• Title/Summary/Keyword: low buildings

Search Result 1,081, Processing Time 0.027 seconds

Real-time hybrid substructuring of a base isolated building considering robust stability and performance analysis

  • Avci, Muammer;Botelho, Rui M.;Christenson, Richard
    • Smart Structures and Systems
    • /
    • v.25 no.2
    • /
    • pp.155-167
    • /
    • 2020
  • This paper demonstrates a real-time hybrid substructuring (RTHS) shake table test to evaluate the seismic performance of a base isolated building. Since RTHS involves a feedback loop in the test implementation, the frequency dependent magnitude and inherent time delay of the actuator dynamics can introduce inaccuracy and instability. The paper presents a robust stability and performance analysis method for the RTHS test. The robust stability method involves casting the actuator dynamics as a multiplicative uncertainty and applying the small gain theorem to derive the sufficient conditions for robust stability and performance. The attractive feature of this robust stability and performance analysis method is that it accommodates linearized modeled or measured frequency response functions for both the physical substructure and actuator dynamics. Significant experimental research has been conducted on base isolators and dampers toward developing high fidelity numerical models. Shake table testing, where the building superstructure is tested while the isolation layer is numerically modeled, can allow for a range of isolation strategies to be examined for a single shake table experiment. Further, recent concerns in base isolation for long period, long duration earthquakes necessitate adding damping at the isolation layer, which can allow higher frequency energy to be transmitted into the superstructure and can result in damage to structural and nonstructural components that can be difficult to numerically model and accurately predict. As such, physical testing of the superstructure while numerically modeling the isolation layer may be desired. The RTHS approach has been previously proposed for base isolated buildings, however, to date it has not been conducted on a base isolated structure isolated at the ground level and where the isolation layer itself is numerically simulated. This configuration provides multiple challenges in the RTHS stability associated with higher physical substructure frequencies and a low numerical to physical mass ratio. This paper demonstrates a base isolated RTHS test and the robust stability and performance analysis necessary to ensure the stability and accuracy. The tests consist of a scaled idealized 4-story superstructure building model placed directly onto a shake table and the isolation layer simulated in MATLAB/Simulink using a dSpace real-time controller.

Permeable Coastal Pavement Structure for Shore Protection and Removal of Non-point Source Pollutants (연안재해 방지 및 비점오염원 유출저감을 위한 투수블록의 특성 연구)

  • Choi, Yun-Shik;Kim, Jong-Yeong;Han, Sangsoo;Kwon, Soonchul
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.597-606
    • /
    • 2019
  • Due to climate change, coastal areas are being flooded with torrential rain, typhoons, and tsunamis. In addition, non-point source pollutants (NPSs) that accumulated on the ground, streets, and buildings during the dry season are washed off by rain and stormwater runoff, which adds to the damage associated with environmental pollution, e.g., pollution that makes its way into the ocean. Recently, low impact development (LID) has been considered as a means of controlling water circulation and NPSs. In the coastal area, permeable blocks have been constructed mainly to reduce the flood damage caused by waves. Some important design factors that must be considered to ensure long-term performance are the permeability coefficient, clogging, and the efficiency of the removal of total suspended solids (TSS), but currently there are no standardized design criteria or testing techniques that are used worldwide. Herein, we analyzed the permeability coefficient and the TSS removal efficiency tendency according to the permeability area ratio with an easily-detachable, permeable block filled with calcinated yellow soils as the filter media. Our lab-scale tests indicated that, when the permeability area ratio was 25%, the reduction of the permeability coefficient after clogged was 11%, which was a significant decrease compared to other cases. Permeability persistence increased when the permeability area ratio increased from 50% to 75%. The TSS removal efficiency decreased as the permeability area ratio increased. Our pilot-scale test indicated that the TSS removal efficiency was more than 80% higher in all cases. We also found that the permeability persistence was excellent as the permeability area ratio increased, and, in actual construction, it is effective to set 5.3% of the total area as permeable area in terms of permeability and economic feasibility.

Optimization of long span portal frames using spatially distributed surrogates

  • Zhang, Zhifang;Pan, Jingwen;Fu, Jiyang;Singh, Hemant Kumar;Pi, Yong-Lin;Wu, Jiurong;Rao, Rui
    • Steel and Composite Structures
    • /
    • v.24 no.2
    • /
    • pp.227-237
    • /
    • 2017
  • This paper presents optimization of a long-span portal steel frame under dynamic wind loads using a surrogate-assisted evolutionary algorithm. Long-span portal steel frames are often used in low-rise industrial and commercial buildings. The structure needs be able to resist the wind loads, and at the same time it should be as light as possible in order to be cost-effective. In this work, numerical model of a portal steel frame is constructed using structural analysis program (SAP2000), with the web-heights at five locations of I-sections of the columns and rafters as the decision variables. In order to evaluate the performance of a given design under dynamic wind loading, the equivalent static wind load (ESWL) is obtained from a database of wind pressures measured in wind tunnel tests. A modified formulation of the problem compared to the one available in the literature is also presented, considering additional design constraints for practicality. Evolutionary algorithms (EA) are often used to solve such non-linear, black-box problems, but when each design evaluation is computationally expensive (e.g., in this case a SAP2000 simulation), the time taken for optimization using EAs becomes untenable. To overcome this challenge, we employ a surrogate-assisted evolutionary algorithm (SAEA) to expedite the convergence towards the optimum design. The presented SAEA uses multiple spatially distributed surrogate models to approximate the simulations more accurately in lieu of commonly used single global surrogate models. Through rigorous numerical experiments, improvements in results and time savings obtained using SAEA over EA are demonstrated.

Structural Performance of 800 MPa High-Strength Steel Members and Application to Highrise and Mega Building Structures

  • Lee, Cheol-Ho
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.3
    • /
    • pp.249-259
    • /
    • 2017
  • The use of high-strength steels in construction of highrise and mega building structures can bring about many technological advantages from fabrication to erection. However, key design criteria such as local and lateral stability in current steel design specifications were developed based on tests of ordinary steels which have stress-strain characteristics very different from that of high strength steels. A series of tests on 800 MPa tensile strength steel (HSA800) members are summarized in this paper which were conducted to investigate the appropriateness of extrapolating current ordinary-steel based design criteria to high strength steels. 800 MPa I-shape beam specimens designed according to flange local buckling (FLB) criteria of the AISC Specification developed a sufficient strength for elastic design and a marginal rotation capacity for plastic design. It is shown that, without introducing distinct and significant yield plateau to the stress-strain property of high-strength steel, it is inherently difficult to achieve a high rotation capacity even if all the current stability limits are met. 800 MPa I-shape beam specimens with both low and high warping rigidity exhibited sufficient lateral torsional buckling (LTB) strength. HSA800 short-column specimens with various edge restraint exhibited sufficient local buckling strength under uniform compression and generally outperformed ordinary steel specimens. The experimental P-M strength was much higher than the AISC nominal P-M strength. The measured residual stresses indicated that the impact of residual stress on inelastic buckling of high-strength steel is less. Cyclic seismic test results showed that HSA800 members have the potential to be used as non-ductile members or members with limited ductility demand in seismic load resisting systems. Finally, recent applications of 800 MPa high strength steel to highrise and mega building structures in Korea are briefly presented.

Evaluation of Thermal and Visual Environment for the Glazing and Shading Device in an Office Building with Installed of Venetian Blind (베네시안 블라인드가 적용된 오피스 건물의 외피 투과체 계획을 위한 열·빛 환경 평가에 대한 연구)

  • Kim, Chul-Ho;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.15 no.6
    • /
    • pp.101-109
    • /
    • 2015
  • Purpose: Glazing and shading devices influence a lot on the thermal and visual environment in office buildings. Solar heat and daylight are contrary concept, therefore proper arrangement of thermal and optical performance is needed when designing a glazing and shading devices. The purpose of this study is to examine the conditions of the glazing and shading devices available for promoting the reduction of cooling loads + lighting loads and the improvement in thermal comfort and visual comfort for the summer season in an office building installed with venetian blind. Method: This study established 12 simulation cases which have different glazings and the positions of venetian blind for evaluating different thermal and optical performance. And by using EnergyPlus v8.1 and Window v7.2 program, we quantitatively analyzed cooling loads + lighting loads, thermal comfort and visual comfort in an office building installed with the glazing and shading devices. Result: Consequently, Case 9(Double Low-E+Exterior Blind) is the best arrangement of solar heat gain and daylight influx, thereby becomes the most excellent case of reducing cooling+lighting loads(46.8%) and simultaneously becomes the enhancement case in thermal comfort. Also, DGI(Daylight glare index) under clear sky conditions in summer was evaluated to be 19.6, and thereby satisfied the recommendation level of allowing visual comfort.

Influence of Rice Ripening Time and Neighboring Habitat on Rodent Species Composition and Crop Damage (벼의 숙기와 논의 인접환경이 쥐의 종류구성과 벼의 피해에 미치는 영향)

  • Shin Young-Moo
    • Korean journal of applied entomology
    • /
    • v.13 no.3 s.20
    • /
    • pp.135-139
    • /
    • 1974
  • A survey on rodent damage to ripening rice was conducted in Sep.-Oct. in 1973 in order to indentify the habitat type which has the greatest influence on rodent populations and damage problems. Total 109 paddies were examined in three geographical regions in central part of Korea including Kangwon and Kyoungki Provinces, which represents mountainous, coastal and rice plain lands. Sample paddies were selected according to the neighboring or surrounding habitats as farm villages, upland-crop fields, grassy river banks, forests and rice plains. Snap trapping was also conducted in each of habitats. In April, 1974, field trips were taken to representative parts of Korea visiting farmers and rural guidance officers involving more than 100 people for the information of existing local problems. The general damage of rice was considerably low in 1973 averaging $63\%$ in early ripening varieties and $0.26\%$ in standard varieties, white the average lost in 1971 was $14.2\%$ in early ripening varieties and $2.7\%$ in standard varieties. But the most of severe damages was occurred within 50 meters (practically none beyond 100m) of farm villages, caused mainly by Norway rat (Rattus rottfus Caraco) and striped field mouse (Apodemus agrarius). The examples of existing local problems confirmed that the rodent damage to field crops is closely associated with rodent populations that have survived the winter in and around farm houses and buildings.

  • PDF

An Analysis of Thermal Environment Change according to Green Roof System (옥상녹화 조성에 따른 열환경 변화분석)

  • Park, Ji-Young;Jung, Eung-Ho;Kim, Dae-Wuk;Cha, Jae-Gyu;Shimizu, Aki
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.11a
    • /
    • pp.100-103
    • /
    • 2009
  • The impermeable area on the surface of city has been increased as buildings and artificial landcover have continually been increased. Urban development has gradually decreased the green zone in downtown and alienated the city from the natural environment on outskirt area devastating the natural eco system. There arise the environmental problems peculiar to city including urban heat island phenomenon, urban flood, air pollution and urban desertification. As one of urban plans to solve such problems, green roof system is attracting attentions. The purpose of this study was to investigate the heat reduction effect according to the development of green roof system and to quantify the heat reduction effect by analyzing through simulation the heat environment before and after green roof system. For thermal environment analysis, Thermo-Render 3.0 was used that was developed by Tokyo Industrial College to simulate. The simulation showed that the heat island index before and after the development of tree-planting on rooftop changed maximum $0.86^{\circ}C$ and the surface temperature changed about $20^{\circ}C$. Only with lawn planting, heat reduction effect was great and it means that the green roof system in low-management-light-weight type is enough to see effect. The simulation identified that only lawn planting for green rooftop brought such difference and could lower the heat island index at a narrow area. It is judged that application of green roof system to wider areas might relieve urban heat island phenomenon positively.

  • PDF

Forecast on Internal Condensation at Balcony Ceiling of Super-high Apartment Building Faced with Open Air (외기에 면한 초고층 아파트 발코니 천정 내부결로 예측)

  • Choi Yoon-Ki;Ahn Jae-Bong
    • Korean Journal of Construction Engineering and Management
    • /
    • v.4 no.4 s.16
    • /
    • pp.155-163
    • /
    • 2003
  • There are a growing number of cases to expand balconies of apartments faced with open air in order to enhance functional satisfaction and efficiency of dwelling space. In case of the balcony expansion at the floor, however, it is difficult to exclude a possibility of bringing about internal condensation due to the difference of temperature between indoor air and outdoor air caused by the Inflow of outer low-temperature air through the upper part of ceilings by failure in completely putting together the outer composite wall panels on the aluminum curtain walls installed at outer walls This study is to forecast possible occurrence of internal condensation around parapets and H-beam located at the inside of balcony ceilings on the uppermost floor of super-high apartment buildings faced with open air in order to provide dwellers with more comfortable environment in the related space and get rid of their uneasiness about the condensation. In this study, we estimated internal condensation, which vary in accordance with humidity pressure distribution, at curtain walls, stone panels or lower parts of slabs that constitute outer space of the residence and are weak against heat, through temperature forecast and temperature distribution interpretation program at normal two-dimension temperature

A Study on Design Development of Environment-friendly Mobile Home Sauna (친환경 모바일 홈 사우나 디자인 개발에 관한 연구)

  • Lee, Bong Kyu
    • Journal of the Korea Furniture Society
    • /
    • v.26 no.1
    • /
    • pp.77-91
    • /
    • 2015
  • The appeal of sauna is caused by the fact that through that, one can feel Korea's unique temperament and culture; however, because of its being a public facility and flooding of businesses due to excessive supplies of various additional features such as washing, playing, eating, sleeping and health care functions, issues of social resources and environment come to the fore, so it has reached a situation of red ocean that it is difficult to enter the market anymore. Taking these into account, this study focused on developing a thermal technology and design of the housing of an environment-friendly mobile home sauna, making the most use of the sauna's fundamental purpose and settling it as a tourist product, analyzing the marketing research on the existing sauna and considering the recent housing trends and lifestyles for a new concept sauna. Thus, regarding its characteristics and utilization, it was designed smaller than $10m^2$ (3 pyeong) so that it would be easy to install in any space and convenient to move. It can be installed in separate buildings and rest spaces such as country houses, resorts, pensions, camping grounds as well as outdoor houses, custom produced for a measure of pyeong that customers want so as to match up with the Enforcement Ordinance of the Agricultural Land Act in a concept of the farmer's hut and kitchen, bathroom and bathroom can be installed inside according to an option. In addition, regarding its efficacy, in order to give environment-friendly healing effects, materials such as Hinoki Cypress, red clay and hardwood charcoal were used, a fixed indoor temperature of $70{\sim}100^{\circ}C$ was maintained by heating methods such as electromagnetic wave free, energy saving and low-power boiler, and it was made to have excellent effects on fatigue recovery, relieving stress, skin care and diet through far-infrared emission.

Anaerobic Biotreatment of Animal Manure - A review of current knowledge and direction for future research -

  • Hong, Jihyung
    • Journal of Animal Environmental Science
    • /
    • v.11 no.2
    • /
    • pp.97-102
    • /
    • 2005
  • Anaerobic decomposition is one of the most common processes in nature and has been extensively used in waste and wastewater treatment for several centuries. New applications and system modifications continue to be adapted making the process either more effective, less expensive, or suited to the particular waste in question and the operation to which it is to be applied. Animal manure is a highly biodegradable organic material and will naturally undergo anaerobic fermentation, resulting in release of noxious odors, such as in manure storage pits. Depending on the presence or absence of oxygen in the manure, biological treatment process may be either aerobic or anaerobic. Under anaerobic conditions, bacteria carry on fermentative metabolisms to break down the complex organic substances into simpler organic acids and then convert them to ultimately formed methane and carbon dioxide. Anaerobic biological systems for animal manure treatment include anaerobic lagoons and anaerobic digesters. Methane and carbon dioxide are the principal end products of controlled anaerobic digestion. These two gases are collectively called biogas. The biogas contains $60\~70\%$ methane and can be used directly as a fuel for heating or electrical power generation. Trace amounts of ammonia and hydrogen sulfide ($100\~300\;ppm$) are always present in the biogas stream. Anaerobic lagoons have found widespread application in the treatment of animal manure because of their low initial costs, ease of operation and convenience of loading by gravity flow from the animal buildings. The main disadvantage is the release of odors from the open surfaces of the lagoons, especially during the spring warm-up or if the lagoons are overloaded. However, if the lagoons are covered and gases are collected, the odor problems can be solved and the methane collected can be used as a fuel. Anaerobic digesters are air-tight, enclosed vessels and are used to digest manure in a well-controlled environment, thus resulting in higher digestion rates and smaller space requirements than anaerobic lagoons. Anaerobic digesters are usually heated and mixed to maximize treatment efficiency and biogas production. The objective of this work was to review a current anaerobic biological treatment of animal manure for effective new technologies in the future.

  • PDF