• 제목/요약/키워드: low load

검색결과 3,884건 처리시간 0.043초

마이크로히터에서 반주기 정현곡선의 열부하에 의한 비정상 열전달 연구 (NUMERICAL STUDY OF UNSTEADY HEAT TRANSFER ON MICRO HEATER UNDER HALF-CYCLE SINUSOIDAL HEAT LOAD)

  • 김명준;이희준
    • 한국전산유체공학회지
    • /
    • 제19권4호
    • /
    • pp.1-7
    • /
    • 2014
  • A numerical study of transient conjugate heat transfer on micro heater in a micro-channel substrate under a sinusoidal heat load was conducted. It was found that the time constant is not affected by the maximum heating magnitude of the sinusoidal heat load. However, the time constant increases with low duration of the sinusoidal heating period and low Reynolds number. Moreover, there is a threshold where a heater temperature do not reach to time constant at low thermal diffusivity, low flow rate, and low pulse duration of the sinusoidal heating. The time constant should be considered for transient convective heat transfer under transient sinusoidal heat load in a micro heat sink.

An Adaptive Energy-Efficient and Low-Latency MAC Protocol for Wireless Sensor Networks

  • Liu, Hao;Yao, Guoliang;Wu, Jianhui;Shi, Longxing
    • Journal of Communications and Networks
    • /
    • 제12권5호
    • /
    • pp.510-517
    • /
    • 2010
  • In this paper, an adaptive MAC protocol (variable load adaptive (VLA)-MAC) is proposed for wireless sensor networks. This protocol can achieve high energy efficiency and provide low latency under variable-traffic-load conditions. In the case of VLA-MAC, traffic load is measured online and used for adaptive adjustment. Sensor nodes transmit packets in bursts under high load conditions to alleviate packet accumulation and reduce latency. This also removes unnecessary listen action and decreases energy consumption in low load conditions. Simulation results show that the energy efficiency, latency, and throughput achieved by VLA-MAC are higher than those achieved by some traditional approaches.

A New Adaptive Load Sharing Mechanism in Homogeneous Distributed Systems Using Genetic Algorithm

  • Lee Seong-Hoon
    • International Journal of Contents
    • /
    • 제2권1호
    • /
    • pp.39-44
    • /
    • 2006
  • Load sharing is a critical resource in computer system. In sender-initiated load sharing algorithms, the sender continues to send unnecessary request messages for load transfer until a receiver is found while the system load is heavy. Meanwhile, in the receiver initiated load sharing algorithms, the receiver continues to send an unnecessary request message for load acquisition until a sender is found while the system load is light. These unnecessary request messages result in inefficient communications, low CPU utilization, and low system throughput in distributed systems. To solve these problems, we propose a genetic algorithm based approach for improved sender-initiated and receiver-initiated load sharing in distributed systems. And we expand this algorithm to an adaptive load sharing algorithm. Compared with the conventional sender-initiated and receiver-initiated algorithms, the proposed algorithm decreases the response time and task processing time.

  • PDF

작업기억 부담이 부적 얼굴정서 처리에 미치는 영향: ERP 연구 (Effects of Working Memory Load on Negative Facial Emotion Processing: an ERP study)

  • 박태진;김정희
    • 인지과학
    • /
    • 제29권1호
    • /
    • pp.39-59
    • /
    • 2018
  • 작업기억 부담이 부적 얼굴정서 처리에 미치는 영향을 밝히기 위해, N-back 과제 수행 도중 제시된 부적 얼굴표정에 의해 유발된 ERP성분들을 조사하였다. 한 개씩 순차적으로 제시되는 시각적 사물그림들에 대한 기억을 유지하고 갱신하도록 요구하면서(N-back 과제) 이 사물그림들이 제시되는 사이에 공포표정 또는 중립표정의 얼굴자극을 하나씩 제시하였는데, 작업기억 부담을 0-back 조건(저부담)과 2-back 조건(고부담)으로 조작하였다. N-back과제 수행반응을 분석한 결과, 고부담조건에 비해 저부담조건에서 더 빠르고 정확한 반응이 관찰되었다. 얼굴자극에 의해 유발된 ERP 평균진폭을 분석한 결과, 후두영역에서 측정한 P1 진폭에서는 정서가효과는 유의미하지 않았고 작업기억 부담효과만 유의미하였다(고부담 > 저부담). 후측 후두-측두 영역에서 측정한 N170 진폭에서 얼굴 정서가효과는 전반적으로는 유의미하였지만(부정 > 중립) 세부적으로는 작업기억부담과 반구에 따라 다르게 나타났는데, 정서가효과가 좌반구에서는 저부담조건의 경우에만, 우반구에서는 두 부담조건 모두에서 관찰되었다. 결국, 얼굴표정의 부적 정서가가 N170에 미치는 영향이 좌반구에서는 작업기억 부담에 의해 조절되었지만 우반구에서는 그렇지 않았다. 이러한 결과는, 부적 얼굴 표정의 초기 정서처리가 작업기억의 유지 및 조작 부담이 큰 경우 좌반구에서는 약화되거나 일어나지 않을 수 있는 반면, 우반구에서는 작업기억 부담의 크기에 관계없이 일어남을 보여주는 것으로써, 부적 얼굴정서 처리의 우반구 편재를 시사한다.

PWM 방식과 인버터 방식의 압축기를 사용한 시스템 에어컨의 성능평가에 대한 실험적 연구(냉난방 특성) (Experimental Study on Performance Evaluation of System Air-Conditioner using Compressor of PWM or Inverter Method (Cooling and Heating Characteristics))

  • 전용호;김대훈;허삼행;권영철;문제명;홍주태
    • 설비공학논문집
    • /
    • 제15권9호
    • /
    • pp.738-743
    • /
    • 2003
  • In the present study, the heating and cooling characteristics of system air-conditioner using a PWM compressor or a BLDC inverter compressor are investigated by the psychometric calorimeter using air enthalpy method. Cooling and heating capacities, power inputs and COPs are measured at the low, moderate, high loads under the cooling and heating standard conditions. At cooling conditions, the capacity of the PWM system is larger than that of the inverter case. Due to large power input, however, low COPs are measured under total load ranges. At heating conditions, the capacity of the PWM method is a little larger than that of the inverter case, except high load range. Since power input is low, large COPs are measured at moderate and high load ranges, which are different from cooling data. This shows that the PW system compared with the inverter case has good energy consumption efficiency at moderate and high load ranges except low load range. And when the system A/C is operated under the cooling and heating standard conditions, COPs are nearly uniform at total load ranges.

수동형 필터 적용시 무효전력의 변화에 관한 연구 (Study on the Variation of Reactive Power When Applying the Passive Filter)

  • 김지명;김종겸
    • 전기학회논문지
    • /
    • 제65권9호
    • /
    • pp.1626-1631
    • /
    • 2016
  • Generally, the low-voltage customer has been used with a linear load and nonlinear load in the 3-phase 4-wire distribution system. Linear load has usually configured the resistance and inductance, current phase is slower than the voltage phase, so power factor is low. It is required for the power factor correction device prior to the phase of the current than the voltage. The capacitor is connected in parallel to the load in order to ensure a low power factor. Power converter such as an inverter is a typical non-linear load. Non-linear load generates harmonic currents in the energy conversion process. Many electrical equipment may be adversely affected by the harmonic current. There, passive or active filter have been used to reduce these harmonics current. Passive filter consisting of inductor and capacitor generates a reactive power. According to the combination of filter inductor and capacitor, reactive power can be adjusted. In this paper, we analyzed how the combination of inductor and capacitor affects the overall power factor by simulation and measurement.

Push-Pull 패스 트랜지스터 구조 및 향상된 Load Transient 특성을 갖는 LDO 레귤레이터 (A Low Drop Out Regulator with Improved Load Transient Characteristics and Push-Pull Pass Transistor Structure)

  • 권상욱;송보배;구용서
    • 전기전자학회논문지
    • /
    • 제24권2호
    • /
    • pp.598-603
    • /
    • 2020
  • 본 논문에서는 Push-Pull 패스 트랜지스터 구조로 인하여 향상된 Load Transient 특성을 향상시킨 LDO(Low Drop-Out)를 제안하였다. LDO 레귤레이터 내부의 오차증폭기의 출력단과 패스 트랜지스터의 게이트단 사이에 제안된 Push-Pull 회로와 출력단에 Push-Pull 회로를 추가하여 전압 라인에 들어오는 Overshoot, Undershoot를 개선시켜 기존의 LDO 레귤레이터보다 개선된 Load Transient 특성의 델타 피크 전압 값을 갖는다. 제안하는 회로는 Cadence의 Virtuoso, Spectre 시뮬레이션을 이용하여 삼성 0.13um 공정에서 특성을 분석하였다.

3상 4선식 저압 배전선로에서 선형 및 비선형 부하의 사용시 전압 불평형률 비교 분석 (Comparative Analysis of Voltage Unbalance Factor on the use of Linear and Non-linear loads in Three-phase Four-wire Low Voltage Distribution Line)

  • 김종겸;김지명
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.587-592
    • /
    • 2017
  • In the three-phase four-wire low-voltage power distribution equipment, single-phase and three-phase load have been used mainly mixed. Also linear and nonlinear loads have been used together in the same conditions. In a three-phase four-wire distribution line, the current distribution of three-phase linear load is almost constant in each phase during driving or stopping, but the single-phase load is different from each other for each phase in accordance with the operation and stop. So that the voltage unbalance is caused by the current difference of each phase. In the three-phase four-wire distribution system, non-linear load is used with linear load. The presence of single-phase nonlinear loads can produce an increase in harmonic currents in three-phase and neutral line. It can also cause voltage unbalance. In the present study, we analyzed for the voltage unbalance fluctuations by the operation pattern of the single and three-phase linear and non-linear load in three-phase four-wire low voltage distribution system.

Investigation of Low-Frequency Characteristics of Four-Switch Three-Phase Inverter

  • Yuan, Qingwei;Cheng, Chong;Zhao, Rongxiang
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1471-1483
    • /
    • 2017
  • The low-frequency characteristics of four-switch three-phase (FSTP) inverter are investigated in this paper. Firstly, a general space vector pulse width modulation (SVPWM) directly involved the neutral point voltage of DC-link is proposed, where no sector identifications and trigonometric function calculations are needed. Subsequently, to suppress the DC offset in the neutral point voltage, the relationship between the neutral point voltage and the ${\beta}-axis$ component of the load current is derived, and then a new neutral point voltage control scheme is proposed where no low pass filter is adopted. Finally, the relationship between the load power factor and the maximum linear modulation index of the FSTP inverter is revealed. Since the operational region for the FSTP inverter in low frequency is reduced by the enlarged amplitude of the neutral point voltage, a linear modulation range enlargement scheme is proposed. A permanent magnet synchronous motor with preset rotary speed serves as the low-frequency load of the FSTP inverter. Experimental results verify that the new neutral point voltage control scheme is effective in the deviation suppression of the neutral point voltage, and the proposed scheme is able to provide a larger linear operational region in low frequency.

Behaviour factor and displacement estimation of low-ductility precast wall system under seismic actions

  • Tiong, Patrick L.Y.;Adnan, Azlan;Hamid, Nor H.A.
    • Earthquakes and Structures
    • /
    • 제5권6호
    • /
    • pp.625-655
    • /
    • 2013
  • This paper investigated the seismic behaviour of an innovated non-ductile precast concrete wall structural system; namely HC Precast System (HCPS). The system comprises load-bearing precast wall panels merely connected only to column at both ends. Such study is needed because there is limited research information available in design codes for such structure particularly in regions having low to moderate seismicity threats. Experimentally calibrated numerical model of the wall system was used to carry out nonlinear pushover analyses with various types of lateral loading patterns. Effects of laterally applied single point load (SPL), uniformly distributed load (UDL), modal distributed load (MDL) and triangular distributed load (TDL) onto global behaviour of HCPS were identified. Discussion was focused on structural performance such as ductility, deformability, and effective stiffness of the wall system. Thus, a new method for engineers to estimate the nonlinear deformation of HCPS through linear analysis was proposed.