• Title/Summary/Keyword: low damage system

Search Result 577, Processing Time 0.034 seconds

A Failure Estimation Method of Steel Pipe Elbows under In-plane Cyclic Loading

  • Jeon, Bub-Gyu;Kim, Sung-Wan;Choi, Hyoung-Suk;Park, Dong-Uk;Kim, Nam-Sik
    • Nuclear Engineering and Technology
    • /
    • v.49 no.1
    • /
    • pp.245-253
    • /
    • 2017
  • The relative displacement of a piping system installed between isolated and nonisolated structures in a severe earthquake might be larger when without a seismic isolation system. As a result of the relative displacement, the seismic risks of some components in the building could increase. The possibility of an increase in seismic risks is especially high in the crossover piping system in the buildings. Previous studies found that an elbow which could be ruptured by low-cycle ratcheting fatigue is one of the weakest elements. Fatigue curves for elbows were suggested based on component tests. However, it is hard to find a quantitative evaluation of the ultimate state of piping elbows. Generally, the energy dissipation of a solid structure can be calculated from the relation between displacement and force. Therefore, in this study, the ultimate state of the pipe elbow, normally considered as failure of the pipe elbow, is defined as leakage under in-plane cyclic loading tests, and a failure estimation method is proposed using a damage index based on energy dissipation.

Experimental Study of Nd:YAG Laser Cleaning System for Removing Acrylic Resin and Surface Characteristic (Nd:YAG 레이저를 이용한 금속유물에 코팅된 아크릴수지의 제거 및 표면 특성 연구)

  • Lee, Hye-Youn;Cho, Nam-Chul
    • Journal of Surface Science and Engineering
    • /
    • v.45 no.4
    • /
    • pp.143-150
    • /
    • 2012
  • Laser cleaning have been found to be a useful cleaning tool to remove contaminants without inducing damage to the substrate and making secondary pollutant. In this study, the effect of Nd:YAG laser cleaning system, emitting at 1064 nm and 532 nm, on acrylic resin applied onto copper coupons and pieces of bronze was investigated. The samples after laser cleaning tests were examined using microscopy, FT-IR, SEM-EDS. As a result, the acrylic resin could be removed from most of the samples at low laser energy density. Laser wavelength 532 nm was more effective than 1064 nm because of using lower laser energy density, which could reduce heat damage to substrates. Although the acrylic resin was easily removed, it revealed melted surfaces and removed bronze patina which must remain. The problems should be solved by future studies using different laser system or laser wavelengths.

Decision Support System for Determination of Types and Locations of Low Impact Development Practices

  • Abdulai, Patricia Jitta;Song, Jae Yeol;Chung, Eun-Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.181-181
    • /
    • 2017
  • Low impact development (LID) practices has become important to mitigate the damage from natural disasters in urban areas. Thereby many hydrological simulation models can simulate the hydrological impact of LID practices. However, commonly used models are not able to provide specific information to most users such as where LIDs should be placed and what kind of LID should be designed. In this study, a decision support system which can be used with the EPA's SWMM was developed for the determination of LID types and locations of LID practices, named Water Management Prioritization Module (WMPM), was applied to a urbanized university campus. Eight sub-catchments were selected as feasible candidate areas for the planning of LID practices. Pre-designated infiltration trenches and permeable pavements were applied to each selected sub-catchments, followed by peak and total runoffs comparison between before/after planning of LIDs. Moreover, TOPSIS, one of a multi-criteria decision analysis method was used in the procedure of selecting target sub-catchment areas and final prioritization of LID types and locations. As a result, sub-catchments S4 with permeable pavements and S16 with infiltration trenches has shown the most decrease in total and peak runoffs, respectively. Therefore, WMPM was found to be effective in determining the best alternative among various scenarios generated and simulated.

  • PDF

Risk and Sensitivity Analysis during the Low Power and Shutdown Operation of the 1,500MW Advanced Power Reactor (1,500MW대형원전 정지/저출력 안전성향상을 위한 설계개선안 및 민감도 분석)

  • Moon, Ho Rim;Han, Deok Sung;Kim, Jae Kab;Lee, Sang Won;Lim, Hak Kyu
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.15 no.1
    • /
    • pp.33-39
    • /
    • 2019
  • An 1,500MW advanced power reactor required the standard design approval by a Korean regulatory body in 2014. The reactor has been designed to have a 4-train independent safety concept and a passive auxiliary feedwater system (PAFS). The full power risk or core damage frequency (CDF) of 1,500MW advanced power reactor has been reduced more than that of APR1400. However, the risk during the low power and shutdown (LPSD) operation should be reduced because CDF of LPSD is about 4.7 times higher than that of internal full power. The purpose of paper is to analysis design alternatives to reduce risk during the LPSD. This paper suggests design alternatives to reduce risk and presents sensitivity analysis results.

Development of Self-Diagnosis Function Concrete for Damage (자기손상자현 기능성 콘크리트 개발)

  • 장주영;김이성;김화중
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.198-201
    • /
    • 2003
  • The R.C Building will be superannuated as time passes. This program is generated by propagation of cracks. In order to manage such cracks, time and efforts, expense, etc. are required. In this study, glass sensors were embedding in a model beam and column and leakage of fluorescence and adhesive material was investigated. Further, currents in glass pipe were observed to find the leakage of liquid in glass pipes. Progressive cracks generated by cause the fracture of glass pipes. Therefore, the liquid become to flow and electric current stops, and the cracked part of the member can be found easily. Moreover, the adhesive delays progressive cracking system that responds in air, and the life of a structure can be made to extend. The purpose of this research is to develop of low price sensors that can perform of self-diagnosis in addition to ability of concrete repair concrete to damage.

  • PDF

Manufacturing of Ultrahigh Vacuum Electron Cyclotron Resonance Chemical Vapor Deposition Reactor and Si Wafer Surface Cleaning by Hydrogen Plasma (초고진공 전자 사이클로트론 공명 화학 기상증착장치의 제작과 수소 플라즈마를 이용한 실리콘 기판 표면 세정화)

  • 황석희;태흥식;황기웅
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.4
    • /
    • pp.63-69
    • /
    • 1994
  • The Ultrahigh Vacuum Electron Cyclotron Resonance Chemical Vapor Deposition(UHV-ECRCVD) system whose base pressure is 1${\times}10^{9}$ torr has been constructed. In-situ cleaning prior to the epitaxial growth was carried out at 56$0^{\circ}C$ by ECR generated uniform hydrogen plasma whose density is $10^{10}/cm{3}$. The natural oxide was effectively removed without damage by applying positive DC bias(+10V) to the substrate. RHEED(Reflection High Energy Electron Diffraction) analysis has been used to confirm the removal of the surgace oxide and the streaky 2$\times$1 reconstruction of the Si surface, and the suppression of the substrate damage is anaylized by X-TEM(cross-sectional Transmission Electron Microscopy). Surface cleaning technique by ECR hydrogen plasma confirmed good quality epitaxial growth at low temperature.

  • PDF

Response of self-centering braced frame to near-field pulse-like ground motions

  • Rahgozar, Navid;Moghadam, Abdolreza S.;Aziminejad, Armin
    • Structural Engineering and Mechanics
    • /
    • v.62 no.4
    • /
    • pp.497-506
    • /
    • 2017
  • A low damage self-centering braced frame equipped with post-tensioning strands is capable of directing damage to replaceable butterfly-shaped fuses. This paper investigates the seismic performance of rocking braced frame under near-field pulse-like ground motions compared to far-field records. A non-linear time history analysis is performed for twelve self-centering archetypes. A sensitivity analysis is carried out to examine the influences of ground motion types and modeling parameters. Findings represent the proper efficiency of the self-centering system under both far-field and near-field pulse-like ground motions.

Glycation-induced Inactivation of Antioxidant Enzymes and Modulation of Cellular Redox Status in Lens Cells

  • Shin, Ai-Hyang;Oh, Chang-Joo;Park, Jeen-Woo
    • Archives of Pharmacal Research
    • /
    • v.29 no.7
    • /
    • pp.577-581
    • /
    • 2006
  • Oxidative mechanisms are thought to have a major role in cataract formation and diabetic complications. Antioxidant enzymes play an essential role in the antioxidant system of the cells that work to maintain low steady-state concentrations of the reactive oxygen species. When HLE-B3 cells, a human lens cell line were exposed to 50-100 mM glucose for 3 days, decrease of viability, inactivation of antioxidant enzymes, and modulation of cellular redox status were observed. Significant increase of cellular oxidative damage reflected by lipid peroxidation and DNA damage were also found. The glycation-mediated inactivation of antioxidant enzymes may result in the perturbation of cellular antioxidant defense mechanisms and subsequently lead to a pro-oxidant condition and may contribute to various pathologies associated with the long term complications of diabetes.

The Effects of Soil Model in the Grounding System Design (접지시스템 설계에서 대지구조 모델의 영향 분석)

  • 한기항;심건보;오기봉
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.313-318
    • /
    • 2002
  • Purpose of the grounding system design are establish a safe environment for personnel as well as the general public in the vicinity of the power system equipment, and establish a low resistance connection to earth such that protective devices detect and isolate faults quickly and potential rise of the grounding system does not exceed a value which could damage electrical equipment. This paper deals with the grounding system design for the electric facilities. In this paper, emphasize the necessity of the computer programs for the grounding system designs. Especially, earth soil models for the grounding system design are must used two-layered soil model.

  • PDF

Seismic Fragility Assessment for Korean High-Rise Non-Seismic RC Shear Wall Apartment Buildings (국내 고층 비내진 철근콘크리트 벽식 아파트의 지진취약도 평가)

  • Jeon, Seong-Ha;Shin, Dong-Hyun;Park, Ji-Hun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.24 no.6
    • /
    • pp.293-303
    • /
    • 2020
  • Seismic fragility was assessed for non-seismic reinforced concrete shear walls in Korean high-rise apartment buildings in order to implement an earthquake damage prediction system. Seismic hazard was defined with an earthquake scenario, in which ground motion intensity was varied with respect to prescribed seismic center distances given an earthquake magnitude. Ground motion response spectra were computed using Korean ground motion attenuation equations to match accelerograms. Seismic fragility functions were developed using nonlinear static and dynamic analysis for comparison. Differences in seismic fragility between damage state criteria including inter-story drifts and the performance of individual structural members were investigated. The analyzed building had an exceptionally long period for the fundamental mode in the longitudinal direction and corresponding contribution of higher modes because of a prominently insufficient wall quantity in such direction. The results showed that nonlinear static analyses based on a single mode tend to underestimate structural damage. Moreover, detailed assessments of structural members are recommended for seismic fragility assessment of a relatively low performance level such as collapse prevention. On the other hand, inter-story drift is a more appropriate criterion for a relatively high performance level such as immediate occupancy.