• Title/Summary/Keyword: long arm

Search Result 313, Processing Time 0.033 seconds

Demographic and Clinical Characteristics of Primary Frozen Shoulder in a Korean Population: A Retrospective Analysis of 1,373 Cases

  • Cho, Chul-Hyun;Koo, Tae Won;Cho, Nam-Su;Park, Kyoung-Jin;Lee, Bong Gun;Shin, Dongju;Choi, Sungwook;Cho, Seung-Hyun;Kim, Myung-Sun;Ko, Sang-Hun;Kim, Chul-Hong;Park, Jin-Young;Yoo, Yon-Sik
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.3
    • /
    • pp.133-137
    • /
    • 2015
  • Background: The aim of this study was to investigate the demographic and clinical characteristics of patients with primary frozen shoulder in a Korean population. Methods: A total of 1,373 patients whose shoulders were diagnosed with primary frozen shoulder across 11 resident-training hospitals were reviewed retrospectively. Various demographic characteristics and clinical characteristics according to gender and presence of diabetes were evaluated. Results: The average age of patients was 55.4 years. Gender proportion was 58.3% females and 41.7% males. The frozen shoulder involved the non-dominant arm in 60.7% of patients and the bilateral arms in 17.6% of patients. The average duration of symptoms was 8.9 months, and 51.3% of patients had experienced nocturnal pain. Comorbidities associated with frozen shoulder in our sample of patients included diabetes (18.7%), cardiovascular diseases (17.7%), thyroid diseases (5.4%), and cerebrovascular diseases (3.6%). The diabetic group was correlated with the following demographic and clinical characteristics: old age, involvement of the dominant arm, nocturnal pain, long duration of symptoms, and no history of trauma. Further, we found that, in males, having a frozen shoulder was significantly correlated with a history of trauma; in females, having a frozen shoulder was significantly correlated with having thyroid diseases. Conclusions: These demographic data of primary frozen shoulder in the Korean population were consistent with those of previously reported epidemiologic studies. Primary frozen shoulder with diabetes was correlated with old age, bilateral involvement, long duration of symptoms, and nocturnal pain.

Molecular Genetic Analysis of Microdeletions in Y Chromosome from Korean Male Infertility Patients (한국인 남성 불임환자에서 Y염색체내 미세결실의 분자유전학적 분석)

  • Yoon, Hyun-Soo;Lee, Jeong-Hen;Seo, Ju-Tae;Kim, Hae-Jung;Lee, Dong-Ryul;Jeon, Jong-Sik;Cho, Jung-Hyun;Kim, Moon-Kyoo;Lee, Moo-Sang;Roh, Sung-Il
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.23 no.3
    • /
    • pp.367-377
    • /
    • 1996
  • Genes on the long arm of Y chromosome, particularly interval 6, are believed to playa critical role in human spermatogenesis. The objective of this study was to validate a sequenced-tagged site(STS)-mapping strategy for the detection of Yq microdeletion and to use this method to determine the proportion of men with Yq microdeletions in idiopathic, obstructive, nonobstructive azoospermia, severe OATS and in normal males. We analyzed three STS markers mapped to interval 6 within long arm of the Y chromosome from 106 nonobstructive, 30 obstructive azoospermia, 15 severe OATS patients, and normal 42 males in Korean men. By PCR, we tested leukocyte DNA, for the presences of STS markers(DAZ, sY129 and sY134) and SRY gene as internal control. And PCR results were confirmed by Southern hybridization, and were investigated by SSCP analysis for DAZ gene mutation. None of 42 normal males and 30 obstructive azoospermia had microdeletions, Of the 15 severe OATS typed with DAZ, sY129 and sY134, 3(20.0%) patients failed to amplify 1 or more STS markers, and of the 106 nonobstructive azoospermia typed with DAZ, sY129 and sY134, 12(11.3%) patients failed to amplify 1 or more STS markers. From these results, high prevalence(12.4%) of Yq deletion(DAZ, sY129, sY134) in men with nonobstructive idopathic azoospermia and severe OATS were observed in Korean infertility patients. To avoid the infertile offspring by assisted reproductive technique using ICSI or ROSI, genetic diagnosis will be needed in IVF-ET program.

  • PDF

The Evaluation of Attenuation Difference and SUV According to Arm Position in Whole Body PET/CT (전신 PET/CT 검사에서 팔의 위치에 따른 감약 정도와 SUV 변화 평가)

  • Kwak, In-Suk;Lee, Hyuk;Choi, Sung-Wook;Suk, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.21-25
    • /
    • 2010
  • Purpose: For better PET imaging with accuracy the transmission scanning is inevitably required for attenuation correction. The attenuation is affected by condition of acquisition and patient position, consequently quantitative accuracy may be decreased in emission scan imaging. In this paper, the present study aims at providing the measurement for attenuation varying with the positions of the patient's arm in whole body PET/CT, further performing the comparative analysis over its SUV changes. Materials and Methods: NEMA 1994 PET phantom was filled with $^{18}F$-FDG and the concentration ratio of insert cylinder and background water fit to 4:1. Phantom images were acquired through emission scanning for 4min after conducting transmission scanning by using CT. In an attempt to acquire image at the state that the arm of the patient was positioned at the lower of ahead, image was acquired in away that two pieces of Teflon inserts were used additionally by fixing phantoms at both sides of phantom. The acquired imaged at a were reconstructed by applying the iterative reconstruction method (iteration: 2, subset: 28) as well as attenuation correction using the CT, and then VOI was drawn on each image plane so as to measure CT number and SUV and comparatively analyze axial uniformity (A.U=Standard deviation/Average SUV) of PET images. Results: It was found from the above phantom test that, when comparing two cases of whether Teflon insert was fixed or removed, the CT number of cylinder increased from -5.76 HU to 0 HU, while SUV decreased from 24.64 to 24.29 and A.U from 0.064 to 0.052. And the CT number of background water was identified to increase from -6.14 HU to -0.43 HU, whereas SUV decreased from 6.3 to 5.6 and A.U also decreased from 0.12 to 0.10. In addition, as for the patient image, CT number was verified to increase from 53.09 HU to 58.31 HU and SUV decreased from 24.96 to 21.81 when the patient's arm was positioned over the head rather than when it was lowered. Conclusion: When arms up protocol was applied, the SUV of phantom and patient image was decreased by 1.4% and 9.2% respectively. With the present study it was concluded that in case of PET/CT scanning against the whole body of a patient the position of patient's arm was not so much significant. Especially, the scanning under the condition that the arm is raised over to the head gives rise to more probability that the patient is likely to move due to long scanning time that causes the increase of uptake of $^{18}F$-FDG of brown fat at the shoulder part together with increased pain imposing to the shoulder and discomfort to a patient. As regarding consideration all of such factors, it could be rationally drawn that PET/CT scanning could be made with the arm of the subject lowered.

  • PDF

Development of Supplemental Equipment to Reduce Movement During Fusion Image Acquisition (융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발)

  • Cho, Yong Gwi;Pyo, Sung Jae;Kim, Bong Su;Shin, Chae Ho;Cho, Jin Woo;Kim, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.84-89
    • /
    • 2013
  • Purpose: Patients' movement during long image acquisition time for the fusion image of PET-CT (Positron Emission Tomography-Computed Tomography) results in unconformity, and greatly affects the quality of the image and diagnosis. The arm support fixtures provided by medical device companies are not manufactured considering the convenience and safety of the patients; the arm and head movements (horizontal and vertical) during PET/CT scan cause defects in the brain fundus images and often require retaking. Therefore, this study aims to develop patient-compensation device that would minimize the head and arm movements during PET/CT scan, providing comfort and safety, and to reduce retaking. Materials and Methods: From June to July 2012, 20 patients who had no movement-related problems and another 20 patients who had difficulties in raising arms due to shoulder pain were recruited among the ones who visited nuclear medicine department for PET Torso scan. By using Patient Holding System (PHS), different range of motion (ROM) in the arm ($25^{\circ}$, $27^{\circ}$, $29^{\circ}$, $31^{\circ}$, $33^{\circ}$, $35^{\circ}$) was applied to find the most comfortable angle and posture. The manufacturing company was investigated for the permeability of the support material, and the comfort level of applying bands (velcro type) to fix the patient's head and arms was evaluated. To find out the retake frequency due to movements, the amount of retake cases pre/post patient-compensation were analyzed using the PET Torso scan data collected between January to December 2012. Results: Among the patients without movement disorder, 18 answered that PHS and $29^{\circ}$ arm ROM were the most comfortable, and 2 answered $27^{\circ}$ and $31^{\circ}$, respectively. Among the patients with shoulder pain, 15 picked $31^{\circ}$ as the most comfortable angle, 2 picked $33^{\circ}$, and 3 picked $35^{\circ}$. For this study, the handle was manufactured to be adjustable for vertical movements. The material permeability of the patient-compensation device has been verified, and PHS and the compensation device were band-fixed (velcro type) to prevent device movements. A furrow was cut for head fixation to minimize the head and neck movements, fixing bands were attached for the head, wrist, forearm, and upper arm to limit movements. The retake frequency of PET Torso scan due to patient movements was 11.06% (191 cases/1,808 patients) before using the movement control device, and 2.65% (48 cases/1,732 patients) after using the device; 8.41% of the frequency was reduced. Conclusion: Recent change and innovation in the medical environment are making expensive medical image scans, and providing differentiated services for the customers is essential. To secure patient comfort and safety during PET/CT scans, ergonomic patient-compensation devices need to be provided. Therefore, this study manufactured a patientcompensation device with vertically adjustable ergonomic ROM according to the patient's body shape and condition during PET Torso scan. The defects in the basal ganglia images due to arm movements were reduced, and retaking was decreased.

  • PDF

A Study on Chamber Design for the Efficient Preservation of a Small Amount of Archives (소량 기록물의 효율적 보존을 위한 보존챔버 설계에 관한 연구)

  • Bong, Choon-Keun;Park, Seong-Jin;Lee, Jeong-Joo;Shin, Hyun-Chang
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.13 no.1
    • /
    • pp.35-58
    • /
    • 2013
  • The archives preservation chamber is an equipment that is able to store important archives with air-cleaning and isothermal-isohumidity control functions to permanently store archives in a highly safe environment. The chamber can only store small amounts of archives but it is crucial for organizations preserving archives to economically store a variety of archives, be it a medium or a small amount of documents. An arm of this study researches the current preservation status of the local record center to determine the need for such a chamber. In addition, in order to improve the air-cleaning and isothermal-isohumidity functions, the researchers of this study have conducted analyses to design the core parts. The preservation chamber that had been designed includes an archives preservation area, air-cleaning equipment, and environment measurement equipment. A preservation chamber is used to preserve small amounts of important archives safely. Thus, when a local record center is preserving various types of archives in small or medium quantities in a stack room, the preservation chamber can be used to aid their long-term preservation.

Description of Nearly Completed Mitochondrial Genome Sequences of the Garden Chafer Polyphylla laticollis manchurica, Endangered in Korea (Insecta: Coleoptera)

  • Kim, Min Jee;Kim, Ki-Gyoung;Kim, Iksoo
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.27 no.1
    • /
    • pp.185-202
    • /
    • 2013
  • In this study, we present the nearly complete mitogenome sequences of the garden chafer, Polyphylla laticollis manchurica, which is listed as an endangered species in Korea. The P. l. manchurica mitogenome, which includes unfinished whole A+T-rich region and a partial srRNA was 14,473-bp long, possessing typical sets of genes (13 PCGs, 22 tRNA genes, and 2 rRNA genes). Gene arrangement of the P. l. manchurica mitogenome was identical to the common one found in the majority of insects. The 5 bp-long motif sequence (TAGTA) that has been suggested to be the possible binding site for the transcription termination peptide for the major-strand was also found in the P. l. manchurica mitogenome between $tRNA^{Ser}$(UCN) and ND1. The start codon for COI gene and ATPase8 was designated as a typical TTG. All tRNAs of the P. l. manchurica showed a stable canonical clover-leaf structure of other mt tRNAs, except for $tRNA^{Ser}$(AGN), DHU arm of which could not form stable stemloop structure. As has been previously determined, the high A/T content was unanimously observed in P. l. manchurica in terms of A/T bias in the third codon position (73.5%) compared with the first (66.4%) and second codon position (66.2%). The PCGs encoded in major-strands are slightly T-skewed, whereas those of the minor-strand are A-skewed, indicating strand asymmetry in nucleotide composition in the Coleoptera including P. l. manchurica.

Free Hand Insertion Technique of S2 Sacral Alar-Iliac Screws for Spino-Pelvic Fixation : Technical Note, Acadaveric Study

  • Park, Jong-Hwa;Hyun, Seung-Jae;Kim, Ki-Jeong;Jahng, Tae-Ahn
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.6
    • /
    • pp.578-581
    • /
    • 2015
  • A rigid spino-pelvic fixation to anchor long constructs is crucial to maintain the stability of long fusion in spinal deformity surgery. Besides obtaining immediate stability and proper biomechanical strength of constructs, the S2 alar-iliac (S2AI) screws have some more advantages. Four Korean fresh-frozen human cadavers were procured. Free hand S2AI screw placement is performed using anatomic landmarks. The starting point of the S2AI screw is located at the midpoint between the S1 and S2 foramen and 2 mm medial to the lateral sacral crest. Gearshift was advanced from the desired starting point toward the sacro-iliac joint directing approximately $20^{\circ}$ angulation caudally in sagittal plane and $30^{\circ}$ angulation horizontally in the coronal plane connecting the posterior superior iliac spine (PSIS). We made a S2AI screw trajectory through the cancellous channel using the gearshift. We measured caudal angle in the sagittal plane and horizontal angle in the coronal plane. A total of eight S2AI screws were inserted in four cadavers. All screws inserted into the iliac crest were evaluated by C-arm and naked eye examination by two spine surgeons. Among 8 S2AI screws, all screws were accurately placed (100%). The average caudal angle in the sagittal plane was $17.3{\pm}5.4^{\circ}$. The average horizontal angle in the coronal plane connecting the PSIS was $32.0{\pm}1.8^{\circ}$. The placement of S2AI screws using the free hand technique without any radiographic guidance appears to an acceptable method of insertion without more radiation or time consuming.

Review of Prevention of Hemipelegic Shoulder Subluxation After Stroke (뇌졸중 편마비환자의 견관절 아탈구 예방에 관한 고찰)

  • Han, Jin-Tae;Kweon, Oh-Hyun;Shin, Hyung-Soo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.2 no.2
    • /
    • pp.243-250
    • /
    • 2007
  • Purpose : Shoulder subluxation is a very common problem in patients with hemiplegia with stroke. Prevention of the low tone subluxed shoulder has been an issue for physical therapists working with neurological patients for many years. Methods : This study reviewed the literature to definite the management and a cause of shoulder subluxation with hemiplegia patients after stroke. Various modalities have been suggested for realigning the glenohumeral joint, but their use is controversial. The purpose of this paper is to review critically the evidence base in order to inform the clinical decision-making process for physiotherapists working in neurology. Results : Literature has identified supports, strapping and functional electrical stimulation(FES) in the management of low tone shoulders. Following review of this evidence it is suggested that there is a lack of reliable and valid research evidence on which to base conclusions. The modalities with the best supporting evidence for realigning the low tone subluxed glenohumeral joint are the triangular sling, Harris hemi sling and the Rolyan humeral cuff used in a standing position and the lap board and arm trough while the patient is sitting. However, due to soft tissue adaptation with associated lack of movement, over-correction and the need for careful patient positioning these supports need to be evaluated for each patient and should be used only in appropriate situations. Conclusion : Similarly, there is a lack of evidence on the effects of long-term use to this equipment. Electrical stimulation is also thought to have potential in the treatment to subluxed low tone shoulders but additional research is required to clarify the parameters for use and the long-term effects of these forms of management.

  • PDF

A Study on the Somatotype Classification for Middle-School Girls' Uniform (여중생 교복 설계를 위한 체형 유형화에 대한 연구)

  • Kim, Ju-Yeon;Lee, Hyo-Jin
    • The Research Journal of the Costume Culture
    • /
    • v.17 no.4
    • /
    • pp.663-678
    • /
    • 2009
  • The growth of the middle school girls show big difference among the individuals and the development of each area of the body is not uniformed but diverse which could be understood as the period that the problems on the fit of the clothes occur extensively. Therefore, in this study, the somatotype of the middle school girls are intended to be categorized for the highly applicable clothes design. For this, the 3 middle schools in Jeonju were selected for anthropometric measurement of 324 middle schools. The items of measurement are related to the somatotype of middle school girls, clothes design which is consisted of total of 50 items. For the basic data of clothes was judged that the classification of somatotype related to the tops and bottoms would be rational; hence, it is classified into the upper part and lower part of the body to extract the body shape consistent factor. As a result of analyzing the factors, the upper body consistent was extracted as the 4 items: upper body circumference, upper body length, breast growth and arm length. It was displayed as 75.26% explicability. The lower body consistent factors are extracted as lower body height, lower body circumference, hip length, and rear shape with 78.62% explicability. To classify the somatotype of upper body and lower body, each factor score is made into the independent viable for group analysis. As a result, the upper body was classified into the 'upper body with small breast and long' and 'upper body with big breast'. The lower body was categorized as 'lower body with long hip length' and 'standard lower body'.

  • PDF

Long-term consistency of clinical sensory testing measures for pain assessment

  • Pablo Bellosta-Lopez;Victor Domenech-Garcia;Thorvaldur Skuli Palsson;Pablo Herrero;Steffan Wittrup Mcphee Christensen
    • The Korean Journal of Pain
    • /
    • v.36 no.2
    • /
    • pp.173-183
    • /
    • 2023
  • Background: Understanding the stability of quantitative sensory tests (QSTs) over time is important to aid clinicians in selecting a battery of tests for assessing and monitoring patients. This study evaluated the short- and long-term reliability of selected QSTs. Methods: Twenty healthy women participated in three experimental sessions: Baseline, 2 weeks, and 6 months. Measurements included pressure pain thresholds (PPT) in the neck, upper back, and leg; Pressure-cuff pain tolerance around the upper-arm; conditioned pain modulation during a pressure-cuff stimulus; and referred pain following a suprathreshold pressure stimulation. Intraclass correlation coefficients (ICC) and minimum detectable change (MDC) were calculated. Results: Reliability for PPT was excellent for all sites at 2 weeks (ICC, 0.96-0.99; MDC, 22-55 kPa) and from good to excellent at 6 months (ICC, 0.88-0.95; MDC, 47-91 kPa). ICC for pressure-cuff pain tolerance indicated excellent reliability at both times (0.91-0.97). For conditioned pain modulation, reliability was moderate for all sites at 2 weeks (ICC, 0.57-0.74; MDC, 24%-35%), while it was moderate at the neck (ICC, 0.54; MDC, 27%) and poor at the upper back and leg at 6 months. ICC for referred pain areas was excellent at 2 weeks (0.90) and good at 6 months (0.86). Conclusions: PPT, pressure pain tolerance, and pressure-induced referred pain should be considered reliable procedures to assess the pain-sensory profile over time. In contrast, conditioned pain modulation was shown to be unstable. Future studies prospectively analyzing the pain-sensory profile will be able to better calculate appropriate sample sizes.