• 제목/요약/키워드: long bone fracture

검색결과 162건 처리시간 0.027초

외상성 흉골 골절에 대한 임상적 고찰 (A Clinical Evaluation of the Traumatic Sternal Fracture)

  • 김재련;임진수;최형호
    • Journal of Chest Surgery
    • /
    • 제28권6호
    • /
    • pp.601-605
    • /
    • 1995
  • Clinical evaluations were performed on 54 cases of the traumatic sternal fracture, those were admitted and treated at the department of Thoracic and Cardiovascular Surgery in Chosun University Hospital during the past 5 years period from January 1990 to December 1994. The frequency was about 7.8% of the nonpenetrating chest trauma. The ratio of male to female was 2 : 1 in male predominance. Average age was 45.7 years old and age distribution was from 18 to 80 years old. The most common cause in the sternal fracture were high decelerating injury[ 38 cases . The most common fracture site was sternal body. Associated intrathoracic organ injuries were cardiac contusion[11cases , hemopneumothorax and pulmonary contusion. Added, thoracic cage and extrathoracic organ injuries were rib fracture, head injuries, thoracic spinal fracture and long bone fracture. Abnormal ECG findings were sinus bradycardia[4 cases , sinus tachycardia[3 cases , bundle branch block, atrial fibrillaton, left ventricular hypertrophy and myocardial ischemia. The average days of admission was 19.1 days. All patients were treated with conservative treatment. The complications after treatment were atelectasis[2 cases ,empyema[1 cases , ARDS[1 cases .

  • PDF

체외 고정구용 골 삽입 금속 나사 개발 (The Development of Pin Screws into the Bone for External Fixator)

  • 최영철;이근민;나운환;송병섭
    • 재활복지공학회논문지
    • /
    • 제2권1호
    • /
    • pp.5-17
    • /
    • 2009
  • 골에 삽입한 후 체외고정구에 결합하여 조절함으로써 골절회복(장골의 개방성골절, 연부조직의 재건술 및 관절고정술 등)에 사용되는 금속나사를 특별히 고안한 절삭도구와 연삭기구 및 독자적인 후처리 공정을 통하여 국내기술로 처음 개발, 상품화하였다. 개발된 제품과 수입제품의 비교실험을 실시한 결과, 수입제품대비 평균 103%의 특성을 나타내었다. 이 제품의 개발에 적용된 설계기법 및 후처리 공정과 요소실험 결과들을 소개한다.

  • PDF

안면부 골절에 사용된 흡수성 보형물의 지연성 이물반응: 증례보고 (Delayed Foreign Body Reaction around the Absorbable Implants in Facial Bone Fracture: A Case Report)

  • 서용훈;김영준
    • Archives of Plastic Surgery
    • /
    • 제38권6호
    • /
    • pp.875-878
    • /
    • 2011
  • Purpose: Absorbable implants are frequently used to fix facial bone fractures, because they are radiolucent and compatible with magnetic resonance imaging (MRI). Despite their increasing usage, however, there have been few reports about their long-term side-effects. In this paper, a case in which absorbable implants led to a foreign body reaction 17 months after their insertion is presented. Methods: A previously healthy 19-year-old male fell from a flight of stairs and visited the authors' hospital with right periorbital pain. Zygomaticomaxillary fracture involving right orbital floor was detected via a facial bone computed tomography (CT). Internal fixation with absorbable implants was followed by open reduction. 17 months after the surgery, the patient complained of localized periorbital swelling. Removal of the granulomatous lesion including the absorbable implants along with their biopsy and culture was performed. Results: The granulomatous lesion around the implants was firm and extended into the maxillary sinus. The histologic finding showed a microabscess with a foreign body reaction. Methicillin-sensitive Staphylococcus aureus growth was confirmed in the culture. No definite abnormal symptoms ensued after the complete removal. Conclusion: A microabscess-forming granulomatous lesion around the absorbable implant can cause delayed symptomatic foreign body reaction despite its rare occurrence. Complete removal of the lesion including implants is expected to have a successful outcome if it is encountered.

10년 이상 장기 추적된 두개골 외판을 이용한 비첨성형술 환자의 골이식편의 운명 (The Fate of Calvarial Bone Graft in Nasal Tip Plasty Patients Followed Up for Over 10 Years)

  • 김덕중;이수향;황은아;최현곤;김순흠;신동혁;엄기일
    • Archives of Plastic Surgery
    • /
    • 제37권5호
    • /
    • pp.671-675
    • /
    • 2010
  • Purpose: In order to maintain corrected nasal tip projection, strong support is important. Authors used calvarial bone graft method for this purpose. Patients were followed up about permanency of the bone graft for a long time. Methods: From 1995 to 1998, author performed calvarial bone graft on 30 adult patients with secondary cleft lip and nose deformity. Patients were observed for 34 months. There were no specific complications, and results were satisfactory. We could confirm the permanence of the calvarial bone graft in 3 patients by photography and radiologic studies for 10 years follow-up. Results: None of the patients showed size change or displacement. But the portion of graft facing the tip was absorbed resulting in loss of tip projection and short nose in two patients. One patient had fracture on the middle of the graft. This caused depression from lower portion of the dorsum to the tip. Conclusion: Despite of autogenous grafts such as calvarial bone, absorption of the bone may occur when compressed with tension for a long period. And the graft in the nasal tip not having any contact with the nasal bone may cause absorption of the graft.

경골 손상 치료에서의 침습형 저출력 레이저 치료법 및 효과 (A Method and Effect for Tibial Defect Treatment Using Interstitial Low Level Laser)

  • 이상엽;황동현;김한성;정병조
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권4호
    • /
    • pp.147-151
    • /
    • 2016
  • Tibial defect, or fracture is very routine musculoskeletal case which brings fully uncomfortable and painful situations to patient. Moreover, it has long hospitalization period because of its risk of non-union. There are many studies using ultrasound, vibration, and laser for bone regeneration to figure out fast bone healing. Among them, Low Level Laser Therapy (LLLT) is already known that it is very easy to treat and may have positive effect for bone regeneration. However, LLLT has uncertain energy dose because of scattering and absorption of laser in tissue. In this study, we used interstitial LLLT to treat tibial defect in animal study. The Interstitial LLLT can overcome some limitations caused by laser scattering or absorption in tissue medium. The results were evaluated using u-CT which can calculate X-ray attenuation coefficient and bone volume of bone defect area. These results showed that interstitial LLLT may affect fast bone healing process in early phase.

오픈소스 기반 수술항법장치의 하지 골절수술 응용검토 (Open Source-Based Surgical Navigation for Fracture Reduction of Lower Limb)

  • 정상현;박재영;박철우;오창욱;박일형
    • 대한기계학회논문집A
    • /
    • 제38권5호
    • /
    • pp.497-503
    • /
    • 2014
  • 골절 치료에서 최소 침습 수술 방법은 그 효용성이 입증 되었지만, 의료진이 골편을 직접 볼 수 없기 때문에 방사선 투시영상장치(C-armed fluoroscopy)에 의존하여 수술을 진행하게 된다. 최소침습 수술은 환자에게는 감염이 적고 회복이 빠르다는 장점이 있지만 의료진에게는 과도한 방사선 피폭과 부정확한 골절정복 가능성이 높아지는 문제점이 발생할 수 있다. 본 연구에서는 이와 같은 문제를 해결하기 위해 수술 항법장치와 수술 지원로봇을 활용하는 방법을 제안한다. 골편의 3D CT 모델을 실제 골편과 특징점을 이용해서 정합하는 오픈 소스 기반으로 구성된 수술 항법 장치와 2D 투시 영상에서 골편간의 회전 변위를 정상측 투시 영상과 비교하여 확인 할 수 있는 방법을 제안하였고, 모델 뼈를 이용한 실험으로 제안한 방법의 임상적 타당성을 확인하였다. 그 결과 3D CT-기반 수술 항법 장치의 모델 뼈와 영상정합 정확도는 약 2mm 로 정형외과 수술에서 요구되는 사양을 만족했으며, 2D 투시 영상에서는 ${\pm}15^{\circ}$범위의 골편간의 회전에서 $2.5^{\circ}$이하의 변별력을 나타내었다.

컴퓨터 시뮬레이션 기반 골절고정 및 기형교정수술 예비계획 (Computer Simulation based Pre-operative Planning of Fracture Fixation and Deformity Correction)

  • 김윤혁;권영하;허유
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.698-700
    • /
    • 2003
  • This paper presents a model and analysis techniques for a unilateral external fixator to achieve fracture reduction and deformity correction in long bones precisely. through fixator joint adjustment. Combining the kinematic analysis with a graphic model of the tibia and the fixator allowed 3D simulation and visualization of the adjustments required to reduce fracture or correct bone deformity after osteotomy. The model and analysis technique can be used for fixator evaluation and clinical application planning.

  • PDF

A 30-year neglected foreign body mimicking a maxillary fracture

  • Lee, Wang Seok;Park, Eun Soo;Kang, Sang Gue;Tak, Min Sung;Kim, Chul Han
    • 대한두개안면성형외과학회지
    • /
    • 제20권3호
    • /
    • pp.195-198
    • /
    • 2019
  • A-50-year-old male patient presented with complaint of tenderness on the left malar area after traffic accident. Our first impression on him was zygomatic fracture, we did radiologic work-up and physical examination on him. But, on the computed tomography scan, there was no fracture or discontinuity on his facial bone. The computed tomography scan was revealed a 4-cm long foreign body in left maxillary sinus with a large amount of fluid collection. After thorough history taking from him, we reveal the patient had a history of trauma 30 years back on the left zygomatic area with a chopstick. The foreign body was removed via transoral approach with the endoscopic assist. There was no complication after operation.

Delayed union of a pediatric lunate fracture in the United Kingdom: a case report and a review of current concepts of non-scaphoid pediatric carpal fractures

  • Timothy P. Davis;Elizabeth Headon;Rebecca Morgan;Ashley I. Simpson
    • Journal of Trauma and Injury
    • /
    • 제36권4호
    • /
    • pp.315-321
    • /
    • 2023
  • Pediatric carpal fractures are rare and often difficult to detect. This paper reviews the current literature on pediatric non-scaphoid carpal fractures, with a case report of a lunate fracture associated with a distal radius and ulnar styloid fracture, managed nonoperatively in a 12-year-old boy. There is lack of consensus regarding the management of these fractures due to the low number of reported cases. A frequent lack of long-term follow-up limits our understanding of the outcomes, but good outcomes have been reported for both nonoperative and operative management. This case report brings attention to the current time period for the definition of delayed union in pediatric carpal fractures, and emphasizes the need for prolonged follow-up for the detection of delayed complications leading to functional impairment.

흡수성 스크류를 이용한 하악과두 골절의 치료 (TREATMENT OF CONDYLE FRACTURE WITH RESORBABLE SCREW)

  • 여인범;민승기;오승환;권경환;최상문;박상규
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제28권6호
    • /
    • pp.559-564
    • /
    • 2006
  • According to the development of operation technique and biologic materials, oromaxillofacial surgery department have used many kinds of metal and biologic materials in ORIF and plastic surgery. In maxillofacial fracture, ORIF with metal plate and screw have short healing period and good prognosis. But ORIF with metal materials have many complications as maxillofacial abnormal growth, screw loosening, bone malunion. And metal materials have not used in infection site. The purpose of this study is to evaluate the clinical value of 10 condylar fracture patients operated with absorbable screw at Wonkwang university. Ten patients(8 males, 2 female, mean aged 28) who had mandibular condyle process fracture treated with PLLA implants(poly-l-lactide) was recalled for follow-up clinical and radiologic examination for 10 years. Mouth opening recorvered to more than 35mm and occlusion was stable in all patients. All fractured mandibular condyles showed anatomic good reduction and long-term stability with the use of resorbable miniplates and screw. Bone healing was satisfactory in all patients, and there was no evidence of abnormal resorption of condylar process.