• 제목/요약/키워드: loss of use

검색결과 3,318건 처리시간 0.036초

SmBCO Coated Conductor의 교류손실 측정 (Measurement of AC Loss in SmBCO Coated Conductor)

  • 박명진;김우석;이지광;오상수;하홍수;김호섭;고락길;유상임;문승현;최경달
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권1호
    • /
    • pp.52-56
    • /
    • 2008
  • According to the improvement of HTS conductor, HTS tapes which have the high current capacity have been recently researched in several nations. For large power application, AC loss is the most important issue in the development of AC superconducting power devices because it is closely related to the system operation efficiency. In 1st generation wire of HTS conductor, BSCCO, AC loss is too large to use for power application. Also, It is well known in recently years that YBCO CC, the 2nd generation wire, has also too much AC loss to apply to AC power devices. There are many trials to develop the new HTS wire having the low AC loss around the world. In this research, we present the measurment result of magnetization losses in SmBCO coated conductors. We measured the magnetization loss generated by perpendicularly exposed external magnetic field and compared with the analytic value of the strip model. Also, we presented the results compared with measured magnetization loss of an YBCO coated conductor.

동기 정류기를 이용한 클램프 모드 포워드 영전압 스위칭 다중 공진형 컨버터 (CM Forward ZVS-MRC with Synchronous Rectifier)

  • 안강순;김희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.395-399
    • /
    • 1996
  • The Clamp Mode(CM) Forward Zero Voltage Switching Multi Resonant Converter(ZVS-MRC) with self-driven synchronous rectifier in studied. The loss at the synchronous rectification stage of the converter is analyzed using MOSFET linear model and is compared with the loss at the conventional schottky diode rectification stage of the converter. From the results of the analysis, it is known that the use of MOSFETs as a synchronous rectifier reduces the loss at the rectification stage over the whole load range comparing the use of schottky diodes as a conventional rectifier in the converter. In order to verify the validity of the analysis, we have built a 33W(3.3V/10A) CM Forward ZVS-MRC with self-driven synchronous rectifier, in which switching frequency is 1MHz, and tested. From the experimental results, it is known that the synchronous rectification achieved about 1W improvement in the loss at the rectification stage and about 3% in the efficiency at the converter as compared with the conventional schottky diode rectification.

  • PDF

빠른 손실 감지를 이용한 TCP NewReno 분석 (Analysis of TCP NewReno using rapid loss detection)

  • 김동민;한제찬;김석규;임차식;이재용
    • 한국통신학회논문지
    • /
    • 제30권3B호
    • /
    • pp.130-137
    • /
    • 2005
  • 무선 통신 환경은 WiBro 등과 같은 새로운 무선 통신 기술들을 이용함에 따라 고속 인터넷 접속이 가능하도록 빠르게 변화하고 있다. 이에 따라 무선 구간에서 TCP(Transmission Control Protocol)를 이용한 신뢰성 있는 데이터 전송도 늘어날 전망이다. TCP는 유선상에서 사용될 목적으로 디자인되었기 때문에 유선과 다른 환경, 특히 무선에서 사용될 때에는 비 혼잡 손실에 의해 성능 저하를 겪게 된다. 특히 RTO(Retransmission Timeout)은 TCP의 성능에 많은 영향을 미친다. 본 논문에서는 기존 연구를 바탕으로 손실 복구 확률을 분석하고, 모의실험 결과를 통해 제안 알고리듬이 fast recovery 과정 중에 발생한 패킷 손실을 빠르게 감지하여 RTO없이 복구함으로써 성능 저하를 줄일 수 있음을 보인다.

휴대용 카세트 사용 청소년의 청력관련 요인 (A Study about the Factors Affecting Hearing loss in Adolescent's use of Personal Cassette Players(PCPs))

  • 임경희;박경민;박명화
    • 지역사회간호학회지
    • /
    • 제12권1호
    • /
    • pp.125-141
    • /
    • 2001
  • The purpose of this study was to investigate the factors affecting hearing loss in adolescent's use of PCPs, and to give the basic data for adolescent's hearing conservation program development and prevention education against their hearing loss. This study was a descriptive research about three factors affecting hearing loss; the knowledge and attitude about noise, the perception of hearing loss and the hearing threshold. The subjects of this study were 383 students in two general high schools and two vocational high schools in Teagu. They have been using PCPs but with no current or past ear disease. This study was carried out from Sep. 1. 2000 to Oct. 24, 2000. The instrument used for the knowledge and attitude about noise was a questionnaire developed by Rhee. Kyung Yong and Yi. Kwan Hyung(1996). The instrument used for the perception of hearing loss was a Smith Hearing Screening Questionnaire. A Belton Model 112 Audiometer. air-conduction hearing test instrument. was used for the hearing threshold. Data was analysed by a SPSS/Win 10.0 program with frequency. percentage, t-test. ANOVA and pearson correlation. The results of this study were as follows; 1. The average of concern about hearing scored the highest $3.66{\pm}0.70$. The average of perceived susceptibility scored $2.64{\pm}0.85$ and the average of knowledge about noise scored $2.13{\pm}0.56$. The average of total knowledge and attitude about noise scored $2.82{\pm}0.46$. The average of discomfort of hearing loss($2.51{\pm}0.81$) scored higher than that fear of hearing loss($1.35{\pm}0.53$). The average of total perception of hearing loss scored $1.93{\pm}0.59$. The hearing threshold of the subjects scored the highest at 500Hz(Lt. $23.21{\pm}6.62$, Rt. $23.39{\pm}7.02$) and scored higher in order of 1000Hz, 2000Hz, 4000Hz and 8000Hz. 2. The knowledge and attitude about noise and the perception of hearing loss were both affected only by one important characteristic, which was general and vocational high schools. The knowledge and attitude about noise raked (t=5.258, p=0.000), and perception of hearing loss raked(t=2.241. p=0.026). However. several other important characteristics also impacted significantly on the knowledge and attitudes about noise. They included grade (t = 1. 987. p=0.048), father's education(F=2.745. p=0.043), marks(F=3.157, p=0.044), drinking(t=2.307, p=0.022) and smoking(t=2.587, p=0.010). The left hearing threshold differed significantly by sex at 1000Hz(t=5.175, p<0.001) and 8000Hz (t=3.334, p<0.01). According to general and vocational high schools (p<0.001), at 500Hz (t=-5.056), 1000Hz (t=-5.253), 2000Hz (t=-4.905), 4000Hz (t=-4.704) and 8000Hz (t=-5.204) significant differences were also shown. Marks were significant at 1000Hz (F=3.824, p<0.05) and drinking was found to be significant at 500Hz(t=2.203, p<0.05). The right hearing threshold differed significantly by sex at l000Hz(t=5.557. p<0.001). 4000Hz(t=2.234. p<0.05) and 8000Hz (t=2.730. p<0.01). According to general and vocational high schools(p<0.001) at 500Hz (t=-4.730), 1000Hz(t=-6.271). 2000Hz (t=-4.573). 4000Hz(t=-3.554) and 8000Hz (t=-3.405) significant differences were also shown. Grades impacted at 500Hz(t=2.201. p<0.05) and 4000Hz(t=2.511. p<0.05), while marks were significant at l000Hz(F=4.1l5. p<0.05) and drinking was significant at 500Hz(t=2.333. p<0.05). 3. The left hearing threshold in accordance with use of PCPs differed significantly at 2000Hz(F=2.996. p=0.03l) according to volume level and at 8000Hz(F=2.197. p=0.022) according to duration${\times}$hours per day. The right hearing threshold differed significantly at l000Hz(F=3.075. p=0.028) according to volume level and at 8000Hz(F=2.925. p=0.034) according to duration. 4. The knowledge and attitudes about noise showed a light positive correlation with the perception of hearing loss. A positive correlation was shown. as stated previously in all Hz, between the left hearing threshold and the right hearing threshold, especially the highest correlation at 2000Hz(r=0.761. p=0.000). This study has shown that the factors related to adolescent's use of PCPs are important as they impact significantly an adolescent's hearing. These results then indicate that in future, when designing a hearing conservation program and prevention education this data should be considered.

  • PDF

Performance Analysis of LAN Interworking Unit for Capacity Dimensioning of Internet Access Links

  • Park, Chul-geun;Han, Dong-hwan
    • 한국통신학회논문지
    • /
    • 제25권4B호
    • /
    • pp.692-699
    • /
    • 2000
  • We build and analyze some types of queueing model to discuss capacity dimensioning of access links of a LAN interworking unit connected to the Internet backbone network. We assume that the IWU has a FIFO buffer to transmit IP packets to the Internet through the backbone. In order to analyze the system, we use a Poisson process and an MMPP process as input traffic models of IP packets and we use a general service time distribution as a service time model. But we use both an exponential service time and a deterministic service time in numerical examples for simple and efficient performance comparisons. As performance measures, we obtain the packet loss probability and the mean packet delay. We present some numerical results to show the effect of arrival rate, buffer size and link capacity on packet loss and mean delay.

  • PDF

Effectiveness and Safety of Tranexamic Acid in Spinal Deformity Surgery

  • Choi, Ho Yong;Hyun, Seung-Jae;Kim, Ki-Jeong;Jahng, Tae-Ahn;Kim, Hyun-Jib
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권1호
    • /
    • pp.75-81
    • /
    • 2017
  • Objective : Spinal deformity surgery has the potential risk of massive blood loss. To reduce surgical bleeding, the use of tranexamic acid (TXA) became popular in spinal surgery, recently. The purpose of this study was to determine the effectiveness of intra-operative TXA use to reduce surgical bleeding and transfusion requirements in spinal deformity surgery. Methods : A total of 132 consecutive patients undergoing multi-level posterior spinal segmental instrumented fusion (${\geq}5$ levels) were analyzed retrospectively. Primary outcome measures included intraoperative estimated blood loss (EBL), transfusion amount and rate of transfusion. Secondary outcome measures included postoperative transfusion amount, rate of transfusion, and complications associated with TXA or allogeneic blood transfusions. Results : The number of patients was 89 in TXA group and 43 in non-TXA group. There were no significant differences in demographic or surgical traits between the groups except hypertension. The EBL was significantly lower in TXA group than non-TXA group (841 vs. 1336 mL, p=0.002). TXA group also showed less intra-operative and postoperative transfusion requirements (544 vs. 812 mL, p=0.012; 193 vs. 359 mL, p=0.034). Based on multiple regression analysis, TXA use could reduce surgical bleeding by 371 mL (37 % of mean EBL). Complication rate was not different between the groups. Conclusion : TXA use can effectively reduce the amount of intra-operative bleeding and transfusion requirements in spinal deformity surgery. Future randomized controlled study could confirm the routine use of TXA in major spinal surgery.

농업용수 이용량 산정 합리화 방안 연구 (A study on the definition of Agricultural water use and the calculation methods)

  • 박갑순;이성희;김태철
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2002년도 학술발표회 발표논문집
    • /
    • pp.41-44
    • /
    • 2002
  • It is unreasonable to calculate the amount of agricultural water use by applying unit demand method, because it is different from other water use due to the return flow and reuse in the recycle of watershed. Data from irrigation pumping station and reservoir were analysed. Factors for water balance are precipitation, evapotranspiration, percolation, runoff, and management loss, etc. Here in the study, the amount of agricultural water was defined in the way of three different categories. First one is "Gross water" including evapotranspiration, percolation, and management loss. Second one is "Agricultural water" including Gross water and effective rainfall. Third one is "Broad water" which is abstracting the return flow from Agricultural water.

  • PDF

SINR loss and user selection in massive MU-MISO systems with ZFBF

  • Hu, Mengshi;Chang, Yongyu;Zeng, Tianyi;Wang, Bin
    • ETRI Journal
    • /
    • 제41권5호
    • /
    • pp.637-647
    • /
    • 2019
  • Separating highly correlated users can reduce the loss caused by spatial correlation (SC) in multiuser multiple-input multiple-output (MU-MIMO) systems. However, few accurate analyses of the loss caused by SC have been conducted. In this study, we define signal-to-interference-plus-noise ratio (SINR) loss to characterize it in multiuser multiple-input single-output (MU-MISO) systems, and use coefficient of correlation (CoC) to describe the SC between users. A formula is deduced to show the accurate relation between SINR loss and CoC. Based on this relation, we propose a user selection method that utilizes CoC to minimize the average SINR loss of users in massive MU-MISO systems. Simulation results verify the correctness of the relation and show that the proposed user selection method is very effective at reducing the loss caused by SC in massive MU-MISO systems.

Preprocessing and mass evolution of dark halos in the hydrodynamic zoom-in simulation

  • 한산;;최호승;;;;이석영
    • 천문학회보
    • /
    • 제43권2호
    • /
    • pp.38.2-38.2
    • /
    • 2018
  • To understand the assembly of the galaxy population in clusters today, it is important to first understand preprocessing, the impact of environments prior to cluster infall. We use 15 cluster samples from YZiCS, a hydrodynamic cluster zoom-in simulation to determine the significance of preprocessing, and focus on the tidal mass loss of dark matter halos. We find ~48% of the cluster member halos were once satellites of another host. The preprocessed fraction depends on each cluster's recent mass growth history. Also, we find that the total mass loss is a clear function of the time spent in a host. However, two factors can increase the mass loss rate considerably. First, if the satellite mass is approaching the mass of its host. Second, when the halo suffers tidal mass loss at a higher redshift. Being in hosts before cluster infall enables halos to experience tidal mass loss for an extended period of time.

  • PDF

마이크로파 실내 배전용 저반사형 전력 분배 스위치 (Low Loss Power Dividing Switch for Indoor Microwave Power Distribution)

  • 최영규
    • 전기학회논문지
    • /
    • 제62권1호
    • /
    • pp.90-94
    • /
    • 2013
  • A low loss power dividing switch in a indoor microwave power distribution system is proposed and designed with a various power dividing ratio. Switching characteristics are analyzed by use of the S-parameter of the switch. Newly proposed switch showed a very low return loss less than -30dB at the operating frequency of 2.45GHz. Three kinds of the switch in which we take out individually 1/2, 1/3 and 1/4 of the input power were fabricated, and measured the delivered, transmitted, and return loss power ratio. Simulated results showed that the lower power ratio is, the better accurate operating performance shows. This switch can switch the input power from 4.5% to 58% with the variance of 5% output power. The experimental results are in good agreement with the simulation within the return loss of 1%.