• 제목/요약/키워드: local compression

검색결과 405건 처리시간 0.022초

탄소섬유쉬트로 구속된 콘크리트충전 각형강관기둥의 단조압축실험 (The Experimental Study on Axial Loaded Concrete Filled Steel Tube Confined by Carbon Fiber Sheet)

  • 박재우;홍영균;홍기섭;이성희;최성모
    • 한국강구조학회 논문집
    • /
    • 제21권3호
    • /
    • pp.311-320
    • /
    • 2009
  • 본 연구에서는 기존 각형 CFT기둥 실험체와 탄소섬유쉬트로 추가구속된 각형 CFT기둥 실험체의 단조압축거동 및 압축내력평가에 관한 실험을 수행하였다. 실험변수는 탄소섬유쉬트 보강겹수와 폭-두께비이며, 실험변수에 따라 총 9개의 실험체를 제작하여 단조압축실험을 수행하였다. 실험을 통하여 기존 CFT 실험체와 탄소섬유쉬트로 구속된 CFT 실험체의 파괴거동, 하중-축변위 곡선, 최대내력, 변형성능을 비교한다. 끝으로 탄소섬유쉬트의 추가구속은 기둥의 국부좌굴을 지연시켰으며 이로 인해 실험체의 최대내력이 상승한 것으로 나타났다.

Physical and Mechanical Properties of Local Styrax Woods from North Tapanuli in Indonesia

  • Iswanto, Apri Heri;Susilowati, Arida;Azhar, Irawati;Riswan, Riswan;Supriyanto, Supriyanto;Tarigan, Joel Elpinta;Fatriasari, Widya
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권4호
    • /
    • pp.539-550
    • /
    • 2016
  • The objective of this research was to evaluate physical and mechanical properties of three species of Styrax woods from North Tapanuli in Indonesia. The woods were more than 15 years old. Physical properties such as specific gravity, green moisture content, and volume shrinkage were determined by the procedures based on BS-373 standard for small clear specimen. Furthermore, mechanical properties, including modulus of rupture, modulus of elasticity, compression parallel to grain and hardness were also tested according to the standard. Along the stem direction, the edge section had better properties compared with those near the pith section. And the base section had also better properties than upper section. Based on the specific gravity, all of the Styrax woods in this research were classified into III-IV strength classes. A good dimensional stability was demonstrated by the value of the tangential and radial ratio which reached one. With the consideration of the mechanical properties, Styrax woods were suitable use for raw materials of light construction, furniture and handy craft.

Ultrasound-guided Lateral Femoral Cutaneous Nerve Block in Meralgia Paresthetica

  • Kim, Jeong-Eun;Lee, Sang-Gon;Kim, Eun-Ju;Min, Byung-Woo;Ban, Jong-Suk;Lee, Ji-Hyang
    • The Korean Journal of Pain
    • /
    • 제24권2호
    • /
    • pp.115-118
    • /
    • 2011
  • Meralgia paresthetica is a rarely encountered sensory mononeuropathy characterized by paresthesia, pain or sensory impairment along the distribution of the lateral femoral cutaneous nerve (LFCN) caused by entrapment or compression of the nerve as it crossed the anterior superior iliac spine and runs beneath the inguinal ligament. There is great variability regarding the area where the nerve pierces the inguinal ligament, which makes it difficult to perform blind anesthetic blocks. Ultrasound has developed into a powerful tool for the visualization of peripheral nerves including very small nerves such as accessory and sural nerves. The LFCN can be located successfully, and local anesthetic solution distribution around the nerve can be observed with ultrasound guidance. Our successfully performed ultrasound-guided blockade of the LFCN in meralgia paresthetica suggests that this technique is a safe way to increase the success rate.

지반조건에 따른 마이크로파일 설치방법에 관한 연구 (Installation of Micro-piles Appropriate to Soil Conditions)

  • 황태현;문경련;신용석;권오엽
    • 한국지반공학회논문집
    • /
    • 제28권4호
    • /
    • pp.55-65
    • /
    • 2012
  • 본 연구는 지반조건에 따른 효과적인 마이크로 파일의 설치방법을 제안하기 위해 실트 또는 모래지반에서 모형시험을 수행하였다. 시험결과, 관입 전단파괴가 발생한 실트지반은 압축변위에 저항하도록 마이크로 파일을 엇갈리게 설치(${\theta}$ < $0^{\circ}$)하는 것이 효과적이며, 전면 또는 국부전단파괴가 발생한 모래인 경우 횡 방향 변위에 저항하도록 마이크로 파일을 경사지게 설치(${\theta}$ > $0^{\circ}$ 또는 ${\theta}$ < $0^{\circ}$) 하는 것이 효과적인 것으로 나타났다.

Gravitational Instability of Rotating, Vertically-Stratified, Polytropic Disks

  • 김정규;김웅태;홍승수
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.111.2-111.2
    • /
    • 2011
  • While many astrophysical disks are vertically stratified and obey a polytropic equation of state, most studies on gravitational instability (GI) of flattened systems consider isothermal, razor-thin disks by taking vertical averages of disk properties. We investigate local GI of rotating pressure-confined polytropic disks with resolved vertical stratification by performing linear stability analysis. We find that the GI of vertically-stratified disks is in general a combination of conventional razor-thin Jeans modes and incompressible modes. The incompressible modes that dominate in the limit of the maximal disk compression require surface distortion and are an unstable version of terrestrial water waves. Disks with a steeper equation of state are found to be more Jeans unstable because they tend to have a smaller vertical scale height as well as a steeper temperature gradient corresponding to lower pressure support. GI depends more sensitively on the vertical temperature than density distribution. The density-weighted, harmonic mean, rather than the simple mean, of the adiabatic sound speed well describes the dispersion relation of horizontal modes, and thus is appropriate in the expression for Toomre Q stability parameter of razor-thin disks. We generalize Q into vertically-stratified disks, and discuss astrophysical application of our work.

  • PDF

Numerical Analysis of an Air-cooled Ammonia Condenser with Plate Fins

  • Kim, Young-Il;Kang, Byung-Ha
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.104-112
    • /
    • 1998
  • Ammonia has been used as refrigerant for more than 100 years in absorption as well as in compression systems. Due to its poisonous and inflammable properties, however, its use has been mainly on heavy industrial plants in which regular maintenance is available. For these systems, condensers are generally water∼cooled. This is suitable for large systems over 20RT but is not suitable for small systems. In order to apply ammonia for a small system, it is important to adopt an air-cooled condenser. In this study, simple numerical analysis of an air-cooled condenser for an ammonia refrigeration system has been carried out. The condenser is designed as horizontal tubes with plate fins attached at the outer surface to enhance the air-side heat transfer rate. Effect of fin shape and arrangement are studied in detail. Since the local heat transfer coefficient is highest at the leading edge, heat flux is highest at the edge and decreases along the distance. Conditions of inlet air are also varied in the study and condenser length that is required for full condensation is calculated. The results show that it is important to enhance both the air-side and internal heat transfer coefficients.

  • PDF

시각특성을 고려한 디지털 흉부 X-선 영상의 적응적 향상기법 (Adaptive image enhancement technique considering visual perception property in digital chest radiography)

  • 김종효;이충웅;민병구;한만청
    • 전자공학회논문지B
    • /
    • 제31B권8호
    • /
    • pp.160-171
    • /
    • 1994
  • The wide dynamic range and severely attenuated contrast in mediastinal area appearing in typical chest radiographs have often caused difficulties in effective visualization and diagnosis of lung diseases. This paper proposes a new adaptive image enhancement technique which potentially solves this problem and there by improves observer performance through image processing. In the proposed method image processing is applied to the chest radiograph with different processing parameters for the lung field and mediastinum adaptively since there are much differences in anatomical and imaging properties between these two regions. To achieve this the chest radiograph is divided into the lung and mediastinum by gray level thresholding using the cumulative histogram and the dynamic range compression and local contrast enhancement are carried out selectively in the mediastinal region. Thereafter a gray scale transformation is performed considering the JND(just noticeable difference) characteristic for effective image displa. The processed images showed apparenty improved contrast in mediastinum and maintained moderate brightness in the lung field. No artifact could be observed. In the visibility evaluation experiment with 5 radiologists the processed images with better visibility was observed for the 5 important anatomical structures in the thorax.

  • PDF

Robust Image Hashing for Tamper Detection Using Non-Negative Matrix Factorization

  • Tang, Zhenjun;Wang, Shuozhong;Zhang, Xinpeng;Wei, Weimin;Su, Shengjun
    • Journal of Ubiquitous Convergence Technology
    • /
    • 제2권1호
    • /
    • pp.18-26
    • /
    • 2008
  • The invariance relation existing in the non-negative matrix factorization (NMF) is used for constructing robust image hashes in this work. The image is first re-scaled to a fixed size. Low-pass filtering is performed on the luminance component of the re-sized image to produce a normalized matrix. Entries in the normalized matrix are pseudo-randomly re-arranged under the control of a secret key to generate a secondary image. Non-negative matrix factorization is then performed on the secondary image. As the relation between most pairs of adjacent entries in the NMF's coefficient matrix is basically invariant to ordinary image processing, a coarse quantization scheme is devised to compress the extracted features contained in the coefficient matrix. The obtained binary elements are used to form the image hash after being scrambled based on another key. Similarity between hashes is measured by the Hamming distance. Experimental results show that the proposed scheme is robust against perceptually acceptable modifications to the image such as Gaussian filtering, moderate noise contamination, JPEG compression, re-scaling, and watermark embedding. Hashes of different images have very low collision probability. Tampering to local image areas can be detected by comparing the Hamming distance with a predetermined threshold, indicating the usefulness of the technique in digital forensics.

  • PDF

A dual-path high linear amplifier for carrier aggregation

  • Kang, Dong-Woo;Choi, Jang-Hong
    • ETRI Journal
    • /
    • 제42권5호
    • /
    • pp.773-780
    • /
    • 2020
  • A 40 nm complementary metal oxide semiconductor carrier-aggregated drive amplifier with high linearity is presented for sub-GHz Internet of Things applications. The proposed drive amplifier consists of two high linear amplifiers, which are composed of five differential cascode cells. Carrier aggregation can be achieved by switching on both the driver amplifiers simultaneously and combining the two independent signals in the current mode. The common gate bias of the cascode cells is selected to maximize the output 1 dB compression point (P1dB) to support high-linear wideband applications, and is used for the local supply voltage of digital circuitry for gain control. The proposed circuit achieved an output P1dB of 10.7 dBm with over 22.8 dBm of output 3rd-order intercept point up to 0.9 GHz and demonstrated a 55 dBc adjacent channel leakage ratio (ACLR) for the 802.11af with -5 dBm channel power. To the best of our knowledge, this is the first demonstration of the wideband carrier-aggregated drive amplifier that achieves the highest ACLR performance.

Non-destructive evaluation of concrete quality using PZT transducers

  • Tawie, R.;Lee, H.K.;Park, S.H.
    • Smart Structures and Systems
    • /
    • 제6권7호
    • /
    • pp.851-866
    • /
    • 2010
  • This paper presents a new concept of using PZT (lead zircornate titanate) transducers as a non-destructive testing (NDT) tool for evaluating quality of concrete. Detection of defects in concrete is very important in order to check the integrity of concrete structures. The electro-mechanical impedance (EMI) response of PZT transducers bonded onto a concrete specimen can be used for evaluating local condition of the specimen. Measurements are carried out by electrically exciting the bonded PZT transducers at high frequency range and taking response measurements of the transducers. In this study, the compression test results showed that concrete specimens without sufficient compaction are likely to fall below the desired strength. In addition, the strength of concrete was greatly reduced as the voids in concrete were increased. It was found that the root mean square deviation (RMSD) values yielded between the EMI signatures for concrete specimens in dry and saturated states showed good agreement with the specimens' compressive strength and permeable voids. A quality metric was introduced for predicting the quality of concrete based on the dry-saturated state of concrete specimens. The simplicity of the method and the current development towards low cost and portable impedance measuring system, offer an advantage over other NDE methods for evaluating concrete quality.