• 제목/요약/키워드: local wind

검색결과 710건 처리시간 0.026초

Aerodynamic measurements of across-wind loads and responses of tapered super high-rise buildings

  • Deng, Ting;Yu, Xianfeng;Xie, Zhuangning
    • Wind and Structures
    • /
    • 제21권3호
    • /
    • pp.331-352
    • /
    • 2015
  • A series of wind tunnel tests were conducted on tapered super high-rise buildings with a square cross section by applying synchronous pressure measurement technology. The effects of global strategy of chamfered modification on aerodynamic loads and wind-induced responses were investigated. Moreover, local aerodynamic strategies of opening a ventilation slot in the corner of equipment and refuge floors were carried out. Results show that the global strategy of tapered elevation increased the vortex shedding frequency, but reduced vortex shedding energy, leading to reduction of across-wind aerodynamic loads and responses. Chamfered modification suppressed the across-wind vortex shedding effect on tapered buildings. Opening the ventilation slot further suppressed the strength of vortex shedding and reduced the residual energy related to vortex shedding in aerodynamic loads of chamfered buildings. Finally, the optimized locations of local aerodynamic strategies were suggested.

아치형 단동하우스의 풍력계수 분포에 관한 연구 (Distribution of Wind Force Coefficients on the Single-span Arched House)

  • 이석건;이현우
    • 생물환경조절학회지
    • /
    • 제1권1호
    • /
    • pp.28-36
    • /
    • 1992
  • The wind pressure distributions were analyzed to provide fundamental criteria for the structural design on e single-span arched house according to the wind directions through the wind tunnel experiment. In order to investigate the wind force distributions, the variation of the wind force coefficients, the mean wind force coefficients, the drag force coefficients and the lift force coefficients were estimated by using the experimental data. The results obtained are as follows: 1. When the wind direction was normal to the wall, the maximum positive wind pressure along the height of the wall occurred approximately at two-thirds of the wall height because of the effects of boundary layer flow. 2. When the wind direction was 30$^{\circ}$ to the wall, the maximum positive wind force occurred at the windward edge of the wall. When the wind direction was parallel to the wall, the maximum negative wind force occurred at the windward edge of the wall. 3. The maximum negative wind force along the width of the roof appeared around the width ratio, 0.4, and that along the length of the roof appeared around the length ratio, 0.5. 4. According to the results of the mean wind force coefficients analysis, the maximum negative wind force occurred on the roof at the wind direction of 30$^{\circ}$. 5. The wind forces at the wind direction of 30$^{\circ}$ instead of 0$^{\circ}$ are recommended in the structural design of supports for a house. 6. To prevent partial damage of a house structure by wind forces, the local wind forces should be considered to the structural design of a house.

  • PDF

대기오염 확산 해석을 위한 포항지역 기상장 연구 -바람장 수치모의- (A Study of Atmospheric Field around the Pohang for Dispersion Analysis of Air Pollutants -Numerical Simulation of Wind Field-)

  • 이화운;정우식;김현구;이순환
    • 한국대기환경학회지
    • /
    • 제20권1호
    • /
    • pp.1-15
    • /
    • 2004
  • Sea/land circulation system is a representative mesoscale local circulation system in coastal area. In this study, wind fields around coastal area. Pohang, which is affected by this system was investigated and its detailed characteristic analysis was carried out. The following can be found out from the numerical simulation. Generally, at nighttime mountain winds prevail and land breeze toward the coastal area was well simulated During daytime, valley wind and sea breeze was simulated in detail. Especially, as a result of analyzing the land breeze path, it could be found along the coastline as it flows out through low land coastal area. In order to investigate the accuracy of model results. wind speed, temperature and wind direction of continuous typical sea/land breeze occurrence day was compared with observation data. Analyzing the characteristics of local circulation system was very hard because of horizontally sparse observation data but from the above result, a numerical simulation using RAMS, which satisfies the spatial high resolution, will provide more accurate results.

국지풍모델을 이용한 광양만권의 이류확산 수치모의 (Numerical Simulation of Advection and Diffusion using the Local Wind Model in Kwangyang Bay, Korea)

  • 이상득;김인기
    • 한국대기환경학회지
    • /
    • 제18권1호
    • /
    • pp.1-10
    • /
    • 2002
  • A three-dimensional numerical model which involved the nesting method was developed to reproduce the wind circulation of Kwangyang Bay area which comprises complicated mountains and sea topograph. The calculated results indicated geographical effects of Kwangyang Bay area, sea/land breezes and mount-valley wind which are local circular winds. We also noticed that the northern inland area of Kwangyang Bay formed the very complex wind systems under the influence of such geographic effects when a land breeze was not formed. A good agreement was found between predicted and observed values of temperature. In addition, the calculated results of the wind direction and the wind velocity are in accord with the observed values. They showed only a slight difference in between predicted and the observed values, when the sea breeze and the land breeze are changing.

아치형 2연동하우스의 풍력계수 분포에 관한 연구 (Distribution of Wind Force Coefficients on the Two-span Arched House)

  • 이석건;이현우
    • 생물환경조절학회지
    • /
    • 제1권2호
    • /
    • pp.142-147
    • /
    • 1992
  • The wind pressure distributions were analyzed to provide fundamental criteria for the structural design on the two-span arched house according to the wind directions through the wind tunnel experiment. In order to investigate the wind force distributions, the variation of the wind force coefficients, the mean wind force coefficients, the drag force coefficients and the lift force coefficients were estimated using the experimental data. The results obtained are as follows : 1. The variation of the wind force with wind directions on the side walls was the greatest at the upwind edge of the walls. 2. The maximum negative wind force along the length of the roof appeared at the upwind edge at the wind direction of 60$^{\circ}$. 3. The maximum negative wind force along the width of the roof appeared at the width ratio and wind direction of 0$^{\circ}$ and 0.4 in the first house and 0.6 and 30$^{\circ}$ in the second house, respectively. 4. The mean negative wind force on the side walls of the first house at the wind direction of 0$^{\circ}$ was far greater than that of the second house, and the maximum negative wind force on the roof occurred at the wind direction of 30$^{\circ}$. 5. The maximum lift force appeared on the second house at the wind direction of 30$^{\circ}$, but the lift force on the first house was far greater than that on the second house at the wind direction of 0$^{\circ}$. 6. The parts to be considered for the local wind forces were the edges of the walls, and the edges of the x-direction and the width ratio, 0.4 of the y-direction in the roofs.

  • PDF

국지순환풍 모델을 이용한 광양만권 대기오염물질의 수치모델링 (Numerical Modeling of Pollutants using Local Wind Model in Gwangyang Bay, Korea)

  • 이상득
    • 한국대기환경학회지
    • /
    • 제19권1호
    • /
    • pp.13-23
    • /
    • 2003
  • A local wind model and a three dimensional local environmental model including advection, diffusion, deposition. and photochemical reactions were performed at Gwangyang Bay, Korea, to predict air flow and air pollutants concentrations. A large grid was used, and nesting method was employed for small grid calculation. From the meterological module simulation, we were able to reproduce local wind characteristics such as sea/land winds and mountain/valley winds simulation at Gwangyang Bay. In addition, the concentration module showed high concentration regions at Yosu industrial complex, Gwangyang steel company. and Container anchor. It was also seen that air pollutants were dispersed by sea/land winds. A comparison between the measurement and the prediction of sulfur dioxide and nitric oxide, which are relatively low-reacted pollutants, was performed. However, the measured nitrogen dioxide and ozone concentrations were higher than the simulated ones. Particularly, ozone concentration between 8 a..m. and 8 p.m. agreed well, but the measured ozone during the rest of time were generally higher.

배경지역에서의 국지오염원의 영향: 2000년 3월 고산 측정결과 (The Effect of Local Air Pollutants in a Background Area: Measurements at Gosan in March 2000)

  • 김나경;김용표
    • 한국대기환경학회지
    • /
    • 제22권6호
    • /
    • pp.821-830
    • /
    • 2006
  • To identify the effect of local air pollutants on the $PM_{2.5}$ level at Gosan, $PM_{2.5}$ composition data, continuous $O_3,\;NO_x,\;SO_2,\;CO$ data, VOCs data, surface wind characteristics, and backward trajectory analysis results were analyzed for the measurements in March 2000 during which high concentrations of mass and anthropogenic ionic species were reported. It was found that the combination of surface wind and continuous gaseous species data can help to identify local effect in Jeju Island. Even in a high $PM_{2.5}$ level case mainly affected by long range transport from China, it was Identified that local effects were also significant for both the duration and pollutants' levels.

풍력발전기의 출력 안정화를 위한 에너지 저장장치 용량 산정 사례연구 (Analysis on Required Capacity of Energy Storage System to Mitigate Wind Power Fluctuation)

  • 강민혁;채상헌;안진홍;김일환
    • 한국태양에너지학회 논문집
    • /
    • 제37권6호
    • /
    • pp.59-68
    • /
    • 2017
  • In accordance with the policy of local government, the large scale of wind farms have been installed in Jeju power system. However, The intermittent characteristics of wind power output may cause grid voltage and frequency variation, especially in weak power system. One of the solution to solve this problem is installation of Energy storage system (ESS). In this case, the ESS will regulate the active power generated from wind farm to mitigate fluctuation. Actually, the local government of Jeju island constructed ESS connected to Hangwon wind turbine in 2016. From this point, this paper analyzes requirement capacity of ESS to mitigate wind power fluctuation based on measured data from Hangwon wind turbine and ESS. The simulation results will be carried out by Matlab program.

해상풍력 주민수용성 연구: 군산 말도를 중심으로 (A Study on Local Acceptance of Offshore Wind Farm: Focus on Maldo, Gunsan)

  • 이상혁;박재필
    • 신재생에너지
    • /
    • 제16권2호
    • /
    • pp.20-27
    • /
    • 2020
  • According to "The Renewable Energy 3020 Implementation Plan", offshore wind power accounts for 12 GW of the total new capacity of 48.7 GW. Like the south-west 2.5 GW offshore wind farm case, government-led development has had difficulty in securing the residents' acceptability. This study contributes to the study of local acceptance by analyzing the perceptions of Maldo residents. To this end, in-depth interviews were conducted with the head of a village and fishing village chief, and the entire contents of the interview were revised and analyzed. The cognitive structure of the stakeholders could be confirmed using semantic network analysis, which analyzes the network structure among words. Based on the analysis results, focusing on the identity frames related to the compensation process from previous national projects, gain vs. loss frames act as the dominant frame in terms of profits from offshore wind turbines. To invigorate offshore wind farms, the policy implications as follows. First, a negotiation organization should be organized to deal with strategic opposition by fishes. Second, installing offshore wind farms on a public water body will result in demands for compensation from various actors, and a licensed fishing territory as an offshore wind farm installation site should be considered.

Wind effects on a large cantilevered flat roof: loading characteristics and strategy of reduction

  • Fu, J.Y.;Li, Q.S.;Xie, Z.N.
    • Wind and Structures
    • /
    • 제8권5호
    • /
    • pp.357-372
    • /
    • 2005
  • Mean and extreme pressure distributions on a large cantilevered flat roof model are measured in a boundary layer wind tunnel. The largest peak suction values are observed from pressure taps beneath conical "delta-wing type" corner vortices that occur for oblique winds, then the characteristics and causes of the local peak suctions are discussed in detail. Power spectra of fluctuating wind pressures measured from some typical taps located at the roof edges under different wind directions are presented, and coherence functions of fluctuating pressures are also obtained. Based on these results, it is verified that the peak suctions are highly correlated with the conical vortices. Furthermore, according to the characteristics of wind loads on the roof, an aerodynamic solution to minimize the peak suctions by venting the leading edges and the corners of the roof is recommended. The experimental results show that the suggested strategy can effectively control the generation of the conical vortices and make a reduction of 50% in mean pressures and 25% in extreme local pressures at wind sensitive locations on the roof.