치과방사선검사에서 방사선방어용구 사용 전, 후의 유효선량에 대한 평가 (Evaluation of effective dose in panorama, cone beam CT and the usefulness of x-ray protective)

  • 김재인;최원근;이소라;이정화;이관섭
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.15-22
    • /
    • 2012
  • The purpose of this study was to measure the absorbed dose and calculate the effective dose for cone beam computed tomography (CBCT) and panorama units and to estimate usefulness of x-ray protective. Rando phantom and glass dosimeters were used for dosimetry. The absorbed doses were measured at 15 organs and 14 remainder from correspond to ICRP 2007 recommendations. The absorbed dose was highest in salivary glands as measured CBCT 2.420mGy, panorama 0.307mGy. Absorbed dose in another organs were high in order of thyroid, brain, skin, esophagus. The effective dose was CBCT 0.100mSv, panorama 0.011mSv and effective dose of panorama was higher than that of CBCT by 10 times. In case of wearing x-ray protective, reducing effective dose of CBCT by 0.066mSv (66%) and panorama by 0.008mSv (72%). Effective dose were reduced by radiological shielding but it needs further optimization studies, where dosimetric data are analyzed in combination with image quality with keep the patients' exposure as low as possible.

  • PDF

인버터방식의 고전압 발생장치를 이용한 의료용 X선 기기의 특성평가 (Characteristic Evaluation of Medical X-Ray Using High-Voltage Generator with Inverter System)

  • 김영표;천민우;박용필
    • 한국전기전자재료학회논문지
    • /
    • 제24권1호
    • /
    • pp.36-41
    • /
    • 2011
  • Medical X-ray has been brought many changes according to the rapid development of high technology. Especially, for high-voltage generator which is the most important in X-ray generation the traditional way is to use high-voltage electric transformers primarily. However, since it is large and heavy and the ripple rate of DC high-voltage applied to X-ray tube is too big, it has a disadvantage of low X-ray production efficiency. To solve these problems, the studies about high-voltage power supply are now proceeding. At present, the high-voltage generator that generates high-voltage by making high frequency using inverter control circuit consisting of semiconductor device is mainly used. High-voltage generator using inverter has advantages in the diagnosis using X-ray including high performance with short-term use, miniaturization of power supply and ripple reduction. In this study, the X-ray high-voltage device with inverter type using pulse width modulation scheme to the control of tube voltage and tube current was designed and produced. For performance evaluation of produced device, the control signal analysis, irradiation dose change and beam quality depending on the load variation of tube voltage and tube current were evaluated.

Study on Electrical Properties of X-ray Sensor Based on CsI:Na-Selenium Film

  • Park Ji-Koon;Kang Sang-Sik;Lee Dong-Gil;Choi Jang-Yong;Kim Jae-Hyung;Nam Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • 제4권3호
    • /
    • pp.10-14
    • /
    • 2003
  • In this paper, we have introduced the x-ray detector built with a CsI:Na scintillation layer deposited on amorphous selenium. To determine the thickness of the CsI:Na layer, we have estimated the transmission spectra and the absorption of continuous x-rays in diagnostic range by using computer simulation (MCNP 4C). A x-ray detector with 65 ${\mu}m$-CsI:Na/30 ${\mu}m$-Se layer has been fabricated by a thermal evaporation technique. SEM and PL measurements have been performed. The dark current and x-ray sensitivity of the fabricated detector has been compared with that of the conventional a-Se detector with 100 ${\mu}m$ thickness. Experimental results show that both detectors exhibit a similar dark current, which was of a low value below $400 pA/cm^2$ at 10 V/${\mu}m$. However, the CsI:Na-Se detector indicates high x-ray sensitivity, roughly 1.3 times that of a conventional a-Se detector. Furthermore, a CsI:Na-Se detector with an aluminium reflective layer shows a 1.8 times higher x-ray sensitivity than an a-Se detector. The hybrid type detector proposed in this work exhibits a low dark current and high x-ray sensitivity, and, in particular, excellent linearity to the x-ray exposure dose.

보급형 인버터식 X선발생장치의 특성에 관한 연구 (A Study on the Characteristics of Inverter Type X-Ray Genertator)

  • 박수강
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.26-29
    • /
    • 2000
  • The conventional types of X-ray generators were bulky in physical size and heavy in weight and the control accuracies of the output voltages were not always satisfacotry. The high frequency switching inverter and converter technology on power conversion and control systems have been greatly closed up introducing power semiconducot devices. To decreasing the volume and the weight of high voltage transformer and to stabilize ripple. In this paper the newly developed x-ray generator in a low cost using duty modulation PWM inverter. This system verify improved performance by stabilize ripple of X-ray tube voltage and compared the reproducibility linearity and dose in single phase three phase and PSU.

  • PDF

X선조사(線照射)에 의한 절연유(絶緣油)의 도전특성(導電特性)에 관한 연구(硏究) (A Study on Conductivity Characteristics of X-ray Irradiated Insulating Oil)

  • 김영일;이덕출;정연택
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제10권1호
    • /
    • pp.75-83
    • /
    • 1987
  • The insulating oil used for X-ray tube housing were degraded by X-ray irrdiation, high temperature and high anode voltage for normal operation. This study was measured the conduction current-X-ray dose, heating degradation, time, temperature and electric field characteristics and the dependense of electrode materials and gap length in the X-ray irradiatied insulating oil under of D.C voltage. The obtained results can be summarized as following. 1. The conduction current of X-ray irradiated insulating oil is more about $2.5{\sim}3$ times as large as than that of non x-ray irradiated, and is become saturation phenomena after some degree. 2. The conduction current of many times heating x-ray irradiated insulating oil is more than that of a few times heating. 3. The higher temperature x-ray irradiated insulating oil is increased, the more conduction current, and that is increased about ten times as large as when it's temperatures is increased to $80^{\circ}C\;at\;30^{\circ}C$, twenty five times at $100^{\circ}C$. 4. The dependence of electrode materials is appeared at the low electric field, and the small gap length with Fe > Cu > Al. 5. The low electric field than 3000 v/cm is appeared Ohm's law region, and the high is become saturation region at the I-E characteristics. 6. The larger gap length is become, the more conduction current is increased at the same electric field.

  • PDF

휴대용 검출기의 방사선 고감도 검출을 위한 SiPM 특성 분석 (Characteristics Analysis of SiPM for Detection of High Sensitivity of Portable Detectors)

  • 강병욱;유선국
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.897-902
    • /
    • 2023
  • 본 논문에서는 휴대용 X-ray 검출기의 방사선 고감도 검출에 대한 실현 가능 여부를 확인하기 위한 SiPM의 특성 분석을 목적으로 한다. 휴대용 X-ray 검출기는 환자의 위치에 빠르게 접근하여 실시간 이미지를 획득함으로써 의사들은 신속하게 진단을 수행할 수 있는 장점이 있지만 이러한 이동성은 선량 감지의 어려움을 동반한다. 기존 검출기에서는 SiPM을 X-ray Trigger를 판별하는 단순한 용도로 사용하고 있다. SiPM을 통한 X-ray의 고감도 검출 가능 여부를 확인하기 위해 7종의 SiPM Sensor를 비교 선정하고 특성 분석을 진행하였다. 최종 시험에 사용한 SiPM은 10 nGy 수준의 극저선량 조사 조건에서 Signal 구분이 가능하며, 관전압에 따라 Signal 상승곡선의 기울기가 변하는 것이 확인되었다. X-ray 선량에 따라 SiPM의 signal level 및 지속시간이 변화되는 특성을 이용한 고감도 측정이 가능할 것으로 보인다.

Co$^{60}\gamma$.gamma.선이 저밀도 폴리에티렌의 각상에 미치는 조사효과 (Radiation Effect to Each Phase of Morphology on a Low Density Polyethylene Irradiated to $C_0^{60}\gamma$. ray)

  • 김봉흡;강도열;김재환
    • 전기의세계
    • /
    • 제23권5호
    • /
    • pp.54-60
    • /
    • 1974
  • Proposals were mode on how to differentiate radiation effects in morphological phases of polyethylene and discussions were developed with the results obtained on a low density polyethylene, SOCAREX, specified by number average molecular weight; overbar Mn=5,400, density; 0.92, and degree of branch; 3.4/100 carbon atom, which was irradiated to Co$^{60}$ .gamma. ray at the dose rate of 0.5 Mrad/hr in ambient temperature under the pressure of 10$^{-5}$ Torr. or 1 atm. respectively. The effect to crystalline phase in possibly deduced from dose dependent variation of relative area between (110) and (200) peaks on X ray diffraction spectrum and that, the effects to amorphous phase can be understood through dose dependent relaxation behaviours of .betha. peak on internal friction characteristics of the specimen. The results obtained thus far indicate that, in crystalline phase, relative crystallinity shows a rather rapid decrease up to 20 Mrad with increasing dose, however, little change of crystallinity can be observed in the region between 20-200 Mrad, and degradation appears to be more predominant than crosslinking up to 60 Mrad. While in amorphous phase the indication also shows that degradation is only predominant up to 20 Mrad. Furthermore several correlations can be seen with amenable explanation between dose dependent behaviours observed in both phases.

  • PDF

고에너지 광자선치료에서 고정판 흡수물질을 이용한 피부보호효과의 향상 (The Enhancement of Skin Sparing by Tray Materials for High Energy Photon Beam)

  • 추성실;이창걸;김귀언
    • Radiation Oncology Journal
    • /
    • 제11권2호
    • /
    • pp.449-454
    • /
    • 1993
  • 종양치료를 위하여 고에너지 X-선 또는 감마선을 인체에 조사할 경우 피부 표면 선량이 최대지점 선량의 $30~60\%$에 불과 함으로 피부보호 효과(Skin sparing effect)를 얻을 수 있는 장점을 갖고있다. 그러나 종양특성과 발병위치에 따라 조사면을 크게 하거나 선속내에 차폐물질 또는 보상여과판을 설치하여 치료할 경우 피부보호 효과가 감소되거나 없어지는 경우가 있고 이것은 종양치료에 중요한 요인이 되고 있다. 연세 암전문병원에 설치된 코발트 60원격치료기와 선형가속기에서 발생되는 4 MV및 10 MV x-선에 대한 피부선량을 측정하였으며 차폐물고정판(Tray) 구성 물질의 종류와 조사면의 크기 및 피부와 고정판간의 거 리에 따른 피부선량의 변화를 평가하였다. 방사선 조사면이 $15{\times}15\;cm^2$ 이상 넓고 피부와 collimator 간의 거리가 30 cm 이상일 때 피부 표면선량은 코발트 -60, 4, 10 MV에서 각각최대선량의 40, 30, $20\%$로 감소하였으며 조사면의 크기와 차폐 고정판의 물질에 따라 증감하였다. 차폐물을 고정시키는 고정판을 Lucite로 제작하고 고정판과 피부간의 거리를 약 15 cm 이상 간격을 주면 표면선량을 $50\%$로 줄일 수 있었고 주석, 구리, 납등을 부착시키면 전방산란 선량비율이 감소되어 피부선량은 $35\%$로 피부보호 효과를 얻을 수 있었다. 방사선의 전방산란비율은 에너지와 흡수물질의 원자번호에 관계되며 납과 주석 이 각각 코발트-60 감마선과 4~10 MV x-선의 전방산란비를 가장 크게 감소시켰다.

  • PDF

치과 임프란트 치료 계획을 위한 나선형 일반 단층촬영과 전산화 단층촬영시 흡수선량 및 유효선량 평가 (Absorbed and effective dose from spiral and computed tomography for the dental implant planning)

  • 홍병희;한원정;김은경
    • Imaging Science in Dentistry
    • /
    • 제31권3호
    • /
    • pp.165-173
    • /
    • 2001
  • Objectives : To evaluate the absorbed and effective doses of spiral and computed tomography for the dental implant planning. Materials and Methods: For radiographic projection, TLD chips were placed in 22 sites of humanoid phantom to record the exposure to skin and the mean absorbed dose to bone marrow, thyroid, pituitary, parotid and submandibular glands and nesophagus. Effective dose was calculated, using the method suggested by Frederiksen et al.. Patient situations of a single tooth gap in upper and lower midline region, edentulous maxilla and mandible were simulated for spiral tomography. 35 axial slices (maxilla) and 40 axial slices (mandible) with low and standard dose setting were used for computed tomography. All the radiographic procedures were repeated three times. Results: The mean effective dose in case of maxilla was 0.865 mSv, 0.452 mSv, 0.136 mSv and 0.025 mSv, in spiral tomography of complete edentulous maxilla, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). That in case of mandible was 0.614 mSv, 0.448 mSv, 0.137 mSv and 0.036 mSv, in spiral tomography of complete edentulous mandible, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). Conclusions: Based on these results, it can be concluded that low mAs computed tomography is recommended instead of spiral tomography for the complete edentulous maxilla and mandible dental implant treatment planning.

  • PDF

능동형 전자식 개인피폭선량계의 저에너지 X선 영역별 최적화를 위한 에너지보상 필터 두께에 대한 연구 (The Study of Energy Compensation Filter Thickness for Each Energy Area of Low Energy X-ray Beam Optimization on Active Electronic Personal Dosimeter)

  • 김정수;박연현;채현식
    • 한국방사선학회논문지
    • /
    • 제16권5호
    • /
    • pp.519-526
    • /
    • 2022
  • 능동형 전자식 개인피폭선량는 개인의 피폭 선량을 실시간으로 확인할 수 있는 장점을 가진 보조선량계이다. 하지만 국내에 사용되고 있는 다수의 능동형 개인피폭 선량계는 의료기관에서 사용하는 진단방사선 영역에서 큰 오차와 낮은 응답성을 가진다. 이에 본 연구에서는 Si 포토다이오드 검출기를 사용하는 능동형 전자식 개인선량계에서 저에너지 영역의 응답특성을 향상시키기 위한 에너지 보상 두께를 평가하였다. 40 kVp에서 80 kVp 영역에서는 Al 0.2 mm + Sn 1.0 mm 필터에서 우수한 응답특성을 보였고 80 kVp에서 120 kVp 영역에서는 Al 0.2 mm + Sn 1.6 mm 필터에서 우수한 응답특성을 보였다.