• 제목/요약/키워드: low magnetic field measurement

검색결과 79건 처리시간 0.026초

Survey on Magnetic Field around Substations and Proposals to Broaden Understanding of the Magnetic Field Characteristics (변전소 주변 자계 실태조사 및 자계 특성이 이해증진 방안)

  • Rhee, Seong-Su;Shin, Heon-Shik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제20권6호
    • /
    • pp.526-534
    • /
    • 2009
  • The magnetic field of the extremely low frequency that occurs in the substation facilities was surveyed to present ways to broaden understanding of the magnetic field characteristics. We have investigated the level of the magnetic fields in the substation areas and control rooms of 25 substations in the metropolitan area in accordance with the measurement method of IEC CISPR(IEC/TC106 PT 62110). We propose objective and reliable policy approaches such as the electromagnetic field certification system to more accurately understand the property of magnetic field.

Speed measurement algorithm for low-resolution magnetic encoder of industrial electric vehicle (산업용 전기 차량의 저 분해능 마그네틱 엔코더를 사용한 속도 측정 방법)

  • Park, Gi-Hyoung;Jeong, Se-Jong
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.312-313
    • /
    • 2011
  • Recently, many industrial electric vehicles have been developed using various ac-motor drive technologies including field oriented vector control. Generally, a magnetic encoder is installed to have resistance to vibration and dust, and it is cost-effective. However, it is difficult to get an accurate rotor speed for high performance of vector control, because a resolution of the magnetic encoder is low and its phase accuracy is poor. In order to overcome this hardware problem, this study proposes a speed measurement algorithm using moving window for low-resolution magnetic encoder. This algorithm is experimentally tested and successfully applied to traction application of industrial electric vehicle.

  • PDF

Speed measurement algorithm for low-resolution magnetic encoder of industrial electric vehicle (산업용 전기 차량의 저 분해능 마그네틱 엔코더를 사용한 속도 측정 방법)

  • Park, Gi-Hyoung;Jeong, Se-Jong
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.316-317
    • /
    • 2011
  • Recently, many industrial electric vehicles have been developed using various ac-motor drive technologies including field oriented vector control. Generally, a magnetic encoder is installed to have resistance to vibration and dust, and it is cost-effective. However, it is difficult to get an accurate rotor speed for high performance of vector control, because a resolution of the magnetic encoder is low and its phase accuracy is poor. In order to overcome this hardware problem, this study proposes a speed measurement algorithm using moving window for low-resolution magnetic encoder. This algorithm is experimentally tested and successfully applied to traction application of industrial electric vehicle.

  • PDF

Selective detection of AC transport current distributions in GdBCO coated conductors using low temperature scanning Hall probe microscopy

  • Kim, Chan;Kim, Mu Young;Park, Hee Yeon;Ri, Hyeong-Ceoul
    • Progress in Superconductivity and Cryogenics
    • /
    • 제19권1호
    • /
    • pp.26-29
    • /
    • 2017
  • We studied the distribution of the current density and its magnetic-field dependence in GdBCO coated conductors with AC bias currents using low temperature scanning Hall probe microscopy. We selectively measured magnetic field profiles from AC signal obtained by Lock-in technique and calculated current distributions by inversion calculation. In order to confirm the AC measurement results, we applied DC current corresponding to RMS value of AC current and compared distribution of AC and DC transport current. We carried out the same measurements at various external DC magnetic fields, and investigated field dependence of AC current distribution. We notice that the AC current distribution unaffected by external magnetic fields and preserved their own path on the contrary to DC current.

Characteristics of Time Varying Magnetic Fields in Thyristor Rectifiers of 19kA in Chlor-Alkali Industry

  • Shirmohammadi, Siamak;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.383-384
    • /
    • 2014
  • This paper investigates the experimental and simulated time-varying magnetic field generation in a chlor-alkali manufacturing process. 19kA thyristor-based rectifier is modeled and analyzed. The performance is compared and evaluated on the basis of exposure guidelines from ICNIRP. The mechanical structure of current carrying conductor is simplified as an infinite long busbar model and low frequency harmonic contents up to 65kHz are considered. Thyristor rectifier generates a significant amount of low frequency magnetic field harmonic contents both at ac and dc busbar of rectifier infringing the limit of ICNIRP. Along with simulation analysis the experimental measurement of the time-varying magnetic field in ac input busbar, rectifier block, dc load and busbar are presented. The experimental test results partly confirm the simulation results.

  • PDF

Analysis and measurement of low frequency magnetic field according to internal position of electric railway train (전기철도차량 객실 내부 위치에 따른 극저주파 자계 측정 및 분석)

  • Jang, Dong-Uk;Han, Moon-Seob
    • Proceedings of the KSR Conference
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.489-494
    • /
    • 2008
  • The measurement of magnetic field is performed about DC and AC magnetic field in electric railway line. The test point is cap, on the converter/inverter box, on the traction motor and on the SIV, the height of measurement is bottom and 60 cm height. In case of AC magnetic field, the selected specific frequency is measured on the converter/inverter box. The AC magnetic field is checked and analysis through BNC output, DAQ cad and notebook PC.

  • PDF

Construction of AC-DC Magnetic Field Standard Systems and Results of International Key Comparison (직류-교류 자기장 표준 시스템 제작 및 국제비교 결과)

  • Park, Po-Gyu;Kim, Young-Gyun
    • Journal of the Korean Magnetics Society
    • /
    • 제14권6호
    • /
    • pp.201-206
    • /
    • 2004
  • The AC-DC magnetic field standard systems were constructed for the calibration of magnetometers for low magnetic field and the tests for low magnetic field characteristics of sensors and materials. In the range of 1 mT, the expanded uncertainty of dc is 8${\times}$10$\^$-6/, ac uncertainties are 0.16% in 0.1~1 kHz, 0.26% in 1~5 kHz, and 0.44% in 5~20 kHz. We have been participated in international key comparison(KC) to achieve the equality and the mutual agreement between standard institutes for the results of calibrations and tests. KRISS participating in ac-dc magnetic flux density of KC got equal level of uncertainty results compare with the advanced nations. It confirm that measurement ability of magnetic flux density is high level in the world.

Construction of Differential Type Search Coil Magnetometer (차동형 탐지코일 마그네토미터 제작)

  • Kim, J.H.;Son, De-Rac
    • Journal of the Korean Magnetics Society
    • /
    • 제20권5호
    • /
    • pp.178-181
    • /
    • 2010
  • Search coil magnetometer has been used for detection of ac magnetic field with high sensitivity. To reduce demagnetizing factor of core and increase S/N ratio of search coil magnetometer, the core was divided by two parts and coil was wound on each cores. Two coils were connected serially and put into amplifier as differential mode. Constructed 120 mm length search coil magnetometer shows linearity of 0.03%, sensitivity of 9.3 mV/nT, and resolution of 20 pT at 1 Hz.

Development and Construction of low Magnetic Field Control System for Analysis of Magnetic Field Effect in the Deflection Yoke (브라운관의 자기장 영향 분석용 저자기장 제어 장치의 설계 및 제작)

  • Park, Po-Gyu;Kim, Young-Gyun;Shin, Suk-Woo;Choi, Hyung-Ho;Kim, Tae-Ik;Jung, Dong-Keun
    • Journal of the Korean Magnetics Society
    • /
    • 제13권6호
    • /
    • pp.251-256
    • /
    • 2003
  • We have developed the quality analysis system for magnetic field effect of cathode-ray tube that is used a monitor, TV and medical appliance. We designed and constructed the large 3-axis square coil (2 m length) system for the generation of 3-component magnetic field using power supply, magnetometer and computer below 0.2 mT range. The coil constant is 30.31 ${\mu}$T, 29.73 ${\mu}$T and 30.51 ${\mu}$T for the X, Y and Z axis square coil respectively. The magnetic field resolution was 0.01 T. The uniformity of magnetic field was measured within 1 % in the range of 12 cm.