• 제목/요약/키워드: longitudinal rebar

검색결과 43건 처리시간 0.018초

Experimental investigation on shear capacity of RC beams with GFRP rebar & stirrups

  • Vora, Tarak P.;Shah, Bharat J.
    • Steel and Composite Structures
    • /
    • 제21권6호
    • /
    • pp.1265-1285
    • /
    • 2016
  • This paper presents experimental results of advanced investigation carried out on the beams reinforced with Glass Fiber Reinforced Polymer (GFRP) rebar and stirrups. Twelve beams reinforced with GFRP and one beam with steel reinforcement of size $230{\times}300{\times}2000mm$ were investigated. Longitudinal reinforcement, shear span and spacing of stirrups were the main variables to form the set. In advanced testing three types of strain gauges for steel, composite and concrete surface were applied to observe strain/stress development against the applied load. Live data were recorded from four strain gauges applied on stirrups, one at center on longitudinal reinforcement, two on the concrete surface and central deflection during the test. Although the focus of the paper was mainly on the behavior of GFRP shear reinforcement, other parallel data were observed for the completeness of the test. Design recommendations of ISIS Canada Design Manual (2007), Japan Society of Civil Engineers (1997) and American Concrete Institute (ACI-440.1R-06) were reviewed. Shear design predictions were compared with experimental results in which it was observed that all the three standards provided conservative predictions. However, ACI found most efficient compare to other two there is room to improve the efficiency of the recommendations.

속채움 콘크리트 및 길이방향 철근으로 보강된 PHC 파일의 휨성능 (Flexural Performance of PHC Piles with Infilled concrete and Longitudinal Reinforcing Bars)

  • 한선진;이정민;김민석;김재현;김강수;오영훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권3호
    • /
    • pp.77-84
    • /
    • 2021
  • 이 연구에서는 속채움 콘크리트와 길이방향 철근으로 보강된 PHC 파일에 대한 휨실험을 수행하였으며, 실험의 주요 변수는 길이 방향 철근비와 PHC 파일 중공 내부 표면에 형성된 슬러지 유무로 설정하였다. 총 6개의 PHC 파일 실험체를 제작하였으며, 실험체들의 파괴모드, 균열패턴, 단면내 길이방향 변형률 분포, PHC 파일과 속채움 콘크리트 사이에 발생된 단부 슬립을 상세히 계측하고 분석하였다. 실험결과, 길이방향 철근비가 증가할수록 휨 강성 및 강도가 증가하는 것으로 나타났으며, PHC 파일 내부 표면에 형성된 슬러지는 실험체의 휨성능에 큰 영향을 미치지 않는 것으로 나타났다. 실험적 연구와 더불어 이 연구에서는 변형률 적합조건, PHC 파일과 속채움 콘크리트 단면내 변형률 및 응력 분포를 고려한 비선형 휨해석 모델을 제안하였으며, 해석결과를 실험결과와 비교하여 제안모델의 합리성을 검증하였다. 그 결과, 제안모델은 속채움 콘크리트와 길이방향 철근으로 보강된 PHC 파일의 휨거동을 매우 우수한 정확도로 평가하는 것으로 나타났다.

Rapid retrofit of substandard short RC columns with buckled longitudinal bars using CFRP jacketing

  • Marina L. Moretti
    • Earthquakes and Structures
    • /
    • 제24권2호
    • /
    • pp.97-109
    • /
    • 2023
  • This experimental study investigates the effectiveness of applying carbon fiber reinforced polymer (CFRP) jackets for the retrofit of short reinforced concrete (RC) columns with inadequate transverse reinforcement and stirrup spacing to longitudinal rebar diameter equal to 12. RC columns scaled at 1/3, with round and square section, were subjected to axial compression up to failure. A damage scale is introduced for the assessment of the damage severity, which focusses on the extent of buckling of the longitudinal rebars. The damaged specimens were subsequently repaired with unidirectional CFRP jackets without any treatment of the buckled reinforcing bars and were finally re-tested to failure. Test results indicate that CFRP jackets may be effectively applied to rehabilitate RC columns (a) with inadequate transverse reinforcement constructed according to older practices so as to meet modern code requirements, and (b) with moderately buckled bars without the need of previously repairing the reinforcement bars, an application technique which may considerably facilitate the retrofit of earthquake damaged RC columns. Factors for the estimation of the reduced mechanical properties of the repaired specimens compared to the respective values for intact CFRP-jacketed specimens, in relation to the level of damage prior to retrofit, are proposed both for the compressive strength and the average modulus of elasticity. It was determined that the compressive strength of the retrofitted CFRP-jacketed columns is reduced by 90% to 65%, while the average modulus of elasticity is lower by 60% to 25% in respect to similar undamaged columns jacketed with the same layers of CFRP.

외부부착 보강된 교량 바닥판 균열폭의 반경험적인 예측 (Semi-Empirical Prediction of Crack Width of the Strengthened Bridge Deck with External Bonding Plastic)

  • 심종성;오홍섭
    • 콘크리트학회논문집
    • /
    • 제14권2호
    • /
    • pp.231-238
    • /
    • 2002
  • 콘크리트 교량 바닥판은 건조수축 및 온도변화 등에 의하여 초기 1차균열이 발생하고, 사용기간 동안 반복되는 차량하중의 크기와 철근 간격 등에 의하여 초기 균열이 이방향 균열로 점차 발전하게 된다. 그러나 현재 사용되고 있는 대부분의 균열 예측식이 일방향 부착-슬립이론에 기초하고 있기 때문에 철근과 보강재의 간격에 따라 변화되는 교량 바닥판의 균열폭을 예측하고 보강된 바닥판의 사용성을 평가하기에는 많은 어려움이 있다. 따라서 본 연구에서는 시험결과에 기초하여 성능향상된 바닥판의 균열 메카니즘을 구명하였으며, 이로부터 사용성을 평가할 수 있는 새로운 균열예측식을 제안하였다. 제안된 균열예측식은 기존 균열식에 비하여 예측결과가 우수한 것으로 나타났으나, 철근 항복 이후 철근과 보강재의 변형률이 급격히 증가할 때 오차범위가 커지는 것으로 나타나 추가적인 연구가 필요한 것으로 판단된다. 따라서 보다나은 균열예측을 위해서는 피로 하중하에서의 철근 항복이후에 대한 추가적인 연구가 필요한 것으로 판단된다.

휨을 받는 압축강도 80 MPa 수준의 고강도 콘크리트 부재의 구조거동 실험 연구 (An Experimental Study on Structural Behavior of High-strength Concrete Members with Compressive Strength of 80 MPa Subjected to Flexure)

  • 양인환;황철성;김경철;조창빈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권4호
    • /
    • pp.1-12
    • /
    • 2017
  • 본 연구에서는 휨을 받는 압축강도 80 MPa 수준의 고강도 콘크리트 부재의 구조거동 실험 연구를 수행하였다. 실험변수는 보통(SD 400) 및 고강도(SD 600)철근, 0.98~1.58%의 종방향 철근비, $200{\times}250$, $200{\times}300mm$의 단면크기를 고려하였다. 9개의 보 부재를 제작하여 휨 실험을 수행하였으며 극한휨강도, 하중-처짐 관계, 균열 형태, 파괴형상 및 연성을 파악하였다. 실험결과는 철근비가 증가함에 따라 휨강도는 증가하고 연성은 감소한다. 또한, 철근비가 증가함에 따라 균열의 개수가 증가하며 균열폭은 감소하는 경향을 나타내었다. 철근의 강도 등급에 따른 하중-균열폭 관계는 뚜렷한 차이를 나타내지 않는다. 콘크리트 비선형거동 해석을 수행하였으며, 극한하중 예측값과 측정값을 비교하였다. 고강도 콘크리트의 휨거동 예측 결과는 실험부재의 휨강도를 전반적으로 과소평가하고 있다.

기계식 연속철근콘크리트포장의 현장 적용성 및 거동 분석 연구 (Field Application and Performance of Continuously Reinforced Concrete Pavement via Mechanical Tube-feeding Method)

  • 최훈석
    • 한국도로학회논문집
    • /
    • 제18권2호
    • /
    • pp.43-49
    • /
    • 2016
  • PURPOSES : The field application and performance of continuously reinforced concrete pavement (CRCP), constructed by using the mechanical tube-feeding method, are evaluated in this study. METHODS: The location of the rebar was evaluated by using the MIRA system. The early-age CRCP performance was evaluated via visual survey, in which the crack spacing and crack width were examined. RESULTS: The location of longitudinal reinforcing bars was evaluated via MIRA testing and the results showed that the longitudinal rebars all lie within a given tolerance limit (${\pm}2.5cm$) of the target elevation. In addition, owing to the low temperature when the concrete was pured, the crack spacing in the Dae-Gu direction is slightly wider than that of the Gwang-Ju direction. Almost all of the crack spacings lay within the range of 1.0 m~3.0 m. A crack width of <0.3 mm was measured at the pavement surface. However, as revealed by the field survey, the crack spacing was not correlated with the crack width. CONCLUSIONS : In CRCP constructed by using the mechanical tube-feeding method, almost all of the longitudinal reinforcing bars lay within the tolerance limit (2.5 cm) of the target elevation. The concrete-placing temperature affects the crack spacing, owing to variations in the zero-stress temperature. Crack survey results show that there is no correlation between the crack spacing and crack width in CRCP.

Seismic behaviour of RC columns with welded rebars or mechanical splices of reinforcement

  • Kalogeropoulos, George I.;Tsonos, Alexander-Dimitrios G.;Konstantinidis, Dimitrios
    • Earthquakes and Structures
    • /
    • 제17권3호
    • /
    • pp.297-306
    • /
    • 2019
  • The extension of existing RC buildings is a challenging process, which requires efficient connection between existing and new materials to guarantee load transferring between the lap-spliced longitudinal columns' reinforcement. Therefore, the length of the columns' starter bars is a crucial factor, which decisively affects the seismic response of the new columns. In particular, when the length of the starter bars is short, then the length of the lap splices of reinforcement is inadequate to ensure load transfer between steel bars and concrete, with an indisputable detrimental impact on the seismic behaviour of the columns. Moreover, in most of the existing RC buildings the column starter bars are of particularly short length, while they have probably been bent, cut or corroded. In the present study, the effectiveness of both welded rebar and mechanical splices of reinforcement in ensuring load transferring between the starter bars and the longitudinal reinforcement of the new column was experimentally evaluated. Four cantilever column subassemblages were constructed and subjected to earthquake-type loading. Three of the specimens were used to examine different types of shielded metal arc welding (SMAW), while in the fourth subassemblage mechanical splices were tested. The hysteretic response of the columns was evaluated and compared to the behaviour of a fifth specimen with continuous reinforcement, tested by Kalogeropoulos and Tsonos (2019). Test results clearly demonstrated that the examined types of SMAW were equally satisfactory in ensuring the ductile seismic performance of the columns, while the mechanical splices found to be more susceptible to exhibit slipping of the bars.

1축 인장시험을 통한 커플러가 철근 연성도에 미치는 영향 평가 (Evaluation of the Effect of Coupler on the Ductility of Rebar by Uniaxial Tensile Test)

  • 우태련;이종한;정진환;정치영
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권1호
    • /
    • pp.90-98
    • /
    • 2018
  • 최근 철근 콘크리트 구조물에 다양한 철근 이음이 사용되고 있다. 이에 따라 커플러 이음 철근의 인장 특성에 대한 파악이 중요해졌다. 본 연구에서는 커플러 이음 철근의 연성도에 대한 평가를 위하여 ASTM A615 기준에 따라 생산된 Grade 60 D22(#7), D29(#9), 그리고 두 종류의 커플러를 상대로 1축 인장시험을 수행하였다. 보다 정확하고 다양한 지점에서 자유로운 계측이 가능한 이미지 프로세싱 방법을 사용하여 변형률을 계측하였다. 1축 인장시험 결과, 응력-변형률 관계와 응력 단계별 종방향 변형률 분포를 산출할 수 있었고, 이를 통하여 동일한 표점거리 내에서 커플러 이음 부분이 많이 차지할수록 평균변형률이 낮아지는 것을 알 수 있었다. 또한 커플러 이음철근의 극한거동 및 파단 시변형률에 대한 평가를 통해 커플러의 길이에 대한 한계상태변형률과 파단변형률과의 상관관계를 정식화하였다.

공용중인 3-Arch터널의 열화조사 및 원인분석 (Analysis of cause and deterioration about using 3-Arch tunnel)

  • 이유석;박성우;황인백;신용석;김순곤
    • 한국터널지하공간학회 논문집
    • /
    • 제11권1호
    • /
    • pp.97-105
    • /
    • 2009
  • 3-Arch터널 시공초기인 1990년대 중반에 시공된 4개소의 3-Arch터널을 대상으로 열화발생여부를 조사하였으며, 그 결과 4개 터널 모두 중앙기둥측 상, 하선 아치부에서 발생형태가 유사한 종방향 균열이 조사되었다. 4개 터널 줄 3개소의 터널에서는 종방향 균열의 발생빈도가 높고 1개의 터널에서는 종방향 균열의 발생빈도가 낮아 이 2개군의 시공과정상 차이점을 분석하였으며 비파괴시험 및 정밀육안조사, 지반조건이 취약한 1개의 터널을 대상으로 안전성평가를 실시하여 이러한 열화들의 원인과 이에 따른 안전성여부를 판단하였다. 그 결과 안전성은 확보되었으며 중앙터널 기둥측 상, 하선아치부에 발생한 열화는 중앙터널굴착에 앞서 선시공되는 상, 하선 콘크리트라이닝의 철근배근불량과 이후의 시공단계인 중앙터널 굴착시의 영향이 큰 것으로 분석되었다.

내부충전 콘크리트와 횡보강 및 축방향 철근으로 보강된 PHC 말뚝의 휨강도 (Flexural Strength of PHC Pile Reinforced with Infilled Concrete, Transverse and Longitudinal Reinforcements)

  • 방진욱;현정환;이방연;이승수;김윤용
    • 콘크리트학회논문집
    • /
    • 제25권1호
    • /
    • pp.91-98
    • /
    • 2013
  • PHC 말뚝은 우수한 축하중 저항 능력에 비해 상대적으로 전단 및 휨 저항 성능이 낮은 단점을 가지고 있다. 이 연구의 목적은 기존 PHC 말뚝의 단점을 개선할 목적으로 개발된 중공부에 내부충전 콘크리트, 축방향 철근과 전단 철근으로 보강한 합성 PHC 말뚝(ICP 말뚝)의 휨성능을 평가하는 것이다. 이를 위하여 기존의 교대 설계사례로 부터 말뚝에 발생하는 축력과 휨모멘트를 조사한 후, ICP 말뚝 계산을 위하여 개발한 축력-휨모멘트 상관관계 프로그램을 이용하여 허용 축력과 휨모멘트가 발생하는 부재력을 만족하도록 ICP 말뚝을 설계하였다. 설계에 따라 ICP 말뚝을 제작하였으며, 휨실험을 수행하였다. 실험 결과 ICP 말뚝은 PHC 말뚝에 비하여 약 45% 큰 휨내력을 나타내었다. 또한 계산에 의해 예측한 ICP 말뚝 휨강도의 25%를 허용 휨모멘트로 취할 경우, 약 4.5의 안전율을 갖는 것으로 평가되었다.