Numerical Analysis on the Buckling of a Longitudinal Bar in Reinforced Concrete Members (철근 콘크리트 부재의 주근좌굴에 관한 수치해석)

  • 이용택;박재형;이원호;이리형
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1993.04a
    • /
    • pp.87-94
    • /
    • 1993
  • The study summarized in this paper is concerned with the buckling of a longitudinal bar in reinforced concrete members by numerical analysis method. The objectives of this study are to investigate the stress transfer mechanism between concrete and reinforcment and to propose a modeling equation. The result gives an acceptable agreement between the proposed modeling equation and the computer package as follows: (1) the proposed equation is a possible prediction of the strain softening of concrete and reinforcement buckling. (2) the buckling of longitudinal bars is mainly influenced by the spacing of hoops and the location of the bar.

  • PDF

A Study on the Bond Strength of Wall-Slab Joint of Steel Plate-Concrete Structures (SC구조의 벽-바닥 접합부의 정착강도에 관한 연구)

  • Choi, Kyong-Min;Kim, Ki-Sung;Kim, Byoung-Kook;Kim, Won-Ki;Choi, Oan-Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.321-324
    • /
    • 2006
  • An experimental study on the bond strength of wall-slab joint in SC(steel plate-concrete) structure was performed. Six-full scale specimens were tested. Specimens were constructed with key variables, such as, development length, location of the bar and quantity of the shear bar. The experimental results, show that as the development length and quantity of the shear bar increase, the bond strength increases. As the bars is located on the inside the stud bolt, the bond performance was highly increased compared to the bars located out of plane of the stud bolts.

  • PDF

Numerical Analysis on Buckling of Longitudinal Bar in Reinforced Concrete Columns (철근콘크리트 기둥의 구조좌굴에 관한 수치해석)

  • 이리형;박재형;이용택
    • Computational Structural Engineering
    • /
    • v.8 no.2
    • /
    • pp.73-84
    • /
    • 1995
  • The study summarized in this paper is concerned with the buckling of longitudinal bars in reinforced concrete columns with numerical analysis method. The objectives of this study are (1) to investigate the stress transfer mechanism between concrete and reinforcement and (2) to propose a modeling equation. The results give an acceptable agreement between the proposed modeling equation and published computer packages as follows; (1) the proposed equation is a possible of strain softening of concrete and buckling of reinforcement. (2) the buckling of longitudinal bar is mainly influenced by spacing of hoop and location of the bar

  • PDF

Experimental Study on the Precast Concrete Joint using Re-bar Debonding and Cutting Technique (철근 비부착 및 절단 기법을 사용한 PC 접합부의 실험적 연구)

  • Yi, Waon-Ho;Moon, Jung-Ho;Lee, Yong-Jae;Lee, Han-Jun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.2 no.4 s.7
    • /
    • pp.131-141
    • /
    • 2002
  • Precast concrete (PC) panels are often used as retaining walls to support soil pressure. In such a case, the panels should be connected at the location where PC panels meet with a buttress. However, it is not easy to provide enough development length for the reinforcing steels due to the limited width of the buttress. If it happens, the width of buttress should be increased as large enough although it is not desirable. The critical section required for providing the development length is always located where the flexural moment is maximum. Thus it is the place the buttress width ends. Also it is the place that the reinforcing steels stressed to maximum. However, it is possible to make differentiate between the maximum moment location and the most stressed location of reinforcing steels. It means that the most stressed location of reinforcing steels, the critical section, can be moved to the other place where the moment is not maximum. New critical location will have less moment than that of buttress width ends. In consequence, the development length would be longer than that of the typical way of construction. Debonding or cutting technique make it possible to reduce the moment strength of a section. Therefore reinforcing steels are debonded or cut to have a desired flexural strength at a desired place. In this study, five test specimens in full scale were erected to examine the effects of critical section movement in PC panel joints. Test parameters were the length variations of debonded and cut reinforcing steels. The test results showed that the debonding or cutting technique could be used to lengthen the development length in the joint of PC panels.

An Experimental Study on the Bond Splitting Strength between Composite Concrete and Deformed rebar (복합콘크리트와 이형 철근간의 부착강도에 관한 실험적 연구)

  • Yoon, Seung-Joe;Ho, SeungWoung
    • Journal of the Regional Association of Architectural Institute of Korea
    • /
    • v.21 no.3
    • /
    • pp.87-92
    • /
    • 2019
  • To relieve noise between floors in Korea, recent domestic and overseas studies have been developing materials that have the properties of ceramic, which is an inorganic compound, and polymer, which is an organic compound, to introduce a new function to polymer. This study conducted a bending strength experiment between re-bar and new composite concrete mixing POSS (Polyhedral Oligomeric Silses-quioxanes) nano complex on the inside of concrete, and by assembling the inside of each concrete with 3 and 4 main re-bars as an experiment to supplement various problems that occur by the expression of this strength and the distribution of the reinforcement. The number of the main re-bars. and the direction of laying the concrete were applied as the principal variables of the experiment. Upon experiment, there were no differences in the bond strength based on the location of the main re-bar, and a 2 % increase in the bond strength was shown in the specimen laid in the same direction as the main re-bar in comparison to that of the specimen laid in a different direction from the main re-bar. The experiment results displayed that the composite concrete had uniform performance based on the rapid reaction speed of POSS nano complex.

Physical Condition and User's Satisfaction on the Commom Public Areas of High School Dormitory in Local Area (지방 고등학교 기숙사의 공동생활공간에 대한 이용실태 및 사용자 만족도)

  • Choi, Byungsook;An, Jinsook
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.14 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • This study was to analyze physical condition on the dormitory high school in Jeonju City, and find out users' satisfaction on that. This was going to contribute to the directions of it's physical environmental improvement. This was performed by a questionnaire survey method. Data were collected from 200 students, who had been dwelling 4 high school dormitories in Jeonju City. Through analyzing those data about library, diningroom, laundry room, break room, computer room, restroom, shower room, hall lounge, and snack bar in a dormitory, the results are as follows. First, students thought some physical conditions to be inconvenient in an distracted study atmosphere and hard furniture of library, a bad location of diningroom, a short laundry machine, lack of tables in a break room, a short performance and supply computer, a small space and short toilet in restroom, and a short of hall lounge and snack bar. Second, the students' satisfaction of common public areas in dormitory was 3.39 score. Students were concerned with library and restroom shower room through analyzing satisfied and unsatisfied areas. Third, they needed to improve heating, cooling, and noise in common areas of dormitory, and needed to support a breakroom and snack bar. Conclusively, library, restroom shower room, break room, and snack bar were important common areas, and indoor environmental elements - heating, cooling and noise- were important in high school dormitory.

Effect of Recycled Coarse Aggregate (RCA) Replacement Level on the Bond Behaviour between RCA Concrete and Deformed Rebars (순환 굵은골재의 혼입률에 따른 콘크리트와 이형철근의 부착 거동)

  • Jang, Yong-Heon;Choi, Ki-Sun;You, Young-Chan;Kim, Keung-Hwan;Yun, Hyun-Do
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.1
    • /
    • pp.123-130
    • /
    • 2010
  • In this study, mixed recycled coarse aggregate (RCA) was produced by mixing RCA from waste concrete in order to evaluate a new method of RCA production. Bond strength between reinforcing bars and RCA concrete was qualitatively evaluated as a part of continuous studies to establish design code of reinforced concrete structural members using recycled aggregate. For practical application, specimens were manufactured with the ready mix RCA concrete. Parameters investigated include: concrete compressive strength (i.e 21, 27 and 40 MPa), replacement levels (i.e 0, 30, 60 and 100%), bar position (i.e vertical and horizontal) and bar location (75 and 225 mm). For the pull-out test, each specimen was in the form of a cube, with each side of 150 mm in length and a deformed bar, 16 mm in diameter, was embedded in the center of each specimen. From the test results, the most of HT type specimen with compressive strength of 21 and 27 MPa showed lower bond strength than the ones provided in CEB-FIP and considered in reinforcement location factor ($\alpha\;=\;1.3$). It was reasoned that bonded area of top bar specimen was reduced at the soffit of reinforcement because of bleed water of fresh concrete. Therefore the reinforcement location factor in current KCI design code should be reviewed and modified.

Development of non-destructive method of detecting steel bars corrosion in bridge decks

  • Sadeghi, Javad;Rezvani, Farshad Hashemi
    • Structural Engineering and Mechanics
    • /
    • v.46 no.5
    • /
    • pp.615-627
    • /
    • 2013
  • One of the most common defects in reinforced concrete bridge decks is corrosion of steel reinforcing bars. This invisible defect reduces the deck stiffness and affects the bridge's serviceability. Regular monitoring of the bridge is required to detect and control this type of damage and in turn, minimize repair costs. Because the corrosion is hidden within the deck, this type of damage cannot be easily detected by visual inspection and therefore, an alternative damage detection technique is required. This research develops a non-destructive method for detecting reinforcing bar corrosion. Experimental modal analysis, as a non-destructive testing technique, and finite element (FE) model updating are used in this method. The location and size of corrosion in the reinforcing bars is predicted by creating a finite element model of bridge deck and updating the model characteristics to match the experimental results. The practicality and applicability of the proposed method were evaluated by applying the new technique to a two spans bridge for monitoring steel bar corrosion. It was shown that the proposed method can predict the location and size of reinforcing bars corrosion with reasonable accuracy.

Bar Code Location Algorithm Using Pixel Gradient and Labeling (화소의 기울기와 레이블링을 이용한 효율적인 바코드 검출 알고리즘)

  • Kim, Seung-Jin;Jung, Yoon-Su;Kim, Bong-Seok;Won, Jong-Un;Won, Chul-Ho;Cho, Jin-Ho;Lee, Kuhn-Il
    • The KIPS Transactions:PartD
    • /
    • v.10D no.7
    • /
    • pp.1171-1176
    • /
    • 2003
  • In this paper, we propose an effective bar code detection algorithm using the feature analysis and the labeling. After computing the direction of pixels using four line operators, we obtain the histogram about the direction of pixels by a block unit. We calculate the difference between the maximum value and the minimum value of the histogram and consider the block that have the largest difference value as the block of the bar code region. We get the line passing by the bar code region with the selected block but detect blocks of interest to get the more accurate line. The largest difference value is used to decide the threshold value to obtain the binary image. After obtaining a binary image, we do the labeling about the binary image. Therefore, we find blocks of interest in the bar code region. We calculate the gradient and the center of the bar code with blocks of interest, and then get the line passing by the bar code and detect the bar code. As we obtain the gray level of the line passing by the bar code, we grasp the information of the bar code.

Simultaneous nitrification and denitrification by using ejector type microbubble generator in a single reactor

  • Lim, Ji-Young;Kim, Hyun-Sik;Park, Soo-Young;Kim, Jin-Han
    • Environmental Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.251-257
    • /
    • 2020
  • This study was performed to verify the possibility of nitrification and denitrification in a single reactor. In batch type experiment, optimal point of experimental conditions could be found by performing the experiments. When supply location of microbubbles was located at half of width of the aeration tank and operating pressure of 0.5 bar, it was possible for zones in the aeration tank to be separated into anoxic and aerobic by controlling air suction rate according to operating pressure of the generator. To be specific, the concentration of dissolved oxygen (DO) in zone 1 and 2 of the aeration tank could be maintained as less than 0.5 mg/L. Also, in the case of concentration of oxygen in zone 3 and 4, the concentration of DO was increased up to 1.7 mg/L due to effects of microbubbles. In continuous flow type experiment based on the results of batch type experiments, the removal efficiency of nitrogen based on T-N was observed as 39.83% at operating pressure of 0.5 bar and 46.51% at operating pressure of 1 bar so it was able to know that sufficient air suction rate should be required for nitrification. Also, denitrification process could be achieved in a single reactor by using ejector type microbubble generator and organic matter and suspended solid could be removed. Therefore, it was possible to verify that zones could be separated into anoxic and aerobic and nitrification and denitrification process could be performed in a single reactor.