• Title/Summary/Keyword: low leakage

Search Result 1,336, Processing Time 0.037 seconds

Enhanced drought and oxidative stress tolerance in transgenic sweetpotato expressing a codA gene (CodA 고발현 형질전환 고구마의 산화 및 건조 스트레스 내성 증가)

  • Park, Sung-Chul;Kim, Myoung Duck;Kim, Sun Ha;Kim, Yun-Hee;Jeong, Jae Cheol;Lee, Haeng-Soon;Kwak, Sang-Soo
    • Journal of Plant Biotechnology
    • /
    • v.42 no.1
    • /
    • pp.19-24
    • /
    • 2015
  • Glycine betaine (GB) is one of the compatible solutes that accumulate in the chloroplasts of certain halotolerant plants under salt or cold stress. The codA gene for choline oxidase, the enzyme that converts choline into GB, has been cloned from a soil bacterium Arthrobacter globiformis. We generated transgenic sweetpotato plants [Ipomoea batatas (L.) Lam] expressing codA gene in chloroplasts under the control of the SWPA2 promoter (referred to as SC plants) and evaluated SC plants under oxidative and drought stresses. SC plants showed enhanced tolerance to methyl viologen (MV)-mediated oxidative stress and drought stress due to induced expression of codA. At $5{\mu}M$ of MV treatment, all SC plants showed enhanced tolerance to MV-mediated oxidative stress through maintaining low ion leakage and increased GB levels compared to wild type plants. When plants were subjected to drought conditions, SC plants showed enhanced tolerance to drought stress through maintaining high relative water contents and increased codA expression compared to wild type plants. These results suggest that the SC plants generated in this study will be useful for enhanced biomass production on global marginal lands.

Video-assisted Thoracic Surgery [VATS] in Diagnosis and Treatment of Thoracic Diaseas; Report of 90 Cases (비디오 흉강경: 흉부질환의 진단과 치료;90례 보고)

  • 백만종
    • Journal of Chest Surgery
    • /
    • v.26 no.6
    • /
    • pp.475-482
    • /
    • 1993
  • 90 patients[75 men and 15 women] with the thoracic disease underwent video-assisted thoracic surgery[VATS] during the period March 1992 to February 1993. The thoracic diseases were classified into two groups of spontaneous pneumothorax and general thoracic patients and they were 66 and 24, respectively.The mean size of the tumor resected was 4.3 $\pm$ 2.0 cm x 3.3 $\pm$ 1.1 cm x 2.7 $\pm$ 1.0 cm. The mean time of anesthesia and operation were 90.0 $\pm$ 19.9 min and 43.7 $\pm$ 13.1 min in spontaneous pneumothorax group and 123.3 $\pm$ 40.3 min and 62.8 $\pm$ 32.2 min in general thoracic group. The mean period of postoperative chest tube drainage and hospital stay were 5.0$\pm$ 5.5 days and 6.6 $\pm$ 7.4 days in spontaneous pneumothorax group and 3.5$\pm$ 1.6 days and 9.5 $\pm$ 6.1 days in general thoracic group. The indications of VATS were 71 pleural disease[78.9%: 66 spontaneous pneumothorax; 3 pleural effusions ; 1 pleural paragonimus westermanii cyst; 1 malignant pleural tumor with metastasis to the lung], 9 mediastinal disease[10.0%: 5 benign neurogenic tumor; 2 pericardial cyst; 1 benign cystic teratoma; 1 undifferentiated carcinoma], 8 pulmonary parenchymal disease[8.9%: 3 infectious disease ; 3 interstitial disease ; 2 malignant tumor ], and 2 traumatic cases of exploration and removal of hematoma[2.2%]. The applicated objectives of VATS were diagnostic[ 7 ], therapeutic[ 67 ] and both[ 16 ] and the performed procedures were pleurodesis[ 66 ], wedge resection of lung[ 59 ], parietal pleurectomy[ 11 ], removal of benign tumor[ 9 ], excision and/or biopsy of tumor[ 4 ], pleural biopsy and aspiration of pleural fluid[ 3 ] and exploration of hemothorax and removal of hematoma in traumatic 2 patients. The complication rate was 24.2%[ 16/66 ] in the spontaneous pneumothorax group and 8.3%[ 2/24 ] in the general thoracic group and so overally 20.0%[ 18/90 ]. The mortality within postoperative 30 days was 2.2%[ 2/90 ], including 1 acute renal failure and 1 respiratory failure due to rapid progression of pneumonia. The conversion rate to open thoracotomy during VATS was 5.6%[ 5/90 ], including 2 immediate postoperative massive air leakage, 1 giant bullae, 1 malignant pleural tumor with metastasis to lung and 1 pulmonary malignancy. The successful cure rate of VATS was 75.8%[ 50/66 ] in the spontaneous pneumothorax group and 76.5%[ 13/17 ] in the general thoracic group and the successful diagnostic rate was 100%[ 7/7 ]. In conclusion, although prospective trials should be progressed to define the precise role of VATS, the VATS carries a low morbidity and mortality and high diagnostic and therapeutic success rate and now can be effectively applicated to the surgical treatment of the extensive thoracic disease.

  • PDF

A study on the characteristic of the Groove corrosion of ERW carbon steel according to water speed (유속에 따른 ERW 탄소강관의 홈부식 특성에 관한 연구)

  • Kim, Jae-Seong;Lee, Young-Ki;Kim, Yong;Lee, Bo-Young
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.82-82
    • /
    • 2009
  • Although leakage at a low carbon steel pipe made by electrical resistance welding(ERW) was reported due to grooving corrosion, the cause for the corrosion has not yet been cleared. So lots of researches were carried out already about grooving corrosion mechanism of ERW carbon steel pipe but there is seldom study for water hammer happened by fluid phenomenon and corrosion rate by flow velocity. In this study, the corrosion test carried out using the ERW carbon steel pipe by changed the water speed and heat input in a month. The level of dissolved oxygen is maintained 5~5.5mg/l(amount of dissolved oxygen in tap water). The water speed for corrosion test is 1m/s, 2m/s, 3m/s. As the results, grooving corrosion rate is increased cause by water speed in the pipe. In the case of the ERW pipe with more heat input, grooving corrosion rate is decreased. It is therefore that welding heat input should be controlled based on the carbon content of the pipe in order to improve the corrosion reistance of the ERW pipe.

  • PDF

Physiology and Growth of Transgenic Tobacco Plants Containing Bacillus subtilis Protoporphyrinogen Oxidase Gene in Response to Oxyfluorfen Treatment (Bacillus subtilis Protoporphyrinogen Oxidase 유전자 형질전환 담배의 Oxyfluorfen 처리에 대한 생리 · 생장반응)

  • Lee, J.J.;Kuk, Y.I.;Chung, J.S.;Lee, S.B.;Choi, K.W.;Han, O.S.;Guh, J.O.
    • Korean Journal of Weed Science
    • /
    • v.18 no.3
    • /
    • pp.237-245
    • /
    • 1998
  • The transgenic tobacco (Nicotiana tabacum cv. Xanthi) plants containing Bacillus subtilis protoporphyrinogen oxidase gene with cauliflower mosaic virus 35S promoter have recently been generated by using Agrobacterium-mediated gene transformation. The nontransgenic and the transgenic tobacco plants were compared with respect to responses to diphenyl ether herbicide oxyfluorfen and under various environmental conditions. Both cellular leakage and lipid peroxidation caused by oxyfluorfen were found to be less in the transgenic than in the nontransgenic plants. Growth responses of the transgenic plants under various temperature, light, and water conditions were almost the same as those of the nontransgenic plants, although the transgenic plants exhibited slightly more retarded growth under low light or saturated water condition. These results revealed that the transgenic tobacco plants containing B. subtilis protoporphyrinogen oxidase gene under cauliflower mosaic virus 35S promoter were relatively resistant to oxyfluorfen and exhibited normal growth pattern. Possible mechanism of resistance to oxyfluorfen in the transgenic plants is also discussed.

  • PDF

The Effects of Electrode Materials on the Electrical Properties of $Ta_2O_5$ Thin Film for DRAM Capacitor (DRAM 커패시터용 $Ta_2O_5$ 박막의 전기적 특성에 미치는 전극의존성)

  • Kim, Yeong-Wook;Gwon, Gi-Won;Ha, Jeong-Min;Kang, Chang-Seog;Seon, Yong-Bin;Kim, Yeong-Nam
    • Korean Journal of Materials Research
    • /
    • v.1 no.4
    • /
    • pp.229-235
    • /
    • 1991
  • A new electrode material for $Ta_2O_5$ capacitor was developed to obtain both high dielectric constant and improved electrical properties for use in DRAM. High leakage current and low breakdown field of as-deposited $Ta_2O_5$ film on Si is due to the reduction of $Ta_2O_5$ by silicon at $Ta_2O_5$/electrode interface. $Dry-O_2$ anneal improves the electrical properties of $Ta_2O_5$ capacitor with Si electrode, but it thickens the interfacial oxide and lowers the dielectric constant, subsequently. $Ta_2O_5$ capacitor with TiN exectrode shows better electrical properties and higher dielectric constant than post heat treated $Ta_2O_5$ film on Si. No interfacial oxide layer at $Ta_2O_5$/TiN interface suggests that there\`s no Interaction between $Ta_2O_5$ and electrode. TiN is a adequate electrode material for $Ta_2O_5$ capacitor.

  • PDF

Micro fluxgate magnetic sensor using multi layer PCB process (PCB 다층 적층기술을 이용한 마이크로 플럭스게이트 자기 센서)

  • Choi, Won-Youl;Hwang, Jun-Sik;Choi, Sang-On
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.72-78
    • /
    • 2003
  • To observe the effect of excitation coil pitch on the micro fluxgate magnetic sensor, two sensors are fabricated using multi layer board process and the pitch distance of excitation coil are $260\;{\mu}m$ and $520\;{\mu}m$, respectively. The fluxgate sensor consists of five PCB stack layers including one layer of magnetic core and four layers of excitation and pick-up coils. The center layer as magnetic core is made of a Co-based amorphous magnetic ribbon with extremely high DC permeability of ${\sim}100,000$ and has a rectangular-ring shape to minimize the magnetic flux leakage. Four outer layers as excitation and pick-up coils have a planar solenoid structure and are made of copper foil. In case of the fluxgate sensor having the excitation coil pitch of $260\;{\mu}m$, excellent linear response over the range of $-100\;{\mu}T$ to $+100\;{\mu}T$ is obtained with sensitivity of 780 V/T at excitation sine wave of $3V_{p_p}$ and 360 kHz. The chip size of the fabricated sensing element is $7.3\;{\times}\;5.7\;mm^2$. The very low power consumption of ${\sim}8\;mW$ is measured. This magnetic sensor is very useful for various applications such as: portable navigation systems, telematics, VR game and so on.

Effects of the Ge Prearmophization Ion Implantation on Titanium Salicide Junctions (게르마늄 Prearmophization 이온주입을 이용한 티타늄 salicide 접합부 특성 개선)

  • Kim, Sam-Dong;Lee, Seong-Dae;Lee, Jin-Gu;Hwang, In-Seok;Park, Dae-Gyu
    • Korean Journal of Materials Research
    • /
    • v.10 no.12
    • /
    • pp.812-818
    • /
    • 2000
  • We studied the effects of Ge preamorphization (PAM) on 0.25$\mu\textrm{m}$ Ti-salicide junctions using comparative study with As PAM. For each PAM schemes, ion implantations are performed at a dose of 2E14 ion/$\textrm{cm}^2$ and at 20keV energy using $^{75}$ /As+and GeF4 ion sources. Ge PAM showed better sheet resistance and within- wafer uniformity than those of As PAM at 0.257m line width of n +/p-well junctions. This attributes to enhanced C54-silicidation reaction and strong (040) preferred orientation of the C54-silicide due to minimized As presence at n+ junctions. At p+ junctions, comparable performance was obtained in Rs reduction at fine lines from both As and Ge PAM schemes. Junction leakage current (JLC) revels are below ~1E-14 A/$\mu\textrm{m}^{2}$ at area patterns for all process conditions, whereas no degradation in JLC is shown under Ge PAM condition even at edge- intensive patterns. Smooth $TiSi_2$ interface is observed by cross- section TEM (X- TEM), which supports minimized silicide agglomeration due to Ge PAM and low level of JLC. Both junction break- down voltage (JBV) and contact resistances are satisfactory at all process conditions.

  • PDF

Water Balance Analysis of Pumped-Storage Reservoir during Non-Irrigation Period for Recurrent Irrigation Water Management (순환형 농업용수관리를 위한 농업용 저수지의 비관개기 양수저류 추정)

  • Bang, Na-Kyoung;Nam, Won-Ho;Shin, Ji-Hyeon;Kim, Han-Joong;Kang, Ku;Baek, Seung-Chool;Lee, Kwang-Ya
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.4
    • /
    • pp.1-12
    • /
    • 2020
  • The extreme 2017 spring drought affected a large portion of South Korea in the Southern Gyeonggi-do and Chungcheongnam-do districts. This drought event was one of the climatologically driest spring seasons over the 1961-2016 period of record. It was characterized by exceptionally low reservoir water levels, with the average water level being 36% lower over most of western South Korea. In this study, we consider drought response methods to alleviate the shortage of agricultural water in times of drought. It could be to store water from a stream into a reservoir. There is a cyclical method for reusing water supplied from a reservoir into streams through drainage. We intended to present a decision-making plan for water supply based on the calculation of the quantity of water supply and leakage. We compared the rainfall-runoff equation with the TANK model, which is a long-term run-off model. Estimations of reservoir inflow during non-irrigation seasons applied to the Madun, Daesa, and Pungjeon reservoirs. We applied the run-off flow to the last 30 years of rainfall data to estimate reservoir storage. We calculated the available water in the river during the non-irrigation season. The daily average inflow from 2003 to 2018 was calculated from October to April. Simulation results show that an average of 67,000 tons of water is obtained during the non-irrigation season. The report shows that about 53,000 tons of water are available except during the winter season from December to February. The Madun Reservoir began in early October with a 10 percent storage rate. In the starting ratio, a simulated rate of 4 K, 6 K, and 8 K tons is predicted to be 44%, 50%, and 60%. We can estimate the amount of water needed and the timing of water pump operations during the non-irrigation season that focuses on fresh water reservoirs and improve decision making for efficient water supplies.

Site Investigation for Pilot Scale $CO_2$ Sequestration by Magnetotelluric Surveys in Uiseong, Korea (이산화탄소 지중저장 Pilot 부지 선정을 위한 의성지역 MT 탐사)

  • Lee, Tae-Jong;Han, Nu-Ree;Ko, Kwang-Beom;Hwang, Se-Ho;Park, Kwon-Gyu;Kim, Hyung-Chan;Park, Yong-Chan
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.4
    • /
    • pp.299-308
    • /
    • 2009
  • A magentotelluric (MT) survey at the Uiseong area has been performed for the site investigation of pilot scale $CO_2$ sequestration. The purpose of the MT survey is to delineate deeply extended fracture systems that can act as a leakage path of injected $CO_2$ Plume. Since the target area is extremely noisy in electromagentic sense, low frequency data below 1 Hz cannot be used for inversion. Two- and three-dimensional interpretation of the MT data showed a very clear conductive anomaly, which has the direction of $N55\sim65^{\circ}W$ and is extended roughly down to 1.6 km. It have the same direction with the strike-slip faults, the Gaeum and Geumcheon Faults. On the contrary, the eastern part of the survey area shows relatively homogeneous to the depth of 2 km though some small fractures at shallow depths can be found. Test drilling and high-definition borehole surveys should be followed at the eastern part of the survey area and hydraulic fracturing is required for injection of $CO_2$, because mean porosity of the sedimetary rock in the area is only 1.47%.

The Development of a Multi-Purpose Irradiator and the Characteristic of Dose Distribution (다목적 방사선 조사장치 개발 및 선량분포특성)

  • Lee, Dong-Hoon;Ji, Young-Hoon;Lee, Dong-Han;Kim, Yoon-Jong;Hong, Seung-Hong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.6
    • /
    • pp.42-48
    • /
    • 2002
  • The design, construction and performance test of a convenient multi-purpose irradiator is described. A multi-purpose irradiator using Cesium-137 has been developed for studies of low dose radiation effects in biology and for calibration of Thermo Luminescent dosimeter(TLD). During the operation, three rods of radioactive material which are 10cm in length revolve 180 degrees and irradiate biological samples, or TLD, and return to their shielded position, after the programmed time. A programmable Logic Controller(PLC) controls the sequence of operation, interlock, motor rotation and safety system. The rotation speed of biological samples can vary up to 20 RPM. A real time monitoring system was also incorporated to check and control the operation status of the irradiator. The capacity of the irradiation chamber was 4.5 liters. The isodose distribution at arbitrary vertical planes was measured by using film dosimetry. The dose-rate was 0.13 cGy/min in air and 0.11 cGy/min in water equivalent material in the case of Cesium-137. Range of activity was 2 Ci. The homogeneity of dose distribution in the chamber was ${\pm}$7%. The actual radiation level on the surface was within permissible levels. The irradiator had a maximum 0.35 mR/min radiation leakage on its surface.