• 제목/요약/키워드: low radiation

검색결과 2,581건 처리시간 0.025초

Neutron Dosimetry and Monitoring in the Radiation Environment

  • Nakamura, Takashi
    • Journal of Radiation Protection and Research
    • /
    • 제14권2호
    • /
    • pp.51-62
    • /
    • 1989
  • The high efficiency moderated-type neutron spectrometer and doseequivalent counter were developed for the measurement of low level environmental neutrons. By using these detectors, the neutron energy spectra and dose equivalent rates due to skyshine effect were measured in the environment surrounding the accelerator facilities and also the altitude variation of cosmic ray neutrons in the aircraft flying over Japan.

  • PDF

The Acceleration of Germination in Welsh Onion Seed Irradiated with the Low Dose ${\gamma}-ray$ Radiation (저선량 감마선 조사가 파종자의 발아에 비치는 영향)

  • Lee, Eun-Kyung;Kim, Jae-Sung;Lee, Young-Keun;Lee, Young-Bok
    • Korean Journal of Environmental Agriculture
    • /
    • 제17권4호
    • /
    • pp.346-351
    • /
    • 1998
  • To investigate the hormetic effects of the low dose ${\gamma}-ray$ radiation on the germination rate, Welsh onion (Allium fistulosum L. cv. Eunchun and cv. Sukchangwoidae) seeds were irradiated at the dose of $0.5\;{\sim}24.0$ Gy with the ${\gamma}-ray$ radiation (Co-60). The germination rate of 'Eunchun' cultivar increased about 10% in the low dose ${\gamma}-ray$ irradiation group compared with that of the control. In the 'Sukchangwoidae' cultivar, the germination rate of the 4 Gy irradiation group increased 40% more than that of the control. Broadly, it seemed that the hormetic effects of the low-dose ${\gamma}-ray$ radiation were taken more promisingly in the uncultivated soil than in the fertile soil. The germination rate from the paper towel and filter paper based cultivation increased 10% and 16% more, respectively, in the 1 Gy irradiation group than that in the control group. And the electric conductivities of the above groups supposed to be taken hormetic effects of the ${\gamma}-ray$ radiation were lower than those of the control group. From the above results, it is suggested that the low dose ${\gamma}-ray$ radiation ranged from 1 Gy to 10 Gy could have the hormetic effects on the germination rate related characters in Welsh onion seeds.

  • PDF

Effects of Low Dose $\gamma$-Radiation on the Growth, Activities of Enzymes and Photosynthetic Activities of Gourd (Lagenaria siceraria) (저선량 $\gamma$선 조사가 참박의 초기 생육과 효소 활성 및 광합성 능에 미치는 영향)

  • 이혜연;김재성;백명화;이영근;임돈순
    • Korean Journal of Environmental Biology
    • /
    • 제20권3호
    • /
    • pp.197-204
    • /
    • 2002
  • Gourd seeds were irradiated with the doses of 0-20 Gy to investigate the effect of the low dose $\gamma$-radiation on the early growth and physiological activity. The stimulating effects of the low dose y- radiation on the early growth were not noticeably high, but were increased generally at 4-16 Gy irradiation group. The catalase and peroxidase activity of cotyledon from seeds irradiated with $\gamma$- radiation were increased at 8 Gy irradiation group. The photochemical activity of leaf was noticeably high at 4 Gy irradiation group. The photochemical yield of PSII, estimated as Fv/Fm, decreased with increasing illumination time by 50% after 4 hrs in the control and 8 Gy irradiation group, while Fo slightly increased. However, Fv/Em in the 4 Gy irradiation group decreased by 40% of inhibition, indicating that photoinhibition decreased by the low dose $\gamma$- radiation. Changes in the effective quantum yield of PSII, $\varphi_{PSII}$ and 1/Fo- l/Fm, a measure of the rate constant of excitation trapping by the PSII reaction center, showed similar pattern to Fv/Em. NPQ decreased by 70% after photoinhibitory treatment with showing similar pattern between the control and the irradiation group. These results showed the positive effect of low dose $\gamma$- radiation on the seedling growth and the reduction of photoinhibition in the 4 Gy irradiation group.

Determination of Consistency according to the Status of Supplementary Education for Radiation Safety Management Managers (방사선안전관리책임자 보수교육의 현황에 따른 정합성 판단)

  • Seung-Chul Kim
    • Journal of radiological science and technology
    • /
    • 제47권1호
    • /
    • pp.7-12
    • /
    • 2024
  • Medical institutions wishing to install and operate diagnostic radiation generators must complete appointment training within one year of appointment based on the 「Medical Act」 and the 「Rules on Safety Management of Diagnostic Radiation Generator Devices」 which will come into effect on January 1, 2024. Additionally, You must receive supplementary education every three years from the date you received it. The strengthening of safety management for diagnostic radiation generators used in medical institutions means that although the radiation exposure that may occur when using diagnostic radiation generators is low, the risk of carcinogenesis may be higher than previously evaluated. In addition, safety management of diagnostic radiation generators can be said to be an essential requirement because it has been reported that the incidence of leukemia and other diseases is increasing in diagnostic radiation tests. However, the safety management training targets and programs for radiation exposure management operated by other organizations other than diagnostic radiation generators are significantly different. In addition, since the public institutions that are responsible for radiation safety management are divided, there is a risk of duplicative, excessive, and under-administrative application to medical institutions and educational institutions that install and operate diagnostic radiation generators. Therefore, we would like to determine their consistency by comparing domestic and foreign related cases and the provisions of the 「Medical Act」 and the 「Nuclear Safety Act」.

Reduction of Radiated Noise by Eigen-property Control (구조물의 고유특성 제어를 통한 방사 소음 저감)

  • 최성훈
    • The Journal of the Acoustical Society of Korea
    • /
    • 제23권5호
    • /
    • pp.376-382
    • /
    • 2004
  • The interaction between a vibrating structure and a surrounding acoustic medium determines the acoustic power propagating into the far-field. A straightforward method to reduce the radiated power is to reduce the vibration of the structure. However it is more efficient to control the modes of the structure separately since each vibration mode of the structure has different radiation efficiency. An efficient method to reduce the sound radiation in the low frequency region is proposed by reducing the radiation efficiency of the structure. Numerical simulations are carried out for a simply-supported beam in which the feed-forward control is applied to reduce the volume velocity of each structural mode. This method is found to be very efficient in reducing low frequency sound radiation.

A Theoretical Consideration about Effects of Radiation on the Physical Properties of PP (PP 재질의 물성에 미치는 방사선의 영향에 대한 이론적 고찰)

  • 김문수;강덕원;엄희문
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 한국방사성폐기물학회 2003년도 가을 학술논문집
    • /
    • pp.517-523
    • /
    • 2003
  • The physical properties of polypropylene (PP) membranes under the radiation field were investigated. To calculate radiation flux affecting to PP, it was used MCNP4A Code. The PP membrane and deoxygenation equipment were standardized to bar structure in order to calculate the phonton flux with MCNP4A Code. The change in the properties of the PP membrane to be used in deoxygenation equipment was rarely occurred during the usage work because the radiation level of reactor coolant water was very low level and The doses of radiation workers are very low. From the results, it was found that the Physical properties of PP membranes which used for nuclear power plant reactor coolant water disposal were not rarely changed under the simulated radiation field.

  • PDF

Preliminary Results of Tissue-Equivalent Proportional Counter (TEPC) Dosimeter for Measuring In-Situ Aviation Radiation

  • Nam, Uk-won;Park, Won-kee;Hwang, Junga;Sohn, Jongdae;Moon, Bongkon;Kim, Sunghwan
    • Journal of Astronomy and Space Sciences
    • /
    • 제37권4호
    • /
    • pp.249-255
    • /
    • 2020
  • We develop the tissue-equivalent proportional counter (TEPC) type's space radiation dosimeter to measure in-situ aviation radiation. That was originally developed as a payload of small satellite in the low-earth orbit. This dosimeter is based on a TEPC. It is made of an A-150 tissue-equivalent plastic shell of an internal diameter of 6 cm and a thickness of 0.3 cm. TEPC is filled with pure propane at 13.9 torrs to simulate a cell diameter of 2 ㎛. And the associated portable and low power electronics are also implemented. The verification experiments have been performed by the calibration experiments at ground level and compared with Liulin observation at aircraft altitude during the flight between Incheon airport (ICN) and John F. Kennedy airport (JFK). We found that the TEPC dosimeter can be used as a monitor for space radiation dosimeter at aviation altitude based on the verification with Liulin observation.

Low-Dose Abdominal CT for Evaluating Suspected Appendicitis in Adolescents and Young Adults: Review of Evidence

  • Ji Hoon Park;Paulina Salminen;Penampai Tannaphai;Kyoung Ho Lee
    • Korean Journal of Radiology
    • /
    • 제23권5호
    • /
    • pp.517-528
    • /
    • 2022
  • Due to its excellent diagnostic performance, CT is the mainstay of diagnostic test in adults with suspected acute appendicitis in many countries. Although debatable, extensive epidemiological studies have suggested that CT radiation is carcinogenic, at least in children and adolescents. Setting aside the debate over the carcinogenic risk of CT radiation, the value of judicious use of CT radiation cannot be overstated for the diagnosis of appendicitis, considering that appendicitis is a very common disease, and that the vast majority of patients with suspected acute appendicitis are adolescents and young adults with average life expectancies. Given the accumulated evidence justifying the use of low-dose CT (LDCT) of only 2 mSv, there is no reasonable basis to insist on using radiation dose of multi-purpose abdominal CT for the diagnosis of appendicitis, particularly in adolescents and young adults. Published data strongly suggest that LDCT is comparable to conventional dose CT in terms of clinical outcomes and diagnostic performance. In this narrative review, we will discuss such evidence for reducing CT radiation in adolescents and young adults with suspected appendicitis.