• 제목/요약/키워드: long implant

검색결과 517건 처리시간 0.025초

티타늄 합금, 지르코니아, 폴리에테르에테르케톤 지대주 재질에 따른 임플란트 구성요소의 응력분포: 유한 요소 분석을 통한 비교 연구 (Stress distribution in implant abutment components made of titanium alloy, zirconia, and polyetheretherketone: a comparative study using finite element analysis)

  • 김성민
    • 대한치과기공학회지
    • /
    • 제46권2호
    • /
    • pp.21-27
    • /
    • 2024
  • Purpose: This study aimed to analyze the stress distribution and deformation in implant abutments made from titanium (Ti-6Al-4V), zirconia, and polyetheretherketone (PEEK), including their screws and fixtures, under various loading conditions using finite element analysis (FEA). Methods: Three-dimensional models of the mandible with implant abutments were created using Siemens NX software (NX10.0.0.24, Siemens). FEA was conducted using Abaqus to simulate occlusal loads and assess stress distribution and deformation. Material properties such as Young's modulus and Poisson's ratio were assigned to each component based on literature and experimental data. Results: The FEA results revealed distinct stress distribution patterns among the materials. Titanium alloy abutments exhibited the highest stress resistance and the most uniform stress distribution, making them highly suitable for long-term stability. Zirconia abutments showed strong mechanical properties with higher stress concentration, indicating potential vulnerability to fracture despite their aesthetic advantages. PEEK abutments demonstrated the least stress resistance and higher deformation compared to other abutment materials, but offered superior shock absorption, though they posed a higher risk of mechanical failure under high load conditions. Conclusion: The study emphasizes the importance of selecting appropriate materials for dental implants. Titanium offers durability and uniform stress distribution, making it highly suitable for long-term stability. Zirconia provides aesthetic benefits but has a higher risk of fracture compared to titanium. PEEK excels in shock absorption but has a higher risk of mechanical failure compared to both titanium and zirconia. These insights can guide improved implant designs and material choices for various clinical needs.

Long-term outcomes after peri-implantitis treatment and their influencing factors: a retrospective study

  • Lee, Sung-Bae;Lee, Bo-Ah;Choi, Seong-Ho;Kim, Young-Taek
    • Journal of Periodontal and Implant Science
    • /
    • 제52권3호
    • /
    • pp.194-205
    • /
    • 2022
  • Purpose: This study aimed to determine the long-term outcomes after peri-implantitis treatment and the factors affecting these outcomes. Methods: This study included 92 implants in 45 patients who had been treated for peri-implantitis. Clinical data on the characteristics of patients and their implants were collected retrospectively. The change in the marginal bone level was calculated by comparing the baseline and the most recently obtained (≥3 years after treatment) radiographs. The primary outcome variable was progression of the disease after the treatment at the implant level, which was defined as further bone loss of >1.0 mm or implant removal. A 2-level binary logistic regression analysis was used to identify the effects of possible factors on the primary outcome. Results: The mean age of the patients was 58.7 years (range, 22-79 years). Progression of peri-implantitis was observed in 64.4% of patients and 63.0% of implants during an observation period of 6.4±2.7 years (mean±standard deviation). Multivariable regression analysis revealed that full compliance to recall visits (P=0.019), smoking (P=0.023), placement of 4 or more implants (P=0.022), and marginal bone loss ≥4 mm at baseline (P=0.027) significantly influenced the treatment outcome. Conclusions: The long-term results of peri-implantitis treatment can be improved by full compliance on the part of patients, whereas it is impaired by smoking, placement of multiple implants, and severe bone loss at baseline. Encouraging patients to stop smoking and to receive supportive care is recommended before treatment.

미니돼지에서 발치 후 즉시 임플란트 매식시 치경부 표면처리가 골재생에 미치는 효과 (THE EFFECT OF SURFACE TREATMENT OF THE CERVICAL AREA OF IMPLANT ON BONE REGENERATION IN MINI-PIG)

  • 조진용;김영준;유민기;국민석;오희균;박홍주
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권3호
    • /
    • pp.285-292
    • /
    • 2008
  • Purpose: The present study was performed to evaluate the effect of surface treatment of the cervical area of implant on bone regeneration in fresh extraction socket following implant installation. Materials and methods: The four minipigs, 18 months old and 30 kg weighted, were used. Four premolars of the left side of both the mandible and maxilla were extracted. ${\phi}$3.3 mm and 11.5 mm long US II plus implants (Osstem Implant co., Korea) with resorbable blasting media (RBM) treated surface and US II implants (Osstem Implant co., Korea) with machined surface at the top and RBM surface at lower portion were installed in the socket. Stability of the implant was measured with $Osstell^{TM}$ (Model 6 Resonance Frequency Analyser: Integration Diagnostics Ltd., Sweden). After 2 months of healing, the procedures and measurement of implant stability were repeated in the right side by same method of left side. At four months after first experiment, the animals were sacrificed after measurement of stability of all implants, and biopsies were obtained. Results: Well healed soft tissue and no mobility of the implants were observed in both groups. Histologically satisfactory osseointegration of implants was observed with RBM surface, and no foreign body reaction as well as inflammatory infiltration around implant were found. Furthermore, substantial bone formation and high degree of osseointegration were exhibited at the marginal defects around the cervical area of US II plus implants. However, healing of US II implants was characterized by the incomplete bone substitution and the presence of the connective tissue zone between the implant and newly formed bone. The distance between the implant platform (P) and the most coronal level of bone-to-implant contact (B) after 2 months of healing was $2.66{\pm}0.11$ mm at US II implants group and $1.80{\pm}0.13$mm at US II plus implant group. The P-B distance after 4 months of healing was $2.29{\pm}0.13$mm at US II implants group and $1.25{\pm}0.10$mm at US II plus implants group. The difference between both groups regarding the length of P-B distance was statistically significant(p<0.05). Concerning the resonance frequency analysis (RFA) value, the stability of US II plus implants group showed relatively higher RFA value than US II implants group. Conclusion: The current results suggest that implants with rough surface at the cervical area have an advantage in process of bone regeneration on defect around implant placed in a fresh extraction socket.

상악 전치부 단일 임플란트의 심미 보철 수복 증례 (Single implant restoration with esthetic prosthodontic treatment in maxillary anterior tooth: A case report)

  • 강현;서누리;박상원;임현필;윤귀덕;양홍서
    • 대한치과보철학회지
    • /
    • 제56권4호
    • /
    • pp.354-359
    • /
    • 2018
  • 상악 전치부의 단일 임플란트 수복 치료 시, 치은 퇴축 및 골결손 문제를 가질 경우 임플란트 보철의 심미적인 결과를 얻는 것은 쉽지 않다. 장기적으로 심미적 안정성이 유지되기 위해서는 임플란트를 이상적인 위치에 식립하는 것이 중요하며 연조직의 회복 및 보철물과의 조화가 중요하다. 이러한 심미성이 더욱 요구되는 임플란트 보철물의 제작 시 이상적인 임플란트의 위치 뿐만 아니라, 주변 연조직과의 조화 역시 중요하다. 본 증례에서는 상악 전치부에서 골결손과 치은 퇴축이 진행된 47세 남자환자에서 골유도재생술 및 치은재형성술을 통해 심미 임플란트 치료를 진행하였다.

개에서 즉시형과 지연형 인공치아 식립후 골유합에 대한 CT와 신티그라피 평가 (CT and scintigraphic evaluation of osseointegration following immediate versus delayed implantation in dogs)

  • 김중현;이재영;이원국;오원영;김소섭;강성수;최석화
    • 대한수의학회지
    • /
    • 제44권1호
    • /
    • pp.131-136
    • /
    • 2004
  • Osseointegration involves anchoring dental implants to stable bone rather than to soft-tissue. Clinical osseointegration is currently defined as the process whereby alloplastic material is asymptomatically and rigidly fixed and maintained in bone during functional loading. Full osseointegration is necessary for the success of long-term dental implants. Recent developments in computer assisted measurement of bone formation have improved maxillofacial examination and osseointegration. Computer assisted examination has also proved effective in dental implantology. This investigation was aimed to determine osseointegration in immediate and delayed implantation in the dog mandible using dental computed tomography (CT) and bone scintigraphy. Five adult (mean age of 2 years) mongrel dogs with a mean weight of 9.1 kg were used in this investigation. Titanium alloy implant systems with 4 mm in diameter and 10 mm in length were chosen for insertion. The second and third left mandibular premolars in each dog were extracted for the delayed implant insertion. Twelve weeks later, the second and third right mandibular premolars were extracted for the immediate implant insertion. Before the delayed and immediate implantation procedures and 0, 4, 8, and 12 weeks after the insertions, dental CT and scintigraphy were conducted. The CT and scintigraphic images indicate that reconstruction of bone surrounding of the immediate implant can be as successful as reconstruction of bone surrounding of the delayed implant.

녹내장 치료용 능동형 압력조절밸브(Implant) 모델링 및 설계 (Modeling and Design of an Active Pressure Regulating Valve(Implant))

  • 배병훈;김낙훈;이연;기홍석;김선호;박기환
    • 대한기계학회논문집A
    • /
    • 제25권5호
    • /
    • pp.805-815
    • /
    • 2001
  • Glaucoma is an eye disease which is caused by abnormal high IOP (Intra Ocular Pressure). High IOP is caused by the aqueous humor which is produced consistently but not drained due to malfunction of the trabecular system which has a role of draining the aqueous humor into the venous system. Currently, there are three methods to treat glaucoma-using medicines, surgical operation, and using implant device. The first and second methods are not long acting, so the use of implants is increasing in these days in order to drain out the aqueous humor compulsory. However, though conventional implants have a capability of pressure regulation, they cannot maintain IOPs desired for different patients, and too much aqueous humor are usually drained, to cause hypotony. To solve these problems, it is needed to develop a new implant which is capable of controling the IOP actively and copes with personal difference of patients. An active glaucoma implant consists of the valve actuator, pressure sensor, controller, and power supply. In this paper, firstly, we make an analysis of the operation of a conventional implant using a bond graph and show defects and limitations of the conventional valve analytically. Secondly, we design and analyze a valve actuator considering actuation principles, resistance elements, control methods, and energy sources focused on power saving problem. Finally, using simulations the possibility of the proposed valve actuator is investigated.

골유착성 보철물에 관한 삼차원 유한요소분석적 연구 (A STUDY ON THE OSSEOINTEGRATED PROSTESIS USING THREE DIMENSIONAL FINITE ELEMENT METHOD)

  • 김동원;김영수
    • 대한치과보철학회지
    • /
    • 제29권1호
    • /
    • pp.167-213
    • /
    • 1991
  • The successful replacement of missing teeth has been one driving aim behind the emergence of implant dentistry as both a technology and clinical vocation for over four decades. To date, a multitude of dental implant devices had been designed and utilized in the patient population. Most of these devices have been designed without support of the engineering criteria. The long-term success of any dental implant is dependent upon the optimization of stresses which occurs during oral function and parafunction. Although many studies have examined the biologic interactions between dental implants and living tissue, few studies have been reported on the biomechanical aspects of dental implants. The purpose of this study was to analyze the stress distribution of osseointegrated prosthesis on certain conditions, such as amount of load, location of load, length of fixtures, number of fixtures used, arch shape, bone quality, etc. Three dimentional finite element analysis was used for this study. FEM models were created using commercial software(Super SAP. for IBM 16 bit AT computer. All elements were 8-node brick, isoparametric. Mandible and prosthesis was modeled with 780 elements and 1074 nodes. The results were as follows : 1. In case of cantilever extension, there was a compressive stress at the base of the first implant and a tensile stress at the base of the second implant. 2. The stresses were linearly proportional to the amount of load. 3. The stresses were linearly proportional to the length of cantilever. 4. There was a stress concentration at the neck of the implant and bone under horizontal loads.

  • PDF

상이한 골질과 제원에 따른 짧은 임프란트의 응력 분포: 3차원 유한 요소 분석 (STRESS DISTRIBUTION PATTERN OF THE DIFFERENT DIAMETER AND LENGTH OF SHORT IMPLANTS ACCORDING TO THE BONE QUALITY : 3-D FINITE ELEMENTS ANALYSIS)

  • 김한구;김창현;표성운
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권2호
    • /
    • pp.116-126
    • /
    • 2009
  • The use of short implants has been accepted risky from biomechanical point of view. However, short implants appear to be a long term viable solution according to recent clinical reports. The purpose of this study was to investigate the effect of different diameter and length of implant size to the different type of bone on the load distribution pattern. Stress analysis was performed using 3-dimensional finite element analysis(3D-FEA). A three-dimensional linear elastic model was generated. All implants modeled were of the various diameter(${\phi}4.0$, 4.5, 5.0 and 6.0 mm) and varied in length, at 7.0, 8.5 and 10.0 mm. Each implant was modeled with a titanium abutment screw and abutment. The implants were seated in a supporting D2 and D4 bone structure consisting of cortical and cancellous bone. An amount of 100 N occlusal load of vertical and $30^{\circ}$ angle to axis of implant and to buccolingual plane were applied. As a result, the maximum equivalent stress of D2 and D4 bones has been concentrated upper region of cortical bone. As the width of implant is increased, the equivalent stress is decreased in cancellous bone and stress was more homogeneously distributed along the implants in all types of bone. The short implant of diameter 5.0mm, 6.0mm showed effective stress distribution in D2 and D4 bone. The oblique force of 100N generated more concentrated stress on the D2 cortical bone. Within the limitations of this study, the use of short implant may offer a predictable treatment method in the vertically restricted sites.

상악 무치악 환자에서 전방부 임플란트 지지 고정성 보철물을 이용한 임플란트 보조 국소의치 수복 증례 (Implant-assisted removable partial denture in a maxillary edentulous patient: A case report)

  • 강현모;김지환;김재영
    • 대한치과보철학회지
    • /
    • 제60권4호
    • /
    • pp.442-452
    • /
    • 2022
  • 무치악 환자의 구강 재건을 위한 임플란트를 활용한 치료 계획으로는 임플란트 지지 고정성 가공 의치, 임플란트 피개 의치, 임플란트 보조 국소의치 등이 있으며, 각각의 방식에 대한 적응증과 장단점이 다양하다. 본 증례의 환자는 상악 국소의치의 모든 잔존 지대치의 발거가 필요했으며 후방부 잔존골이 부족하여 식립 가능한 임플란트의 개수가 한정적이었다. 따라서 골 지지가 양호한 전방부에 4개의 임플란트 식립하여 임플란트 지지 서베이드 크라운과 후방연장 임플란트 보조 국소의치로 수복해주었고 환자에게 경제적으로 효과적이면서도 심미적, 기능적으로 만족스러운 결과를 제공하였다. 상악 무치악 환자에게 이와 같은 치료 계획은 경우에 따라 임플란트 피개의치의 대안으로 사용될 수 있으며 임상적, 생역학적 유효성을 검증하기 위해 더 많은 연구가 필요하다.

마이크로패터닝을 부여한 임플란트 주변골에서의 하중 분포에 관한 유한요소분석법적 연구 (Finite Element Analysis of Stress Distribution around the Micro-Patterned Implants)

  • 허배녕;김대곤;박찬진;조리라
    • 구강회복응용과학지
    • /
    • 제24권1호
    • /
    • pp.67-76
    • /
    • 2008
  • 골조직이 자라 들어갈 수 있는 적절한 크기의 마이크로패터닝을 부여하면 강하고 지속적인 골유착을 이룰 수 있는 생역학적 결합을 이룰 수 있다. 또한 마이크로패터닝을 통해 골조직과 접촉하는 면적을 증가시킴으로써 하중을 적절히 분산시킬 수도 있다. 본 연구에서는 마이크로패터닝의 형태와 크기에 따른 응력의 분산에 대해 연구하였다. 나사 하나에서의 하중을 연구하기 위해 2차원 유한요소분석법을 이용하였다. 임플란트는 무한히 긴 피질골에 100% 접촉하며 골-임플란트 계면은 고정된 것으로 경계조건을 설정한 후 마이크로패터닝의 위치와 수에 따라 5군으로 나누어 축력을 가한 후 최대응력과 응력의 분산양상을 비교하였다. 연구 결과, 마이크로패터닝을 부여하면 일반적인 나사에 비해 응력을 보다 넓게 분산시켰으며 나사의 하방에 마이크로패터닝을 부여한 것이 상방에 부여한 것보다 더 고르게 응력을 분산시켰다. 3개의 마이크로패터닝을 부여한 군이 2개의 마이크로패터닝을 부여한 군에 비해 응력을 넓게 분산시켰으나 응력이 집중되는 부위가 나타났다. 이상의 결과를 통해 마이크로패터닝을 부여하면 응력의 분산효과가 있으며 특히 나사 하방에 부여하는 것이 더 큰 효과를 냄을 알 수 있었다.