• Title/Summary/Keyword: low frequency inverter

Search Result 397, Processing Time 0.029 seconds

A Gm-C Filter using CMFF CMOS Inverter-type OTA (CMFF CMOS 인버터 타입 OTA를 이용한 Gm-C 필터 설계)

  • Choi, Moon-Ho;Kim, Yeong-Seuk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.4
    • /
    • pp.267-272
    • /
    • 2010
  • In this paper, a Gm-C LPF utilizing common-mode feedforward (CMFF) CMOS inverter type operational transconductance amplifier (OTA) has been designed and verified by circuit simulations. The CMFF CMOS inverter OTA was optimized for wide input linearity and low current consumption using a standard 0.18 ${\mu}m$ CMOS process; gm of 100 ${\mu}S$ and current of 100 ${\mu}A$ at supplied voltage of 1.3 V. Using this optimized CMFF CMOS inverter type OTA, an elliptic 5th order Gm-C LPF for GPS specifications was designed. Gain and frequency tuning of the LPF was done by changing the internal supply voltages. The designed Gm-C LPF gave pass-band ripple of 1.6 dB, stop-band attenuation of 60.8 dB, current consumption of 0.60 mA at supply voltage of 1.2 V. The gain and frequency characteristics of designed Gm-C LPF was unchanged even though the input common-mode voltage is varied.

A Study on Analysis and Design of HVC Embedded High Frequency Transformer for Microwave Oven (Microwave Oven용 커패시터 내장형 고주파변압기의 해석 및 설계에 관한 연구)

  • 박강희
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.90-94
    • /
    • 2000
  • A conventional power supply to drive a microwave oven has ferro-resonant transformer and high voltage capacitor(HVC). Though it is simple transformer is bulky heavy and has low-efficiency. To improve this defect a high frequency switching inverter-type power supply has been investigated an developed. in recent years. But because of it's additional circuit and devices inverter-type power supply is more expensive than conventional one. In this paper The design procedure of a novel HVC embedded high frequency transformer is proposed for down-sizing and cost reduction. Also transformer equivalent circuit model is derived by FEM analysis and parameter measurements. And the operation of proposed HVC embedded transformer is verified by simulation and experimental results.

  • PDF

A study on the Optimal Pattern for Low Noise PWM Inverter (저 잡음 PWM 인버터를 위한 최적패턴에 관한 연구)

  • Kim, Y.C.;Park, Y.S.;Bae, J.Y.;Woo, J.I.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1063-1066
    • /
    • 1992
  • As the adjustable speed drives by means of PWM inverter are applied to a wider field of industries, the demands for lower acoustic noise caused by modulation is becoming more intense. With the development of high speed power semiconductor device such as the IGBTs, a higher carrier frequency can be adopted to increase the switching frequency to the supersonic range. The optimal magnitude of this signal is determined so that the sideband components near the carrier frequency are minimized

  • PDF

Development of PWM Converter System for Sapphire Silicon Ingot Glowing of 80kW 10kA (사파이어 실리콘 결정 성장용 80kW 10kA PWM 컨버터 시스템 개발)

  • Kim, Min-Huei;Park, Young-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.11
    • /
    • pp.33-41
    • /
    • 2014
  • This paper is research result for a development of sapphire silicon ingot glowing(SSIG) PWM converter system for 80kW 10kA. The system include 3-phase AC-DC diode rectifier of input voltage AC 380V and 60Hz, DC-AC single phase full bridge PWM inverter of high frequency, AC-DC single-phase full wave rectifier using center-tapped of transformer for low voltage 8.0V and large current 10,000A of output specification, tungsten resistor load 0.1[$m{\Omega}$]. PWM switching frequency for IGBT inverter control set 30kHz. The suggested researching contents are designed data sheets of power converter system, PSIM simulation, operating characteristics and analysis results of developed SSIG system. This paper propose

Development of 100kHz 5MVA Inverter Module for Induction Heating (유도가열용 100kHz 5MVA 인버터 모듈 개발)

  • Yoo, Hyo-Yol;Shim, Eun-Yong;Kang, Jae-Bong;Go, Chang-Soon;Choi, Gil-Yong;Kim, Hyoung-Bok
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.287-288
    • /
    • 2010
  • The Induction Heating equipment is widely used for steel plate heating in the surface treatment process of steel industries. In the case of thin steel plate, for high efficiency We need the high frequency induction heating equipment more than 100kHz. But it is difficult to realize the high frequency and high power at the same time. That's why most high frequency equipment more than 100kHz has been imported from advanced Manufacturer. This paper will describe the development of 100kHz/5MVA inverter module for 100kHz/20MVA induction heating. We used the LCL resonance topology and ZVS/ZCS switching technology. And we also developed the low loss gate drive board and plate busbar inverter stack. We proved the performance by various experiment.

  • PDF

A Study on Pulse Power Suppuy for Microwave Oven Using HVC Embedded High Frequency Transformer (HVC 내장형 고주파변압기를 이용한 Microwave Oven용 펄스전원장치에 관한 연구)

  • Park K.H.;Cho J.S.;Jung B.H.;Mok H.S.;Park H.B.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.584-588
    • /
    • 2001
  • A conventional power supply to drive a microwave oven has ferro-resonant transformer and high voltage Capacitor(HVC). Though it is simple, transformer is bulky, heavy and has low-efficiency. To improve this defect a high frequency inverter type power supply has been investigated and developed in recent years. But, because of additional control circuit and switching device, inverter-type power supply is more expensive than conventional one. In this study, A new pulse power supply for Microwave Oven using novel HVC embedded high frequency transformer is proposed for down-sizing, cost reduction, and efficiency emprovement of Inverter type power supply. Also, equivalent circuit model is derived by impedance measurements. And the operation of proposed pulse power supply is verified by simulations and experimental results.

  • PDF

Rubust controller for inverter using CRA (CRA를 이용한 인버터 강인제어기 설계)

  • Lee, Jin-Mok;Park, Ga-Woo;Lee, Jae-Moon;Jung, Hun-Sun;Noh, Se-Jin;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.98-100
    • /
    • 2007
  • This paper proposes a robust digital controller for PWM voltage source inverter using CRA method. The usual inverter controller for the operation of constant voltage and constant frequency consists of a double looped PI controller for the outer voltage controller and the inner current controller, of which the order of characteristic polynomial is high and so the gain tuning is difficult. Considering the limited switching frequency of the devices and sampling frequency of the digital controller, the gain tuning is usually based on the engineering experiences with the try and error method. In this paper, the error-space approach is used to get the system model including the controller with low order, and the characteristic ratio assignment (CRA) method is proposed for the design of robust controller which has the advantage to design the optimal gain to meet the referenced response and overshoot within the limit range. The PSiM simulation and experience results are shown to verify the validity of the proposed controller.

  • PDF

Design of High Frequency Resonant High-tension Transformer in Inverter Type X-Ray Generator (인버터식 X선발생장치용 고주파 공진형 고압변압기 등의 설계)

  • Lee, Seong-Kil;Choi, Sung-Kwan
    • Journal of radiological science and technology
    • /
    • v.24 no.2
    • /
    • pp.5-11
    • /
    • 2001
  • Most of X-ray generator had used rectifier type transformer with high tension generator which is supplied in a clinical diagnosis. Because the ripple rate of tube voltage is high, X-ray generating efficiency is very low. In these days, high tension generator for inverter type X-ray generator is being supplied from a broad which uses semi-conductor switching element for the electric power that have a high speed switching ability to solve these problem. But, semi-conductor element with large capacity is used with X-ray tube's large consumption power and diffusion is difficult in the small size hospital because production cost is going up by doing digital control through DSP. Therefore, this paper designed and manufactured CR type voltage divider for feedback control of tube voltage with high frequency resonance type inverter and for high tension transformer with high frequency. It was to make economical diffusion type X-ray generator which has wide output voltage and load extent. It was preyed that the X-ray generator had the stability of X-ray tube's output characteristics.

  • PDF

The Characteristics of Control Scheme and Inner Feedback Control with HC of Current-Controlled PWM Inverter (전류제어 PWM인버터의 HC에 대한 제어방식과 내부 피이드백제어의 특성)

  • 정동화;배진호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.9
    • /
    • pp.1031-1041
    • /
    • 1992
  • Existing current-controlled inverters with hysteresis controller (HC) result in the dependence of the inverter on its load characteristics, poor inverter utilization due to too much or too little supply voltage, and the current error in the hysteresis band(HB) which causes deterioration of operation of the supplied motor. In this paper, techniques and results of modeling the operation of current-controlled three phase power inverter with HC are presented. Four symmetrical control schemes are considered: the so called three independent control, three semi-dependent control(a), three semi-dependent control(b) and three dependent control each using three current controller. The dependence of the inverter on its load has been studied. To overcome this difficulty, an inner feedback control has been introduced and optimum parameter has been determined. With the addition of an inner feedback control, adjustment of the switching frequency to a desired value is possible. Also, this modification improves operating characteristics of inverter by enforcing a switching pattern of low dependence on the load, resulting in significantly improved quality of the output current.

  • PDF

Open Switch Fault Tolerance Control of Active NPC Inverters With HF/LF Modulation (HF/LF 변조를 적용한 Active NPC 인버터의 개방 고장 허용 제어)

  • Jung, Won Seok;Kim, Ye-Ji;Kim, Seok-Min;Lee, Kyo-Beum
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.170-177
    • /
    • 2020
  • This paper presents an open-fault tolerance control method for active neutral point clamped (ANPC) inverter with high frequency/low frequency (HF/LF) modulation. By applying the ANPC inverter with SiC MOSFETs and Si IGBTs, the system efficiency and performance can be improved compared to a Si-based inverter. HF/LF modulation is used for a megawatt-scale inverter to minimize the commutation loop. The open-switch failure in megawatt-scale inverter causes severe damage to load and huge expenses when the inverter has been shut-down. The proposed tolerance control of open-switch failure provides continuous operation and improved reliability to the ANPC inverter. The effectiveness of the proposed fault tolerance control is verified by simulation results.