• 제목/요약/키워드: long-range inspection

검색결과 75건 처리시간 0.056초

Long-Range Guided Wave Inspection of Structures Using the Magnetostrictive Sensor

  • Kwun, He-Geon;Kim, Sang-Young;Light, Glenn M.
    • 비파괴검사학회지
    • /
    • 제21권4호
    • /
    • pp.383-390
    • /
    • 2001
  • Long-range guided wave inspection is a new emerging technology for rapidly and globally inspecting a large area of a structure from a single test location. This paper describes a general overview of the guided wave properties and its application for long-range inspection of structures the principle and instrument system for a guided wave inspection technology called "magnetostrictive sensor (MsS)" that generates and detects guided waves electromagnetically in the material under testing, and examples of long-range guided wave inspection of structures that can be accomplished using the MsS.

  • PDF

유도초음파를 이용한 장거리 배관 탐상기법 (Long Range Ultrasonic Guided Wave Techniques for Inspection of Pipes)

  • 박익근;김용권;김현묵;송원준;조용상;안연식
    • Journal of Welding and Joining
    • /
    • 제23권5호
    • /
    • pp.43-48
    • /
    • 2005
  • Conventional non-destructive techniques for inspection of the weld in pipelines require significant test time and high cost. Ultrasonic guided waves have been widely studied and successfully applied to various non-destructive tests with advantage of the long-range inspection. In this paper, a study on the application of ultrasonic guided waves to the long-range inspection of the pipeline is presented using a long-range guided wave inspection system, Wavemaker SE16, GUL. The characteristics and setup of the long-range guided wave inspection system and experimental results in pipes of with various diameter are introduced. The experimental results in mock-up pipes with cluster type detects show that the minimum detectable wall thickness reduction with this guided wave system is $2\~3\%$ in the pipe cross section area. And the wall thickness reduction of $5\%$ in cross section area can be detected when actual detection level is used. Therefore, the applicability of the guided wave systeme to long-range inspection of wall thickness reduction in pipes is verified.

Long Range Cylindrically Guided Ultrasonic Wave Technique for Inspection

  • Balasubramaniam, Krishnan
    • 비파괴검사학회지
    • /
    • 제23권4호
    • /
    • pp.364-371
    • /
    • 2003
  • In this paper, a review of the current status, on the use of long range cylindrically guided wave modes, and their interaction with cracks and corrosion damage in pipe-like structures will be discussed. Applications of cylindrically guided ultrasonic wave modes have been developed for inspection of corrosion damage in pipelines at chemical plants, flow-accelerated corrosion damage (wall thinning) in feedwater piping, and circumferential stress corrosion cracks in PWR steam generator tubes. It has been demonstrated that this inspection technique can be employed on a variety of piping geometries (diameters from 1 in. to 3 ft, and wall thickness from 0.1 to 6 in.) and a propagation distance of 100 meters or more is sometimes feasible. This technique can also be used in the inspection of inaccessible or buried regions of pipes and tubes.

유도파 기반 장거리 파이프라인 검사를 위한 모니터링 센서의 위치결정 (Determinating Sensor Location for Guided-Wave-Based Long Range Pipeline Inspection)

  • 나원배;류연선;김정태
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.232-239
    • /
    • 2006
  • Guided wave techniques have been used for pipeline inspection because of the long range inspection capability of guided waves. One of main concerns of these technique is how ones decide the axial interval of sensors when they are utilized for pipeline inspection. This question is related to the characteristic of cylindrical guided wave propagation, especially wave attenuation. Thus, attenuation of fundamental longitudinal guided wave propagating liquid-filled steel pipes is numerically investigated in the paper. Several liquids such as water, diesel oil, castor oil etc. are considered for the filing materials in the pipes. Sink is considered for numerical models for abandoning standing wave modes; hence, the attenuation dispersion curves become much simpler. Those attenuation calculations can be utilized for guided-wave-based nondestructive testing of pipelines when one inspects pipelines, using monitoring sensors, which are installed outside pipes.

  • PDF

배관 원거리 진단을 위한 원주방향 배열 유도초음파 집속기술 개발 (A Study on Techniques for Focusing Circumferential Array Guided Waves for Long Range Inspection of Pipes)

  • 강토;김학준;송성진;조영도;이동훈;조현준
    • 비파괴검사학회지
    • /
    • 제29권2호
    • /
    • pp.114-121
    • /
    • 2009
  • 유도초음파는 현재 산업설비의 배관 등 장거리 탐상에 널리 사용되고 있으며, 특히, 길이가 수백 미터에서 수 km에 달하는 가스 배관의 검사를 위하여 다수의 탐촉자를 이용한 배열 유도초음파 기술의 개발 및 적용이 확대되고 있다. 따라서, 본 연구에서는, 배관의 원거리 검사능 및 정밀도 향상을 위하여 배열 유도초음파의 집속 알고리즘을 개발하였으며, 개발 알고리즘의 성능을 개발 배열 초음파 시스템을 이용한 실험을 통하여 검증하였다. 그 결과 집속 알고리즘을 적용한 배열 유도초음파의 신호대 잡음비(SNR : signal to noise ratio)가 집속 알고리즘을 적용하지 않은 경우에 비해 향상됨을 알 수 있었다.

레일 초음파의 분산 특성 해석 (Analysis of Dispersion Characteristics of Guided Waves in Rails)

  • 강부병
    • 대한기계학회논문집A
    • /
    • 제35권10호
    • /
    • pp.1257-1264
    • /
    • 2011
  • 짧은 시간에 장거리를 전파하는 유도 초음파의 특성을 이용하면 빠르게 넓은 영역의 검사가 가능하다. 그러나 레일의 경우와 같이 단면이 단순하지 않고 임의의 형상을 갖는 구조물의 경우 초음파 전달시 발생하는 분산 특성이나 다수의 모드의 발생으로 초음파 신호의 분석에 어려움을 겪는다. 따라서 실용적인 유도 초음파 검사 시스템을 개발하기 위해서는 먼저 레일내를 전파하여 전달되는 초음파의 거동특성을 이해하여야 한다. 특히 레일내를 전파하는 초음파의 분산특성은 필수적으로 확인되어야 할 특성이다. 본논문에서는 SAFE법을 활용하여 KS60 레일내를 전파하는 초음파의 분산곡선을 구하는 방법을 소개하고 유도초음파를 활용한 레일 검사의 가능성에 대하여 살펴보았다.

선별형 2회 샘플링 검사방식의 최적설계를 위한 알고리즘 개발 (An Algorithm for Determining Double Rectifying Inspection Plans)

  • 강보철;조재립
    • 품질경영학회지
    • /
    • 제24권4호
    • /
    • pp.207-223
    • /
    • 1996
  • These days, customers have attached great importance to the function of product liability and quality assurance. In Korea, the single rectifying sampling inspection for attribute (KS A 3105) has been used. But this inspection plan given by tables (KS A 3105) has some defects. There are limitations in the range of applications and irrationality of approximate probability and the double rectifying sampling inspection is not mentioned. Moreover, ATI (average total inspection) does not reflect sampling costs and the loss of nonconforming item. Therefore, the objectives of this study is to develope new algorithms and computer program that provide the optimal sampling inspection plan based on minimum linear costs (single & double inspection plan). The result of this study revealed that the new algorithm is less than KS A 3105 in ATI and basically, double inspection plan is more economical. Also it comes over restrictions in KS A 3105. So, it is definite that the optimal solution can be obtained considering cost factors in manufacturing and sampling process, and costs can be saved in the long term.

  • PDF