• 제목/요약/키워드: long tooth

검색결과 398건 처리시간 0.024초

Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating

  • Bacchi, Atais;Regalin, Alexandre;Bhering, Claudia Lopes Brilhante;Alessandretti, Rodrigo;Spazzin, Aloisio Oro
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권5호
    • /
    • pp.375-379
    • /
    • 2015
  • PURPOSE. The purpose of this study was to evaluate the influence of tightening technique and the screw coating on the loosening torque of screws used for Universal Abutment fixation after cyclic loading. MATERIALS AND METHODS. Forty implants (Titamax Ti Cortical, HE, Neodent) (n=10) were submerged in acrylic resin and four tightening techniques for Universal Abutment fixation were evaluated: A - torque with 32 Ncm (control); B - torque with 32 Ncm holding the torque meter for 20 seconds; C - torque with 32 Ncm and retorque after 10 minutes; D - torque (32 Ncm) holding the torque meter for 20 seconds and retorque after 10 minutes as initially. Samples were divided into subgroups according to the screw used: conventional titanium screw or diamond like carbon-coated (DLC) screw. Metallic crowns were fabricated for each abutment. Samples were submitted to cyclic loading at $10^6$ cycles and 130 N of force. Data were analyzed by two-way ANOVA and Tukey's test (5%). RESULTS. The tightening technique did not show significant influence on the loosening torque of screws (P=.509). Conventional titanium screws showed significant higher loosening torque values than DLC (P=.000). CONCLUSION. The use of conventional titanium screw is more important than the tightening techniques employed in this study to provide long-term stability to Universal Abutment screws.

심미와 기능 회복을 위한 교정- 라미네이트 수복 치료 증례 (Case report: Laminate prosthesis with orthodontic treatment for achieve anterior esthetics and functional occlusion)

  • 이한나
    • 대한심미치과학회지
    • /
    • 제23권2호
    • /
    • pp.80-85
    • /
    • 2014
  • 가지런한 치열을 얻기 위해 교정 치료는 치아 보존적인 의미에서 단연 First choice가 일 수 밖에 없다. 그러나 왜소치나 치아 크기의 불균형인 경우, 변색 치아나 파절, 심한 마모 치아인 경우 교정만으로는 심미적으로 완성도 높은 결과를 가져올 수 없다. 모든 치료에서 그러하지만, 특히 심미 치료에서는 치아 교정과 보철 치료, 혹은 치주 치료 및 임플란트등 항상 통합적인 진단과 치료계획이 필요한 경우가 많다. 그리고 다양한 치과 분야의 협진 진료가 필요한 환자에서는 안모와 치아의 심미적 만족뿐 아니라 기능적인 교합관계를 이룸으로써 장기간 안정적이며 조화로운 상태가 유지될 수 있는 치료가 전제되어야 한다. 본 증례는 전치부와 소구치에 cross bite가 있고, 상악 우중절치 절단에 마모가 있는 37세 여성 환자에서 교정과 라미네이트 수복치료를 동반한 경우이다. 치아교정을 통하여 전체적인 치아 위치를 재구성하여 기능교합을 이루었고, 최소한의 치질삭제로 라미네이트 수복치료를 함으로써 전치부 심미를 회복하였다. 최종 보철물을 장착하고 2년간 주기적인 follow up통해 예후를 관찰중이며, 부정교합의 재발이나 보철물 파절은 현재까지 관찰되지 않았다.

국소적 치아이형성증의 임상적 방사선학적 연구 : 5년 추적관찰 (A Clinical and Radiological Study of Regional Odontodysplasia: Five-year Follow-up)

  • 송지현
    • 대한소아치과학회지
    • /
    • 제41권4호
    • /
    • pp.322-327
    • /
    • 2014
  • 국소적 치아이형성증(Regional Odontodysplasia)은 드물게 발생하는 발육성 장애로, 이환된 치아는 임상적, 방사선학적, 조직학적으로 특징적인 소견을 보인다. 국소적 치아이형성증은 유치열과 영구치열에 모두 영향을 미치며, 임상적으로 정상치아보다 크기가 작거나, 거칠고 불규칙한 치면을 가지는 등 형성부전, 석회화부전의 양상을 보인다. 방사선학적으로는 법랑질과 상아질이 얇고, 경계가 뚜렷하지 않아 방사선불투과성이 명확하지 않으며, "ghost-like appearance"와 같은 특징적인 소견을 보인다. 조직학적으로는 저석회화된 법랑질이 보이며, 법랑소주가 불규칙한 방향을 나타내고, 상아세관의 수가 감소되어 있다. 국소적 치아이형성증의 원인은 정확히 밝혀지지 않았으며, 상악 좌측에서 호발하고, 인종간의 유병률 차이는 존재하지 않으며, 남성에 비해 여성에서 더 호발하는 것으로 알려져 있다. 이 증례는 4세 6개월의 환아에서 임상적, 방사선학적 검사 결과 상악 우측 악궁에 발생한 국소적 치아이형성증으로 진단하고, 5년간의 주기적인 관찰을 시행하였다. 국소적 치아이형성증에 이환된 치아는 취약한 치면과 미성숙한 치근 때문에 예후가 불량할 수 있으므로 개개치아에 대한 주의깊은 임상적, 방사선학적 관찰을 통한 시기적절한 치료계획 수립이 중요할 것이다.

The Efficacy of the Graft Materials after Sinus Elevation: Retrospective Comparative Study Using Panoramic Radiography

  • Jeong, Tae Min;Lee, Jeong Keun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제36권4호
    • /
    • pp.146-153
    • /
    • 2014
  • Purpose: This study compares and evaluates the efficacy of graft materials after maxillary sinus bone grafts with autogenous tooth bone graft material (AutoBT), demineralized freeze-dried bone allograft (DFDBA) and deproteinized bovine bone mineral (DBBM). Methods: The study involved 30 sinuses in 26 patients who visited the Division of Oral and Maxillofacial Surgery, Department of Dentistry in Ajou University Hospital and received either AutoBT, DFDBA or DBBM with sinus elevation using the lateral window technique. Sinus graft height was measured before, immediately after, and six months after bone graft with panoramic radiography and the height changes of the sinus floor was compared according to the graft materials. Results: After six months, the decrease ratio of graft heights were 13.57% for AutoBT group, 14.30% for DFDBA group, and 11.92% for DBBM group. There was no statistically significant difference. Conclusion: The new maxillary sinus floor formed by the upper border of bone graft material, can repneumatize after the maxillary sinus elevation. Thus, long-term stability of sinus graft height represents an important factor for implant success. We found that the three graft materials for sinus elevation do not differ significantly and all three graft materials showed excellent resistance to maxillary sinus repneumatization. However, due to the special circumstances of the maxillary sinus and small sample, the actual difference between the three graft materials may not have been detectable. Therefore further study needs to be conducted for more reliable study results.

블루투스의 스캐터넷과 임베디드 시스템을 이용한 텔레메트리 시스템의 구현 (Implementation of Telemetry System using Scatternet in Bluetooth Technology)

  • 김종현;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 추계종합학술대회
    • /
    • pp.941-944
    • /
    • 2003
  • 본 논문에서는 각 가정이나 사무실에 설치된 전기, 수도, 가스 등 계량기의 사용량을 종합하여 검침원 호변방문 없이 외부에서 검침할 수 있도록 블루투스와 임베디드 시스템을 이용하여 원격 검침시스템을 구현하였다. 블루투스란 2.4GHz 대의 무선 주파수를 사용하는 근거리 무선 통신 기술로서 저전력 특성과 고속의 주파수 호핑 방식에 따른 높은 신뢰성 및 자체 에러 정정 기술을 지니고 있다. 이는 기존의 무선 모뎀보다 데이터 전송에 있어서 높은 신뢰성을 얻을 수 있게 해준다. 그리고 자체 네트워크망을 형성하므로 손쉽게 다른 기기와의 통신을 가능케 한다. 또한 무선 모뎀은 무선 단말기 소형화에 따른 제약을 받고 있으나 블루투스를 사용함으로써 저전력 특성과 더불어 휴대용으로의 기능에 부합시킬 수 있으며, 모듈의 원칩화가 진행됨에 따라 작은 크기로의 가능성이 제시된다. 또한 임베디드 시스템의 이동성을 이용하여 검침원이 외부에서 이동을 하면서 검침이 가능하며 시스템을 저전력의 ARM 프로세서를 이용함으로서 오랜 시간 장비의 효율적 사용이 가능 할 것이다.

  • PDF

보철물 조건에 따른 Periotest수치의 실험적 평가 (IN VITRO EVALUATION OF PERIOTEST VALUES UNDER VARIOUS CONDITIONS OF PROSTHESES)

  • 한중석
    • 대한치과보철학회지
    • /
    • 제35권4호
    • /
    • pp.793-800
    • /
    • 1997
  • Periotest(Siemens, Germany) has been used to test mobility of the implants clinically, however the effects of target materials and connection methods on the PTVs(Periotest Values) have not been evaluated. Periotest has been regarded as a reliable and objective tool to test implant and natural teeth mobility clinically, however this instrument showed different PTVs under various test conditions. This in vitro study was designed to compare PTVs of different veneering materials and prosthodontic designs (single and bridge restorations). To compare the effects of veneering materials on PTVs, 1 mm thickness of five different testing materials (porcelain, type III gold alloy, pure titanium, composite resin, acrylic resin) were placed on the resin block. Three full length of 13 mm Mark II implant fixtures were embedded into autopolymerizing resin block to fabricate single and bridge restorations. To evaluate effects of the connection method in single restorations, PTVs of screw retained(UCLA type) and cementation type(Cera-One system) were compared. Finally, to test reliability of PTVs of the final restorations, screw retained three unit short span PFM bridges were fabricated on the standard and Estheti-Cone abutments. All testing components were tightened with torque controller and PTVs of all specimens were measured 15 times for statistical analysis with SAS program. Following conclusions were made within the limit of this in vitro study. 1. PTVs of type III gold alloy, grade II titanium, composite resin veneering materials showed no significant differences, however acrylic resin and porcelain showed significant differences (P<0.05). 2. Single tooth restorations showed consistent PTVs as long as proper torque force was applied. 3. PTVs of bridge type prostheses was inconsistent regardless of abutment types. 4. PTVs of the prostheses showed higher scores and standard deviations than those of abutments regardless types of connection (P<0.05).

  • PDF

충격흡수용 고분자재료의 이용이 Implant 초기안정성과 동적거동에 미치는 영향 (The Effect of a Shock-Absorbable Polymer(Chitosan) on the Initial Stability and Dynamic Behavior of Dental Implant)

  • 주원;최귀원;권익찬;최재봉;문항진;신제원;이용찬
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.337-342
    • /
    • 1997
  • Dental implant has been increasingly used to recover the masticatory unction of tooth. It has been well known that the success of dental implant is heavily dependent on initial stability and long-term osseointegration due to optimal stress distribution in the surrounding bones. The role of periodontal ligament, removed during operation, is to absorb impact force and to distribute them to alveolar bone. or this reason, the study for artificial periodontal ligament has become an important issue in this field. In this study, chitosan was coated on dental implant or the purpose of replacing the role of intact periodontal ligament. The results by experiment and FEM analysis showed : I) Initial stability of dental implant was significantly increased(35%) when the implant was coated with chitosan. II) The coated implant showed higher impact absorption, more even stress distribution and lower stress magnitude under impact force than uncoated implant. Accordingly, the micro-fracture of the surrounding bones due to impact force would be lessened by chitosan coating on dental implant.

  • PDF

Secretion Effect of Estrogen of Different Growth Stages of Silkworm (Bombyx mori L.)

  • Ryu, Kang-Sun;Lee, Heui-Sam;Kim, Kee-Young;Kim, Mi-Ja;Oh, Hong-Guen;Kang, Pil-Don
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제22권1호
    • /
    • pp.17-20
    • /
    • 2011
  • The average life expectancy has continuously increased with the development of medical industry. As women get older, they experience the deficit of estrogen caused by decreased function of ovarian. Specifically, they suffer from temporary fever because of unstable vasomotion and, in the long term experience, degeneration of urogenital organs, tooth loss, arteriosclerosis, demantia, snores and so on. Because of these symptoms the estrogen medical supply is getting required. Along with this, many studies have conducted to find out substitutional medicals without any side effects. This research was carried out to find out such substitutable materials. For the purpose of study, we examined the change of estrogen using the rats fed with the pupa powder immediately before the eclosion, eclosed adult, the pupa extract immediately before the eclosion, and the silkworm powder prepared at $3^{rd}$ day of $5^{th}$ instar. The result showed no significant chance in weight, feeding and water intake quantity among variables. However, the estrogen hormone secretion effects was very high at 73 pg/ml in the rats fed with the freeze-dried powder of the Yeonnokjam male pupa prepared immediately before the eclosion, compared with the control at 59 pg/ml. The next was Yangwonjam male adult at 71 pg/ml.

백색광 주사간섭계의 생물학적 응용 (Biological Applications of White Light Scanning Interferometry)

  • 김기우
    • Applied Microscopy
    • /
    • 제41권4호
    • /
    • pp.223-228
    • /
    • 2011
  • 백색광 주사간섭계는 다양한 시료의 표면 특성을 분석하기 위하여 널리 활용되고 있다. 이 기법은 재료공학 분야에서 오래 전부터 이용되었으며 정성적인 형상 이미지 이외에도 정량적인 3차원 결과를 제공한다. 이 기법에서는 백색광을 광원으로 이용하는데, 기준면과 측정면에서의 반사광을 합쳐서 형성되는 간섭신호를 형태 정보로 활용한다. z축 결과인 고도는 회색수준으로 구분되어 제시된다. 이 기법을 통하여 대영역으로 생물 시료를 신속하고 비파괴적으로 형태를 계측할 수 있다. 연골세포, 치아 법랑질, 식물 잎을 대상으로 적용한 사례가 있다. 특히 표면 구조물의 폭, 길이, 경사각과 같은 특성도 이 기법을 통하여 정량화할 수 있다. 이 기법을 적용하기 위하여 일정 수준의 반사도가 필요한데, 식물 잎에서의 반사도는 그 요건을 충족하였다. 전도성 금속의 코팅 등 부가적인 시료 전처리가 필요 없으므로 이 기법을 통한 생물 시료의 정량적 측정이 더욱 증가할 것으로 예상한다.

Mental nerve paresthesia secondary to initiation of endodontic therapy: a case report

  • Andrabi, Syed Mukhtar-Un-Nisar;Alam, Sharique;Zia, Afaf;Khan, Masood Hasan;Kumar, Ashok
    • Restorative Dentistry and Endodontics
    • /
    • 제39권3호
    • /
    • pp.215-219
    • /
    • 2014
  • Whenever endodontic therapy is performed on mandibular posterior teeth, damage to the inferior alveolar nerve or any of its branches is possible. Acute periapical infection in mandibular posterior teeth may also sometimes disturb the normal functioning of the inferior alveolar nerve. The most common clinical manifestation of these insults is the paresthesia of the inferior alveolar nerve or mental nerve paresthesia. Paresthesia usually manifests as burning, prickling, tingling, numbness, itching or any deviation from normal sensation. Altered sensation and pain in the involved areas may interfere with speaking, eating, drinking, shaving, tooth brushing and other events of social interaction which will have a disturbing impact on the patient. Paresthesia can be short term, long term or even permanent. The duration of the paresthesia depends upon the extent of the nerve damage or persistence of the etiology. Permanent paresthesia is the result of nerve trunk laceration or actual total nerve damage. Paresthesia must be treated as soon as diagnosed to have better treatment outcomes. The present paper describes a case of mental nerve paresthesia arising after the start of the endodontic therapy in left mandibular first molar which was managed successfully by conservative treatment.