• 제목/요약/키워드: low frequency transformer

검색결과 241건 처리시간 0.031초

In-situ rf treatment of multiwall carbon nanotube with various post techniques for enhanced field emission

  • Ahn, Kyoung-Soo;Kim, Jun-Sik;Kim, Ji-Hoon;Kim, Chae-Ok;Hong, Jin-Pyo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.859-862
    • /
    • 2003
  • Well-aligned multiwall carbon nanotubes (MWCNTs) were prepared at low temperature of 400 $^{\circ}C$ by utilizing a radio frequency plasma-enhanced chemical vapor deposition (rf-PECVD) system. The MWCNTs were treated by an external rf plasma source and an ultra-violet laser in order to modify structural defect of carbon nanotube and to ablate possible contamination on carbon nanotube surface. Structural properties of carbon nanotubes were investigated by using a scanning electron microscopy (SEM), Raman spectroscopy, Fourier transformer Infrared spectroscopy (FTIR) and transmission electron microscope (TEM). In addition, the emission properties of the MWNTs were measured for the application of field emission display (FED) in near future. Various post treatments were found to improve the field emission property of carbon nanotubes.

  • PDF

고전압 인가 Couette Charger의 유동대전현상에 관한 연구 (A Study on the Streaming Electrification of the Energized Couette Charger)

  • 전상준;정용기;강창구;이강수;곽희로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1848-1850
    • /
    • 1996
  • A Couette Charger was used to simulate streaming electrification process in transformer. This paper describes the electrification characteristics of the energized and unenergized Couette Charger. By applying low frequency and high voltage across the cylinder of the Couette Charger, the measured short circuit current$i_{sc}$) is compared with the measured values of unenergized Couette Charger. As a result, short circuit current was increased with voltage.

  • PDF

교류전압하에서 저압 진공관의 방전현상 (Discharge Phenomena of Low Pressure Vacuum under AC Applied Voltage)

  • 전진;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2301-2302
    • /
    • 2008
  • We experimentally investigated discharge phenomena inside vacuum interrupter at 1 to 20 Torr to simulate the vacuum leakage. We used glass type of vacuum interrupter where the internal pressure and the type of gasses can be varied according to requirement. The experiment is conducted under ac applied voltage and the experimental circuit is constructed to simulate the actual circuit used in cubical type insulated switchgear. We used two types of gases such as air and SF6. The use of glass type vacuum interrupter allowed us to measure discharges occurring in vacuum interrupter optically. We measured and discussed the discharge occurring in both gases with a current transformer and ICCD camera. We also revealed that electromagnetic wave spectra emitted by the discharge have same frequency range for both gasses.

  • PDF

불평형전류 측정에 의한 회전기 열화감시장치 (Deterioration Monitoring Device by Unbalance Current Measurement of Rotating Machines)

  • 박찬용;박대원;류길수;길경석;이강원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.2035-2039
    • /
    • 2008
  • This paper described an on-line condition monitoring device for rotating machines by measurement of unbalance current due to insulation deterioration. The device consists of a zero-phase current transformer (ZCT), a low-noise amplifying circuit, and a microprocessor unit. The prototype device measures current of $500\;{\mu}A\;{\sim}\;30\;mA$ in frequency ranges from 10 Hz to 3 kHz. An application experiment was carried out on 3-phase induction motors and we could measure current changes caused by a short-circuited turn.

  • PDF

Low Frequency Multi-Level Switching Strategy Based on Phase-Shift Control Methods

  • Lee, Sang-Hun;Song, Sung-Geon;Park, Sung-Jun
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권3호
    • /
    • pp.366-371
    • /
    • 2012
  • In this paper, we propose an electric circuit using one common-arm of H-Bridge inverters to reduce the number of switching components in the multi-level inverter combined with H-Bridge inverters and transformers. And furthermore, we suggested a new multi-level PWM inverter using PWM level to reduce THD (Total Harmonic Distortion). We use a phase-shift switching method that has the same rate of usage at each transformer. Also, we test the proposed prototype 9-level inverter to clarify the proposed electric circuit and reasonableness of the control signal for the proposed multi-level PWM inverter.

위상 변위제어기법을 이용한 저주파 다중레벨 스위칭 방식 (Low frequency Multi-level Switching Strategy based on Phase-Shift Control)

  • 우도;문채주;박성준;남해곤;권순재
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.673-676
    • /
    • 2005
  • In this paper, we proposed the electric circuit using one common arm of H-Bridge Inverters to reduce the number of switching component in multi-level inverter combined with H-Bridge Inverters and Transformers. and furthermore we suggested the new multi-level PWM inverter using PWM level to reduce THD(Total Harmonic Distortion). and we used the switching method that can be same rate of usage at each transformer. Also, we tested the proposed prototype 9-level inverter to clarify the proposed electric circuit and reasonableness of control signal for the proposed multi-level PWM inverter.

  • PDF

양방향 풀-브릿지 DC-DC 컨버터를 위한 새로운 소프트 스위칭 기법 (A New Soft Switching Technique for Bi-directional Power Flow, Full-bridge DC-DC Converter)

  • 송유진;박석인;정학근;한수빈;정봉만
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.251-255
    • /
    • 2005
  • This paper proposes a new soft switching technique for a phase-shift controlled bi-directional DC-DC converter. The described converter employs a low profile high frequency transformer and two active full-bridge converters for bidirectional power flow capability. A new soft switching technique is proposed, which guarantees soft switching over wide range (no load to full load) without any additional circuit components. In the proposed switching scheme, the switch pairs in the diagonal position of the converter each are turned on/off simultaneously by the switching signals with a variable duty ratio depending on the phase shift amount, and the converter is operated without freewheeling interval.

  • PDF

인버터 용접기 2차측 출력 전압손실을 보상하는 제어방법 (The Control Method for Output Voltage Compensation on the Secondary of Inverter)

  • 배종일;유치국;주진호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 D
    • /
    • pp.2772-2774
    • /
    • 2003
  • The power source of inverter welder stable power of low voltage and high current. Because if shouldn't be, it is caused to spark between the parent metal and the peak. So that, we designed to be base on high frequency transformer and reactor of DC part. Then, we optimized control of PWM, current rising slant, voltage, current, pulse current and inverter out-put voltage. Also we designed PCB for EMI and noises.

  • PDF

Analysis of an Interleaved Resonant Converter for High Voltage and High Current Applications

  • Lin, Bor-Ren;Chen, Chih-Chieh
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1632-1642
    • /
    • 2014
  • This paper presents an interleaved resonant converter to reduce the voltage stress of power MOSFETs and achieve high circuit efficiency. Two half-bridge converters are connected in series at high voltage side to limit MOSFETs at $V_{in}/2$ voltage stress. Flying capacitor is used between two series half-bridge converters to balance two input capacitor voltages in each switching cycle. Variable switching frequency scheme is used to control the output voltage. The resonant circuit is operated at the inductive load. Thus, the input current of the resonant circuit is lagging to the fundamental input voltage. Power MOSFETs can be turn on under zero voltage switching. Two resonant circuits are connected in parallel to reduce the current stress of transformer windings and rectifier diodes at low voltage side. Interleaved pulse-width modulation is adopted to decrease the output ripple current. Finally, experiments are presented to demonstrate the performance of the proposed converter.

인버터 용접기의 출력 전압제어 및 Art-Work 구현에 관한 연구 (On Study for The Implementation of Art-Work and Output Voltage Control of An Inverter Welder)

  • 배종일;최연욱;김영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1888-1889
    • /
    • 2007
  • The power source of inverter welder stable power of low voltage and high current. Because if shouldn't be, it is caused to spark between the parent metal and the peak. So that, we designed to be base on high frequency transformer and reactor of DC part. Then, we optimized control of PWM, current rising slant, voltage, current, pulse current and 인버터 out-put voltage. Also we designed PCB for EMI and noises.

  • PDF