• 제목/요약/키워드: localized failure

검색결과 169건 처리시간 0.031초

지중 RC 도시지하철고 구조물의 내진설계 (A Seismic Design of RC Underground Subway Structure)

  • 정제평;임동원;이성로;김우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.357-362
    • /
    • 2000
  • This Paper presents dynamic analysis of underground R/C Subway Structure, subjected to seismic actions. Earthquakes brought serious damage to RC subway Structure. Foe studying the collapse mechanism of underground RC Subway, seismic of a subway station is simulated in using FEM program ASP2000 of two-dimension based on the path dependent RC elastic model, soil foundation and interfacial models. The shear failure of intermediate vertical columns is founds to be the major cause of the structural collapse. According to FEM simulation of the failure mechanism, it is considered that the RC column would lose axial load carrying capacity after the occurrence of the localized diagonal shear cracks , and sudden failure of the outer frame would be followed. Specially, the shear stress in the middle slab reaches maximum shear capacity. So, the Structure would fail in the middle slab as a result of erasing the vertical ground motion computation.

  • PDF

유리-탄소 하이브리드 복합재료의 파괴인성에 관한 연구 (A Study on the Fracture Toughness of Glass-Carbon Hybrid Composites)

  • 노호섭;고성위
    • 수산해양기술연구
    • /
    • 제28권3호
    • /
    • pp.295-305
    • /
    • 1992
  • The critical strain energy release rate and the failure mechanisms of glass-carbon epoxy resin hybrid composites are investigated in the temperature range of the ambient temperature to 8$0^{\circ}C$. The direction of laminates and the volume fraction are [(+45, -45, 0, 0) sub(2) ] sub(s), 50%, respectively. The major failure mechanisms of these composites are studied using the scanning electron microscope for the fracture surface. Results are summarized as follows: 1) The critical strain energy release rate shows a maximum at ambient temperature and it tends to decrease as temperature goes up. 2) The critical strain energy release rate increases as the content of glass increases, and especially shows dramatic increase for the high glass fiber content specimens. 3) Major failure mechanisms can be classfied such as localized shear yielding, fiber-matrix debonding, matrix micro-cracking, and fiber pull-out and/or delamination.

  • PDF

초경합금의 미세방전 드릴링에 관한 연구 (A Study on Micro ED-Drilling of cemented carbide)

  • 김창호;강수호
    • 한국기계가공학회지
    • /
    • 제9권5호
    • /
    • pp.1-6
    • /
    • 2010
  • The wavelet transform is a popular tool for studying intermittent and localized phenomena in signals. In this study the wavelet transform of cutting force signals was conducted for the detection of a tool failure in turning process. We used the Daubechies wavelet analyzing function to detect a sudden change in cutting signal level. A preliminary stepped workpiece which had intentionally a hard condition was cut by the inserted cermet tool and a tool dynamometer obtained cutting force signals. From the results of the wavelet transform, the obtained signals were divided into approximation terms and detailed terms. At tool failure, the approximation signals were suddenly increased and the detailed signals were extremely oscillated just before tool failure.

집중호우에 의한 도로시설물 피해 원인 및 대책 (Cause and Measure of Road Structures for Localized Torrential Downpour)

  • 이용수;최창호;정하익;권기환
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.458-461
    • /
    • 2007
  • 이 논문은 2006년 집중호우로 인하여 발생한 강원지역의 도로시설물 피해 원인 및 대책에 대하여 기술하였다. 최근 집중호우로 인하여 산악지형에 위치한 도로는 계곡하천의 급류와 계곡 상류지역에서 발생한 토석류 등에 의하여 유실 및 붕괴가 발생하고 있다. 피해의 주요 원인은 계곡부의 산지하천의 급류에 의한 만곡부 및 수충부의 침식과 토석류 및 부유목 등에 의한 횡단배수암거의 통수능 부족 등이다. 따라서, 산악지형의 도로시설물에 대하여 주요 원인에 대하여 도로 배수시설물의 확대 및 토석류 대책 등이 필요하다.

  • PDF

절토에 의한 상부자연지반의 붕괴 특성 연구 (A Failure of disturbed natural-slope ground caused by cutting slope)

  • 나광희;장범수;신창건;김용수;최용기
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.629-634
    • /
    • 2004
  • When it was a localized torrential downpour last year, a natural-slope fell down above a cut-slope. They were caused that stress was opened by cutting slope, ground water level rose quickly and a ground mass strength fell etc. So volume of ground mass increase because of that reasons, finally the disturbed ground was collapse. Therefore I suggest that safety of a natural-slope is a consideration, when a cut-slope is made by cutting ground.

  • PDF

이송모터 전류신호의 Wavelet 변환에 의한 공구파손 식별 (Identification of Tool Breakage Signal Using Wavelet Transform of Feed Motor Current in Milling Operations)

  • Park, H.Y.;Kim, S.H.;Lee, M.H.
    • 한국정밀공학회지
    • /
    • 제13권9호
    • /
    • pp.31-37
    • /
    • 1996
  • This Paper is concerned with effective signal identification method for tool breakage and micro chipping using discrete wavelet transform of feed motor current in milling operations. The wavelet transform uses an analyzing waveletfunction which is localized in both frequency and time domain to detect subtle time localized changes in input signals. The changing pattern of wavelet coefficient is continuously compared to detect tool breakage and micro chipping over one spindle revolution. The results indicate that the wavelet transform can identify tool failure with much greater sensi- tivity than the time domain monitoring and frequency domain monitoring such as FFT. Experimental results are presented to support the proposed scheme.

  • PDF

심근내로 파급된 심낭내 결핵성 농양 수술 치험 1례 (Intrapericardial Tuberculous Abscess Invading Myocardium - A Case Report -)

  • 김현경
    • Journal of Chest Surgery
    • /
    • 제25권11호
    • /
    • pp.1245-1249
    • /
    • 1992
  • Tuberculosis developed in the pericardium usually occurs as diffuse constrictive pericarditis or effusive pericarditis which contains much pericardial effusion. But types such as localized abscess or tuberculoma are very rare. Myocardial tuberculosis is also very rare and mainly extended directly from hilar lymph node or spreaded hematogenously in miliary tuberculosis. It is known to be able to make arrhythmia or heart failure by invasion of conduction system or myocardial muscle mass, but it is usually discovered by incidental postmortem autopsy and rarely concerned by clinical basis. Recently we have experienced a case of localized intrapericardial tuberculous abscess which extended to myocardium and operated that successfully. So we would report them with reference study.

  • PDF

Localized Corrosion of Zn-Plated Carbon Steel Used as a Fire Sprinkler Pipe

  • Lee, Jin Hee;Lee, You-Kee;Lee, Kyu Hwan;Kim, Dong-Kyu;Lee, Sung Gun;Lee, Sang Hwa;Kim, Insoo
    • Corrosion Science and Technology
    • /
    • 제8권4호
    • /
    • pp.148-152
    • /
    • 2009
  • The failure of a Zn-plated carbon steel pipe that served as a fire sprinkler was investigated in terms of the pipe's corrosion products. The pipes leaked through holes formed beneath the tubercles. The formation of oxygen concentration cell involves colonization of metal surface by aerobic bacteria or other slime formers, and anodic reaction beneath tubercle is accelerated by the presence of SRB, leading to the formation of hole beneath tubercle.

Numerical simulation of the effects of localized cladding oxidation on LWR fuel rod design limits using a SLICE-DO model of the FALCON code

  • Khvostov, Grigori
    • Nuclear Engineering and Technology
    • /
    • 제52권1호
    • /
    • pp.135-147
    • /
    • 2020
  • A methodology for evaluation of mechanical and thermal effects of localized non-axisymmetric oxidation in zircaloy claddings on LWR fuel reliability is proposed. To this end, the basic capabilities of the FALCON fuel behaviour code are used. Examples of methodology application to adjustment of selected operational limits for modern BWR fuel rods, to capture effects of the excess local oxidation, are presented. Specifically, the limiting rod internal pressure for the onset of cladding lift-off is reduced, depending on initial excess oxidation spot sizes. Also, the power limits for Anticipated Operational Occurrences are adjusted, to preclude fuel melting and cladding failure due to PCMI and PCI-SCC in the affected fuel rods.

3차원 수리모형을 이용한 농업용 저수지의 파괴확률에 따른 하류부 피해예측 모델 개발 (Development of Downstream Flood Damage Prediction Model Based on Probability of Failure Analysis in Agricultural Reservoir)

  • 전정배;윤성수;최원
    • 한국농공학회논문집
    • /
    • 제62권3호
    • /
    • pp.95-107
    • /
    • 2020
  • The failures of the agricultural reservoirs that most have more than 50 years, have increased due to the abnormal weather and localized heavy rains. There are many studies on the prediction of damage from reservoir collapse, however, these referenced studies focused on evaluating reservoir collapse as single unit and applyed to one and two dimensional hydrodynamic model to identify the fluid flow. This study is to estimate failure probability of spillway, sliding, bearing capacity and overflowing targeting small and medium scale agricultural reservoirs. In addition, we calculate failure probability by complex mode. Moreover, we predict downstream flood damage by reservoir failure applying three dimensional hydrodynamic model. When the reservoir destroyed, the results are as follows; (1) the flow of fluid proceeds to same stream direction and to a lower slope by potential and kinetic energy; (2) The predicted damage in downstream is evaluated that damage due to building destruction is the highest.