• Title/Summary/Keyword: low energy consumption

Search Result 1,394, Processing Time 0.033 seconds

Localized Path Selection Algorithm for Energy Efficiency and Prolonging Lifetime in Ad-Hoc Networks (에드 혹 네트워크에서 에너지 효율성과 네트워크 수명 연장을 위한 지역적 경로 선택 알고리즘)

  • Lee, Ju-Young
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.6
    • /
    • pp.65-72
    • /
    • 2010
  • In ad-hoc network, the technique to efficiently consume the limited amounts of energy is an important issue since the wireless terminal node is operated on batteries as their energy resource. In order to extend the system lifetime, through a balanced energy consumption, we must delay the situation in which a particular terminal node's energy is depleted and results in system disconnection. Also, the link, which has low reliability due to the mobility of the node, should be avoided considering the key element when setting up the route. The proposed CMLR method in this paper enables to increase the efficiency of energy consumption with a new cost function considering the residue energy of node, error rate of link, and transmission energy consumption. This method is extending the network lifetime and increasing the energy efficiency by compromising the value between the minimization of the transmission energy consumption and maximization of the node's lifetime. Through the simulations the proposed CMLR algorithm was verified by showing better performance over the conventional methods in terms of network lifetime and path efficiency.

Routing Protocol based on Connectivity Degree and Energy Weight (연결도와 에너지 가중치 기반의 라우팅 프로토콜)

  • Jeong, Yoon-Su
    • Journal of Convergence Society for SMB
    • /
    • v.4 no.1
    • /
    • pp.7-15
    • /
    • 2014
  • In this paper, we propose an efficient routing protocol to achieve an optimal route searching process of the network lifetime by balancing power consumption per node. The proposed protocols aim at finding energy-efficient paths at low protocol power. In our protocol, each intermediate node keeps power level and branch number of child nodes and it transmits the data the nearest neighbor node. Our protocol may minimize the energy consumption at each node, thus prolong the lifetime of the system regardless of the location of the sink outside or inside the cluster. In the proposed protocol for inter-cluster communication, a cluster head chooses a relay node from its adjacent cluster heads according to the node's residual energy and its distance to the base station. Simulation results show that proposed protocol successfully balances the energy consumption over the network, and achieves a remarkable network lifetime improvement as highly as 7.5%.

  • PDF

A Detailed Analysis of the Part Load Ratio and Cooling Energy Characteristics of Chiller Operation in an Office Building (사무소 건물에서 냉동기의 부분부하율 및 냉방 에너지 성능 특성 분석)

  • Seo, Byeong-Mo;Yu, Byeong-Ho;Lee, Kwang-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.11
    • /
    • pp.567-573
    • /
    • 2015
  • Commercial buildings account for significant portions of the total building energy in Korea, and thus, a variety of research on chiller operation has been carried out. However, most of the studies were carried out on the chiller itself, i.e., the part load ratio characteristics and the corresponding electricity energy consumption patterns were not analyzed in existing studies. In this study, the part load ratio and the operating characteristics of the vapor compression chiller were analyzed within an office building equipped with the conventional variable air volume system. As a result, significant portions of total operating hours, cooling load, and energy consumption turned out to be in the part load ratio range of 0 through 50%. Thus, energy consumption was significantly affected by the chiller COP at low part load conditions, indicating that chiller operation at the part load is an important factor in commercial buildings.

Optimal Driving Mode Analysis for Reducing Energy Consumption in Electric Multiple Unit (전동열차의 주행에너지 소비를 절감하는 운전모드 해석)

  • Kim Chi Tae;Kim Dong Hwan;Park Young Il;Han Sung Ho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.1
    • /
    • pp.174-183
    • /
    • 2005
  • A train driving requires to n the fixed distance within given time, and it is desirable to consume low energy if necessary. Reducing energy consumption depends on the train operation modes by either manual or automatic operation. In this article, an operation to reduce energy consumption by changing modes of train operation by a driver without changing the train operation requirement is investigated. The powering model, braking model and consumed energy calculation model are developed, then simulated by using a Matlab software. The accuracy of the train dynamic model established by the simulations is verified by comparing with the real experimental data. Several simulations by various operations in the real track are executed, then the desirable pattern of train driving is found.

Investigation, analysis and study for urban transit's driving energy efficiency (도시철도 운전에너지 효율화를 위한 조사 분석 연구)

  • Kim, Young-Kyu;Park, Se-Young;Park, Young-Seok;Chung, Il-Bong;Han, Moon-Seob
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.612-618
    • /
    • 2009
  • Recently the roles of railways about the prevention of global warming caused by greenhouse gases and for low carbon green growth are larger than ever. And the railroad-related research institutions have been active in researching for energy conservation. Especially the urban railroad has been emerged as the best means of transportation compared to the general public transportation systems in punctuality, stability, ecology and etc. In operating the urban railroad system there are various ways for energy savings. In the larger category, One is the hardware aspect according to the structure of the vehicle and the development of control systems. The other is the software aspect which efficient train operation can be made through control of driving patterns and driving diagram. In this paper, there is sense to analyze the result in verifying expectation relation with variable and the use of electric power on this after selecting main variables that can influence to the energy of the train operation in the software aspect. First, after collecting the basic data related to operation(train speed, operating hours, power consumption, the position of stopping station, electrical power system etc.) and according to this, investigating the consumption of the energy of the operation, in the side of energy consumption deducing and analyzing problem, this will be found solutions.

  • PDF

Low-Power Operation Method of Thermal-Energy Harvesting Sensor Circuit (Thermal Energy Harvesting용 센서회로의 저전력 구동 방법)

  • Nam, Hyun Kyung;Pham, Van Khoa;Tran, Bao Son;Nguyen, Van Tien;Min, Kyeong-Sik
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.842-845
    • /
    • 2018
  • In this paper, we propose low-power operational methods for thermal-energy-harvesting sensor circuits. Here, the amount of harvested current has been measured as low as 8uA. However the DC power consumption of the sensor circuit is known to consume much larger than 8uA. Thus, We propose the hardware-based power gating and software-based active/sleep timing control schemes, respectively, for controlling the power consumption of sensor circuit. In the hardware-based power gating scheme, if the ratio of Toff/Ton is larger than 22, the sensor can consume less than 8uA. For the software-based active/sleep control scheme, if the ratio of Tslp/Tact is larger than 3, we can suppress the current consumption below 8uA. The hardware-based and software-based schemes proposed in this paper would be helpful in various applications of energy-harvesting sensor circuits, where the power consumption is limited by an amount of harvested energy.

New Drowsy Cashing Method by Using Way-Line Prediction Unit for Low Power Cache (저전력 캐쉬를 위한 웨이-라인 예측 유닛을 이용한 새로운 드로시 캐싱 기법)

  • Lee, Jung-Hoon
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.10 no.2
    • /
    • pp.74-79
    • /
    • 2011
  • The goal of this research is to reduce dynamic and static power consumption for a low power cache system. The proposed cache can achieve a low power consumption by using a drowsy and a way prediction mechanism. For reducing the static power, the drowsy technique is used at 4-way set associative cache. And for reducing the dynamic energy, one among four ways is selectively accessed on the basis of information in the Way-Line Prediction Unit (WLPU). This prediction mechanism does not introduce any additional delay though prediction misses are occurred. The WLPU can effectively reduce the performance overhead of the conventional drowsy caching by waking only a drowsy cache line and one way in advance. Our results show that the proposed cache can reduce the power consumption by about 40% compared with the 4-way drowsy cache.

  • PDF

A Study on Evaluation of the Building Energy Rating depending on the Thermal Performance of Balcony Window with Low-E glazing (로이유리 발코니 창호의 단열성능에 따른 공동주택 건축물 에너지효율등급 평가 연구)

  • Lee, Na-Eun;Ahn, Byung-Lip;Jang, Cheol-Yong;Leigh, Seung-Bok
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.2
    • /
    • pp.58-63
    • /
    • 2012
  • As the exterior of building has been considered one of th important parts, the use of glass that is suitable to express various appearances gets raised. However, windows have 6~7times lower insulating performance than insulated walls. Lately, highly efficient windows are required as the needs for reduction of energy consumption come to the force. Therefore, Nowadays more people use cooling systems in summer, more the use of Low-E glazing is increasing. Because it is good to block Solar Radiant Energy which can cause much of heat loss while cooling system is working. This study measures U-value of the double Low-E glazing window and commonly used single Low-E glazing window. And then the effect of each window on the efficiency rating has been analyzed applying to the certification system of the building energy efficiency rating which has implemented.

Development of control and monitoring board for building energy saving valve (빌딩 에너지 절감 밸브용 제어 및 감시 보드 개발)

  • Oh, Jin-Seok;Kang, Young-Min;Jang, Jae-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.6
    • /
    • pp.895-902
    • /
    • 2018
  • Energy consumption in buildings is close to 40% of the total national energy consumption in developed countries such as US and Japan, and Korea accounts for 24% of total energy consumption. In buildings, HVAC can't freely control the cooling flow rate according to the required calorie, so energy is not used efficiently. Therefore, by using the energy saving valve, the flow rate can be controlled by the required amount of heat and the energy can be saved. In this paper, we define basic conditions and develop control and monitoring boards for building energy saving valves based on PIC processor with low power and high cost-effectiveness. The designed board displays and transmits in real time information about two temperature values, flow values and calculated calories for temperature difference measurement. The developed board will be useful for real - time monitoring of the state of the valve in the future and development of the valve for the offshore.

Low-power Buffer Cache Management for Mixed HDD and SSD Storage Systems (HDD와 SSD의 혼합형 저장 시스템을 위한 절전형 버퍼 캐쉬 관리)

  • Kang, Hyo-Jung;Park, Jun-Seok;Koh, Kern;Bahn, Hyo-Kyung
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.4
    • /
    • pp.462-466
    • /
    • 2010
  • A new buffer cache management scheme that aims at reducing power consumption in mixed HDD and NAND flash memory storage systems is presented. The proposed scheme reduces power consumption by considering different energy-consumption rate of storage devices, I/O operation type (read or write), and reference potential of cached blocks in terms of both recency and frequency. Simulation shows that the proposed scheme reduces power consumption by 18.0% on average and up to 58.9%.