• Title/Summary/Keyword: long-range inspection

Search Result 75, Processing Time 0.034 seconds

Mode Selection of Leaky Lamb Waves in Steel Plate

  • Lee, Ju-Won;Kim, Jeong-Tae;Cho, Hyun-Man;Na, Won-Bae
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.6-12
    • /
    • 2008
  • The dispersion and attenuation of Lamb and Leaky Lamb waves propagating in a 1 mm-thick steel plate were investigated. For acquiring a long(or large) range inspection capability, the fundamental symmetric and anti-symmetric wave modes(S0 and A0) over law frequencies were studied. Based on the dispersion curves, as well as pitch-catch and multi-mode simulations, it was shown that the S0 mode over law frequencies is the proper mode to minimize the dispersion and attenuation. In addition, it was shown that the S0 mode couldbe easily distinguished under multi-mode simulation since it has a larger group velocity than the A0 mode.

Gabor Pulse-Based Matching Pursuit Algorithm : Applications in Waveguide Damage Detection (가보 펄스 기반 정합추적 알고리즘 : 웨이브가이드 결함진단에서의 응용)

  • 선경호;홍진철;김윤영
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.969-974
    • /
    • 2004
  • Although guided-waves are very efficient for long-range nondestructive damage inspection, it is not easy to extract meaningful pulses of small magnitude out of noisy signals. The ultimate goal of this research is to develop an efficient signal processing technique for the current guided-wave technology. The specific contribution of this investigation towards achieving this goal, a two-stage Gabor pulse-based matching pursuit algorithm is proposed : rough approximations with a set for predetermined parameters characterizing the Gabor pulse and fine adjustments of the parameters by optimization. The parameters estimated from the measured signal are then used to assess not only the location but also the size of a crack existing in a rod. To validate the effectiveness of the proposed method, the longitudinal wave-based damage detection in rods is considered. To estimate the crack size, Love's theory for the dispersion of longitudinal waves is employed.

  • PDF

Application of Thin-Walled Tubes Using Guided Wave (유도초음파를 이용한 대구경 배관 적용에 관한 연구)

  • Park, S.K.;Lee, Y.H.
    • Journal of Power System Engineering
    • /
    • v.12 no.1
    • /
    • pp.58-65
    • /
    • 2008
  • A method to test thin-walled tubes by guided ultrasonic wave is reported. The principle is that applicate two types of axially symmetric ultrasonic tube modes and "longitudinal" modes with particle displacement, which is coupled in axial and radial directions for transverse failures and torsional modes, oscillating in the circumferential direction only, for longitudinal failures. Both types of modes propagate along the tube in the axial direction. Therefore, a pulse-echo technique is possible. The pulses are excited and received at one end of the tube without contact electro-dynamic transducers. As soon as the tubes is put into a transducer coil at one end, the test of the whole tube can be accomplished in a few milliseconds. It is not necessary to rotate and transport the tubes during the test.

  • PDF

Development of Short-Run Standardized Control Charts and Acceptance Control Charts Classified by the Demand Volume and Variety (수요량과 다양성 패턴에 의해 유형화된 단기간 표준화 관리도와 단기간 합격판정 관리도의 개발)

  • Choi, Sung-Woon
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.255-263
    • /
    • 2010
  • The research developes short-run standardized control charts(SSCC) and short-run acceptance control charts(SACC) under the various demand patterns. The demand patterns considered in this paper are three types such as high-variety and repetitive low-volume pattern, extremely-high-variety and nonrepetitive low-volume pattern, and high-variety and extremely-low-volume pattern. The short-run standardized control charts developed by extending the long-run ${\bar{x}}$-R, ${\bar{x}}$-s and I-MR charts have strengths for practioners to understand and use easily. Moreover, the short-range acceptance control charts developed in the study can be efficiently used through combining the functions of the inspection and control chart. The weighting schemes such as Shewhart, moving average (MA) and exponentially weighted moving average (EWMA) can be considered by the reliability of data sets. The two types according to the use of control chart are presented in the short-range standardized charts and acceptance control charts. Finally, process capability index(PCI) and process performance index(PPI) classified by the demand patterns are presented.

Inspection on the Influence of Asian Dust on the Distribution of Atmospheric Mercury Observed for a Long Time (장기간 관측을 통한 황사 현상이 수은의 분포에 미치는 영향 고찰)

  • Lee, Jeong-Soon;Kim, Min-Young;Kim, Ki-Hyun;Hong, S.M.;Son, Z.H.;Lee, S.C.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.2
    • /
    • pp.169-182
    • /
    • 2007
  • To evaluate the possibly potent role of Asian Dust (AD) on the long range transport of Hg, statistical analyses were carried out using the hourly concentration data of gaseous elemental mercury (Hg) along with relevant environmental parameters. For the purpose of this study, Hg data were collected from Yang-Jae monitoring station in Seoul, Korea during Sept. 1997 to June 2002. During the study period, Hg concentrations in non-AD period ranged from $0.03\;to\;32.70\;ng\;m^{-3}$ with a mean $5.27{\pm}3.06\;ng\;m^{-3}$, while those in AD period from $1.79\;to\;32.60\;ng\;m^{-3}$ with a mean $5.20{\pm}3.06\;ng\;m^{-3}$. The air quality during AD were typically deteriorated by enhanced PM10 mass concentration (by $2{\sim}5$ times) compared to non-AD period, however comparison of the Hg concentration data indicates that they are not critically distinguished between events of AD and non-AD, except for the high minimum level of Hg during AD. The results of correlation and factor analysis also indicated somewhat complex patterns; in the case of AD events, Hg and $SO_{2}$ were assorted concurrently into a same factor. Evidence collected from this study thus suggests that long-range transport of Hg, if occurring, is unlikely to raise statistically Hg concentration levels such as seen during AD event. However, in nighttime of winter season, Hg concentrations are higher during AD (along with PM10 levels) than non-AD period. Although such observations suggest the effect of long range transport on the enhancement of Hg concentrations, more deliberate analysis may be required to track down the effect of such mechanism in relation with various factors including the air mass transport route.

Quantitative Evaluation of Remote Field Eddy Current Defect Signals (배관 결함부 원거리장 와전류 신호 정량화 연구)

  • Jeong, Jin-Oh;Yi, Jae-Kyung;Kim, Hyoung-Jean
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.555-561
    • /
    • 2000
  • The remote field eddy current (RFEC) inspection was performed on the ductile cast iron pipes with nominal outer diameter of 100mm, which were machined with various shapes and sizes of defects. Ductile cast iron pipes which are used as water supply pipe have the non-uniform thickness and asymmetric cross section due to relatively high degree of allowable errors during the manufacturing processes. These characteristics of ductile cast in pipes cause the long range background noises in RFEC signals along the pipe. In this study, tile machined defects in pipes were effectively classified by the moving window average (MWA) method which eliminated the long-range noise. The voltage plane polar plots (VPPP) method was used to quantitatively evaluate the depth and circumferential degree of defects. The VPPP signatures showed that the angle between defect signature and the normalized in-phase component on the VPPP is linear to the depth of defects. The nondestructive RFEC technique proved to be capable of quantitatively evaluating the machined defects of underground water supply pipe.

  • PDF

Evaluation of Short and Long-Term Modal Parameters of a Cable-Stayed Bridge Based on Operational Modal Analysis (운용모드해석에 기반한 사장교의 장단기 동특성 평가)

  • Park, Jong-Chil
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.4
    • /
    • pp.20-29
    • /
    • 2022
  • The operational modal analysis (OMA) technique, which extracts the modal parameters of a structural system using ambient vibrations, has been actively developed as a field of structural health monitoring of cable-supported bridges. In this paper, the short and long-term modal parameters of a cable-stayed bridge were evaluated using the acceleration data obtained from the two ambient vibration tests (AVTs) and three years of continuous measurements. A total of 27 vertical modes and 1 lateral mode in the range 0.1 ~ 2.5 Hz were extracted from the high-resolution AVTs which were conducted in the 6th and 19th years after its completion. Existing OMA methods such as Peak-Picking (PP), Eigensystem Realization Algorithm with Data Correlation (ERADC), Frequency Domain Decomposition (FDD) and Time Domain Decomposition (TDD) were applied for modal parameters extraction, and it was confirmed that there was no significant difference between the applied methods. From the correlation analysis between long-term natural frequencies and environmental factors, it was confirmed that temperature change is the dominant factor influencing natural frequency fluctuations. It was revealed that the decreased natural frequencies of the bridge were not due to changes in structural performance and integrity, but to the environmental effects caused by the temperature difference between the two AVTs. In addition, when the TDD technique is applied, the accuracy of extracted mode shapes is improved by adding a proposed algorithm that normalizes the sequence so that the autocorrelations at zero lag equal 1.

A study on the Muscle Activity and Fatigue between Quadriceps Femoris Muscle during the Mode Shift of Contraction (수축모드 변화에 따른 대퇴사두근의 근 활성도와 근 피로도에 관한 연구)

  • Chon, Ki-Hwan;Yang, Dong-Il;Lee, Gwi-Yeol
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.6
    • /
    • pp.1152-1162
    • /
    • 2011
  • This study was function experiment or inspection of diagnosis x-ray unit at the hospital. It's how many changes tube voltage, tube current, DOSE value through the experiment depending on temperature increasing. The study want to know whether which parameter shown out of range or not how about image quality and so on. Increasing tube current and DOSE were not only too many radiation to the patient and radiation workers and make bad images but also the tube should be damaged by heat. This study was recommended proper exposure at intervals of seconds because passed inspection, reduced radiations for patient and the tube used long term. This results in the hospital's finances will be very helpful.

A Study of x-ray tube voltage, tube current and dose rate depeding on temperature (온도 변화에 따른 X-선진단장치의 관전압, 관전류, 조사선량에 관한 연구)

  • Chon, Ki-Hwan;Hwang, Min-Seon;Choi, Myeon-Woong;Lee, Song-Yi;Kim, Min-Ji;Yang, Dong-Il;Lee, Gwi-Yeol
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.2
    • /
    • pp.264-272
    • /
    • 2011
  • This study was function experiment or inspection of diagnosis x-ray unit at the hospital. It's how many changes tube voltage, tube current, DOSE value through the experiment depending on temperature increasing. The study want to know whether which parameter shown out of range or not how about image quality and so on. Increasing tube current and DOSE were not only too many radiation to the patient and radiation workers and make bad images but also the tube should be damaged by heat. This study was recommended proper exposure at intervals of seconds because passed inspection, reduced radiations for patient and the tube used long term. This results in the hospital`s finances will be very helpful.

Mechanical Properties of Ultra High Strength Concrete Using Ternary Blended Cement (3성분계 혼합시멘트를 사용한 초고강도 콘크리트의 역학적 특성)

  • Kim, Jin Bong;Shin, Ki Su;Park, Ki Bong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.6
    • /
    • pp.56-62
    • /
    • 2012
  • The results presented in this paper form part of an investigation into the optimization of a ternary blended cementitious system based on ordinary Portland cement (OPC)/blast furnace slag(BFS)/fly ash(FA) for the development of ultra high strength concrete. Concrete covering a wide range of BFS/FA blending proportions were investigated. Compressive strength at the ages of 3, 7 and 28 days for concrete specimens containing 0%, 10%, 20% and 30%FA along with 0%, 30%, 40% and 50%BFS as partial cement replacement at a water-binder ratio of 0.18 were investigated. Tests on porosity and pore size distribution were conducted using mercury intrusion porosimetry. The results show that the combination of FA10 and BFS30 can improve both short- and long-term properties of concrete as results of reducing of pores larger than 50nm.