• Title/Summary/Keyword: low radiation

Search Result 2,638, Processing Time 0.033 seconds

p53 Nuclear Accumulation as a Possible Biomarker for Biological Radio-dosimetry in Oral Mucosal Epithelial Cells

  • Kim, Youn-Young;Kim, Jong-il;Kim, Jin;Yook, Jong-In;Kim, The-Hwan;Son, Young-Sook
    • BMB Reports
    • /
    • v.34 no.2
    • /
    • pp.123-129
    • /
    • 2001
  • Cellular response to ionizing radiation is affected by cell types, radiation doses, and post-irradiation time. Based on the trypan blue dye exclusion assay in normal oral mucosal cells (OM cells), a 48 h post-irradiation was sufffcient and an adequate time point for the evaluation of radiation sensitivity Its $LD_{50}$ was approximately 1.83 Gy To investigate possible biomarkers useful for the biological radiodosimetry of normal epithelial cells (p53, c-fos, cyclin D1, cdc-2, pRb) EGF receptor phosphorylation and Erk activation were evaluated at different radiation doses and different post-irradiation times. From 0.5 Gy, p53 was accumulated in the nucleus of basal cells of the OM raft culture at 4 h post-irradiation and sustained up to 24 h post-irradiation, which suggests that radiation-induced apoptosis or damage repair was not yet completed. The number of p53 positive cells and biosynthesis of p53 were correlated with radiation doses. Both cyclin D1 and c-fos were only transiently induced within 1 h post-irradiation. Cyclin D1 was induced at all radiation doses. However, cfos induction was highest at 0.1 Gy, approximately 7.3 fold more induction than the control, whose induction was reduced in a reverse correlation with radiation dose. The phosphorylation pattern of cdc-2 and pRb were unaffected by radiation. In contrast to A431 tails overexpressing the EGF receptor approximately 8.5 fold higher than normal epithelial, the OM cells reduced the basal level of the EGF receptor phosphorylation in a radiation dose dependent fashion. In conclusion, among radiation-induced biomolecules, the p53 nuclear accumulation may be considered for the future development of a useful marker far biological radiodosimetry in normal epithelial tissue since it was sustained for a longer period and showed a dose response relationship. Specific c-fos induction at a low dose may also be an important finding in this study It needs to be studied further for the elucidation of its possible connection with the low dose radio-adaptive response.

  • PDF

A Numerical Analysis on Acoustic Radiation Efficiency of One Side-Wetted Rectangular Mindlin Plate with Simply Supported Boundaries (Mindlin 판 이론을 적용한 단순지지 단면 접수평판의 음향방사효율 수치해석)

  • Lee, Jong-Ho;Cho, Dae-Seung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.55 no.4
    • /
    • pp.281-288
    • /
    • 2018
  • Acoustic radiation efficiency is a crucial factor to estimate Underwater Radiated Noise (URN) of ships accurately. This paper describes a numerical method to analyse acoustic radiation efficiency of one side-wetted rectangular Mindlin plate with simply supported boundaries excited by a harmonic point force. Transverse displacements of plate and acoustic radiation pressures are evaluated by the mode superposition method. The acoustic radiation efficiencies analyzed by both Mindlin and thin plate theories show little differences at monopole and corner modes of low frequency regions but relatively large differences at edge and critical modes of high frequency regions. Especially, the critical frequency with the highest acoustic radiation efficiency evaluated by the Mindlin plate theory is higher than that of thin plate theory. In addition, the acoustic loading effect of fluid also increases bending wave-number of plate and its critical frequency. Finally, the acoustic radiation characteristics of plates with different aspect ratios and thicknesses through numerical analyses are investigated and discussed.

Comparison of Linear Accelerator and Helical Tomotherapy Plans for Glioblastoma Multiforme Patients

  • Koca, Timur;Basaran, Hamit;Sezen, Duygu;Karaca, Sibel;Ors, Yasemin;Arslan, Deniz;Aydin, Aysen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.18
    • /
    • pp.7811-7816
    • /
    • 2014
  • Background: Despite advances in radiotherapy, overall survival of glioblastoma multiforme (GBM) patients is still poor. Moreover dosimetrical analyses with these newer treatment methods are insufficient. The current study is aimed to compare intensity modulated radiation therapy (IMRT) linear accelerator (linac) and helical tomotherapy (HT) treatment plans for patients with prognostic aggressive brain tumors. Material and Methods: A total of 20 GBM patient plans were prospectively evaluated in both linac and HT planning systems. Plans are compared with respect to homogenity index, conformity index and organs at risk (OAR) sparing effects of the treatments. Results: Both treatment plans provided good results that can be applied to GBM patients but it was concluded that if the critical organs with relatively lower dose constraints are closer to the target region, HT for radiotherapeutical application could be preferred. Conclusion: Tomotherapy plans were superior to linear accelerator plans from the aspect of OAR sparing with slightly broader low dose ranges over the healthy tissues. In case a clinic has both of these IMRT systems, employment of HT is recommended based on the observed results and future re-irradiation strategies must be considered.

Study of radiation exposure on human body using of Computed Tomography (전산화단층촬영 검사 시 인체에 미치는 방사선피폭선량 분석연구)

  • Seon, Jong-Ryoul;Yoo, Se-Jong
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.193-198
    • /
    • 2015
  • This study analyzed the total number of 19,636 patients and radiation technologists, 11,433 of male and 8,203 of female by examined body parts, age, types of detectors, the using contrast enhancement and working condition of the technologists, regular staffs or rotation-duty staffs, based on the K-DOS program distributed by FDA with the DLP value of diagnostic evaluation. The result shows that the effective radiation dose was 0.7mSv~41.7mSv for each region and male patients had more radiation exposure than females. And the amount of exposure was also affected by the types and the method of detectors. Furthermore, the regular staffs took the role of helping the patient to get reduced amount of radiation exposure than rotation duty-staffs. Computed tomography (CT) use has increased dramatically over the past several decades. In this reason, to support the patients and the workers' health in the field, the hospitals should apply specialized regular working radiation technologist system and manufacturing companies of those CTs should develop low medical radiation exposure devices.

Characterization of Electron Beam Cured Epoxy Acrylate (에폭시 아크릴레이트의 전자선 영향 평가)

  • Shin, Jin-Wook;Oh, Byung-Hwan;Ko, Keum-Jin;Jeun, Joon Pyo;Kang, Phil Hyun
    • Journal of Radiation Industry
    • /
    • v.4 no.3
    • /
    • pp.271-276
    • /
    • 2010
  • Epoxy resin has wide application in various industrial fields because of their good mechanical strength, superiority adhesion and low shrinkage etc. And the typical curing method for epoxy resins is thermal and press compaction. However, a curing method was used electron beam process in this study. Epoxy acrylate was fabricated from mixture of epoxy, acrylic acid, tetraphenylporphyrin (TPP) and hydroquinone monomethyl ether (MEHQ) with mole ratios. Then electron beam irradiation effect on the curing of the epoxy acrylate resin was investigated various absorption dose in nitrogen atmospheres at room temperature. The dynamic mechanical and thermal properties of the irradiated epoxy acrylate resins were characterized using dynamic mechanical analysis (DMA) and thermogravimetric analyzer (TGA). And the tensile and flexural strength were measured by an universal tensile machine (UTM).

Opportunistic investigation of vascular calcification using 3-dimensional dental imaging

  • Masoud MiriMoghaddam;Hollis Lai;Camila Pacheco-Pereira
    • Imaging Science in Dentistry
    • /
    • v.54 no.3
    • /
    • pp.283-288
    • /
    • 2024
  • Purpose: Given the growing use of cone-beam computed tomography (CBCT) scans, this study assessed radiation exposure from these scans in the context of national guidelines and recommended dose limits. Materials and Methods: The current literature was reviewed to quantify the benefit of opportunistic diagnosis of carotid artery calcification relative to the potential risk of radiation-induced cancer. Results: The average radiation from CBCT at its largest field of view and highest resolution possible amounts to a reasonable but still low ionizing radiation exposure. This exposure is comparable to 22 days of background radiation and is notably lower than the radiation exposure from medical CT scans. According to the risk assessment analysis, the risk of stroke events involving internal and external carotid artery calcification (CAC) was 202 and 67 per 100,000 individuals, respectively. In contrast, the estimated risk of radiation-induced cancer associated with CBCT was notably lower, at 0.6 per 100,000. Conclusion: The present study advocates for a comprehensive assessment of CBCT scans encompassing the areas of the internal and external carotid arteries by a knowledgeable professional, given the potential advantages of early detection of vascular abnormalities. Dental professionals who take scans involving these areas need to be mindful of reporting these findings and refer patients to their primary care physician for further investigation.

FDG PET-CT in Non-small Cell Lung Cancer: Relationship between Primary Tumor FDG Uptake and Extensional or Metastatic Potential

  • Zhu, Shou-Hui;Zhang, Yong;Yu, Yong-Hua;Fu, Zheng;Kong, Lei;Han, Da-Li;Fu, Lei;Yu, Jin-Ming;Li, Jia
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.5
    • /
    • pp.2925-2929
    • /
    • 2013
  • Objective: To explore the relationships between primary tumor $^{18}F$-FDG uptake measured as the SUVmax and local extension, and nodal or distant organ metastasis in patients with NSCLC on pretreatment PET-CT. Methods: 93 patients with NSCLC who underwent $^{18}F$-FDG PET-CT scans before the treatment were included in the study. Primary tumor SUVmax was calculated; clinical stages, presence of local extension, nodal and distant organ metastases were recorded. The patients with SUVmax${\geq}2.5$ were divided into low and high SUVmax groups by using the median SUVmax. The low SUVmax group consisted of 45 patients with SUVmax<10.5, the high SUVmax group consisted of 46 patients with SUVmax${\geq}10.5$. Their data were compared statistically. Results: 91 cases with SUVmax${\geq}2.5$ were included for analysis. The mean SUVmax in patients without any metastasis was $7.42{\pm}2.91$ and this was significantly lower than that ($12.18{\pm}4.94$) in patients with nodal and/or distant organ metastasis (P=0.000). In the low SUV group, 19 patients had local extension, 22 had nodal metastasis, and 9 had distant organ metastasis. In the high SUV group, 31 patients had local extension, 37 had nodal metastasis, and 18 had distant organ metastases. There was a significant difference in local extension (P =0.016), distant organ metastasis (P =0.046), and most significant difference in nodal metastasis rate (P =0.002) between the two groups. In addition, there was a moderate correlation between SUVmax and tumor size (r = 0.642, P<0.001), tumor stage (r = 0.546, P<0.001), node stage (r = 0.388, P<0.001), and overall stage (r = 0.445, P= 0.000). Conclusion: Higher primary tumor SUVmax predicts higher extensional or metastatic potential in patients with NSCLC. Patients with higher SUVmax may need a close follow-up and more reasonable individual treatment because of their higher extensional and metastatic potential.

Prognostic value of neutrophil-to-lymphocyte ratio in locally advanced non-small cell lung cancer treated with concurrent chemoradiotherapy

  • Park, Eun Young;Kim, Yeon-Sil;Choi, Kyu Hye;Song, Jin Ho;Lee, Hyo Chun;Hong, Sook-Hee;Kang, Jin-Hyoung
    • Radiation Oncology Journal
    • /
    • v.37 no.3
    • /
    • pp.166-175
    • /
    • 2019
  • Purpose: This study aimed to investigate neutrophil-to-lymphocyte ratio (NLR) and platelet-to-lymphocyte ratio (PLR) as prognostic factors in patients with locally advanced non-small cell lung cancer (NSCLC) who received concurrent chemoradiotherapy (CCRT). Materials and Methods: We retrospectively analyzed 66 patients with locally advanced NSCLC treated with definitive CCRT. Among these patients, 95% received paclitaxel/carboplatin or docetaxel/cisplatin. The median radiation dose was 66 Gy in 33 fractions. The NLR and PLR before/after CCRT were evaluated. The maximally selected log-rank test was used to obtain the cutoff values related to the overall survival (OS). Results: Patients with high post-CCRT NLR (>3.12) showed worse OS, locoregional progression-free survival (LRPFS), and distant metastasis-free survival (DMFS) than those with low NLR (2-year OS: 25.8% vs. 68.2%, p < 0.001; 2-year LRPFS: 12.9% vs. 33.8%, p = 0.010; 2-year DMFS: 22.6% vs. 38.2%, p = 0.030). Patients with high post-CCRT PLR (>141) showed worse OS and LRPFS than those with low PLR (2-year OS: 37.5% vs. 71.1%, p = 0.004; 2-year LRPFS: 16.5% vs. 40.3%, p = 0.040). Patients with high NLR change (>1.61) showed worse OS and LRPFS than those with low NLR change (2-year OS: 26.0% vs. 59.0%, p < 0.001; 2-year LRPFS: 6.8% vs. 31.8%, p = 0.004). The planning target volume (hazard ration [HR] = 2.05, p = 0.028) and NLR change (HR = 3.17, p = 0.025) were the significant factors for OS in the multivariate analysis. Conclusion: NLR change after CCRT was associated with poor prognosis of survival in patients with locally advanced NSCLC. An elevated NLR after CCRT might be an indicator of an increased treatment failure risk.

Radiation Dose and Image Quality of Low-dose Protocol in Chest CT: Comparison of Standard-dose Protocol (흉부 CT촬영에서 저선량 프로토콜의 선량과 화질: 표준선량 프로토콜과 비교)

  • Lee, Won-Jeong;Ahn, Bong-Seon;Park, Young-Sun
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.84-89
    • /
    • 2012
  • The purpose of this study was to compare radiation dose and image quality between low-dose (LDP) and standard-dose protocol (SDP). LDP (120 kVp, 30 mAs, 2-mm thickness) and SDP (120 kVp, 180 mAs, 1.2-mm thickness) images obtained from 61 subjects were retrospectively evaluated at level of carina bifurcation, using multi-detector CT (Brilliance 16, Philips Medical Systems). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated at ascending aorta and infraspinatus muscle, from CT number and back-ground noise. Radiation dose from two protocols measured at 5-point using acrylic-phantom, and CT number and noise measured at 4-point using water-phantom. All statistical analysis were performed using SPSS 19.0 program. LDP images showed significantly more noise and a significantly lower SNR and CNR than did SDP images at ascending aorta and infraspinatus muscle. Noise, SNR and CNR were significantly correlated with body mass index (p<0.001). Radiation dose, SNR and CNR from phantom were significant differences between two protocols. LDP showed a significant reduction of radiation dose with a significant change in SNR and CNR compared with SDP. Therefore, exposure dose on LDP in clinical applications needs resetting highly more considering image quality.

Verification of the Protective Effect of Functional Shielding Cream for the Prevention of X-ray Low-dose Exposure (X-ray 저선량 피폭방지를 위한 기능성 차폐크림의 방어 효과 검증)

  • Seon-Chil Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.497-506
    • /
    • 2023
  • In the case of radiation workers in medical institutions, radiation exposure is made for patient protection and accurate procedures, so they have a problem of low dose exposure. Low-dose radiation exposure occurs mainly in parts of the body other than the Apron area, and the most frequent place is the skin of the back of the hand. In particular, since the medical personnel's hands require senses and fine movements during the procedure, they are defenseless in the radiation exposure area and are at risk of exposure. It can solve the problem of shielding such as lead gloves, and it is difficult to use by suggesting the activity of the hand during the procedure. To solve this problem, a shielding cream capable of obtaining a functional radiation protection effect was developed and its shielding performance was compared with lead equivalent of 0.1 mmPb. In the process of manufacturing shielding cream, the shielding performance was improved by adding a defoaming process to reduce air holes to increase the density of the cream. Therefore, the shielding cream using barium sulfate as the main material has a lower shielding rate than the lead plate, and in the realm of effective energy, it is 59%, At high effective energy, a difference of about 37% was shown, indicating that there is a functional radiation protection effect. The advantage is that it can be used directly on the skin, and it is considered that it can be used before wearing surgical gloves and has a permanent protective effect.