• 제목/요약/키워드: low level laser

검색결과 249건 처리시간 0.029초

동일기관 내 협진을 통한 돌발성 난청의 한·양방 병용치험 3례 (Three Cases of Sudden Hearing Loss Improved after East-West Medical Combined Treatment through Cooperation in a Hospital)

  • 이지원;홍승욱
    • 한방안이비인후피부과학회지
    • /
    • 제35권2호
    • /
    • pp.82-94
    • /
    • 2022
  • Objectives : The purpose of this study is to report the effect of east-west medical combined treatment of sudden sensorineural hearing loss(SSNHL) through cooperation in a hospital. Methods : We treated three patients diagnosed as SSNHL by combination of herbal medicine, acupuncture, pharmoacupuncture, moxibustion, cupping, laser therapy and conventional medications. We evaluated the results of this treatment with pure tone audiometry, word recognition score(WRS), the changes in distortion product otoacoustic emissions(DPOAE) and visual analogue scale. Results : One of them showed a meaningful improvement in the hearing level of the low frequency region. The others showed 'Complete recovery' in pure tone audiometry and WRS. The subjective symptoms including tinnitus and ear fullness improved in three patients. Conclusion : This study suggests that east-west medical combined treatment is effective on SSNHL patients.

비접촉 화학작용제 검출기의 MCT 광검출기를 위한 적분기 기반의 리드아웃 회로 구현 (Realization of Readout Circuit Through Integrator to Average MCT Photodetector Signals of Noncontact Chemical Agent Detector)

  • 박재현
    • 센서학회지
    • /
    • 제31권2호
    • /
    • pp.115-119
    • /
    • 2022
  • A readout circuit for a mercury-cadmium-telluride (MCT)-amplified mid-wave infrared (IR) photodetector was realized and applied to noncontact chemical agent detectors based on a quantum cascade laser (QCL). The QCL emitted 250 times for each wavelength in 0.2-㎛ steps from 8 to 12 ㎛ with a frequency of 100 kHz and duty ratio of 10%. Because of the nonconstant QCL emission power during on-duty, averaging the photodetector signals is essential. Averaging can be performed in digital back-end processing through a high-speed analog-to-digital converter (ADC) or in analog front-end processing through an integrator circuit. In addition, it should be considered that the 250 IR data points should be completely transferred to a PC during each wavelength tuning period of the QCL. To average and minimize the IR data, we designed a readout circuit using the analog front-end processing method. The proposed readout circuit consisted of a switched-capacitor integrator, voltage level shifter, relatively low-speed analog-to-digital converter, and micro-control unit. We confirmed that the MCT photodetector signal according to the QCL source can be accurately read and transferred to the PC without omissions.

The efficacy of photobiomodulation on dental injection pain: a systematic review of randomized clinical trials

  • Maryam Altuhafy;Virda Baig;Luay Jabr;Junad Khan
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제24권3호
    • /
    • pp.145-159
    • /
    • 2024
  • Dental injections are routinely performed and can result in pain and anxiety in patients. This systematic review aimed to evaluate the efficacy of photobiomodulation therapy (PBMT) in dental injections for pain management in patients undergoing dental treatment. Indexed databases, including PubMed, EMBASE, Scopus, ISI Web of Knowledge, and Cochrane Library, were electronically searched without a time limit up to February 2024. A risk of bias evaluation was performed using the Cochrane tool. A preliminary investigation using electronic and manual methods yielded 4,920,881 manuscripts. Based on the eligibility requirements, 13 randomized control trials (RCTs) were included. Self-assessed pain was determined using the visual analog scale, Face, Legs, Activity, Cry, Controllability scale, or Wong-Baker face pain scale. Eight RCTs demonstrated a notable decrease in needle pain in patients undergoing dental needle injections using PBMT. Based on current evidence, PBMT may help reduce needle pain related to dental anesthesia. Further standardized studies are needed to assess the significance of PBMT for postoperative pain in patients undergoing dental injections.

백서(白鼠)의 신경병리성(神經病理性) 동통(疼痛)에 대한 후계(後谿).위중(委中) 혈위(穴位) 호침료법(毫鍼療法)과 레이저 침습조사(侵襲照射) 침료법(鍼療法)과의 비교(比較) 연구(硏究) (Comparative study of acupuncture and invasive laser acupuncture therapy at $SI_3$.$BL_{40}$ on the tibial, sural nerve injury and L5 spinal nerve ligation model in rats)

  • 위통순;윤대환;윤여충;나창수
    • Korean Journal of Acupuncture
    • /
    • 제22권2호
    • /
    • pp.9-24
    • /
    • 2005
  • Objective: We have studied the effects of acupuncture and low level He-Ne laser therapy(LLLT) at $SI_3$, $BL_{40}$ on the tibial, sural nerve injury due to sports-damage or traffic accident and L5 spinal nerve ligature model like general herniation of nucleus pulposus(HNP) in a rat of neuopathic pain. Methods: A model of neuropathic pain was made by injuring tibial nerve and sural nerve while common peroneal nerve was maintained. Also, it was made by isolating left 5th lumbar spinal nerve. Three weeks after the neuropathic surgery, acupuncture and LLLT was injected at $SI_3$,$BL_{40}$ one time a day for one week. LLLT was divided three groups, that is LLLT-1(5mW), LLLT-2(10mW) and LLLT-3(30mW). After that, we examined the withdrawal response of neuropathic rats' legs by Von frey filament and acetone stimulation. And also we examined c-Fos, Nocieptin and KOR-3 in the midbrain central gray of neuropathic rats. Results: As we have observed the effect of mechanical allodynia, LLLT-3 group were diminished on 4 day, 5 day, 6 day and 7 day in the resection model compared with control model, LLLT-1 group were diminished on 5 day, LLLT-2 group were diminished on 3 day and 6 day, LLLT-3 group were diminished on 3 day, 4 day, 5 day, 6 day and 7 day in connected model compared with control group. As we have observed the effect of cold allodynia, LLLT-3 group were diminished on 7 day in the resection model compared with control model, LLLT-1 group were diminished on 6 day, 7 day, LLLT-3 group were diminished on 7 day in connected model compared with control group. As we have observed the effect of activity of c-Fos in the central gray part, LLLT-3 were diminished in resection model compared with control group, LLLT-1 group were diminished in connected model compared with control group. As we have observed the effect of activity of Nociceptin in the central gray part, resection model were not increased compared with control group, LLLT-1 group and LLLT-3 group were increased in connected model compared with control model. As we have observed the effect of activity of KOR-3 in the central gray part, resection model were not increased compared with control group, LLLT-3 group were increased in connected model compared with control model. Conclusions: We have noticed that LLLT-1 and LLLT-3 group have more controllable effect than acupuncture group. This study can be used in clinical therapy for neuropathic pain. But it is not reliability that Nociceptin and KOR-3 have effectively to control pain. Therefore We have to follow up about that.

  • PDF

Rapid Identification of Vibrio Species Isolated from the Southern Coastal Regions of Korea by MALDI-TOF Mass Spectrometry and Comparison of MALDI Sample Preparation Methods

  • Cho, Youngjae;Kim, Eiseul;Han, Sun-Kyung;Yang, Seung-Min;Kim, Mi-ju;Kim, Hyun-Joong;Kim, Chang-Gyeom;Choo, Dong-Won;Kim, Young-Rok;Kim, Hae-Yeong
    • Journal of Microbiology and Biotechnology
    • /
    • 제27권9호
    • /
    • pp.1593-1601
    • /
    • 2017
  • Vibrio species are generally recognized as pathogens predominant in seafood along coastal areas. The food industry has sought to develop efficient microbial detection methods. Owing to the limits of conventional methods, this study aimed to establish a rapid identification method for Vibrio isolated from Korea, based on matrix-assisted laser-desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). Four different preparation procedures were compared to determine the appropriate means to pretreat Vibrio species, using 17 isolates and five reference strains. Extended direct transfer and full formic acid extraction methods using bacterial colonies on agar plates revealed very low identification rates. Formic acid and trifluoroacetic acid (TFA) extractions using bacterial broth cultures were also performed. All Vibrio isolates and reference strains prepared by TFA extraction were successfully identified to the species level (17/22, 77.3%) and to the genus level (5/22, 22.7%). Thus, TFA extraction was considered the most appropriate method to pretreat Vibrio species for MALDI-TOF MS. The remaining 33 isolates and two reference strains were prepared by TFA extraction and analyzed by MALDI-TOF MS. Overall, 50 isolates were identified to the species level (40/50, 80%) and to the genus level (10/50, 20%). All isolates were identified as 43 V. alginolyticus, six V. parahaemolyticus, and one V. vulnificus species. V. alginolyticus and V. parahaemolyticus were isolated from fish offal (87.5% and 12.5%, respectively), seawater (91.3%, 8.7%), and shellfish (62.5%, 37.5%), whereas V. alginolyticus and V. vulnificus were isolated from sediment (90.9% and 9.1%, respectively). This study established a reliable system of MALDI-TOF MS preparation and analysis for Vibrio identification.

열화상 카메라를 적용한 개인 맞춤형 냉각관리 시스템 (Personalized Cooling Management System with Thermal Imaging Camera)

  • 이영지;이주현;이승호
    • 전기전자학회논문지
    • /
    • 제25권4호
    • /
    • pp.782-785
    • /
    • 2021
  • 본 논문에서는 열화상 카메라를 적용한 개인 맞춤형 냉각관리 시스템을 제안한다. 제안하는 장비는 열화상 카메라를 이용하여 사용자의 진행 전 피부 온도와 진행 후 피부온도의 차이에 따라 냉기 배출량 및 시스템을 제어한다. 피부의 온도가 비정상적으로 낮아지면 냉기공급을 차단하여 안전사고 발생 가능성을 방지한다. 피부 온도 감지센서를 열화상 카메라 온도측정으로 대체하여 경제적이고, 열화상 이미지로 온도를 확인할 수 있으므로 시각화가 가능하다. 또한, 제안하는 장비는 열화상 카메라를 적용한 개인 맞춤형 냉각관리 시스템의 안전을 위해 레이저 포인터를 듀얼로 사용하여 초점 거리를 산출하여 피부와의 거리를 측정하는 센서의 감도를 개선시킨다. 제안된 장비의 성능을 평가하기 위하여 외부공인 시험기관에서 실험하였다. 첫 번째로 측정된 온도 범위는 -100℃~-160℃로 측정되어, 현재 현장에서 사용되는 최고 수준인 -150~-160℃(cryo generation/미국) 보다 넓은 온도 범위를 나타내었다. 또한 오차는 ±3.2%~±3.5%로 측정되어 현재 현장에서 사용되는 최고 수준인 ±5%(CRYOTOP/중국) 보다 우수한 결과를 나타내었다. 두 번째로 측정된 거리 정확도는 ±4.0% 이하로 측정되어, 현재 현장에서 사용되는 최고 수준인 ±5%(CRYOTOP/중국) 보다 우수한 결과를 나타내었다. 세 번째로 질소 사용량은 최대 0.15 L/min 미만으로 확인되어, 현재 현장에서 사용되는 최고 수준인 6 L/min(POLAR BEAR/미국) 보다 우수한 결과를 나타내었다. 따라서 본 본문에서 제안한 열화상 카메라를 적용한 개인 맞춤형 냉각관리 시스템의 성능의 우수함이 판별되었다.

레이저 3D 프린팅 기법으로 제작한 열교환기 성능시험 분석 연구 (Experimental analysis of heat exchanger performance produced by laser 3D printing technique)

  • 김무선
    • 한국산학기술학회논문지
    • /
    • 제21권7호
    • /
    • pp.270-276
    • /
    • 2020
  • 3D 프린팅은 고분자, 세라믹, 금속 등 다양한 소재를 대상으로 복합적인 형상을 한 번의 공정으로 제작할 수 있는 적층 기반 제작 기술이다. 최근의 3D 프린팅 기술은 프린팅 속도의 향상과 적용 가능 소재의 지속적인 개발에 의해 양산형 제품 생산이 가능한 수준으로 발전하였다. 본 연구에서는 레이저를 활용한 3D 프린팅 기술을 적용하여 철도 차량용 공기 압축기에 쓰이는 열교환기 제작을 진행하였다. 먼저 3D 프린팅에 적합한 형상으로 경량화 및 컴팩트화를 주안점으로 열교환기의 최적 설계를 진행하였다. 그로부터 도출된 설계안을 기반으로 SLM 기법을 적용하여 AlSi10Mg 합금 소재로 열교환기 시작품을 제작하였다. 다음으로, 제작된 시작품을 기존 공기 압축기에 부착하여, 압축공기의 열교환 성능을 시험하였다. 3D 프린팅 시작품의 시험 결과는 기존 열교환기 대비하여 저압부와 고압부에서 열교환 성능은 각각 약 80% 및 85% 수준을 보였다, 하지만 외부 냉각공기 조건을 기존 열교환기와 유사한 조건으로 가정하였을 때 𝓔-NTU 법을 활용하여 계산한 열전달량은 기존 열교환기 대비하여 유사한 성능을 보여 주었다. 결과적으로, 3D 프린팅 제작 열교환기의 성능 효과 및 경량화 등의 장점을 확인할 수 있었다.

알루미늄 박 및 플레이트 표면 미세 패터닝을 위한 상온 임프린팅 기술 (Room Temperature Imprint Lithography for Surface Patterning of Al Foils and Plates)

  • 박태완;김승민;강은빈;박운익
    • 마이크로전자및패키징학회지
    • /
    • 제30권2호
    • /
    • pp.65-70
    • /
    • 2023
  • 나노임프린트 리소그래피(Nanoimprint lithography, NIL) 공정은 패턴 형성을 위한 공정 단순성, 우수한 패턴 형성, 공정의 확장성, 높은 생산성 및 저렴한 공정 비용이라는 이유들로 인해 많은 관심을 받고 있다. 그러나, 기존의 NIL 기술들을 통해 금속 소재 상 구현할 수 있는 패턴의 크기는 일반적으로 마이크로 수준으로 제한적이다. 본 연구에서는, 다양한 두께의 금속 기판 표면에 마이크로/나노 스케일 패턴을 직접적으로 형성하기 위한 극압 임프린트 리소그래피(extremepressure imprint lithography, EPIL) 방법을 소개하고자 한다. EPIL 공정은 자외선, 레이저, 임프린트 레지스트 또는 전기적 펄스 등의 외부 요인을 사용하지 않고 고분자, 금속, 세라믹과 같은 다양한 재료의 표면에 신뢰성 있는 나노 수준의 패터닝을 가능하게 한다. 레이저 미세가공 및 포토리소그래피로 제작된 마이크로/나노 몰드는 상온에서 높은 하중 혹은 압력을 가해 정밀한 소성변형 기반 Al 기판의 나노 패터닝에 활용된다. 20 ㎛ 부터 100 ㎛까지 다양한 두께를 갖는 Al 기판 상 마이크로/나노 스케일의 패턴 형성을 보여주고자 한다. 또한, 다목적 EPIL 기술을 통해 금속 재료 표면에서 그 형상을 제어하는 방법 역시 실험적으로 증명된다. 임프린트 리소그래피 기반 본 접근법은 복잡한 형상이 포함된 금속 재료의 표면을 요구하는 다양한 소자 응용을 위한 나노 제조 방법에 적용될 수 있을 것으로 기대한다.

Metabolic Characteristic of the Liver of Dairy Cows during Ketosis Based on Comparative Proteomics

  • Xu, Chuang;Wang, Zhe;Liu, Guowen;Li, Xiaobing;Xie, Guanghong;Xia, Cheng;Zhang, Hong You
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제21권7호
    • /
    • pp.1003-1010
    • /
    • 2008
  • The objective of the present study was to identify differences in the expression levels of liver proteins between healthy and ketotic cows, establish a liver metabolic interrelationship of ketosis and elucidate the metabolic characteristics of the liver during ketosis. Liver samples from 8 healthy multiparous Hostein cows and 8 ketotic cows were pooled by health status and the proteins were separated by two-dimensional-electrophoresis (2D-E). Statistical analysis of gels was performed using PDQuest software 8.0. The differences in the expression levels of liver proteins (p<0.05) between ketotic and healthy cows were identified by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF-TOF) tandem mass spectrometry. Five enzymes/proteins were identified as being differentially expressed in the livers of ketotic cows: expression of 3-hydroxyacyl-CoA dehydrogenase type-2 (HCDH), acetyl-coenzyme A acetyltransferase 2 (ACAT) and elongation factor Tu (EF-Tu) were down-regulated, whereas that of alpha-enolase and creatine kinase were up-regulated. On the basis of this evidence, it could be presumed that the decreased expression of HCDH, which is caused by high concentrations of acetyl-CoA in hepatic cells, in the livers of ketotic cows, implies reduced fatty acid ??oxidation. The resultant high concentrations of acetyl-CoA and acetoacetyl CoA would depress the level of ACAT and generate more ??hydroxybutyric acid; high concentrations of acetyl-CoA would also accelerate the Krebs Cycle and produce more ATP, which is stored as phosphocreatine, as a consequence of increased expression of creatine kinase. The low expression level of elongation factor Tu in the livers of ketotic cows indicates decreased levels of protein synthesis due to the limited availability of amino acids, because the most glucogenic amino acids sustain the glyconeogenesis pathway; thus increasing the level of alpha-enolase. Decreased protein synthesis also promotes the conversion of amino acids to oxaloacetate, which drives the Krebs Cycle under conditions of high levels of acetyl-CoA. It is concluded that the livers of ketotic cows possess high concentrations of acetyl-CoA, which through negative feedback inhibited fatty acid oxidation; show decreased fatty acid oxidation, ketogenesis and protein synthesis; and increased gluconeogenesis and energy production.

Substrate roughness induces the development of defective E-cadherin junctions in human gingival keratinocytes

  • Jin, Chengbiao;Lee, Gayoung;Oh, Changseok;Kim, Hyun Jung;Kim, Hyun-Man
    • Journal of Periodontal and Implant Science
    • /
    • 제47권2호
    • /
    • pp.116-131
    • /
    • 2017
  • Purpose: The entry of bacteria or harmful substances through the epithelial seal of human gingival keratinocytes (HGKs) in the junctional epithelium (JE) is blocked by specialized intercellular junctions such as E-cadherin junctions (ECJs). However, the influence of roughened substrates, which may occur due to apical migration of the JE, root planing, or peri-implantitis, on the development of the ECJs of HGKs remains largely unknown. Methods: HGKs were cultured on substrates with varying levels of roughness, which were prepared by rubbing hydrophobic polystyrene dishes with silicon carbide papers. The activity of c-Jun N-terminal kinase (JNK) was inhibited with SP600125 or by transfection with JNK short hairpin RNA. The development of intercellular junctions was analyzed using scanning electron microscopy or confocal laser scanning microscopy after immunohistochemical staining of the cells for E-cadherin. The expression level of phospho-JNK was assessed by immunoblotting. Results: HGKs developed tight intercellular junctions devoid of wide intercellular gaps on smooth substrates and on rough substrates with low-nanometer dimensions (average roughness $[Ra]=121.3{\pm}13.4nm$), although the ECJs of HGKs on rough substrates with low-nanometer dimensions developed later than those of HGKs on smooth substrates. In contrast, HGKs developed short intercellular junctions with wide intercellular gaps on rough substrates with mid- or high-nanometer dimensions ($Ra=505.3{\pm}115.3nm$, $867.0{\pm}168.6nm$). Notably, the stability of the ECJs was low on the rough substrates, as demonstrated by the rapid destruction of the cell junction following calcium depletion. Inhibition of JNK activity promoted ECJ development in HGKs. JNK was closely associated with cortical actin in the regulation of ECJs in HGKs. Conclusions: These results indicate that on rough substrates with nanometer dimensions, the ECJs of HGKs develop slowly or defectively, and that this effect can be reversed by inhibiting JNK.