• Title/Summary/Keyword: low doses

Search Result 755, Processing Time 0.033 seconds

Successful engraftment after infusion of multiple low doses of CD34+ cells from a poorly matched sibling donor in a patient with severe aplastic anemia

  • Kum, Chang Dae;Lee, Mi Jin;Park, Jun Eun
    • Journal of Yeungnam Medical Science
    • /
    • v.36 no.2
    • /
    • pp.148-151
    • /
    • 2019
  • The dose of CD34+ cells is known to influence the outcome of allogeneic peripheral blood stem cell (PBSC) and/or T-cell-depleted transplantation. A previous study proposed that $2{\times}10^6\;CD34+\;cells/kg$ is the ideal minimum dose for allogeneic transplantation, although lower doses did not preclude successful therapy. In the case we present here, CD34+ cells were collected from a matched sibling donor on the day of allogeneic hematopoietic stem cell transplantation; however, the number of cells was not sufficient for transplantation. Consequently, PBSCs were collected three additional times and were infused along with cord blood cells from the donor that were cryopreserved at birth. The cumulative dose of total nuclear cells and CD34+ cells was $15.9{\times}10^8\;cells/kg$ and $0.95{\times}10^6\;cells/kg$, respectively. White blood cells from this patient were engrafted on day 12. In summary, we report successful engraftment after infusion of multiple low doses of CD34+ cells in a patient with severe aplastic anemia.

Differential Expression of Th1- and Th2- Type Cytokines in Peripheral Blood Mononuclear Cells of Murrah Buffalo (Bubalus Bubalis) on TLR2 Induction by B. Subtilis Peptidoglycan

  • Shah, Syed M.;Ravi Kumar, G.V.P.P.S.;Brah, G.S.;Santra, Lakshman;Pawar, Hitesh
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.25 no.7
    • /
    • pp.1021-1028
    • /
    • 2012
  • Peripheral blood mononuclear cells (PBMCs) discriminate microbial pathogens and induce T-cell responses of appropriate effector phenotype accordingly. Toll-like receptors (TLRs), in part, mediate this microbial recognition and differentiation while the development of T-cell effector functions critically depends on the release of Th1- or Th2- type cytokines. In the present study, buffalo PBMCs were stimulated under in vitro culture conditions by Bacillus subtilis cell wall petidoglycan, a TLR2 ligand, in a dose- and time- dependent manner. The expression of TLR2 as well as the subsequent differential induction of the Th1 and Th2 type cytokines was measured. Stimulation was analyzed across five doses of peptidoglycan ($10{\mu}g/ml$, $20{\mu}g/ml$, $30{\mu}g/ml$, $40{\mu}g/ml$ and $50{\mu}g/ml$) for 3 h, 12 h, 24 h and 36 h incubation periods. We observed the induction of TLR2 expression in a dose- and time-dependent manner and the peptidoglycan induced tolerance beyond $30{\mu}g/ml$ dose at all incubation periods. The correlation between peptidoglycan stimulation and TLR2 induction was found positive at all doses and for all incubation periods. Increased production of all the cytokines was observed at low doses for 3 h incubation, but the expression of IL-4 was relatively higher than IL-12 at the higher antigen doses, indicating tailoring towards Th2 response. At 12 h incubation, there was a pronounced decrease in IL-4 and IL-10 expression relative to IL-12 in a dose- dependent manner, indicating skewing to Th1 polarization. The expression of IL-12 was highest for all doses across all the incubation intervals at 24 h incubation, indicating Th1 polarization. The relative expression of TNF-${\alpha}$ and IFN-${\gamma}$ was also higher while that of IL-4 and IL-10 showed a decrease. For 36 h incubation, at low doses, relative increase in the expression of IL-4 and IL-10 was observed which decreased at higher doses, as did the expression of all other cytokines. The exhaustion of cytokine production at 36 h indicated that PBMCs became refractory to further stimulation. It can be concluded from this study that the cytokine response to sPGN initially was of Th2 type which skews, more pronouncedly, to Th1 type with time till the cells become refractory to further stimulation.

Surface modification and induced ultra high surface hardness by nitrogen ion implantation of low alloy steel

  • Olofinjana, A.O.;Bell, J.M.;Chen, Z.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.157-158
    • /
    • 2002
  • A surface hardenable low alloy carbon steel was implanted with medium energy (20 - 50KeV) $N_2^+$ ions to produced a modified hardened surface. The implantation conditions were varied and are given in several doses. The surface hardness of treated and untreated steels were measured using depth sensing ultra micro indentation system (UMIS). It is shown that the hardness of nitrogen ion implanted steels varied from 20 to 50GPa depending on the implantation conditions and the doses of implantation. The structure of the modified surfaces was examined by X-ray photoelectron spectroscopy (XPS). It was found that the high hardness on the implanted surfaces was as a result of formation of non-equilibrium nitrides. High-resolution XPS studies indicated that the nitride formers were essentially C and Si from the alloy steel. The result suggests that the ion implantation provided the conditions for a preferential formation of C and Si nitrides. The combination of evidences from nano-indentation and XPS, provided a strong evidence for the existence of $sp^3$ type of bonding in a suspected $(C,Si)_xN_y$ stoichiometry. The formation of ultra hard surface from relatively cheap low alloy steel has significant implication for wear resistance implanted low alloy steels.

  • PDF

Absorbed Dose in the Full-mouth Periapical Radiography, Panoramic Radiography, and Zonography (전악치근단방사선사진촬영, 파노라마방사선사진촬영 및 협각단층촬영시의 흡수선량)

  • Choi Soon-Chul;Choi Hang-Moon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.255-260
    • /
    • 1999
  • Purpose: The objective of this study was to evaluate the possibility of substitution of the zonography for the full-mouth periapical radiography in aspect of radiation protection. Materials and Methods: Rando phantom and LiF TLD chips were used for dosimetry. The absorbed doses at brain, skin above the TMJ. parotid gland. bone marrow in the mandibular body. and thyroid gland during the full-mouth periapical radiography. panoramic radiography. and zonography were measured. Resul ts: From the zonography. the absorbed doses to the brain. the skin over the TMJ. and the parotid gland were relatively high. but the absorbed doses to the bone marrow in the mandibular body and. especially. the thyroid gland were very low. Conclusion: The zonography can be an alternative to the full-mouth periapical radiography in aspect of radiation protection.

  • PDF

High Dose $^{60}Co\;{\gamma}$-Ray Irradiation of W/GaN Schottky Diodes

  • Kim, Jihyun;Ren, F.;Schoenfeld, D.;Pearton, S.J.;Baca, A.G.;Briggs, R.D.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.4 no.2
    • /
    • pp.124-127
    • /
    • 2004
  • W/n-GaN Schottky diodes were irradiated with $^{60}Co\;{\gamma}-rays$ to doses up to 315Mrad. The barrier height obtained from current-voltage (I-V) measurements showed minimal change from its estimated initial value of ${\sim}0.4eV$ over this dose range, though both forward and reverse I-V characteristics show evidence of defect center introduction at doses as low as 150 Mrad. Post irradiation annealing at $500^{\circ}C$ increased the reverse leakage current, suggesting migration and complexing of defects. The W/GaN interface is stable to high dose of ${\gamma}-rays$, but Au/Ti overlayers employed for reducing contact sheet resistance suffer from adhesion problems at the highest doses.

Quantitative and Qualitative Extrapolation of Carcinogenesis Between Species

  • Gold Lois Swirsky;Manley Neela B.;Ames Bruce N.
    • 대한예방의학회:학술대회논문집
    • /
    • 1994.02a
    • /
    • pp.431-438
    • /
    • 1994
  • As currently conducted, standard rodent bioassays do not provide sufficient information to assess carcinogenic risk to humans at doses thousands of times below the maximum tolerated dose. Recent analyses indicate that measures of carcinogenic potency from these tests are restricted to a narrow range about the maximum tolerated dose and that information on shape of the dose-response is limited in experiments with only two doses and a control. Extrapolation from high to low doses should be based on an understanding of the mechanisms of carcinogenesis. We have postulated that administration of the maximum tolerated dose can increase mitogenesis which, in turn. increases rates of mutagenesis and, thus, carcinogenesis. The animal data are consistent with this mechanism, because about half of all chemicals tested are indeed rodent carcinogens, and about 40% of the positives are not detectably mutagenic. Thus, at low doses where cell killing does not occur, the hazards to humans of rodent carcinogens may be much lower than commonly assumed. In contrast, for high-dose exposures in the workplace, assessment of hazard requires comparatively little extrapolation. Nevertheless. permitted workplace exposures are sometimes close to the tumorigenic dose-rate in animal tests. Regulatory policy to prevent human cancer has primarily addressed synthetic chemicals, yet similar proportions of natural chemicals and synthetic chemicals test positive in rodent studies as expected from an understanding of toxicological defenses, and the vast proportion of human exposures are to natural chemicals. Thus, human exposures to rodent carcinogens are common. The natural chemicals are the control to evaluate regulatory strategies, and the possible hazards from synthetic chemicals should be compared to the possible hazards from natural chemicals. Qualitative extrapolation of the carcinogenic response between species has been investigated by comparing two closely related species: rats and mice. Overall predictive values provide moderate confidence in interspecies extrapolation; however, knowing that a chemical is positive at any site in one species gives only about a 50% chance that it will be positive at the same site in the other species.

  • PDF

Observation of Back Scattering and Exposure-Factors (후방산란(後方散亂)과 노출배수(露出倍數)에 관(關)한 검토(檢討))

  • Huh, Joon;Kim, Chang-Kyun;Kang, Hong-Seok;Lee, Sun-Sook;Lee, Jwa-Ryong;Youn, Chul-Ho
    • Journal of radiological science and technology
    • /
    • v.5 no.1
    • /
    • pp.15-19
    • /
    • 1982
  • Authors made an experiment to know the relation of surface doses and multiple factors of exposure by using grids, fields, tube voltages objects and distances and obtained the results as follows: 1. Surface doses were increased in proportion to the thickness of objects. 2. Surface doses were more influenced when irradiated fields were small and tube voltages were low. 3. Surface doses were a logarthmic proportion to the focus-object distance. 4. Multiple factors of exposure by using grid were under the control of the thickness of objects, irradiated fields and tube voltages but the relation of them were not fixed.

  • PDF

Radon and thoron concentrations inside ancient Egyptian tombs at Saqqara region: Time-resolved and seasonal variation measurements

  • Salama, E.;Ehab, M.;Ruhm, W.
    • Nuclear Engineering and Technology
    • /
    • v.50 no.6
    • /
    • pp.950-956
    • /
    • 2018
  • For complete assessment of inhalation doses of radon and its progeny inside the three main ancient Egyptian tombs in Saqqara, seasonal radon concentrations have been measured by using a new electronic device that allows for measurement of real-time-resolved radon concentrations. Measurements were complemented by very fast measurements of thoron concentrations, which turned out to be low. Based on these measurements, annual residence time inside these tombs and the newest International Commission on Radiological Protection-recommended radon dose conversion coefficients or seasonal effective doses were calculated. The results indicate that workers receive highest annual effective doses of up to 140 mSv, which exceeds the annual limit of 20 mSv, whereas lower values up to 15 mSv are received by guides. In contrast, much lower doses were obtained for one-time visitors of the investigated tombs. The obtained results are somewhat different but still consistent with those previously obtained by means of fixed passive dose meters at some of the investigated places. This indicates that reasonable estimates of the effective dose of radon can be also obtained from short-term radon measurements carried out only twice a year (summer and winter season). Increasing the ventilation, minimizing the working times, etc., are highly recommended to reduce the annual effective dose.

Effects of Cinnamon Supplementation on Lipid Profile: A Systematic Review and Meta-Analysis of Randomized Controlled Trials

  • Hawal Lateef Fateh;Saman M. Amin
    • Clinical Nutrition Research
    • /
    • v.13 no.1
    • /
    • pp.74-87
    • /
    • 2024
  • Since the effects of cinnamon supplementation on lipid profiles are still controversial, this study conducted a meta-analysis of randomized controlled trials to assess the effect of cinnamon supplementation on lipid profiles. The study was designed and conducted according to the guidelines of the 2020 preferred reporting items for systematic reviews and meta-analysis (PRISMA) statements. A systematic and comprehensive search was performed in several databases from inception up to 11 November 2023. The meta-analysis on the impact of Cinnamon on lipid profiles indicates a non-significant overall effect on low-density lipoprotein (weighted mean differences [WMD], -2.48; 95% confidence interval [CI], -9.70, 4.72). However, significant reductions are seen with doses < 500 mg/day (-10.26), and non-significant increases with doses ≥ 500 mg/day (1.18). The overall effect on high-density lipoprotein is non-significant (WMD, 3.97; 95% CI, -7.877, 15.831), showing varying responses at different doses. Triglycerides exhibit a significant overall reduction (WMD, -6.88; 95% CI, -12.62, -1.15), particularly in the < 500 mg/day group. The overall effect on cholesterol is non-significant (WMD, -4.314; 95% CI, -15.011, 6.384), with diverse responses at different doses. High heterogeneity underlines the importance of standardized study designs and further exploration of dosage-specific effects. Findings from this study suggest that cinnamon supplements might be beneficial to modulate the blood lipid profile.

DISTRIBUTION OF ABSORBED DOSES TO THE IMPORTANT ORGANS OF HEAD AND NECK REGION IN PANORAMIC RADIOGRAPHY (파노라마 촬영시 두경부 주요기관에 대한 흡수선량 분포)

  • Kim Byeong Sam;Choi Karp Shik;Kim Chin Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.2
    • /
    • pp.253-264
    • /
    • 1990
  • The purpose of this study was to estimate the distribution of absorbed doses of each important organs of head and neck region in panoramic radiography. Radiation dosimetry at internal anatomic sites and skin surfaces of phantom (RT-210 Humanoid Head & Neck Section/sup R/) was performed with lithium fluoride (TLD-100/sup R/) thermoluminescent dosimeters according to change of kilovoltage (65kVp, 75kVp and 85kVp) with 4 miliamperage and 20 second exposure time. The results obtained were as follows; Radiation absorbed doses of internal anatomic sites were presented the highest doses of 1.04 mGy, 1.065 mGy and 2.09 mGy in nasopharynx, relatively high doses of 0.525 mGy, 0.59 mGy and 1.108 mGy in deep lobe of parotid gland, 0.481 mGy, 0.68 mGy and 1.191 mGy in submandibular gland. But there were comparatively low doses of 0.172 mGy and 0.128 mGy in eyes and thyroid gland that absorbed dose was estimated at 85kVp. Radiation absorbed doses of skin surfaces were presented the highest doses of 1. 263 mGy, 1.538 mGy and 2.952 mGy in back side of first cervical vertebra and relatively high doses of 0.267 mGy, 0.401 mGy and 0.481 mGy in parotid gland. But there were comparatively low doses of 0.057 mGy, 0.068 mGy and 0.081 mGy in philtrum and 0.059 mGy in middle portion of chin that absorbed dose was estimated at 85kVp. According to increase of kilovoltage, the radiation absorbed doses were increased 1.1 times when kilovolt age changes from 65kVp to 75kVp and 1.9 times when kilovolt age changes from 75kVp to 85kVp at internal anatomic sites. According to increase of kilovoltage, the radiation absorbed doses were increased 1.3 times when kilovolt age changes from 65kVp to 75kVp and 1.6 times when kilovoltage changes from 75kVp to 85kVp at skin surfaces.

  • PDF