• Title/Summary/Keyword: local linear method

Search Result 420, Processing Time 0.029 seconds

Technical Application and Analysis for Reduction of Water Loss in Water Distribution Systems (상수도 관망의 유수율 제고 기술의 적용 및 분석)

  • Kim, Ju-Hwan;Lee, Doo-Jin;Bae, Cheol-Ho;Woo, Hyung-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.260-266
    • /
    • 2009
  • Non-revenue water reduction(NRW) technologies are implemented to evaluate and manage leakages scientifically in water distribution systems under local governments. A development of quantitative leakage indicator by measuring minimum night flow, pressure control policy by installation of PRV(pressure reducing valve) and the establishment of leakage prevention schemes by residual life modeling of deteriorated water pipes are reviewed and studied. Estimation models of allowable leakage are developed by measuring and analyzing minimum night flow at residential and commercial area in Nonsan city, which is suggested from UK water industry and can improve an existing leakage indicator for the evaluation of non-revenue water. Also, pressure control method is applied and analyzed to Uti distribution area in Sacheon city in the operation aspect. As results, $466\;m^3/day$ of leakage can be reduced and it is expected that 113million won of annual cost can be saved. In the part of corrosion velocity and residual life assessment, non-linear prediction models of residual thickness are proposed by assessment of corrosion velocity based on exposure years, soil and water quality etc., since the deteriorated water pipe play a major role to increase leakage. It is expected that collection data and analyzing results can be applied effectively and positively to reduce non-revenue water by accumulating surveying data and verifying the results in the business field of water distribution systems under local governments.

  • PDF

Professional Job Perception, Job Stress and Job Satisfaction of Doctors Practicing in Local Clinic in Daegu City (개원의사들의 전문직업성과 직무스트레스가 직업만족도에 미치는 영향)

  • Jin, Dae-Gu;Kang, Yune-Sik;Cho, Yong-Kee;Lee, Sang-Won;Kim, Jong-Yeon;Ahn, Soon-Gi;Chun, Byung-Yeol;Yeh, Min-Hae;Kam, Sin
    • Journal of Preventive Medicine and Public Health
    • /
    • v.36 no.2
    • /
    • pp.153-162
    • /
    • 2003
  • Objective : This study was conducted in order to investigate professional job perception, job stress and job satisfaction in doctors. Method : The authors conducted a survey using a self-administered questionnaire, conducted between August and September,2001. The study subjects were 457 doctors practicing at local clinics in Daegu City. Results : For the professionalism scale, the score for 'sense of calling to field' and 'feeling of autonomy' were relatively high, Age, working hours per day, and perception of socioeconomic status significantly influenced the professionalism scale scores (p<0.01). For the job stress scale, the scores for 'clinical responsibility/decision' factor were the highest of all the surveyed factors. Working hours per day significantly influenced the job stress scores (p<0.01). To investigate the overall relationship between the variables, the authors conducted a linear structural equation model analysis. The equation was statistically appropriate and a good fit. The job stress, and the professionalism factors, respectively influenced job satisfaction negatively and positively (T>2.0). The working hours per day and status perception also influenced their job satisfaction (T>2.0). Conclusion : To promote the iob satisfaction of doctors, the development of coping tools and other intervention methods are needed to increase doctor's professional job perception and reduce their job stress. Further studies are required to understand the characteristics of job satisfaction and for its promotion with doctors.

Analysis of Subwavelength Metal Hole Array Structure for the Enhancement of Quantum Dot Infrared Photodetectors

  • Ha, Jae-Du;Hwang, Jeong-U;Gang, Sang-U;No, Sam-Gyu;Lee, Sang-Jun;Kim, Jong-Su;Krishna, Sanjay;Urbas, Augustine;Ku, Zahyun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.334-334
    • /
    • 2013
  • In the past decade, the infrared detectors based on intersubband transition in quantum dots (QDs) have attracted much attention due to lower dark currents and increased lifetimes, which are in turn due a three-dimensional confinement and a reduction of scattering, respectively. In parallel, focal plane array development for infrared imaging has proceeded from the first to third generations (linear arrays, 2D arrays for staring systems, and large format with enhanced capabilities, respectively). For a step further towards the next generation of FPAs, it is envisioned that a two-dimensional metal hole array (2D-MHA) structures will improve the FPA structure by enhancing the coupling to photodetectors via local field engineering, and will enable wavelength filtering. In regard to the improved performance at certain wavelengths, it is worth pointing out the structural difference between previous 2D-MHA integrated front-illuminated single pixel devices and back-illuminated devices. Apart from the pixel linear dimension, it is a distinct difference that there is a metal cladding (composed of a number of metals for ohmic contact and the read-out integrated circuit hybridization) in the FPA between the heavily doped gallium arsenide used as the contact layer and the ROIC; on the contrary, the front-illuminated single pixel device consists of two heavily doped contact layers separated by the QD-absorber on a semi-infinite GaAs substrate. This paper is focused on analyzing the impact of a two dimensional metal hole array structure integrated to the back-illuminated quantum dots-in-a-well (DWELL) infrared photodetectors. The metal hole array consisting of subwavelength-circular holes penetrating gold layer (2DAu-CHA) provides the enhanced responsivity of DWELL infrared photodetector at certain wavelengths. The performance of 2D-Au-CHA is investigated by calculating the absorption of active layer in the DWELL structure using a finite integration technique. Simulation results show the enhanced electric fields (thereby increasing the absorption in the active layer) resulting from a surface plasmon, a guided mode, and Fabry-Perot resonances. Simulation method accomplished in this paper provides a generalized approach to optimize the design of any type of couplers integrated to infrared photodetectors.

  • PDF

An integrated framework of security tool selection using fuzzy regression and physical programming (퍼지회귀분석과 physical programming을 활용한 정보보호 도구 선정 통합 프레임워크)

  • Nguyen, Hoai-Vu;Kongsuwan, Pauline;Shin, Sang-Mun;Choi, Yong-Sun;Kim, Sang-Kyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.11
    • /
    • pp.143-156
    • /
    • 2010
  • Faced with an increase of malicious threats from the Internet as well as local area networks, many companies are considering deploying a security system. To help a decision maker select a suitable security tool, this paper proposed a three-step integrated framework using linear fuzzy regression (LFR) and physical programming (PP). First, based on the experts' estimations on security criteria, analytic hierarchy process (AHP) and quality function deployment (QFD) are employed to specify an intermediate score for each criterion and the relationship among these criteria. Next, evaluation value of each criterion is computed by using LFR. Finally, a goal programming (GP) method is customized to obtain the most appropriate security tool for an organization, considering a tradeoff among the multi-objectives associated with quality, credibility and costs, utilizing the relative weights calculated by the physical programming weights (PPW) algorithm. A numerical example provided illustrates the advantages and contributions of this approach. Proposed approach is anticipated to help a decision maker select a suitable security tool by taking advantage of experts' experience, with noises eliminated, as well as the accuracy of mathematical optimization methods.

Gaussian Noise Reduction Algorithm using Self-similarity (자기 유사성을 이용한 가우시안 노이즈 제거 알고리즘)

  • Jeon, Yougn-Eun;Eom, Min-Young;Choe, Yoon-Sik
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.5
    • /
    • pp.1-10
    • /
    • 2007
  • Most of natural images have a special property, what is called self-similarity, which is the basis of fractal image coding. Even though an image has local stationarity in several homogeneous regions, it is generally non-stationarysignal, especially in edge region. This is the main reason that poor results are induced in linear techniques. In order to overcome the difficulty we propose a non-linear technique using self-similarity in the image. In our work, an image is classified into stationary and non-stationary region with respect to sample variance. In case of stationary region, do-noising is performed as simply averaging of its neighborhoods. However, if the region is non-stationary region, stationalization is conducted as make a set of center pixels by similarity matching with respect to bMSE(block Mean Square Error). And then do-nosing is performed by Gaussian weighted averaging of center pixels of similar blocks, because the set of center pixels of similar blocks can be regarded as nearly stationary. The true image value is estimated by weighted average of the elements of the set. The experimental results show that our method has better performance and smaller variance than other methods as estimator.

The Effect of COVID-19 on Academic Satisfaction with Online Lecture Types and Contents -Perspectives of the Domestic and Foreign University Students- (코로나19로 인한 온라인 강의 형태와 콘텐츠가 학업 만족도에 미치는 영향 -국내외 대학생의 관점에서-)

  • Jo, Ji-Soo;Bae, Jeong-In
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.643-650
    • /
    • 2021
  • The purpose of this study was to evaluate the impact of lecture content on the overall academic satisfaction in non-contact online classes. The study was conducted using an online survey of 107 university students attending metropolitan, local and foreign universities for a week from August 25th, 2020 to September 2nd, 2020. The analysis methods used included descriptive statistics and chi-square distribution, Fisher's exact test, linear by linear association, and logistic regression. The result of the study showed a significant decrease in Junior by 0.025 times compared to Senior (p<.05). Furthermore, a significant decrease in the impact of recorded lectures by 0.036 times compared to a hybrid of face-to-face and online lectures (p<.05). Compared to the response 'No', the number of student's responses of 'Yes' increased significantly by 31.358 times (p<.05). Additionally, a significant increase was seen in teaching methods by 19.709 times, and academic satisfaction by 7.989 times(p<.05). In conclusion, the results imply that the quality of lecture content is also important to improve the student's satisfaction with school life, but overall management is required in the areas of appropriate teaching methods, appropriate tuition, and evaluation methods.

Radiotherapy in Medically Inoperable Early Stage Non-small Cell Lung Cancer (내과적 문제로 수술이 불가능한 조기 비소세포성 폐암에서의 방사선치료)

  • Kim, Bo-Kyoung;Park, Charn-Il
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.257-264
    • /
    • 2000
  • Purpose: For early stage non-small-cell lung cancer, surgical resection is the treatment of choice. But when the patients are not able to tolerate it because of medical problem and when refuse surgery, radiation therapy is considered an acceptable alternative. We report on the treatment results and the effect of achieving local control of primary tumors on survival end points, and analyze factors that may influence survival and local control. Materials and Method : We reviewed the medical records of 32 patients with medically inoperable non-small cell lung cancer treated at our institution from June, 1987 through June, 1997. All patients had a pathologic diagnosis of non-small cell lung cancer and were not candidate for surgical resection because of either patients refusal (4), old age (2), lung problem (21), chest wail invasion (3) and heart problems (3). In 8 patients, there were more than 2 problems. The median age of the patients was 68 years (ranging from 60 to 86 years). Histologic cell type included souamous (24), adenocarcinoma (6) and unclassiried squamous cell (2). The clinical stages of the patients were 71 in 5, 72 in 25, 73 in 2 patients. Initial tumor size was 3.0 cm in 11, between 3.0 cm and 5.0 cm in 13 and more than 5.0 cm in 8 patients. Ail patients had taken chest x-rays, chest CT, abdomen USG and bone scan. Radiotherapy was delivered using 6 MV or 10 MV linear accelerators. The doses of primary tumor were the ranging from 54.0 Gy to 68.8 Gy (median; 61.2 Gy). The duration of treatment was from 37 days through 64 days (median; 0.5 days) and there was no treatment interruption except 1 patient due to poor general status. In 12 patients, concomitant boost technique was used. There were no neoadjuvant or adjuvant treatments such as surgery or chemotherapy. The period of follow-up was ranging from 2 months through 93 months (median; 23 months). Survival was measured from the date radiation therapy was initiated. Results : The overall survival rate was 44.6$\%$ at 2 years and 24.5$\%$ at 5 years, with the median survival time of 23 months. of the 25 deaths, 7 patients died of intercurrent illness, and cause-specific survival rate was 61.0$\%$ at 2 years and 33.5$\%$ at 5 years. The disease-free survival rate was 38.9$\%$ at 2 years and 28.3$\%$ at 5 years. The local-relapse-free survival rate was 35.1$\%$, 28.1$\%$, respectively. On univariate analysis, tumor size was significant variable of overall survival (p=0.0015, 95$\%$ C.1.; 1.4814-5.2815), disease-free survival (P=0.0022, 95$\%$ C.1., 1.4707-5.7780) and local-relapse-free survival (p=0.0015, 95$\%$ C.1., 1.2910- 4.1197). 7 stage was significant variable of overall survival (p=0.0395, 95$\%$ C.1.; 1.1084-55.9112) and had borderline significance on disease-free survival (p=0.0649, 95$\%$ C.1.; 0.8888-50.7123) and local-relapse-free survival (p=0.0582, 95$\%$ C,1.; 0.9342-52.7755). On multivariate analysis, tumor size had borderline significance on overall survival (p=0.6919, 955 C.1., 0.9610-5.1277) and local-relapse-free survival ( p=0.0585, 95$\%$ C.1.; 0.9720-4.9657). Tumor size was also significant variable of disease-free survival (p=0.0317, 95% C.1.; 1.1028-8.4968). Conclusion : Radical radiotherapy is an effective treatment for small (71 or f3 cm) tumors and can be offered as alternative to surgery in elderly or infirmed patients. But when the size of tumor is larger than 5 cm, there were few long-term survivors treated with radiotherapy alone. The use of hypefractionated radiotherapy, endobronchial boost, radisensitizer and conformal or IMRT should be consider to improve the local control rate and disease-specific survival rate.

  • PDF

Performance Evaluation of a W-Band Waveguide Noise Measurement System for Calibrating Noise Sources (잡음원 교정용 W-대역 도파관 잡음 측정 시스템의 성능 평가)

  • Kang, Tae-Weon;Kim, Jeong-Hwan;Kwon, Jae-Yong;Kang, Jin-Seob
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.2
    • /
    • pp.180-188
    • /
    • 2013
  • A W-band waveguide noise measurement system for calibrating noise sources was implemented and its basic characteristics were discussed. The measurement system consists of a commercial noise figure analyzer, a full W-band frequency converter, and a local oscillator. To measure the noise temperature of a noise source, the Y-factor method is generally used. Since the Y-factor method is based on the assumption that the receiving system is linear, linearity is one of important performance parameters of the measurement system. In this paper, the linearities for mixer, intermediate frequency(IF), and RF parts were evaluated to be 0.24 dB, 0.05 dB, and 0.20 dB, respectively. The noise figure of the measurement system evaluated is 5 dB to 17 dB in W-band. The measurement system can be used to measure thermal noise characteristics of electronic and electrical devices, equipments, and systems as well as to calibrate noise sources.

A Study on Polynomial Pre-Distortion Technique Using PAPR Reduction Method in the Next Generation Mobile Communication System (차세대 이동통신 시스템에 PAPR 감소기법을 적용한 다항식 사전왜곡 기법에 관한 연구)

  • Kim, Wan-Tae;Park, Ki-Sik;Cho, Sung-Joon
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.5
    • /
    • pp.684-690
    • /
    • 2010
  • Recently, the NG(Next Generation) system is studied for supporting convergence of various services and multi mode of single terminal. And a demand of user for taking the various services is getting increased, for supporting these services, many systems being able to transmit a large message have been appeared. In the NG system, it has to be supporting the CDMA and WCDMA besides the tele communication systems using OFDM method with single terminal An intergrated system can be improved with adopting of SoC technique. For adopting SoC technique on the intergrated terminal, we have to solve the non linear problem of HPA(High Power Amplifier). Nonlinear characteristic of HPA distorts both amplitude and phase of transmit signal, this distortion cause deep adjacent channel interference. We adopt a polynomial pre-distortion technique for this problem. In this paper, a noble modem design for NG mobile communication service and a method using polynomial pre-distorter with PAPR technique for counterbalancing nonlinear characteristic of the HPA are proposed.

A Study on the Improvement of Measuring Methods in Land Suitability Assessment: Focused on the Distance Measurement and Threshold Definition (토지적성평가 평가방법 개선방안 연구 : 거리측정 및 임계치 설정방안을 중심으로)

  • Jeong, Yeun-Woo;Lee, Sang-Jun
    • Land and Housing Review
    • /
    • v.3 no.1
    • /
    • pp.69-78
    • /
    • 2012
  • This study proposes an approach to improve the accuracy of land assessment result focused on the Land Suitability Assessment. The detailed analysis processes are; (a) that they are analyzed considering resistance in distance measurement on the space characteristics of location, and; (b) that an assessment result is measured according to the threshold definition of membership function, which is applied in estimating conservation suitability. The assessment results are; firstly, the method considering resistance better reflects the local characteristics of area with worse accessibility including rivers and mountains than one by linear distance; secondly, the existing method that the maximum value of a target area is defined as the maximum threshold may draw a value evaluated lower than a threshold definition considering the distribution of measured indices. Finally, satellite images are overlapped with the assessed results, the applicability level from the approach proposed by this study is more coincident with the present status. The assessment method proposed by this study can be meaningful in view of that it improves the accuracy of Land Suitability Assessment. Furthermore, it can be applied as SDSS, which can support effective establishment of urban policies, in case of complementing the problems in executing the assessment system.