• Title/Summary/Keyword: low leakage

Search Result 1,336, Processing Time 0.035 seconds

High-Isolation SPDT RF Switch Using Inductive Switching and Leakage Signal Cancellation

  • Ha, Byeong Wan;Cho, Choon Sik
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.4
    • /
    • pp.411-414
    • /
    • 2014
  • A switch is one of the most useful circuits for controlling the path of signal transmission. It can be added to digital circuits to create a kind of gate-level device and it can also save information into memory. In RF subsystems, a switch is used in a different way than its general role in digital circuits. The most important characteristic to consider when designing an RF switch is keeping the isolation as high as possible while also keeping insertion loss as low as possible. For high isolation, we propose leakage signal cancellation and inductive switching for designing a singlepole double-throw (SPDT) RF switch. By using the proposed method, an isolation level of more than 23 dB can be achieved. Furthermore, the heterojunction bipolar transistor (HBT) process is used in the RF switch design to keep the insertion loss low. It is demonstrated that the proposed RF switch has an insertion loss of less than 2 dB. The RF switch operates from 1 to 8 GHz based on the $0.18-{\mu}m$ SiGe HBT process, taking up an area of $0.3mm^2$.

Developing the Construction Guideline for ZEB Based on Air-tightness of Public Buildings in Korea (국내 비주거용 건물의 기밀성능 측정 결과를 통한 기밀 시공 가이드라인 개발)

  • Bae, Minjung;Choi, Gyeongseok
    • Land and Housing Review
    • /
    • v.11 no.3
    • /
    • pp.69-74
    • /
    • 2020
  • Since the design Standard for Energy Conservation in Building was implemented in 2008 for the first time, building elements such as window and door should satisfy the minimum criteria to apply for a building. Though its regulation does not cover the whole building yet, recent demand to reduce energy consumption in building sector grows rapidly year by year and also draws a lot of interest to ensure the whole building level. For example, a Zero energy building, one of low-energy buildings, requires a customized solution to resolve the air leakage issue to meet the standards in achieving the high level of air tightness. In this study, six non-residential buildings were tested by fan pressurization method to observe the air tightness of whole building to suggest the construction guideline for air tightness of low-energy building. Five out of six tested buildings showed 0.27 to 1.16 h-1 of number of air changes except one community center. These buildings were carefully constructed not only for building planning but also for parts where there was a concern of air leakage, thereby securing high levels of air-tightness. The construction skills were developed as a checklist to manage and supervise the construction site. It is our suggestion to use this checklist at construction sites for ZEB with the high level of air-tightness.

The Structure and Dielectric Properties of the (Ba,Sr)TiO$_3$ Thin Films with the Substrate Temperature (기판온도에 따른 (Ba,Sr)TiO$_3$ 박막의 구조와 유전특성)

  • 이상철;이문기;이영희
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.11
    • /
    • pp.603-608
    • /
    • 2000
  • $(Ba, Sr)TiO_{3}$[BST] thin films were fabricated on the Pt/TiO$_2$/SiO$_2$/Si substrate by the RF sputtering. The structure and dielectric properties of the BST thin films with the substrate temperature were investigated. Increasing the substrate temperature, The BST phase increased and barium multi titanate phases decreased. Increasing the frequency, the dielectric constant decreased and the dielectric loss increased. The dielectric constant and dielectric loss of the BST thin films deposited at 50$0^{\circ}C$ were 300 and 0.018, respectively at 1 kHz. The leakage current density of the BST thin films deposited at 50$0^{\circ}C$ was $10^{-9}$ A/$\textrm{cm}^2$ with applied voltage of 3V. Because of the high dielectric constant(300), low dielectric loss(0.018) and low leakage current($10^{-9}$ A/$\textrm{cm}^2$), BST thin films deposited at 50$0^{\circ}C$ is expecting for the application of DRAM.

  • PDF

A Study on the High Speed Interruption of Parallel Arcing (병렬아크의 고속차단에 관한 연구)

  • Kil, Gyung-Suk;Ji, Hong-Keun;Park, Dae-Won;Kim, Il-Kwon;Kim, Young-Il;Cho, Young-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.95-100
    • /
    • 2008
  • Conventional Earth Leakage Circuit Breakers (ELCBs) have defects of a breaking failure or a long breaking-time against parallel arc current. In this paper, breaking characteristics of conventional ELCBs were analyzed by simulation of parallel arc in a low-voltage indoor wiring system, and an air-core current sensor and a signal converter being most available for parallel arc detection were developed and applied to a conventional ELCB. The proposed tripped the ELCB regardless of the location of parallel arc. The breaking-time was in ranges of $1.74{\sim}8.3[ms]$ depending on the phase of arc generation, which is about 5 times as fast as conventional ELCBs with the breaking-time of 50[ms].

Chilling Responses of Chilli Pepper Fruits at Different Ripening Stages to Low Temperature during Storage

  • Lim, Chae-Shin;An, Chul-Geon;Huh, Moo-Ryong
    • Journal of agriculture & life science
    • /
    • v.44 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • This study was conducted to investigate effect of low temperature and ripeness stages on fruit quality of chilli pepper (cv. Nockgwang) during storage at 5, 7, and $10^{\circ}C$. Fruits at three ripeness stages were selected based on uniform fruit size and three maturities on peel color: S1 (fully developed fruit just before the onset of ripening), S2 (fruits in the onset of color change), and S3 (fruits in completely red in color). Lower temperature attributed to increase fruit weight loss (WL) and WL was higher in S2 than the other ripeness stages. The highest respiration rate and ethylene production was found at S2 fruit while those of fruit in green and red showed similar and remained lower level during storage. Electrolyte leakage (EL) was higher as storage temperature decreased. After 28 d storage, EL rates of fruits at $5^{\circ}C$ were 43, 36, and 17% in S1, S2, and S3 while those at $10^{\circ}C$ were 17, 19, and 14%, respectively. These results show that chilli pepper fruits are tended to lose more water at lower temperature partially associated with increased EL. Thus, threshold storage temperature must be considered for avoiding chilling during storage and for extending the storage life of fresh pepper fruits.

A Study on the Physical Characteristics of the Low-voltage Circuit Breaker Based on the Accelerated Degradation Test (가속 열화 시험에 따른 저압용 차단기의 물리적 특성에 관한 연구)

  • Sin dong, Kang;Jae-Ho, Kim
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.6
    • /
    • pp.1-8
    • /
    • 2022
  • This study analyzed the characteristics of insulation resistance and operating time based on an accelerated degradation test of a low-voltage circuit breaker. The experimental sample used a molded case circuit breaker (MCCB) and an earth leakage circuit breaker (ELCB). After measuring the insulation resistance of the circuit breakers, the leakage current was affected by an external rather than an internal structure. Furthermore, the insulation resistance of the circuit breakers with accelerated degradation was measured using a Megger insulation tester. In the accelerated degradation test, aging times of five, ten, 15, and 20 years were applied according to a temperature derived using the Arrhenius equation. Circuit breakers with an equivalent life of ten, 15, and 20 years had increased insulation resistance compared to those with less degradation time. In particular, the circuit breaker with an equivalent life of ten years had the highest insulation resistance. Component analysis of the circuit breaker manufactured through an accelerated degradation test confirmed that the timing of the increase in insulation resistance and the time of additive loss were the same. Finally, after analyzing the operating time of the circuit breakers with degradation, it was confirmed that the MCCB did not change, but the ELCB breaker failed.

Fabrication and Characterization of Composite Sealants for Low Temperature (600∼650°C)SOFCs (저온작동 (600∼650°C) SOFC용 복합밀봉재 제조 및 평가)

  • Lim, Hyun-Yub;Kim, Hyoung-Chul;Choi, Sun-Hee;Kim, Hae-Ryoung;Son, Ji-Won;Lee, Hae-Weon;Lee, Jong-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.12
    • /
    • pp.802-806
    • /
    • 2008
  • A proper sealant for low temperature SOFCs should show zero or low leak rates to avoid direct mixing of the fuel and oxidant gases or leakage of fuel gas during the operation of SOFCs. Furthermore, it should be chemically and/or mechanically stable in both oxidizing and reducing environments and chemically compatible with other fuel cell components. In the present work, we developed a novel compressed seal gasket of glass-based composite reinforced with ceramic particulate particles, which can efficiently control the viscous flow of glass matrix as well as the crystallization of glass phase. This novel sealing gasket showed excellent gas tightness under very low compressive load which would be suitable for the operation of SOFCs in the temperature range $600{\sim}650^{\circ}C$.

Evaluation of Stapled versus Hand-Sewn Techniques for Colo-Rectal Anastomosis after Low Anterior Resection of Mid-Rectal Carcinoma: a Study on 50 Patients

  • Fayek, Ihab Samy
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.13
    • /
    • pp.5427-5431
    • /
    • 2014
  • Aim: To evaluate the outcome of stapled versus sutured colo-rectal anastomosis after low anterior resection of mid-rectal carcinoma. Patients and Methods: A prospective study of fifty patients who underwent colo-rectal anastomosis following low anterior resection (LAR) of T2 mid-rectal cancers at the Egyptian National Cancer Institute during the time period from June 2010 to June 2013 was conducted. Classification was into two groups; a stapled anastomosis group I (25 patients) and a hand-sewn anastomosis group II (25 patients). All operations are evaluated regarding intra-operative complications such as anastomotic line bleeding, visceral injuries or major blood loss. The anastomotic time and operative time are documented for each operation. All patients are evaluated post-operatively for anastomotic leakage (AL), wound infection and ileus. Results: The distance of the tumor from the anal verge was $9.6{\pm}2.0cm$ in group I and $9.9{pm}2.4cm$ in group II. The mean operative time was $191.5{\pm}16.2min$ in the stapled group and $208{\pm}18.6min$ in the sutured group (p=0.002). The mean anastomotic times were $9.0{\pm}1.9min$ and $19.7{pm}12.2min$ (p=0.001). Anastomotic leakage developed in three (12.0%) patients in the stapled group and in four (16.0%) patients in the sutured group (p=1.000). Post-operative ileus was observed in 3 patients in group I and one patient in group II. Wound infection developed in three (12.0%) patients in the stapled group and four (16.0%) patients in the sutured group (p=1.000). Conclusion: Colo-rectal anastomosis after low anterior resection for mid rectal carcinoma can be conducted safely either by stapling or hand-sewn techniques; however the stapling technique showed shorter anastomotic and operative times with no significant advantages regarding intra- or post-operative complications or hospital stay.

Development of the Starting Algorithm and Starter for Turbo Generator (터보 제너레이터의 시동 알고리즘 및 시동기 개발)

  • 노민식;박승엽
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.17-24
    • /
    • 2004
  • The starter of the turbo generator is composed of a high speed generator(HSG), an inverter and a boost converter instead of a gearbox, a DC motor and a low-voltage battery in the starter of the turbo shaft generation system. Because turbo generator is needed a high speed motoring at start-up, high speed generator has a low leakage inductance and inverter need a high DC link voltage. In this study, for developing the stater of a turbo generator, a boost converter with a high capacity was developed to convert high voltage from a low battery voltage. And for controlling a high frequency current to be injected to a motor winding with a low leakage inductance, the inverter with a high precision and a high speed operation was designed and for a stable ignition, the starting algorithm of a turbo generator was proposed. Turbo generator was started by the starter developed to verify the performances.

Relationship between Seed Vigour and Electrolyte Leakage in Rice Seeds with Different Grain-filling Period

  • Kim, Jin-Ho;Lee, Sheong-Chun;Song, Dong-Seog
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.43 no.3
    • /
    • pp.147-151
    • /
    • 1998
  • The conductivity test is a measure of electrolytes leakage from plant tissue. The shorter the maturation period after heading was the greater electrical conductivity (EC) of rice seed. The polymer-coated seed was not different in EC compared with non-coated seed. As soaking time of rice seed increased, EC increased gradually. The EC varied from 9.9 to 20.7$\mu$S $cm^{-1}g^{-l}$ for control plots and from 21.3 to 41.7$\mu$S $cm^{-1}g^{-l}$ for heat-killed seeds which were produced by autoclaving seeds at 121$^{\circ}C$ for 20 minutes. The germination speed (the rate of 5th day) of rice seed was 94% at control plot, 83% at low temperature and 20% at high temperature. Besides, germination percentage was 95% for the control, 92% for the low temperature treatment and 39% for the high temperature treatment. The EC was negatively correlated (r=-0.771$^{**}$) with germination percentage at low temperature. Water uptake in seeds of 30, 40, 50 days after heading (DAH) was greater than that of 20 DAH. Plant height of seedlings was 9.84 cm for the control but 4.32 cm for the high temperature treatment, and the tallest for polymer-coated seed. Dry weight of seedlings was 0.841 g for the control and 0.287 g at high temperature. Besides, the polymer-coated seed was heavier than non-coated seed. The number of roots was largest from 40 to 50 DAH and polymer-coated seed, but was decreased from 20 to 30 DAH. The length of roots was 20.52 cm at control plot and 19.89 cm polymer-coated seed but 8.68 cm for the low temperature treatment and 7.28 cm for the high temperature treatment.

  • PDF