• 제목/요약/키워드: loop primers

검색결과 47건 처리시간 0.03초

Simple and Rapid Detection of Potato leafroll virus by Reverse Transcription Loop-mediated Isothermal Amplification

  • Ju, Ho-Jong
    • The Plant Pathology Journal
    • /
    • 제27권4호
    • /
    • pp.385-389
    • /
    • 2011
  • A new reverse transcription loop-mediated isothermal amplification (RT-LAMP) method for the Potato leafroll virus (PLRV) was developed and compared with conventional reverse transcription polymerase chain reaction (RT-PCR) to address its advantages over RTPCR. RT-LAMP primers were designed from the open reading frame 3 (ORF3) sequence of PLRV. The RT-LAMP reactions were conducted without or with a set of loop primers. By real-time monitoring using Turbimeter, the RT-LAMP (with loop primers) detects PLRV in less than 30 min, compared to 120 min of RT-PCR. By adding fluorescent reagent during the reaction, final products of the RT-LAMP were fluorescently visualized under UV light or could be differentiated by naked-eye inspection under normal light. The RT-LAMP was extremely sensitive, about 2000-fold more sensitive than RT-PCR. This study presents great potential of the RT-LAMP for diagnosis and PLRV epidemiology because RT-LAMP method is speedy, sensitive, inexpensive, and convenient.

Loop-mediated isothermal amplification (LAMP)법을 이용한 Streptococcus parauberis 의 신속 진단 (Loop-mediated Isothermal Amplification (LAMP) for Detection of Streptococcus parauberis)

  • 문경미;김동휘;허문수
    • 생명과학회지
    • /
    • 제24권4호
    • /
    • pp.428-436
    • /
    • 2014
  • Loop-mediated isothermal amplification (LAMP)법은 등온에서 DNA 주형을 변성시키지 않고 실시하기 때문에, autocycling 가닥 변위 DNA 합성에 의존한다. 그래서 고가의 PCR 장비를 필요로 하지 않고 등온 유지가 가능한 저가의 장비인 항온 수조, 오븐, 온장고 등에서 증폭이 가능하다. 본 연구진은 Streptococcus parauberis의 random primer중에서 5개를 선정하여, 신장도가 높은 2개의 primer를 이용하여 최적 반응온도 및 최적 반응시간, 최적 반응 조건들을 확립하였다. 그리고 기존의 PCR과 LAMP의 민감도의 비교 분석을 측정한 결과, LAMP의 높은 검출 한계를 확인할 수 있었다. 본 논문에서는 non-target DNA의 영향을 받지 않고 등온 조건 하에서 DNA를 증폭시킬 수 있는 LAMP법과 SYBR-green I를 이용하여 시각화시켰으며, 기존의 PCR과 비교 분석함으로써, S. parauberis에 대한 신속하고 정확한 진단법을 확립하였다.

Loop-mediated isothermal amplification (LAMP)법을 이용한 Vibrio alginolyticus의 신속 진단법 개발 (Development of Loop-mediated Isothermal Amplification (LAMP) for Detection of Vibrio alginolyticus)

  • 홍승현;허문수
    • 생명과학회지
    • /
    • 제25권8호
    • /
    • pp.903-909
    • /
    • 2015
  • LAMP (Loop-mediated Isothermal Amplification)법은 PCR를 기반으로 등온에서 autocycling 가닥 변위 DNA 합성에 의존하며, Bst polymerase를 사용하여 진단하는 방법이다. 이것은 대상 DNA의 여섯 개의 배열을 인식하는 4개의 특정 primer의 도움을 받아 단시간 안에 병원체를 식별하는 높은 특이성을 지니고 있다. 본 연구에서는 LAMP로 수생에서 위험한 병원체인 Vibrio alginolyticus의 특별한 LAMP primer를 제작하였으며, 신속한 진단을 위해 MgSO4, dNTP, Betaine, Bst polymerase의 최적 반응 조건의 특이성 및 기존의 PCR보다 10배 정도의 민감하다는 것을 확인하였다. 또한, 디자인 되어진 LAMP primer가 다른 Vibrio 종들 중 오직 V. alginolyticus에서만 반응한 것을 확인 할 수 있었다. 본 논문에서는 병원체 세균인 V. alginolyticus의 빠르고 민감한 효과적인 진단으로 양식 질병들을 조기에 발견할 수 있도록 개발하였다.

Development of reverse-transcription loop-mediated isothermal amplification assays for point-of-care testing of human influenza virus subtypes H1N1 and H3N2

  • Ji-Soo Kang;Mi-Ran Seo;Yeun-Jun Chung
    • Genomics & Informatics
    • /
    • 제20권4호
    • /
    • pp.46.1-46.7
    • /
    • 2022
  • Influenza A virus (IAV) is the most widespread pathogen causing human respiratory infections. Although polymerase chain reaction (PCR)-based methods are currently the most commonly used tools for IAV detection, PCR is not ideal for point-of-care testing. In this study, we aimed to develop a more rapid and sensitive method than PCR-based tools to detect IAV using loop-mediated isothermal amplification (LAMP) technology. We designed reverse-transcriptional (RT)-LAMP primers targeting the hemagglutinin gene. RNAs from reference H1N1 and H3N2 showed specific RT-LAMP signals with the designed primers. We optimized the reaction conditions and developed universal reaction conditions for both LAMP assays. Under these conditions, the detection limit was 50 copies for both RT-LAMP assays. There was no non-specific signal to 19 non-IAV respiratory viruses, such as influenza B virus, coronaviruses, and respiratory syncytial viruses. Regarding the reaction time, a positive signal was detected within 25 min after starting the reaction. In conclusion, our RT-LAMP assay has high sensitivity and specificity for the detection of the H1 and H3 subtypes, making it suitable for point-of-care IAV testing.

Development of a Rapid Detection Method for Potato virus X by Reverse Transcription Loop-Mediated Isothermal Amplification

  • Jeong, Joojin;Cho, Sang-Yun;Lee, Wang-Hyu;Lee, Kui-jae;Ju, Ho-Jong
    • The Plant Pathology Journal
    • /
    • 제31권3호
    • /
    • pp.219-225
    • /
    • 2015
  • The primary step for efficient control of viral diseases is the development of simple, rapid, and sensitive virus detection. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) has been used to detect viral RNA molecules because of its simplicity and high sensitivity for a number of viruses. RT-LAMP for the detection of Potato virus X (PVX) was developed and compared with conventional reverse transcription polymerase chain reaction (RT-PCR) to demonstrate its advantages over RT-PCR. RT-LAMP reactions were conducted with or without a set of loop primers since one out of six primers showed PVX specificity. Based on real-time monitoring, RT-LAMP detected PVX around 30 min, compared to 120 min for RT-PCR. By adding a fluorescent reagent during the reaction, the extra step of visualization by gel electrophoresis was not necessary. RT-LAMP was conducted using simple inexpensive instruments and a regular incubator to evaluate whether RNA could be amplified at a constant temperature instead of using an expensive thermal cycler. This study shows the potential of RT-LAMP for the diagnosis of viral diseases and PVX epidemiology because of its simplicity and rapidness compared to RT-PCR.

Rapid Detection of Viable Escherichia coli O157 by Coupling Propidium Monoazide with Loop-Mediated Isothermal Amplification

  • Zhao, Xihong;Wang, Jun;Forghani, Fereidoun;Park, Joong-Hyun;Park, Myoung-Su;Seo, Kun-Ho;Oh, Deog-Hwan
    • Journal of Microbiology and Biotechnology
    • /
    • 제23권12호
    • /
    • pp.1708-1716
    • /
    • 2013
  • Conventional molecular detection methods cannot distinguish between viable and dead Escherichia coli O157 cells. In this study, the loop-mediated isothermal amplification (LAMP) method combined with propidium monoazide (PMA) treatment was developed to selectively detect viable E. coli O157 cells. Four primers, including outer primers and inner primers, were specially designed for the recognition of six distinct sequences on the serogroups (O157) of the specific rfbE gene of the E. coli O157 genome. PMA selectively penetrated through the compromised cell membranes and intercalated into DNA. Amplification of DNA from dead cells was completely inhibited by $3.0{\mu}g/ml$ PMA, whereas the DNA derived from viable cells was amplified remarkably within 1 h by PMA-LAMP. Exhibiting high sensitivity and specificity, PMA-LAMP is a suitable method for evaluating the inactivation efficacy of slightly acidic electrolyzed water in broth. PMA-LAMP can selectively detect viable E. coli O157 cells. This study offers a novel molecular detection method to distinguish between viable and dead E. coli O157 cells.

Rapid and Efficient Detection of 16SrI Group Areca Palm Yellow Leaf Phytoplasma in China by Loop-Mediated Isothermal Amplification

  • Yu, Shao-shuai;Che, Hai-yan;Wang, Sheng-jie;Lin, Cai-li;Lin, Ming-xing;Song, Wei-wei;Tang, Qing-hua;Yan, Wei;Qin, Wei-quan
    • The Plant Pathology Journal
    • /
    • 제36권5호
    • /
    • pp.459-467
    • /
    • 2020
  • Areca palm yellow leaf (AYL) disease caused by the 16SrI group phytoplasma is a serious threat to the development of the Areca palm industry in China. The 16S rRNA gene sequence was utilized to establish a rapid and efficient detection system efficient for the 16SrI-B subgroup AYL phytoplasma in China by loop-mediated isothermal amplification (LAMP). The results showed that two sets of LAMP detection primers, 16SrDNA-2 and 16SrDNA-3, were efficient for 16SrI-B subgroup AYL phytoplasma in China, with positive results appearing under reaction conditions of 64℃ for 40 min. The lowest detection limit for the two LAMP detection assays was the same at 200 ag/μl, namely approximately 53 copies/μl of the target fragments. Phytoplasma was detected in all AYL disease samples from Baoting, Tunchang, and Wanning counties in Hainan province using the two sets of LAMP primers 16SrDNA-2 and 16SrDNA-3, whereas no phytoplasma was detected in the negative control. The LAMP method established in this study with comparatively high sensitivity and stability, provides reliable results that could be visually detected, making it suitable for application and research in rapid diagnosis of AYL disease, detection of seedlings with the pathogen and breeding of disease-resistant Areca palm varieties.

Rapid and Sensitive Detection of Salmonella in Chickens Using Loop-Mediated Isothermal Amplification Combined with a Lateral Flow Dipstick

  • Liu, Zhi-Ke;Zhang, Qiu-Yu;Yang, Ning-Ning;Xu, Ming-Guo;Xu, Jin-Feng;Jing, Ming-Long;Wu, Wen-Xing;Lu, Ya-Dong;Shi, Feng;Chen, Chuang-Fu
    • Journal of Microbiology and Biotechnology
    • /
    • 제29권3호
    • /
    • pp.454-464
    • /
    • 2019
  • Salmonellosis is a highly contagious bacterial disease that threatens both human and poultry health. Tests that can detect Salmonella in the field are urgently required to facilitate disease control and for epidemiological investigations. Here, we combined loop-mediated isothermal amplification (LAMP) with a chromatographic lateral flow dipstick (LFD) to rapidly and accurately detect Salmonella. LAMP primers were designed to target the Salmonella invA gene. LAMP conditions were optimized by adjusting the ratio of inner to outer primers, $MgSO_4$ concentration, dNTP mix concentration, amplification temperature, and amplification time. We evaluated the specificity of our novel LAMP-LFD method using six Salmonella species and six related non-Salmonella strains. All six of the Salmonella strains, but none of the non-Salmonella strains, were amplified. LAMP-LFD was sensitive enough to detect concentrations of Salmonella enterica subsp. enterica serovar Pullorum genomic DNA as low as $89fg/{\mu}l$, which is 1,000 times more sensitive than conventional PCR. When artificially contaminated feed samples were analyzed, LAMP-LFD was also more sensitive than PCR. Finally, LAMP-LFD gave no false positives across 350 chicken anal swabs. Therefore, our novel LAMP-LFD assay was highly sensitive, specific, convenient, and fast, making it a valuable tool for the early diagnosis and monitoring of Salmonella infection in chickens.

Identification of Pork Adulteration in Processed Meat Products Using the Developed Mitochondrial DNA-Based Primers

  • Ha, Jimyeong;Kim, Sejeong;Lee, Jeeyeon;Lee, Soomin;Lee, Heeyoung;Choi, Yukyung;Oh, Hyemin;Yoon, Yohan
    • 한국축산식품학회지
    • /
    • 제37권3호
    • /
    • pp.464-468
    • /
    • 2017
  • The identification of pork in commercially processed meats is one of the most crucial issues in the food industry because of religious food ethics, medical purposes, and intentional adulteration to decrease production cost. This study therefore aimed to develop a method for the detection of pork adulteration in meat products using primers specific for pig mitochondrial DNA. Mitochondrial DNA sequences for pig, cattle, chicken, and sheep were obtained from GenBank and aligned. The 294-bp mitochondrial DNA D-loop region was selected as the pig target DNA sequence and appropriate primers were designed using the MUSCLE program. To evaluate primer sensitivity, pork-beef-chicken mixtures were prepared as follows: i) 0% pork-50% beef-50% chicken, ii) 1% pork-49.5% beef-49.5% chicken, iii) 2% pork-49% beef-49% chicken, iv) 5% pork-47.5% beef-47.5% chicken, v) 10% pork-45% beef-45% chicken, and vi) 100% pork-0% beef-0% chicken. In addition, a total of 35 commercially packaged products, including patties, nuggets, meatballs, and sausages containing processed chicken, beef, or a mixture of various meats, were purchased from commercial markets. The primers developed in our study were able to detect as little as 1% pork in the heat treated pork-beef-chicken mixtures. Of the 35 processed products, three samples were pork positive despite being labeled as beef or chicken only or as a beef-chicken mix. These results indicate that the developed primers could be used to detect pork adulteration in various processed meat products for application in safeguarding religious food ethics, detecting allergens, and preventing food adulteration.

Development of a Loop-Mediated Isothermal Amplification Assay for Rapid Detection of Nocardia salmonicida, the Causative Agent of Nocardiosis in Fish

  • Xia, Liqun;Zhang, Honglian;Lu, Yishan;Cai, Jia;Wang, Bei;Jian, Jichang
    • Journal of Microbiology and Biotechnology
    • /
    • 제25권3호
    • /
    • pp.321-327
    • /
    • 2015
  • Nocardia salmonicida is one of the main pathogens of fish nocardiosis. The purpose of this study was to build a loop-mediated isothermal amplification (LAMP) method for the rapid and sensitive detection of N. salmonicida. A set of four primers were designed from the 16S-23S rRNA intergenic spacer region of N. salmonicida, and conditions for LAMP were optimized as incubating all the reagents for 60 min at 64℃. LAMP products were judged with agar gel electrophoresis as well as with the naked eye after the addition of SYBR Green I. Results showed the sensitivity of the LAMP assay was 1.68 × 103 CFU/ml (16.8 CFU per reaction) and 10-fold higher than that of PCR. The LAMP method was also effectively applied to detect N. salmonicida in diseased fish samples, and it may potentially facilitate the surveillance and early diagnosis of fish nocardiosis.