• Title/Summary/Keyword: long-wave radiation

Search Result 97, Processing Time 0.126 seconds

열대 해양의 해수면온도와 구름의 상호관계 (Interrelationships between Sea Surface Temperatures and Clouds over the Tropical Oceans)

  • 송봉근;김영섭;박경원
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2001년도 춘계 학술대회 논문집 통권 4호 Proceedings of the 2001 KSRS Spring Meeting
    • /
    • pp.92-97
    • /
    • 2001
  • The intra-annual and interannual variations of total, high, middle, low clouds, and cloud forcing net solar radiation flux, cloud forcing net long-wave radiation flux, and SSTs over the tropical oceans are investigated with the use of ISCP D2, NCEP/NCAR Reanalysis for January 1983-December 1993. The intra-annual variation of total cloudiness is dominated by high and middle clouds in the western Pacific and central tropical oceans, the interannual variation of total cloudiness is also dominated by high and middle clouds in the central Pacific and Atlantic. The dominant intra-annual and interannual EOFs of total cloudiness have spatially coherent link with those SSTs. For the interannual EOFs, total cloudiness and SSTs are related to E1 nino-Southern Oscillation(ENSO). The second most important intra-annual EOFs of total cloudiness are related to Inter Tropical Convergence Zone(ITCZ). The third most important intra-annual EOFs show coherent relation in the western Pacific. The correlation analysis between cloud radiative effects and SSTs show spatially coherent relation over the tropical oceans even though cloud forcing cooling effect is much higher than heating effect.

  • PDF

관측에 의한 옥상 수공간의 자연냉각효과 평가 (Evaluation of Passive Cooling Effect on Roof Pond through Field Observation)

  • 정성진;최동호;이부용
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.85-89
    • /
    • 2008
  • This study carried out field observations of measuring thermal environment, especially evaluating amount of water evaporation at roof Pond by field observations during the summer. Thermal environment measuring was categorized as air temperature, water temperature of roof pond, surface temperature, globe temperature, short and long wave radiation, net radiation, and amount of water evaporation by water level measurement. Results from this study could be used as fundamental for reducing heat Island phenomena.

  • PDF

수면파와 저면흡수가 고려된 댐 지진응답해석을 위한 전달경계 (Transmitting Boundary for the Seismic Response Analysis of Dam including surface sloshing and Bottom Absorption)

  • 김재관
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1998년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.180-187
    • /
    • 1998
  • One of the major difficulties in the seismic analysis of a dam-reservoir system is the treatment of the energy radiation in the upstream direction of the reservoir. In this paper a new transmitting boundary is presented that can model properly the radiation of energy in the far field direction of a semi-infinite reservoir with constant depth. In the newly developed method, effects of surface wave motion are taken into account and the reservoir-foundation interaction is approximately accounted for with an absorbing boundary condition. If a dam has vertical upstream face and the infinitely long reservoir maintains constant depth, then the proposed transmitting boundary can be directly coupled with the model of dam body. In present study, the dam body is assumed to behave elastically and modeled by finite element method. Seismic responses of a dam model are investigated using the newly developed transmitting boundary.

  • PDF

PZT를 이용한 계면 교차 방향 방사형 마이크로믹서 (Cross-sectional radiation type micromixer to mixed interface using PZT)

  • 허필우;김덕종;김재윤;박상진;윤의수;고광식
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.121-125
    • /
    • 2003
  • Micromixer plays an important role in Bio-MEMS or ${\mu}-TAS$. Mixing is generally generated by turbulence and interdiffusion of two fluids. Because of low Reynolds number(Re << 2000) in ${\mu}-channel$, it is difficult to generate turbulence, so mixing mainly depends on interdiffusion. Thus long channel distance is required to mix two different fluids. To reduce the channel length required for mixing, we propose the a new active ${\mu}-mixer$ that two fluids are effectively mixed in ${\mu}-channel$ by the ultrasonic wave which is generated by PZT. The ultrasonic wave is radiated into a chamber in the cross-section directional direction to interface with the two fluids. The two fluids are positioned one on top of the other. Mixing state is measured by the changing of color due to the reaction of NaOH and phenolphtalein.

  • PDF

동지나해의 열속추정에 관한 연구 (Estimate of Heat Flux in the East China Sea)

  • 김영섭
    • 한국수산과학회지
    • /
    • 제29권1호
    • /
    • pp.84-91
    • /
    • 1996
  • 각종 해${\cdot}$기상 자료와 위성관측에 의한 운량 자료를 이용하여 벌크법에 의해 동지나해에 있어서 대기와 해양간의 열속을 추정하였으며, 그 결과를 요약하면 다음과 같다. 1) 태양복사량은 5월에 $255Wm^{-2}$로 최대, 12월에 $111Wm^{-2}$로 최소이며, 그 분포는 동절기에는 남쪽으로 갈수록 증가하고, 하절기에는 장마전선의 영향으로 북쪽으로 갈수록 증가하는 경향이 있었다. 장파복사량의 경우, 공간적 분포의 차이는 작으나 계절에 따른 차이는 커서 최대인 2월의 값은 (약 $70Wm^{-2}$) 최소인 7월의 2배에 이른다. 2) 현열과 잠열의 공간적 분포양상은 조사해역내의 해류 분포와 비슷하였다. 겨울철에 이 두 요소에 의한 해양의 열손실량은 대단히 커서 $830Wm^{-2}$ 이상이고, 이것은 같은 기간중 순폭사량의 5배에 이른다. 3) 연평균 순열플럭스의 분포는 전역에서 부 값을 보였으며, 최대 열손실 해역은 큐슈 남단으로 1월에 $400Wm^{-2}$ 이상이었다. 4) 조사해역의 태양복사량, 장파복사량, 현열 및 잠열의 연평균치는 각각 187, -52, -30, $-137Wm^{-2}$이고, 결과적으로 연간 약 $32Wm^{-2}(2.48\times10^{13}\;W)$의 에너지를 손실하고 있는 것으로 추정되었다. 5) Fig. 1에 표시되어 있는 A 해역 (황해)은 대기와의 열교환을 통하여 오히려 연간 $10Wm^{-2}(0.4\times10^{13}\;W)$의 에너지를 얻고, B 해역 (동지나해)은 $48Wm^{-2}(2.1\times10^{13}\;W)$,그리고 C 해역 (쿠로시오역)은 $39Wm^{-2}(1.7\times10^{13}\;W)$의 열을 손실하고 있는 것으로 추정되었다.

  • PDF

내측 블라인드의 하절기 일사열 차폐 성능 비교 (Comparing Solar Heat Shading Performances of Internal Blinds in the Summer)

  • 박은미;최동호;박민용;이경희
    • 한국태양에너지학회 논문집
    • /
    • 제34권6호
    • /
    • pp.75-83
    • /
    • 2014
  • Heat loss through windows and doors occupies 20 to 45% of the total heat loss in building. It accounts for a large proportion of the total heat loss in building. In order to suppress the amount of heat flow through the windows and doors were considered actions such as reinforcement of insulation performance of window, adoption of low-e glass, and installation of solar heat shading device. The Purpose of this study is to compare solar heat shading performances of 3 types of internal blinds in the summer. In order to verify the solar heat shading performances of the blinds, a roll blind, blind A(Venetian blind) and blind B(Daylight guiding venetian blind)were installed in the four rooms with the same environmental conditions. As a result of the experiment, the blind B, blind A, roll blind showed an excellent performance in that order. Its because the blind B is made of aluminum materials coated with special paints on surface. It doesn't converted to long wave by short wave light. and it is reflected to short wave to outside.

무배전기식 불꽃 점화 시스템에서 복사되는 전자파의 전력 스펙트럼 분석 (Analysis on the Power Spectrum of Electromagnetic Waves Radiating from the Distributorless Spark Ignition System)

  • 최광제;조시기;정원락;장성국;강신한
    • 한국자동차공학회논문집
    • /
    • 제16권1호
    • /
    • pp.45-51
    • /
    • 2008
  • This paper presents theoretical and experimental analysis on the characteristics of the power spectrum of electormagnetic waves radiating from the spark plug and their cables of a distributorless ignition system. The theoretical study was conducted applying the microwave transmission line theory and the antenna theory. The experimental works were carried out to measure the standing wave ratio(SWR) and the radiation power spectrum of this system. As a result, it has been found that a spark plug and its cable is working as a monopole antenna radiating elelctromagnetic waves. Because of its similar structure to a monopole antenna, the envelope of radiation power spectrum distribution has a bell shape which can be obtained from a monopole antenna operating as a series resonant circuit. The frequency characteristics from the SWR measurements show a similar frequency characteristics of power spectrum of the system studied. Also, it has been found that the density of the power spectrum of the system fitting a long time used spark plug is higher than that of fitting a new spark plug.

낙동강 강정고령보의 여름철 열수지 일변화 - 열 저장량 변동을 중심으로 - (Daily Variation of Heat Budget Balance in the Gangjeong-Goryung Reservoir for Summertime - Concerning around the Rate of Heat Storage -)

  • 김성락;조창범;김해동
    • 한국환경과학회지
    • /
    • 제24권6호
    • /
    • pp.721-729
    • /
    • 2015
  • Surface heat balance of the Gangjeong-Goryung Reservoir is analyzed for 12-17 August 2013. Each flux elements at the water surface is derived from the special field observations with application of an aerodynamical bulk method for the turbulent heat fluxes and empirical formulae for the radiation heat fluxes. The rate of heat storage in the reservoir is estimated by using estimated by surface heating rate and the vertical water temperature data. The flux divergence of heat transport is estimated as a residual. The features of the surface heat balance are almost decided by the latent heat flux and the solar radiation flux. On average for 12-17 August 2014 in the Gangjeong- Goryung Reservoir, if one defines the insolation at the water surface as 100 %, 94 % is absorbed in the reservoir; thereafter the reservoir loses about 30~50% by sensible heat, latent heat and net long-wave radiation. The residue of 50~80 % raises the water temperature in the reservoir or transported away by the river flow during the daytime.

Development of a Guided Wave Technique for the Inspection of a Feeder Pipe in a Pressurized Heavy Water Reactor

  • Cheong, Yong-Moo;Lee, Dong-Hoon;Kim, Sang-Soo;Jung, Hyun-Kyu
    • Corrosion Science and Technology
    • /
    • 제4권3호
    • /
    • pp.108-113
    • /
    • 2005
  • One of the recent safety issues in the pressurized heavy water reactor (PHWR) is the cracking of the feeder pipe. Because of the limited accessibility to the cracked region and a high dose of radiation exposure, it is difficult to inspect all the pipes with the conventional ultrasonic method. In order to solve this problem, a long-range guided wave technique has been developed. A computer program to calculate the dispersion curves in the pipe was developed and the dispersion curves for the feeder pipes in PHWR plants were determined. Several longitudinal and/or flexural modes were selected from the review of the dispersion curves and an actual experiment has been carried out with the specific alignment of the piezoelectric ultrasonic transducers. They were confirmed as L(0,1)) and/or flexural modes(F(m,2)) by the short time Fourier transformation(STFT) and were sensitive to the circumferential cracks, but not to the axial cracks in the pipe. An electromagnetic acoustic transducers(EMAT) was designed and fabricated for the generation and reception of the torsional guided wave. The axial cracks were detected by a torsional mode(T(0,1)) generated by the EMAT.

An effective finite element approach for soil-structure analysis in the time-domain

  • Lehmann, L.
    • Structural Engineering and Mechanics
    • /
    • 제21권4호
    • /
    • pp.437-450
    • /
    • 2005
  • In this study, a complete analysis of soil-structure interaction problems is presented which includes a modelling of the near surrounding of the building (near-field) and a special description of the wave propagation process in larger distances (far-field). In order to reduce the computational effort which can be very high for time domain analysis of wave propagation problems, a special approach based on similarity transformation of the infinite domain on the near-field/far-field interface is applied for the wave radiation of the far-field. The near-field is discretised with standard Finite Elements, which also allows to introduce non-linear material behaviour. In this paper, a new approach to calculate the involved convolution integrals is presented. This approximation in time leads to a dramatically reduced computational effort for long simulation times, while the accuracy of the method is not affected. Finally, some benchmark examples are presented, which are compared to a coupled Finite Element/Boundary Element approach. The results are in excellent agreement with those of the coupled Finite Element/Boundary Element procedure, while the accuracy is not reduced. Furthermore, the presented approach is easy to incorporate in any Finite Element code, so the practical relevance is high.