• Title/Summary/Keyword: loop gain

Search Result 636, Processing Time 0.041 seconds

Design of RF Power Detector Module with Switch for W-CDMA Optic Repeater (스위치를 이용한 W-CDMA 광중계기용 RF 전력 검출기 모듈의 설계)

  • Lee, Yun-Bok;Cho, Jung-Yong;Shin, Kyung-Sub;Lee, Yong-An;Lee, Hong-Min
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.389-393
    • /
    • 2003
  • This paper describes the design of enhanced TSSI RF Power Detector which has wide dynamic range using switch and Log amp. This Power Detector consists of low and high gain loops, and they adaptively switched by output DC voltage which is proportioned to input power level. Because Power Detector needs to separate the channel, so architecture is heterodyne system having 70MHz intermediate frequency. This proposed RF Power Detector is settle to the satisfaction of Closed loop power control system for W-CDMA optic repeater, and the obtained dynamic range cover the higher than 50dB.

  • PDF

Robust control using Analog Adaptive Resonance Theory

  • Son, Jun-Hyeok;Seo, Bo-Hyeok
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.93-95
    • /
    • 2006
  • In many control system applications, the system designed must not only satisfy the damping and accuracy specifications, but the control must also yield performance that is robust to external disturbance and parameter variations. We have shown that feedback in conventional control systems has the inherent ability of reducing the effects of external disturbance and parameter variations. Unfortunately, robustness with the conventional feedback configuration is achieved only with a high loop gain, which is normally detrimental to stability. The design of intelligent, autonomous machines to perform tasks that are dull, repetitive, hazardous, or that require skill, strength, or dexterity beyond the capability of humans is the ultimate goal of robotics research. This paper prove the robust control using Analog Adaptive Resonance Theorv(ART2) Algorithm about case study.

  • PDF

Frequency Analysis Method for Linear Optically Coupled Isolation Amplifier (선형 광결합 절연 증폭기의 주파수 특성분석 기법)

  • Ahn, Hee-Wook;Sung, Young-Whee;Kim, San-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2240-2246
    • /
    • 2007
  • Optically coupled linear isolation amplifier requires special care to avoid oscillation in actual applications. In this paper methods to analyze the frequency characteristics of the amplifier are proposed to reveal the cause of oscillation and to provide design guidelines. The loop gain of the amplifier obtained through the equivalent circuit model shows that the phase margin is too small to ensure stable operations. Methods to get non-oscillatory response are proposed and the resulting frequency responses are analyzed. The common method adding a small capacitor to the amplifier is shown to degrade the frequency bandwidth. The frequency response of output voltage explains the need of filter capacitor in output stage. The usefulness of the method is verified through experiments.

Adaptive Fuzzy Control with Reduced Complexity for Robot Manipulators (구조적 복잡성을 감소시킨 로봇 머니퓰레이터 적응 퍼지 제어)

  • Jang, Jin-Su;Yang, Hai-Won
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1775-1776
    • /
    • 2008
  • This paper presents a adaptive fuzzy control suitable for motion control of multi-link robot manipulators with uncertainties. When joint velocities are available, full state adaptive fuzzy feedback control is designed to ensure the stability of the closed loop dynamic. If the joint velocities are not measurable, an observer is introduced and an adaptive output feedback control is designed based on the estimated velocities. To reduce the number of fuzzy rules of the fuzzy controller, we consider the properties of robot dynamics and the decomposition of the unknown input gain matrix. The proposed controller is robust against uncertainties and external disturbances. The validity of the control scheme is demonstrated by computer simulations on a two-link robot manipulator.

  • PDF

Dynamic droop-based power smoothing of a doubly-fed induction generator (시변 드룹을 이용한 이중여자풍력발전기의 출력 평활화)

  • Hwang, Min;Lee, Jinsik;Lee, Hyewon;Kang, Yong Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.177-178
    • /
    • 2015
  • This paper proposes a power smoothing scheme of a doubly-fed induction generator. The proposed scheme aims to mitigate system frequency deviation caused by the variable wind. To achieve this, a dynamic droop loop is used and its gain changes with rate of change of frequency so that it can release a large amount of kinetic energy at the initial stage of a frequency event. The performance of the proposed scheme was investigated in a model system with high wind penetration using EMTP-RV simulator. The test results indicate that the scheme can smooth the output power by absorbing or releasing the output power under a varying wind condition.

  • PDF

Speed Controller Design considering Current Controller Dynamics for Industry Servo Applications (전류제어기 동특성을 고려한 산업용 서보 구동시스템의 속도제어기 설계)

  • 석줄기;이동춘
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.5
    • /
    • pp.465-471
    • /
    • 2002
  • This paper presents a novel PID speed controller for industry servo applications. Considering the speed loop delay, it allows an automatic controller bandwidth/gain setup with the bandwidth of current controller. In addition, the proposed design nile gives uniformly satisfactory performance and the motor speed stays on a desired response curve with minimal oscillation and settling time. This approach can be applied in conjunction with the cascaded position controller which is widely used in practice.

Alternately Zero Voltage Switched Multi Resonant Converter Topology (교번으로 영전압 스위칭 되는 다중공진형 컨버터 토폴로지)

  • Kim Chang-Sun;Park Hyo-Sik;Oh Yong-Seung;Kim Hee-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.360-363
    • /
    • 2002
  • In the resonant converters which can provide high efficiency and high power density, the resonant voltage stress is about $4\~5$ times the input voltage. It needs the power switch with high ratings. This is a reason why the conduction loss is increased. In this paper, it proposes the alternately zero voltage switched forward, flyback multi resonant converter topology for reducing the voltage stress using alternately zero voltage switching technique. And the proposed AT forward MRC Is experimentally considered about the loop gain with HP4194A network analyzer

  • PDF

A Study on the Fuzzy Modifier of PI Control for Improvement of Tracking properties in Induction Motor System

  • Kim, Yuen-Chung;Ahn, Jeong-Joon;Kim, Jae-Mun;Won, Chung-Yuen;Kim, Young-Real
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.7-10
    • /
    • 1998
  • Because of simple control algorithm and easy implementation, the conventional PI controller has been widely used in industrial application. But, it is very difficult to find the optimal PI control gain. Therefore, in improperly tuned PI controller or parameter variation, to obtain optimal performance, the novel PI controller, which consist of conventional PI controller and 4-rule based fuzzy logic, are presented in this paper. The novel PI controller which exhibits a stabilizing effects on the closed-loop system, has good robustness regarding the improperly tuned PI controller or parameter variation. The simulations are performed to verify the capability of proposed control method on induction motor.

  • PDF

Robust Pole Assignment Control for Linear Systems with Structured Uncertainty (구조적 불확실성을 갖는 선형계의 강인한 극배치 제어)

  • Kim, Young-Chol
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.3
    • /
    • pp.300-310
    • /
    • 1992
  • This paper deals with the problem of robust pole-assignment control for linear systems with structured uncertainty. It considers two cases whose colsed-loop characteristic equations are presented as a family of interval polynomial and polytopic polynomial family respectively. We propose a method of finding the pole-placement region in which the fixed gain controller guarantees the required damping ratio and stability margin despite parameter perturbation. Some results of Kharitonov like stability and two kinds of transformations are included. As an illustrative example, we show that the proposed method can apply effectivly to the single magnet levitation system including some uncertainties (mass, inductance etc.).

  • PDF

New Unified PID Position Control Algorithm for High Performance Position Control Loop Using Linear Machine Drive (선형 전동기의 고성능 위치 제어를 위한 새로운 통합 PID 제어기에 관한 연구)

  • Lee, You-In;Kim, Joohn-Sheok;Kim, Yong-Yil
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.389-391
    • /
    • 1999
  • Recently, the application of the linear machine for industrial field is remarkable increased, especially for the gantry machine. machine tool system and CNC. In these application fields. high precise position control performance is essentially required in both the steady and transient state. And linear machine is necessary for high-precision processing and manipulation when relatively high forces are involved. This paper presents the new unified PID position control algorithm which have rare sensitivity to disturbance, which the gain adjusting process is simple. Also this paper investigates the use of the New Unified PID control to design for high stiffness. Through the experimental results, it is shown that the proposed algorithm has high dynamic characteristic for the linear machine application field nevertheless of its simple structure.

  • PDF