• Title/Summary/Keyword: loss of use

Search Result 3,328, Processing Time 0.032 seconds

Method of Optimum Efficiency to Coefficient of Utilization for Single Phase Induction Motor (단상 유도전동기의 이용률 변동에 대한 최적효율 산정기법)

  • Kim, Yang-Ho;Kim, Young-Sun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.4
    • /
    • pp.155-160
    • /
    • 2006
  • In this paper, deduced suitable optimization to request output condition after taking closely characteristic data of single phase induction motor(SIM) which is the possibility becoming economic is coming to be demanded. Motor proper move connection data took advantage of result of existing data and iron loss and copper loss, mechanical loss took advantage of statistical data, and decide motor move laking advantage of saving data and secondary resistance and optimum purpose of method that is proposed through single phase induction motor and comparison performance evaluation having on the same output parameter. That decide material factor, electric power damage ratio, and coefficient of utilization for optimum function by method that search request output and optimum values of efficiency case by case and decided is proper that is saved after take magnetizing reactance relationship. This research result which it sees against a material expense with use coefficient of utilization which is included in loss expense decides the same plan variable back the place efficiency is useful and will be applied.

Trouble type and preventive countermeasure of loading facilities in Busan harbor (부산항 하역장비에서 발생하는 고장형태와 예방대책)

  • 한근조;전영환;심재준;한동섭;김병진
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2002.03a
    • /
    • pp.189-196
    • /
    • 2002
  • As the quantity of transported goods increases, there is a lot of mechanical trouble with loading facilities. So it tremendously produces not only economic loss but also time loss. To reduce the loss from the trouble of leading facilities, it is necessary to analyse the distribution of the problem's occurrence and use the analyzed data to minimize the outbreak of trouble. So the data can be usefully used when designing or manufacturing and it also can be utilized for proper maintenance of operating equipment, frequency of inspection and repair, know-how of checking on equipment and purchasing of spare parts. And it is possible to minimize the loss if the propel maintenance is adapted

  • PDF

Dielectric Characteristics of Polytetrafluoroethylene-based Composites for Microwave Substrates with Formation Pressure (고주파 기판용 PTFE 복합체 형성 압력에 따른 유전 특성)

  • Choi, Hong Je;Chun, Myung Pyo;Cho, Yong Soo;Cho, Hak Rae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.6
    • /
    • pp.429-433
    • /
    • 2013
  • PTFE composites for use of microwave substrate were fabricated by impregnation and heat treatment fabrication with glass fabric. This study shows dielectric properties such as dielectric constant and loss can be controlled by thickness of PTFE composite with change of pressure condition in heating press process. The dielectric constant of the PTFE composites has decreasing tendency as given higher pressure condition. The dielectric loss has similar result too. Especially, the case of the dielectric loss was affected by the condition of pressure at heating press and had the best performance under 3 MPa. In order to see the reason why thickness conditions make different, their microstructures were also observed.

Prediction of Cavitation Occurrence in a Cryogenic Butterfly Valve by Flow Velocity (극저온 버터플라이 밸브의 유속에 따른 캐비테이션 발생 예측)

  • Kim, Seong-Dong;Kim, Beom-Seok;Choi, Young-Do;Lee, Young-Eo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.923-930
    • /
    • 2008
  • The butterfly valve is widely used in the industrial field as an on-off or a flow control valve. When the butterfly valve is used as a flow control valve. cavitation sometimes occurs in the range of high flow rate because of the small valve opening. Therefore. the pressure loss and the cavitation characteristics are investigated by use of a commercial CFD code. The results show that the possibility of cavitation occurrence in the cryogenic butterfly valve is very high in the case of valve opening angle below 10 degree and incident velocity over 6m/s. By increasing the inlet velocity at 10 degree of valve opening angle. the value of loss coefficient increased. However. by increasing the inlet velocity at 50 degree of valve opening angle. the value of loss coefficient decreased.

An Experimental Study on the Quality of High Flowing Concrete according to Ignition Loss of Fly-ash (플라이애쉬의 미연탄소 함유량에 따른 고유동콘크리트의 품질에 관한 실험적 연구)

  • 신흥철;강희관;최세진;김규용;김진만;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.381-384
    • /
    • 1997
  • It is necessary for manufacturing the high flowing to use the fly-ash as binder of concrete, therefore, Quality of fly-ash is very important to the fluidity of high flowing concrete. In this study, it is comparing and investigating the fludity of high flowing concrete used some fly-ash which it's Ignition loss is 2.44, 4.90, 7.10%. As a result of this experimental study, Ignition loss of fly-ash effects the properties of high flowing concrete, such as air content, flowability, passability etc. but even if valve of ignition loss is upper the specification, properties of high flowing concrete such as setting and hardening time, compressive strength etc.

  • PDF

A Gate Drive Circuit for Low Switching Losses and Snubber Energy Recovery

  • Shimizu, Toshihisa;Wada, Keiji
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.259-266
    • /
    • 2009
  • In order to increase the power density of power converters, reduction of the switching losses at high-frequency switching conditions is one of the most important issues. This paper presents a new gate drive circuit that enables the reduction of switching losses in both the Power MOSFET and the IGBT. A distinctive feature of this method is that both the turn-on loss and the turn-off loss are decreased simultaneously without using a conventional ZVS circuit, such as the quasi-resonant adjunctive circuit. Experimental results of the switching loss of both the Power MOSFET and the IGBT are shown. In addition, an energy recovery circuit suitable for use in IGBTs that can be realized by modifying the proposed gate drive circuit is also proposed. The effectiveness of both the proposed circuits was confirmed experimentally by the buck-chopper circuit.

Improvement of Properties of High Strength Concrete Using Fly Ash and Gypsum (플라이 애시 및 석고를 활용한 고강도 콘크리트의 성능개선)

  • 김기형;최재진;최연왕
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.5
    • /
    • pp.99-105
    • /
    • 1999
  • In producing high strength concrete, the most practical method is to use high range water reducing admixture(HRWR). Workabili쇼 of concrete using HRWR varies rapidly with elapsed time after mixing. Effects of fly ash and gypsum on slump loss and compressive strength of concrete were examined by experiment in this study. The slump loss of high strength concrete was reduced with increase of substitution ratio of fly ash. When 2~4% gypsum of cement weight was applied, the reduction of slump loss was not prominent and strength increase appeared at all test ages.

The High Power AC-DC Buck Converter of High Efficienty Using Loss-Less Snubber (로스레스 스너버를 사용한 고효율의 대용량 AC-DC 강압형 컨버터)

  • 문상필;서기영;이현우
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.951-954
    • /
    • 1998
  • This paper proposed that a high power AC-DC buck converter topology of high efficiency using loss-less snubber operates with four chopper connecting a number of parallel circuit. To improve these, a large number of soft switching topologies included a resonant circuit have been proposed. And, some simulative resutls on computer is included to confirm the validity of the analytical results. The partial resonant circuit makes use of a inductor using step-down and a condenser of loss-less snubber. The result is that the switching loss is very low and the efficiency of system is high. And the snubber condenser used in partial resonant circuit makes charging energy regenerated at input power source of rresonant operation. The proposed conversion system is deemed the most suitable for high power applications where the power switching devices are used.

  • PDF

Water loss Control in DMA Monitoring System Used Wireless Technology

  • Malithong, P.;Gulphanich, S.;Suesut, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.773-777
    • /
    • 2005
  • This article is about using information technology to apply with water loss inspection system in District Metering Area (DMA). Inspector can check Flow rate and Minimum Night Flow; NMF via Smart Phone or PDA include sending SMS Alert in case the Pressure, Flow rate and NMF is over the range of controlling. This will be used as equipment to implement water loss in international proactive and can keep on water loss reduction more efficiency. The system consists of Data Logger which collects data of Flow rate from DMA Master Meter. PC is Wap Server which dial via modem in order to get data through FTP Protocal that will convert text file to Microsoft Access Database. Wappage will use xhtml language to show database on Wapbrowser and can show the result on Smart Phone or PDA by graph and table for system analysis.

  • PDF

Approximate Cell Loss Performance in ATM Networks: In Comparison with Exact Results

  • Lee, Hoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.4A
    • /
    • pp.489-495
    • /
    • 2000
  • In this paper we propose an approximate method to estimate the cell loss probability(CLP) due to buffer overflow in ATM networks. The main idea is to relate the buffer capacity with the CLP target in explicit formula by using the approximate upper bound for the tail distribution of a queue. The significance of the proposition lies in the fact that we can obtain the expected CLP by using only the source traffic data represented by mean rate and its variance. To that purpose we consider the problem of estimating the cell loss measures form the statistical viewpoint such that the probability of cell loss due to buffer overflow does not exceed a target value. In obtaining the exact solution we use a typical matrix analytic method for GI/D/1B queue where B is the queue size. Finally, in order to investigate the accuracy of the result, we present both the approximate and exact results of the numerical computation and give some discussion.

  • PDF