between 180 and 210 cm, and 63% the focus sizes of more than 2.0 mm. 4. Most units(98%) employed additional filters made of aluminum, 75% the thickness of filters less than 2.0 mm, and only 2 units the compound filters. 5. Ortho chromatic system was only adopted in 13% of screen film system for the units, and 73% used the grid ratio at 8 : 1 for the low tube voltage during chest radiography. 6. The average exposure dose of all X-ray units during chest radiography was $371\;{\mu}Sv$ with a difference of about 16 times between the minimum to the maximum, and $386\;{\mu}Sv$ both at hospitals and at health centers, followed by $380\;{\mu}Sv$ at general hospitals and $263\;{\mu}Sv$ at university hospitals without showing any statistically significant differences. In conclusion, since patients during chest radiography at medical facilities in Pusan exposed to high levels of radiation, it is recommended that appropriate added filters and grids necessary for the high tube voltage radiography and high-speed screen systems should be adopted and used as soon as possible in order to reduce exposure dose to the patients.

  • PDF

The Study of Radiation Exposure Reduction by Developing Corpus Striatum Phantom (두개골-선조체 팬텀을 이용한 선량 저감화 방안 연구)

  • Kim, Jung-Soo;Park, Chan-Rok
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.595-603
    • /
    • 2017
  • The study is to produced a brain phantom simulating corpus striatum, which can evaluate the progression of parkinson's disease, to investigate possibility of reducing the brain exposure dose to CT while maintaining optimal image quality during PET-CT examinations. CT scans were performed by varying tube voltage (100, 120 kVp) and tube current (80, 140, 200 mAs) with $^{18}F$ FP-CIT injected into the phantom's hot sphere and background (radioactivity ratio 3:1)(reference condition; 120 kVp, 140 mAs). Estimated effective dose was calculated by using conversion factor according to each condition, and image quality was evaluated by setting SNR and CRChot image evaluation factors. Experimental results showed that the predicted effective dose below the CT imaging reference condition was reduced by at least 10% and by up to 60%, and the predicted effective dose beyond the reference condition was increased by 40%. In addition, there was no significant difference between SNR and CRChot of PET images, and it was confirmed that brain dose decreased with decrease of tube voltage and tube current. At the same time, there was no significant change in the quality of the image in terms of SNR and CRChot despite the change in scan conditions. This fact suggests that the quality of the images acquired under the existing dose conditions can be obtained even at low dose conditions and it is expected that it will be possible to use the brain PET-CT scan as a basic data for the research on reduction of dose and improvement of image quality.

A Study Clinical Analysis of Cervical Spine disease patient's (경추 질환환자의 임상증례 분석연구)

  • Kim, Kee-Bog
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.3
    • /
    • pp.35-40
    • /
    • 2007
  • The purpose of this study was to investigate in S city of Chung-Nam using direction radiation Cervical spine among patient enforcing AP view, lateral view, total 113 subjects(40-year-old low)by target examine and got following as: 1) Distribution of age 14~40 years old 57 men (50.4%), woman 56subjects(49.6%)be, and age group 30~40year old 80subjects(70.8 %), 20~29year old 27subjects(23.9%). 2) It appeared most by 81subjects(71.7%) that can not know cause though traffic accident, misstep, cause ignorantness were investigated to revealed by the chronic 87subjects(77%) appeared by thing which statistical significance is with occurrence cause. 3) 20 Among whole 113subjects 20~29years old 27 subjects(23.9%), 30~40years old 80 subjects(70.8%) manifestationacute form of a disease, the chronic all high distributionsee. 4) This investigator left shoulder region pain among 39 subjects whole 113 subjects (left to direction that could know that is each main pain in 34.5 %), cervical vertebral portion upside 31 subjects(27.4%), both shoulder region pain 20 subjects(17.7%), and becomes left side scoliosis 62 subjects(54.9%)by the most frequencies appear. 5) Appeared antespondylolisthesis by all curve 48 subjects(42.5 %) in curve direction and at Systolic blood pressure from 160mmHg to all 19 subjects (before total 69 subjects (61.0 %) at 16.8 %), Diastolic blood pressures curve 31 subjects(27.4 %) by 100 mmHg appear.

  • PDF

A Numerical Study on the Extinguishing Effects of CO2 in Counterflow Diffusion Flames with the Concept of Local Application System (국소방출방식 개념의 대향류 확산화염에서 CO2 소화효과에 관한 수치해석 연구)

  • Mun, Sun-Yeo;Park, Chung-Hwa;Hwang, Cheol-Hong;Oh, Chang-Bo
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.55-62
    • /
    • 2012
  • The suppression mechanisms of carbon dioxide ($CO_2$) as a representative fire suppression agent were revisited using a counterflow diffusion flame which could be applied the concept of a local application system. To end this, the low strain rate $CH_4$/air counterflow diffusions with $CO_2$ addition in either fuel or oxidizer stream were examined numerically using detailed-kinetic chemistry. Radiative heat loss due to radiating gas species including $CO_2$ added was considered by the optically thin model (OTM). As a result, the critical $CO_2$ volume fractions in the oxidizer stream required to extinguish the flame were in good agreement with the experimental data reported in the literature, while somewhat under-prediction was observed with $CO_2$ added in the fuel stream. The surrogate agents were adopted to estimate the quantitative contribution with changing in global strain rate ($a_g$) on the flame extinguishment among pure dilution effect, thermal effects including radiation heat loss and chemical effect due to the $CO_2$ fire suppression agent.

The Role of Gamma Knife Radiosurgery for Prolactin Secreting Pituitary Adenomas (유즙 호르몬 과분비 선종에 대한 감마 나이프 수술의 역할)

  • Hur, Jin Woo;Lim, Young Jin;Leem, Won;Yang, Jae Young;Koh, Jun Seok;Kim, Tae Sung;Rhee, Bong Arm;Kim, Gook Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.3
    • /
    • pp.336-344
    • /
    • 2000
  • Objective : The treatment for prolactin secreting pituitary adenoma(prolactinoma) include pharmacology, surgery, radiation therapy or radiosurgery. The recent development of radiological imaging and microsurgery has made transsphenoidal microsurgery the treatment of choice for most prolactin secreting pituitary adenoma. Despite its low morbidity and mortality, relatively high recurrence and failure rate have been reported. Recent advances in neuroimaging provide a precise targeting in radiosurgery for treatment of prolactin secreting pituitary adenoma. In this regard, Gamma knife radiosurgery has been proposed as an alternative primary treatment modality or adjuvant therapy. Patients and Methods : Twenty three patients with prolactin secreting pituitary adenoma have been treated with Gamma knife radiosurgery in our institute from March 1992 to September 1998. We analyzed clinical, radiological and endocrinological changes in 21 patients who were followed up for an average of 35.7 months. Results : The mean age was 34.9 years and 16 patients were treated with Gamma knife radiosurgery as primary treatment and 5 patients underwent Gamma knife radiosurgery for residual tumors after microsurgery. The margin of the tumor was incorporated within the 40 to 80% and the mean marginal dose was 24.5 Gy. Clinical improvement in the last follow-up were present in 17 cases(81.0%) and 3 of 5 infertility patients became pregnant after Gamma knife radiosurgery. Tumor control rate after Gamma knife radiosurgery was 100%. Endocrinological normalization in the last follow-up were obtained in 12 cases(57.1%). In three cases, hormonal normalizations were present in early period(3-32 months) but serum hormone levels were elevated subsequently. Conclusion : We conclude that the Gamma knife radiosurgery for prolactin secreting pituitary adenoma seems to be safe and effective as adjuvant therapy after microsurgery and primary treatment modality in selective patients.

  • PDF

Characteristics of Remote Sensors on KOMPSAT-I (다목적 실용위성 1호 탑재 센서의 특성)

  • 조영민;백홍렬
    • Korean Journal of Remote Sensing
    • /
    • v.12 no.1
    • /
    • pp.1-16
    • /
    • 1996
  • Korea Aerospace Research Institute(KARI) is developing a Korea Multi-Purpose Satellite I(KOMPSAT-I) which accommodates Electro-Optical Camera(EOC), Ocean Color Imager(OCI), Space Physics Sensor(SPS) for cartography, ocean color monitoring, and space environment monitoring respectively. The satellite has the weight of about 500 kg and is operated on the sun synchronized orbit with the altitude of 685km, the orbit period of 98 minutes, and the orbit revisit time of 28days. The satellite will be launched in the third quarter of 1999 and its lifetime is more than 3 years. EOC has cartography mission to provide images for the production of scale maps, including digital elevation models, of Korea from a remote earth view in the KOMPSAT orbit. EOC collects panchromatic imagery with the ground sample distance(GSD) of 6.6m and the swath width of 15km at nadir through the visible spectral band of 510-730 nm. EOC scans the ground track of 800km per orbit by push-broom and body pointed method. OCI mission is worldwide ocean color monitoring for the study of biological oceanography. OCI is a multispectral imager generating 6 color ocean images with and <1km GSD by whisk-broom scanning method. OCI is designed to provide on-orbit spectral band selectability in the spectral range from 400nm to 900nm. The color images are collected through 6 primary spectral bands centered at 443, 490, 510, 555, 670, 865nm or 6 spectral bands selected in the spectral range via ground commands after launch. SPS consists of High Energy Particle Detector(HEPD) and Ionosphere Measurement Sensor(IMS). HEPD has mission to characterize the low altitude high energy particle environment and to study the effects of radiation environment on microelectronics. IMS measures densities and temperature of electrons in the ionosphere and monitors the ionospheric irregularities in KOMPSAT orbit.

Microstructure evolution and effect on deuterium retention in oxide dispersion strengthened tungsten during He+ irradiation

  • Ding, Xiao-Yu;Xu, Qiu;Zhu, Xiao-yong;Luo, Lai-Ma;Huang, Jian-Jun;Yu, Bin;Gao, Xiang;Li, Jian-Gang;Wu, Yu-Cheng
    • Nuclear Engineering and Technology
    • /
    • v.52 no.12
    • /
    • pp.2860-2866
    • /
    • 2020
  • Oxide dispersion-strengthened materials W-1wt%Pr2O3 and W-1wt%La2O3 were synthesized by wet chemical method and spark plasma sintering. The field emission scanning electron microscopy (FE-SEM) analysis, XRD and Vickers microhardness measurements were conducted to characterize the samples. The irradiations were carried out with a 5 keV helium ion beam to fluences up to 5.0 × 1021 ions/m2 under 600 ℃ using the low-energy ion irradiation system. Transmission electron microscopy (TEM) study was performed to investigate the microstructural evolution in W-1wt%Pr2O3 and W-1wt%La2O3. At 1.0 × 1020 He+/m2, the average loops size of the W-1wt%Pr2O3 was 4.3 nm, much lower than W-1wt% La2O3 of 8.5 nm. However, helium bubbles were not observed throughout in both doped W materials. The effects of pre-irradiation with 1.0 × 1021 He+/m2 on trapping of injected deuterium in doped W was studied by thermal desorption spectrometry (TDS) technique using quadrupole mass spectrometer. Compared with the samples without He+ pre-irradiation, deuterium (D) retention of doped W materials increased after He+ irradiation, whose retention was unsaturated at the damage level of 1.0 × 1022D2+/m2. The present results implied that irradiation effect of He+ ions must be taken into account to evaluate the deuterium retention in fusion material applications.