• Title/Summary/Keyword: low permeability

Search Result 886, Processing Time 0.026 seconds

An Experimental Study on the Permeability Measurement and Development of Ultra Low Permeable Concrete (콘크리트의 투수성 측정 및 초저투수성 콘크리트의 개발 연구)

  • 오병환;정원기;차수원;장봉석
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.5
    • /
    • pp.189-200
    • /
    • 1996
  • The permeability of concrete influences the durability of concrete remarkably. The conventional test method for permeability is very difficult to apply to high strength concrete because of its very low permeability. The present study employs a resonable and realistic test method for permeability of concrete and proposes a very low permeability concrete. To this end, comprehensive tests have been conducted and major test variables include the types and amount of cement. the types and amount of admixtures, and the size of aggregates. The present test results indicate t h a t the permeability decrease with the increase of strength and that the concrete with certain mineral admixtures exhibits very low permeability. The permeability of those high performance concrete is about 1/100 of conventional normal concrete. The present study provides a firm base for the use of very low permeable and hence very durable concrete.

Forward and Back Diffusion from Low Permeability Zone: A Review of Analytical Solutions with Different Boundary Conditions (저투수성 매체 내 오염물질의 정확산과 역확산: 경계조건에 따른 용질이동 해석해의 소개)

  • Kim, Changmin;Yang, Minjune
    • Economic and Environmental Geology
    • /
    • v.53 no.1
    • /
    • pp.99-110
    • /
    • 2020
  • It is a global trend to consider contaminated low-permeability zones as one of the primary management targets for the remediation of DNAPL contaminated sites. In addition, studies on the persistence caused by back diffusion of DNAPLs from low-permeability zones have been actively conducted worldwide. On the other hand, the studies for domestic groundwater contamination with the low-permeability zones are insufficient. Therefore, this study introduces the forward and back diffusions of DNAPL through low-permeability zones and suggests the importance of them by reviewing representative previous studies, especially on back diffusion and plume persistence. We proposed six diffusion scenarios and analytical solutions based on various boundary conditions of low-permeability zones. FI (forward diffusion into infinite domain) and BI (back diffusion form infinite domain) scenarios illustrate forward and back diffusion in which the depths of a low-permeability layer are assumed to be infinite. FFN (forward diffusion into finite domain with no flux boundary) and BFN (back diffusion from finite domain with no flux boundary) scenarios describe forward and back diffusion for a finite domain of a low-permeability layer with no flux boundary at the bottom. When the bottom of a low-permeability layer is considered as flux boundary, forward and back diffusion scenarios correspond to FFF (forward diffusion into finite domain with flux boundary) and BFF (back diffusion from finite domain with flux boundary). The scenarios and analytical solutions in this study may contribute to the determination of an efficient remediation method based on site characteristics such as a thickness of low-permeability zones or duration of contamination exposure.

Characteristics of waterflood at low rate in low permeability sandstones based on the CT scanning

  • Mo, S.Y.;Lei, Q.;Lei, G.;Gai, S.H.;Liu, Z.K.
    • Geosystem Engineering
    • /
    • v.21 no.6
    • /
    • pp.344-351
    • /
    • 2018
  • It is reported that the flooding rate in low permeability sandstones is low and the oil recovery is hard to increase after water breakthrough. Understanding characteristics of waterflood is hence important for the recovery improvement. In this work, flooding tests on low permeability sandstones were conducted. The corresponding flooding characteristics were investigated by means of CT scanning and Nuclear Magnetic Resonance. Effects of irreducible water and different rates were also discussed in detail. Experimental results reveal a piston-like displacement at a low rate in low permeability samples. The saturation profile is steep and almost vertical to the forward direction. The results at a low rate confirm that once water broke through, increasing the flooding rate or flooding time can hardly reduce the remaining oil inside the sample. It is probably due to the high pore-throat ratio proven by rate-controlled mercury. Results also confirm that the presence of initial water enhanced sweep efficiency substantially. On one hand, because water had previously occupied the small pores, the subsequent oil can only invade relatively large pores and became more movable. On the other hand, stable collars can not form due to the steep front, which may suppress the snap-off.

One-dimensional Analytical Solutions for Diffusion from a Low-permeability Layer (1차원 해석해를 이용한 저투수성 매체에서의 확산에 관한 연구)

  • Jang, Seonggan;Yang, Minjune
    • Economic and Environmental Geology
    • /
    • v.53 no.1
    • /
    • pp.11-21
    • /
    • 2020
  • One-dimensional analytical solutions were used for forward and back diffusion of trichloroethylene (TCE) and tetrachloroethylene (PCE) in a single system with high- and low-permeability layers. Concentration profiles in a low-permeability layer, diffusive fluxes at the interface between the high- and low-permeability layers, and contaminant persistence in the high-permeability layer due to back diffusion were simulated with a comparison of semi-infinite and finite analytical solutions. In order to validate the analytical solutions used in this study, the results of one-dimensional analytical solutions developed by Yang et al. (2015) were compared with Nash-Sutcliffe model efficiency coefficient (NSE). When compared with Yang et al. (2015), the analytical solutions used in this study showed good agreements (NSE = 0.99). When compared with semi-infinite analytical solutions, TCE and PCE concentration profiles in the low-permeability layer, the diffusive fluxes, and the contaminant tailings of the high-permeability layer were underestimated. In order to determine the appropriate analytical solutions based on the effective diffusion coefficient, the thickness of the low-permeability layer, and the diffusion time in the TCE and PCE contaminated site, a term of dimensionless diffusion length (Zd) was used. If the Zd is less than 0.7, the semi-infinite solutions can be used to simulate accurate concentration profiles in low-permeability layers. If the Zd is greater than 0.7, the reliability of simulations may be improved by using the finite solutions.

Effect of Surface Finishing Materials on the Moisture Conditions in Concrete: Vapor and Water Permeability of Finishing Materials Under Changing Environmental Conditions

  • Ryu, Dong-Woo
    • International Journal of Concrete Structures and Materials
    • /
    • v.2 no.2
    • /
    • pp.83-90
    • /
    • 2008
  • Permeability to vapor and water among other performances required for finishing materials is dealt with in this study. The relative moisture content of concrete coated/covered with a finishing material was experimentally investigated while changing the environmental conditions including temperature, relative humidity, and rainfall. An organic paint (water-based urethane), organic synthetic resin emulsion-type film coating (film coating E), and inorganic porcelain tiles were selected as the finishing materials. When compared from the aspect of vapor and water permeability, the vapor permeability and water permeability of water-based urethane were high and low, respectively; those of film coating E were high and high, respectively; and those of porcelain tiles were low and low, respectively. This means that the moisture state of concrete structures is governed not only by the environmental conditions but also by the performance of finishing materials. It is therefore of paramount importance to appropriately select a finishing material to address the specific deteriorative factors involved in the concrete structure to be finished.

The Permeability Characteristics of the Reactive Soil - Bentonite Landfill Liner (혼합반응 차수재의 투수특성 연구)

  • 이강원;황의석;안기봉;정하익;김학문
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.545-552
    • /
    • 2002
  • The purpose of this paper is to investigate permeability characteristic of soil-bentonite landfill liner and development of desirable liner system. In this study, permeability tests for soil-bentonite, reactive soil-bentonite and apply bentomat and reactive mat are carried out under the low and high water pressure. According to test result, additional amount of bentonite decreases the coefficient of permeability up to the bentonite mixture ratio of 15%. Therefore, the permeability test for landfill liner's indicated that the use of general water would be in more safe side because the liner system show low permeability duet decrease effect of porous by suspended soild(SS). The permeability of leachate for Zeolite mixture ratio 0, 5, 10% with bentonite mixture ratio 15% showed negligible variation in the permeability with general water. Therefore, Zeolite could be used as a successful that is available purification material for the treatment of leachate, without changing the of landfill liners. Also odious smell could be removed by adding smell amount of Zeolite to the leachate. It was revealed that the bentomat and reactive mat installed in soil-bentonite layer effectively improved the permeability as well as purification of the leachate.

  • PDF

Effect of Fabric Structural Parameters and Surface Finishing Characteristics to Water Repellency/Proofing/Vapor Permeability of Breathable Fabrics for Sportswear Clothing (직물 구조인자와 표면 가공특성이 스포츠 의류용 투습직물의 발수/방수/투습특성에 미치는 영향)

  • Kim, Hyun Ah
    • The Korean Fashion and Textile Research Journal
    • /
    • v.22 no.1
    • /
    • pp.112-118
    • /
    • 2020
  • This paper examined the water repellency, water proofing and water vapor permeability of twelve types of woven fabrics for sports wear clothing. Their physical properties were compared and discussed with the fabric structural parameters and surface finishing effect. A water repellent property of 100% was obtained in the coated or laminated water repellent finished fabrics; in addition, cotton/nylon breathable composite fabrics treated with a laminated finishing and with low fabric density showed a 90% water repellency. Water proofing fabric above 6,000 mm H2O hydraulic pressure was achieved by coated or laminated finishing; however, high density fabric or medium-level coated fabrics exhibited 100% water repellent and low water proofing characteristics. Superior water vapor permeability characteristics with good water repellency and proofing properties were achieved at the 2.5 layered low density and with 0.7 - 0.9 cover factor nylon fabrics treated with hydrophilic laminated finishing. The regression analysis for examining the effects of fabric structural parameters and surface finishing such as coating and laminating to the water vapor permeability exhibited a high determination coefficient of fabric structural parameters of 63.5%; in addition,, main factors among fabric structural parameters appeared to be cover factor and fabric thickness per weight. Coating and Laminating factors exhibited determination coefficient of water vapor permeability parameters of 36.5%.

Fabrication of Low Density Sintered Stainless Steel Filter

  • Seok, Se-Hoon;Park, Dong-Kyu;Jung, Kwang-Chul
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.611-612
    • /
    • 2006
  • In a manufacturing technique of the sintered filter, pressureless sintering method has good permeability, it is not need the binder and lubricant used on compacting process, so it has little contamination and it is easy to control the pore size and shape but the mechanical strength is low relatively and it is difficult that parts of complicate form are manufactured. In the case of manufacturing the filter by press and sintering method, in order to be satisfactory characteristic of un-pressed filter, in this study sintered metal filter fabricated by using 30-40mesh stainless steel 316L powder and additive agents. Porosity and structure of pores, permeability and mechanical strength of the sintered filter were investigated with the variation sintering conditions. Porosity was nearly constant about $60{\sim}70%$, density, permeability and mechanical strength were changed markedly with quantity of additive materials and sintering conditions.

  • PDF

Chloride Permeability of High Strength Concrete (고강도 콘크리트의 염화물 침투특성)

  • ;;;Kawano, Hirotaka
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.985-990
    • /
    • 2001
  • Chloride permeability of high strength concrete(HSC) was investigated using saltwater pending test and rapid chloride permeability test by electrical potential(ASTM C 1202). The lower water-cement ratio concrete showed the lower diffusion coefficient of chloride. The relationship between the diffusion coefficient of chloride and charge passed by the rapid chloride permeability test could be obtained. This relationship appears to be an effective method for evaluating chloride permeability of low water-cement HSC.

  • PDF

A Experimental study for obtaining material function of very soft clay (초연약 점토의 구성관계 산정에 관한 실험적 연구)

  • Lee, Song;Kang, Myung-Chan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.491-498
    • /
    • 2002
  • Dredged and reclaimed soft clays form slurry state which is very high water content and very low shear strength, experience large self-weight consolidation, nonlinear compressibility and permeability phenomenon would take place. In this case, a material functions which represent variety effective stress-void ratio-permeability relation (especially very low effective stress), are should be determined to predict nonlinear finite strain consolidation phenomenon forehand In this study, large slurry consolidometer with a 380mm diameter and a 1400mm height which is able to consolidation and permeability test, was developed to determine material function of very soft clay with a 500% initial water content clay, self-weight consolidation and low stress level consolidation (1Kpa, 3Kpa, 6Kpa, 12Kpa) was conducted and after each consolidation step permeability test also conducted. after final consolidation step, a constant rate of strain consolidation was conducted with undisturbed sample obtained from the large consolidometer. On the above result, material function was determined and laboratory test was modelled to evaluate its validity, numerical analysis on th field was compared to other method.

  • PDF