• Title/Summary/Keyword: local cooling temperature

Search Result 183, Processing Time 0.031 seconds

Film Boiling Heat Transfer Model of Spray Cooling Focusing on Rebound Motion of Droplets (액적의 리바운드 모션에 주목한 분무냉각 막 비등 열전달 모델)

  • Kim Yeung Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.2 s.233
    • /
    • pp.287-293
    • /
    • 2005
  • In the present study, to determine the flow rate of droplets supplied to heat transfer surface after (j-1)th rebound, $D_X[j{\ge}2]^{\ast}$, it was assumed that the rebound droplets are distributed according to the Gaussian distribution from 0 to L, in which the flight distance L is determined by maximum flight distance $L_{max}$. We also assumed that $L_{max}$ is dependent on the air flow velocity and mean size of droplets. The local heat flux of a dilute spray in high temperature region was predicted using the newly evaluated $D_X[j{\ge}2]^{\ast}$. In addition, the predicted results by the present model were compared with the existing experimental data.

Numerical Study of Natural Convection in a Rectangular Enclosure with Cooling Strip (냉각부(冷却部)를 갖는 사각형(四角形) 밀폐공간내(密閉空間內)의 자연대류(自然對流)에 관(關)한 수치해석(數値解析))

  • Lee, Cheong-Ouk;Seo, Jeong-Yun;Kim, Chong-Bo
    • Solar Energy
    • /
    • v.6 no.2
    • /
    • pp.54-61
    • /
    • 1986
  • The influence on natural convection was studied by solving the partial differential equations within a rectangular enclosure which have a cooling strip at the right side wall of the space, a isothermally heated bottom plate and adiabatic two other walls. Computation was carried out for the range of Grashof number from $5*10^3$ to $2.5*10^5$ with Plandtl number of 0.73. The results have been obtained in cases of four aspect ratios and various strip sizes. Temperature and Stream function distributions have been plotted using explicit finite difference method in two dimensional, laminar flow, and also mean Nusselt number and Local Nusselt number have been obtained.

  • PDF

Heat Conduction Analysis of Spreaders with Concentrated Heat Sources-Thermal Concentration Effect in Cooling Electronic Devices- (집중열원이 있는 방산판의 열전도 해석-전자부품 냉각에서의 열집중 현상-)

  • 최상민
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.4
    • /
    • pp.726-733
    • /
    • 1989
  • Conduction heat transfer in heat spreaders with concentrated heat sources is analyzed by finite element method calculation and the results are compared to analytical solutions for simplified cases. The local temperature rise is dependent on the heat flux, thermal conductivity of the spreader material, and the contact size of the heat source. The effect of the adjacency of other heat sources is also examined.

Evaluation of High Cycle Thermal Fatigue on Mixing Tee in Nuclear Power Plant (원전 Mixing Tee에서의 고주기 열피로 평가)

  • Lee, Sun Ki
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.16 no.1
    • /
    • pp.22-29
    • /
    • 2020
  • In nuclear power plants, there is a risk of thermal fatigue in equipment and piping affecting system soundness because the temperature change of the system accompanies in every operation and shutdown. Therefore, in order to prevent the excess of the fatigue limit during the lifetime of plants, the fatigue limit of each piping material is determined in the designing stage. However, there are many cases where equipment or piping is locally subjected to thermal fatigue that is not considered in the design, resulting in damage to the equipment and piping, and failure during operation. Currently, local thermal fatigue generation mechanisms that are not taken into account in the design stage are gradually being identified. In this paper, the effects of the fluid temperature fluctuations on the piping soundness due to the mixing of hot and cold water, one of the local thermal fatigue generating mechanisms, were evaluated.

Development of a Model for Analylzing and Evaluating the Suitability of Locations for Cooling Center Considering Local Characteristics (지역 특성을 고려한 무더위쉼터의 입지특성 분석 및 평가 모델 개발)

  • Jieun Ryu;Chanjong Bu;Kyungil Lee;Kyeong Doo Cho
    • Journal of Environmental Impact Assessment
    • /
    • v.33 no.4
    • /
    • pp.143-154
    • /
    • 2024
  • Heat waves caused by climate change are rapidly increasing health damage to vulnerable groups, and to prevent this, the national, regional, and local governments are establishing climate crisis adaptation policy. A representative climate crisis adaptation policy to reduce heat wave damage is to expand the number of cooling centers. Because it is highly effective in a short period of time, most metropolitan local governments, except Jeonbuk, include the project as an adaptation policy. However, the criteria for selecting a cooling centers are different depending on the budget and non-budget, so the utilization rate and effectiveness of the cooling centers are all different. Therefore, in this study, we developed logistic regression models that can predict and evaluate areas with a high probability of expanding cooling centers in order to implement adaptation policy in local governments. In Incheon Metropolitan City, which consists of various heat wave-vulnerable environments due to the coexistence of the old city and the new city, a logistic model was developed to predict areas where heat waves can be cooling centered by dividing it into Ganghwa·Ongjin-gun and other regions, taking into account socioeconomic and environmental differences. As a result of the study, the statistical model for the Ganghwa·Ogjin-gun region showed that the higher the ground surface temperature and the more and more the number of elderly people over 65 years old, the higher the possibility of location of cooling centers, and the prediction accuracy was about 80.93%. The developed logistic regression model can predict and evaluate areas with a high potential as cooling centers by considering regional environmental and social characteristics, and is expected to be used for priority selection and management when designating additional cooling centers in the future.

A Numerical Study on the Effects of Urban Forest and Street Tree on Air Flow and Temperature (도시숲과 가로수가 대기 흐름과 기온에 미치는 영향에 관한 수치 연구)

  • Kang, Geon;Choi, Wonsik;Kim, Jae-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1395-1406
    • /
    • 2022
  • This study investigated the effects of the urban forest and street trees on flow and temperature distribution in the Daegu National Debt Redemption Movement Memorial Park. For this, we implemented tree-drag and tree-cooling parameterization schemes in a computational fluid dynamics (CFD) model and validated the simulated wind speeds, wind directions, and air temperatures against the measured ones. We used the wind speeds, wind directions, air temperatures predicted by the local data assimilation and prediction system (LDAPS) as the inflow boundary conditions. To investigate the flow and thermal characteristics in the presence of trees in the target area, we conducted numerical experiments in the absence and presence of trees. In the absence of trees, strong winds and monotonous flows were formed inside the park, because there were no obstacles inducing friction. The temperature was inversely proportional to the wind speed. In the presence of trees, the wind speeds(temperatures) were reduced by more than 40 (5)% inside the park with a high planting density due to the tree drag (cooling) effect, and those also affected the wind speeds and temperatures outside the park. Even near the roadside, the wind speeds and temperatures were generally reduced by the trees, but the wind speeds and air temperatures increased partly due to the change in the flow pattern caused by tree drag.

Seasonal Cycle of Sea Surface Temperature in the East Sea and its Dependence on Wind and Sea Ice

  • Park, Kyung-Ae;Chung, Jong-Yul;Kim, Kuh
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.618-620
    • /
    • 2003
  • Harmonics of sea surface temperature (SST) in the East Sea and their possible causes are examined by analyzing NOAA/AVHRR data, SSM/I wind speeds, NSCAT wind vectors, and NCEP heat flux data. Detailed spatial structures of amplitudes and phases of the seasonal cycles and their contributions to the total variance of SST have quantitatively. The Subpolar front serves as a boundary between regions of high annual amplitudes (${\geq}$10$^{\circ}$C) in the cold continental region and low amplitudes (${\leq}$10$^{\circ}$C) in the Tsushima Warm Current region. The low phase center of annual cycle is located over a seamount at 132.2$^{\circ}$E, 41.7$^{\circ}$N south of Vladivostok. Semi-annual amplitudes are significantly large leaching over 20% of the annual amplitudes in the Tatarskiy Strait and along the continental shelf off Russian coast in fall and spring, but its forcings are substantially annual. We have shown that fall cooling is attributed by direct and local wind forcing, while spring cooling is remotely forced by cold waters from sea ices in the Tatarskiy Strait.

  • PDF

Stability and normal zone propagation in YBCO tapes with Cu stabilizer depending on cooling conditions at 77 K

  • Kruglov, S.L.;Polyakov, A.V.;Shutova, D.I.;Topeshkin, D.A.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.4
    • /
    • pp.14-19
    • /
    • 2020
  • Here we present the comparative experimental study of the stability of the superconducting state in 4 mm YBCO tapes with copper lamination against local heat disturbances at 77 K. The samples are either directly cooled by immersing a bare YBCO tape into a liquid nitrogen pool or operate in nearly-adiabatic conditions when the tape is covered by a 0.6 mm layer of Kapton insulation. Main quench characteristics, i.e. minimum quench energies (MQEs) and normal zone propagation (NZP) velocities for both samples are measured and compared. Minimum NZP currents are determined by a low ohmic resistor technique eligible for obtaining V - I curves with a negative differential resistance. The region of transport currents satisfying the stationary stability criterion is found for the different cooling conditions. Finally, we use the critical temperature margin as a universal scaling parameter to compare the MQEs obtained in this work for YBCO tapes at 77 K with those taken from literature for low-temperature superconductors in vacuum at 4.2 K, as well as for MgB2 wires cooled with a cryocooler down to 20 K.

The optimal array of various heat-generating heaters located on one wall of a vertical open top cavity (상부가 개방된 수직 캐비티내의 한쪽면에 배열된 다양한 발열조건을 갖는 발열체의 최적배열)

  • Riu, Kap-Jong;Choo, Hong-Lock;Choi, Byung-Cheol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.1
    • /
    • pp.15-23
    • /
    • 1997
  • An experimental investigation of two-dimensional steady natural convection cooling in a vertical open top cavity with conducting side walls of finite thickness is presented. The various heat-generating discrete heaters are located on one vertical wall of the cavity. When each heater dissipates different amount of power, the purpose of the work is to obtain the optimal array condition of the heaters. The four cases of non-uniform heating conditions are considered. The temperature fields in the cavity were visualized by the interferometer and local temperatures of the vertical wall were measured by thermocouples. The heaters were arranged in two configurations: flush-mounted on a vertical wall or protruding from the wall about 4.5 mm. The vertical wall was constructed out of copper or epoxy-resin sheet. Experiments have been conducted for air with constant Prandtl number(Pr=0.7), the aspect ratio of 4.6, 7.5, 9.5, power input in the range of 0.9 W ~ 4.2 W. For the enhancement of the cooling effectiveness, the upper and lower of vertical wall would give the better position for the heaters of higher heat flux.

The Simulations on the Formability of AZ31 Magnesium Alloy Sheet in Warm Deep Drawing (AZ31 마그네슘합금판의 온간 디프드로잉 성형성해석)

  • Kang, Dae-Min;Hwang, Jong-Kwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.3 no.1
    • /
    • pp.52-58
    • /
    • 2004
  • The material used is a commercial magnesium based alloy AZ31(Mg-3Al-1Zn)sheet with a thickness of 1.0mm. Uniaxial tension tests at warm temperature were carried out to investigate the material characteristics of K, m, and n. A warm drawing process with a local heating and cooling technique was developed to improve formability in this study with results of uniaxial tension tests because it is very difficult for Mg alloy to deform at room temperature by the conventional method. The die and blank holder were heated up, while the punch was water-cooled during deformation. FE simulations considering heat transfer were executed with Mg alloy to investigate the Improvement of deep drawability. For the assessment of improvement those were compare with the results of no considering heat transfer and room temperature.

  • PDF