• 제목/요약/키워드: local cooling

검색결과 342건 처리시간 0.024초

엇갈린 배열의 사각홀이 막냉각에 미치는 영향 (The Effects of Staggered Rows of Rectangular Shaped Holes on Film Cooling)

  • 김영봉;이동호;이윤석;조형희
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.304-314
    • /
    • 2004
  • An experimental study has been conducted to measure the temperature fields and the local film cooling effectiveness for two and three staggered rows of the rectangular shaped-holes with various blowing rates. The hydraulic diameter of rectangular-shaped hole is 10mm. To compare with the film cooling performance of rectangular-shaped hole, two kinds of circular holes are tested. One has the same hydraulic diameter as the rectangular hole and the other has the same cross sectional area. Also, rectangular holes with expanded exit with same inlet area as rectangular ones are tested. Temperature fields are measured using a thermocouple rake attached on three-axis traversing system. Adiabatic film cooling effectiveness on the surface are obtained based on experimental results of thermochromic liquid crystals. The film cooling effectiveness is measured for various blowing rates and compared with the results for the cylindrical holes. In case of 2 rows, the rectangular holes has better performance than circular holes due to its slot-like geometry. In case of 3 rows, the effecta of hole shape is not clear.

Optimized Local Relocation for VLSI Circuit Modification Using Mean-Field Annealing

  • Karimi, Gholam Reza;Verki, Ahmad Azizi;Mirzakuchaki, Sattar
    • ETRI Journal
    • /
    • 제32권6호
    • /
    • pp.932-939
    • /
    • 2010
  • In this paper, a fast migration method is proposed. Our method executes local relocation on a model placement where an additional module is added to it for modification with a minimum number of displacements. This method is based on mean-field annealing (MFA), which produces a solution as reliable as a previously used method called simulated annealing. The proposed method requires substantially less time and hardware, and it is less sensitive to the initial and final temperatures. In addition, the solution runtime is mostly independent of the size and complexity of the input model placement. Our proposed MFA algorithm is optimized by enabling module rotation inside an energy function called permissible distances preservation energy. This, in turn, allows more options in moving the engaged modules. Finally, a three-phase cooling process governs the convergence of problem variables called neurons or spins.

Effect of Chip Spacing in a Multichip Module on the Heat Transfer for Paraffin Slurry Flow

  • Choi, Min-Goo;Cho, Keum-Nam
    • Journal of Mechanical Science and Technology
    • /
    • 제14권9호
    • /
    • pp.997-1004
    • /
    • 2000
  • The experiments were conducted by using water and paraffin slurry to investigate the effect of a chip spacing in the multichip module on the cooling characteristics from an in-line $4{\times}3$ array of discrete heat sources which were flush mounted on the top wall of a channel. The experimental parameters were chip spacing in a multichip module, heat flux of simulated VLSI chip, mass fraction of paraffin slurry, and channel Reynolds number. The removable heat flux at the same chip surface temperature decreased as the chip spacing decreased at the first and fourth rows. The local heat transfer coefficients for the paraffin slurry were larger than those for water, and the chip spacing on the local heat transfer coefficients for paraffin slurry influenced less than that for water. The enhancement factor for paraffin slurry showed the largest value at a mass fraction of 5% regardless of the chip spacing, and the enhancement factors increased as the chip spacing decreased. This means that the paraffin slurry is more effective than water for cooling of the highly integrated multichip module.

  • PDF

Measurements of Ventilation Effectiveness in an Underfloor Air-Conditioned Space Using a Tracer Gas Technique

  • Han, Hwa-Taik;Seo, S.Y.;Kim, M.H.;Kim, Young-Il
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제7권
    • /
    • pp.91-100
    • /
    • 1999
  • This paper investigates ventilation characteristics of an environmental chamber simulating an under-floor air conditioning system for isothermal and cooling supply air conditions. The tracer gas sulfur-hexafluoride (SF$F_6$) was injected into a supply duct using step-up and step-down methods. Local mean and room mean ages were calculated from the concentrations measured at internal points and at the exhaust duct. The air change efficiency of the chamber has been found to be greater in cooling conditions than in isothermal conditions. Also the room air change efficiency is not significantly affected but slightly improved by the presence of a supply diffuser.

  • PDF

분지내의 야간 접지역전층 변화와 관련된 기상요소에 대한 연구 (Relations Between the Nocturnal Inversion Layer and Some Meteorological Elements in the Basin)

  • 진병화;황수진
    • 한국환경과학회지
    • /
    • 제7권3호
    • /
    • pp.369-374
    • /
    • 1998
  • Meteorological measurements were carried out in the basin of Cheong-Kwan located Yang-San near Pusan city, from Oct. 30 to Nov. 1, 1988. According to the measured data, we vended the close relationship between the variation of nocturnal Inversion layer and the meteorological elements. The nocturnal intrersion layer by radiative cooling in this site extends up to 130 meters or so. And the nocturnal jet ap- pears just above or at the top of the inversion layer, and the stronger of the prevailing wind blows, and the lower of the jet level appears. Some meteorological features such as heating, cooling etc., began to change in or in the slightly higher level of the inversion layer, when they are formed, reinforced and disappeared. And the it In the basin preserves its character because It Is not affected by local scale air flow.

  • PDF

Thermal Analysis on Triple-Passage Heat Exchangers for a Continuous Hot-Steel Tube Cooling System

  • Ko, Bong-Hwan;Park, Seung-Ho
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권1호
    • /
    • pp.10-18
    • /
    • 2002
  • The objective of present study is to analyze a concentric triple-passage heat exchanger for an optimal design of a continuous hot steel-tube cooling system, where a hot-steel tube line is passing through an antioxidant gas with a constant speed. Velocities and temperatures of the inert gas flowing between inner and outer tubes are calculated theoretically for laminar and numerically for turbulent flow regimes. From their profiles Nusselt numbers and friction factors are calculated (or various ratios of inner/outer tube radii and relative velocities. With these Nusselt numbers triple-passage heat exchangers are investigated for their thermal characteristics. It is shown that heat transfer coefficients based on ratios of average heat fluxes from inner and outer tubes might result in great errors for the temperature distributions of the flows, since local heat transfer coefficients for flows through an annulus are dependent on local wall heat flux ratios.

추적가스를 이용한 바닥취출 공조공간내의 환기효율 측정실험 (Ventilation effectiveness measurements utilizing a tracer gas in an under floor air-conditioning space)

  • 한화택;서세영;김명호;김영일
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.610-618
    • /
    • 1998
  • In this study, a tracer gas technique was used to measure ventilation effectiveness in a thermal environmental chamber simulating an under-floor air conditioning system. A tracer gas of $SF_6$ was injected in a supply duct using step-up and step-down methods. Local mean ages and room mean ages were calculated from the measured concentrations under isothermal and cooling conditions with and without diffusers. Ventilation effectiveness is found to be higher in cooling ventilation operations than in isothermal operations. Results also show that ventilation effectiveness is not significantly affected by a diffuser.

  • PDF

고온의 강관 냉각용 삼중 열교환기에 대한 열해석 (Thermal analysis on triple-passage heat exchangers for a hot tube cooling system)

  • 고봉환;박승호;신동신
    • 설비공학논문집
    • /
    • 제11권5호
    • /
    • pp.615-623
    • /
    • 1999
  • The objective of present study is to analyze a hot steel-tube cooling system as a kind of concentric triple-passage heat exchanger, whose inner tube is moving with a constant speed. Velocities and temperatures of an antioxidant gas flowing between inner and outer tubes are calculated theoretically for both laminar and turbulent flow regimes and used to give Nusselt numbers and friction factors with respect to various radius ratios and velocity ratios. In addition, it is shown that heat transfer coefficients based on ratios of average heat fluxes from inner and outer tubes might result in great errors for the temperature distributions of the flows, since the local heat transfer coefficients are dependent on the local heat flux ratios.

  • PDF

Formation of globular clusters in cosmological radiation hydrodynamic simulation

  • Yi, Sukyoung K.;Kimm, Taysun
    • 천문학회보
    • /
    • 제41권2호
    • /
    • pp.36.1-36.1
    • /
    • 2016
  • This is a presentation of the paper published as Kimm et al. 2016, ApJ, 823, 52. We investigate the formation of metal-poor globular clusters (GCs) at the center of two dark matter halos with $Mhalo{\sim}4{\times}107Msun$ at z>10 using cosmological radiation-hydrodynamics simulations. We find that very compact (${\leq}1$ pc) and massive (${\sim}6{\times}105Msun$) clusters form rapidly when pristine gas collapses isothermally with the aid of efficient $Ly{\alpha}$ emission during the transition from molecular-cooling halos to atomic-cooling halos. Because the local free-fall time of dense star-forming gas is very short (${\ll}1Myr$), a large fraction of the collapsed gas is turned into stars before stellar feedback processes blow out the gas and shut down star formation. Although the early stage of star formation is limited to a small region of the central star-forming disk, we find that the disk quickly fragments due to metal enrichment from supernovae. Sub-clusters formed in the fragmented clouds eventually merge with the main cluster at the center. The simulated clusters closely resemble the local GCs in mass and size but show a metallicity spread that is much wider than found in the local GCs. We discuss a role of pre-enrichment by Pop III and II stars as a potential solution to the latter issue. Although not without shortcomings, it is encouraging that a naive blind (not tuned) cosmological simulation presents a possible channel for the formation of at least some massive GCs.

  • PDF

냉각수온 효과에 따른 고온 강판의 스프레이 냉각 열전달 특성 연구 (Effect of Water Temperature on Heat Transfer Characteristic of Spray Cooling on Hot Steel Plate)

  • 이정호;유청환;박상진
    • 대한기계학회논문집B
    • /
    • 제35권5호
    • /
    • pp.503-511
    • /
    • 2011
  • 수분류 스프레이 냉각은 $900^{\circ}C$ 이상의 고온에서 강판을 냉각하는데 매우 중요한 기술이다. 본 연구는 냉각수온이 고온 강판의 수분류 스프레이 냉각에 미치는 영향을 고찰하였다. 이 때의 열유속은 시편, 카트리지히터, 열전대의 조합으로 고안된 열유속게이지를 제작하여 엄밀하게 측정되었다. 스프레이는 fullcone 노즐로부터 생성되고 냉각실험은 일정한 스프레이 질량유속과 노즐과 표면 사이의 거리 조건에서 수행되었다. 냉각수온의 효과는 $5^{\circ}C$에서 $45^{\circ}C$까지 다섯 가지의 서로 다른 수온에 대한 수분류 스프레이 냉각의 열전달 현상을 비교 및 평가하였다. 여기서 열유속곡선과 열전달계수는 고온 강판의 냉각공정에서 실제 스프레이 냉각을 위한 기본 데이터로 활용될 수 있다.