• Title/Summary/Keyword: local compression

Search Result 405, Processing Time 0.029 seconds

Evaluation on Applicability of Built-up Square Tubular Compression Members Fabricated with HSA800 High Performance Steel Considering Local Buckling (국부좌굴을 고려한 건축구조용 고성능강(HSA800) 조립각형강관 압축재의 적용성 평가)

  • Yoo, Jung Han;Kim, Joo Woo;Yang, Jae Guen;Kang, Joo Won;Lee, Dong Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.3
    • /
    • pp.223-231
    • /
    • 2013
  • Recently, high-performance steels have been increasingly used for structural materials in buildings and bridges with the demand for high-rise and long-span of main structures. This paper offers a series of basic study for the design specification of structural members using high performance steel, that is material properties of HSA800 (High-performance rolled steel for building structures). Built-up square tube stub columns with variables of width-to-thickness ratios are planned as a parametric study in order to investigate the local buckling behaviors and check the current design limit of width-to-thickness ratio. In addition, the buckling behaviors of stub columns obtained finite element (FE) analysis were compared with those from experimental tests. The verified FE model was used for parametric study and checked applicability of high-strength steel on current design specification.

An Analytical Study of Flange Local Buckling of Horizontally Curved I-Girders for Estimate Resonable Stress Gradient (합리적 응력경도 산정을 위한 수평 곡선 I-형 거더의 플랜지 국부좌굴의 해석적 연구)

  • Kim, Hee-Soo;Lee, Kee-Sei;Lee, Jeong-Hwa;Choi, Jun-Ho;Kang, Young-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6504-6510
    • /
    • 2015
  • Horizontally curved I-girders are subjected to not only bending moments but also torsional moments. The torsional moment of the plate girder is addition of St. Venant torsion and non-uniform torsion. In the flange of I-shaped plate girder, a kind of open-section, the normal stresses is not distributed uniformly due to the non-uniform torsion. Because of that, one of compression flange tip can be yielded faster than the flange of general straight girder. In other words, the flange local buckling strength is decreased when the girder has initial curvature. In this paper, the numerical analysis is conducted to investigate the average stresses in flange for curved girders. The subtended angle and slenderness ratio are taken as parameters.

A Study on the Dielectric Properties of Phospholipid Organic Thin Films (인지질 유기박막의 유전특성에 관한 연구)

  • Song, Jin-Won;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1983-1985
    • /
    • 1999
  • The dielectric constant of a monolayer on a material surface was calculated with consideration of the local field acting on polar molecules with a permanent dipole moment, and the interaction working between the molecules and a material. It is revealed that the dielectric relaxation time r of monolayers in the isotropic polar orientational phase is determined using a linear relationship between the monolayers compression speed a and the molecular area. The dielectric relaxation time of phospholipid monolayers was examined on the basis of analysis developed here.

  • PDF

Elastic Buckling Analysis of Orthotropic Plate with Edge Stiffener (연단보강재가 설치된 직교이방성 평판의 좌굴해석)

  • Yoon, Soon Jong;Lee, Won Bok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.2
    • /
    • pp.281-290
    • /
    • 1994
  • This paper presents the results of an analytical investigation pertaining to the compression behavior of axially loaded plates made from pultruded fiber reinforced plastic materials. Non-dimensionalized closed-form solutions have been developed for the prediction of the buckling load in the pultruded plates with edge stiffener. These solutions were based upon the classical theory of orthotropic plates and accounted for the e1astic restraints at the juncture of plate and stiffener. The effects of edge stiffener on the flange plate were investigated in order to clarify its usefulness for increasing flange local buckling load of the pultruded structural shapes.

  • PDF

EEG Signal Compression by Multi-scale Wavelets and Coherence analysis and denoising by Continuous Wavelets Transform (다중 웨이브렛을 이용한 심전도(EEG) 신호 압축 및 연속 웨이브렛 변환을 이용한 Coherence분석 및 잡음 제거)

  • 이승훈;윤동한
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.3
    • /
    • pp.221-229
    • /
    • 2004
  • The Continuous Wavelets Transform project signal f(t) to "Time-scale"plan utilizing the time varied function which called "wavelets". This Transformation permit to analyze scale time dependence of signal f(t) thus the local or global scale properties can be extracted. Moreover, the signal f(t) can be reconstructed stably by utilizing the Inverse Continuous Wavelets Transform. In this paper, the EEG signal is analyzed by wavelets coherence method and the De-noising procedure is represented.

Ferroelastic Domain Wall Motions in Lead Zirconate Titanate Under Compressive Stress Observed by Piezoresponse Force Microscopy

  • Kim, Kwanlae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.9
    • /
    • pp.546-550
    • /
    • 2017
  • Ferroelectric properties are governed by domain structures and domain wall motions, so it is of significance to understand domain evolution processes under mechanical stress. In the present study, in situ piezoresponse force microscopy (PFM) observation under compressive stress was carried out for a near-morphotropic PZT. Both $180^{\circ}$ and $non-180^{\circ}$ domain structures were observed from PFM images, and their habit planes were identified using electron backscatter diffraction in conjunction with PFM data. By externally applied mechanical stress, needle-like $non-180^{\circ}$ domain patterns were broadened via domain wall motions. This was interpreted via phenomenological approach such that the total energy minimization can be achieved by domain wall motion rather than domain nucleation mainly due to the local gradient energy. Meanwhile, no motion was observed from curvy $180^{\circ}$ domain walls under the mechanical stress, validating that $180^{\circ}$ domain walls are not directly influenced by mechanical stress.

A Study on the Full Scale Structural Test of High Voltage Electric Transmission Tower (초고압 송전철탑 구조성능시험에 관한 연구)

  • 김우범
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1994.04a
    • /
    • pp.171-180
    • /
    • 1994
  • Full scale structural test of 765kv electric transmission tower was performed to measure the stresses and displacement of towers under the design loadings, and the results were compared with analytical results based on three dimensional frame analysis. Also, the actual ultimate strength of the tower was measured through destructive test. Especially, to predict the behavior and failure of the connection of tubular member, finite element analysis was performed and compression test for the segments of tubular member were carried out. Valuable information for the overall and local behavior of the tower was obtained and reliability of current analytical method was confirmed.

  • PDF

Object-oriented coder using block-based motion vectors and residual image compensation (블러기반 움직임 벡터와 오차 영상 보상을 이용한 물체지향 부호화기)

  • 조대성;박래홍
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.3
    • /
    • pp.96-108
    • /
    • 1996
  • In this paper, we propose an object-oriented coding method in low bit-rate channels using block-based motion vectors and residual image compensation. First, we use a 2-stage algorithm for estimating motion parameters. In the first stage, coarse motion parameters are estimated by fitting block-based motion vectors and in the second stage, the estimated motion parametes are refined by the gradient method using an image reconstructed by motion vectors detected in the first stage. Local error of a 6-parameter model is compensted by blockwise motion parameter correction using residual image. Finally, model failure (MF) region is reconstructed by a fractal mapping method. Computer simulation resutls show that the proposed method gives better performance than the conventional ones in terms of th epeak signal to noise ratio (PSNR) and compression ratio (CR).

  • PDF

A Study on the Fracture Behavior of Quartz Glass(I) (석영 유리의 파괴 거동에 관한 연구(I))

  • Choi, Seong-Dae;Cheong, Seon-Hwan;Jeong, Young-Kwan;Kim, Gi-Man;Hong, Yong-Bae
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.10 no.3
    • /
    • pp.179-185
    • /
    • 2007
  • Quartz glass are used in semiconductor industries as the reaction furnace, wafer carrier and accessaries. During the process the quartz glass received compression by direct contact with other quartz glass ware and metal as the form of weight itself and vacuum pressure and fatigue by vibrations caused by process. Even as the other ceramic materials quartz glass have high compressive strength but often there happened crack and breakage of quartz glass resulted in a great damage in the process. In this paper investigation will be carried out on fracture behavior of quartz glass under local load to give guideline to prevent unintended fracture of quartz glass.

  • PDF

Uniaxial Compression Behavior of High-Strength Concrete Confined by Low-Volumetric Ratio Lateral Ties

  • Hong Ki-Nam;Han Sang-Hoon
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.5 s.89
    • /
    • pp.843-852
    • /
    • 2005
  • Presently, test results and stress-strain models for poorly confined high-strength columns, more specifically for columns with a tie volumetric ratio smaller than $2.0\%$, are scarce. This paper presents test results loaded in axial direction for square reinforced concrete columns confined by various volumetric ratio lateral ties including low-volumetric ratio. Test variables include concrete compressive strength, tie yield strength, tie arrangement type, and tie volumetric ratio. Local strains measured using strain gages bonded to an acryl rod. For square RC columns confined by lateral ties, the confinement effect was efficiently improved by changing tie arrangement type from Type-A to Type-B. A method to compute the stress in lateral ties at the concrete peak strength and a new stress-strain model for the confined concrete are proposed. Over a wide range of confinement parameters, the model shows good agreement with stress-strain relationships established experimentally.